236 resultados para RADIOIMMUNOASSAY
Resumo:
The mouse spleen cell assay (MSCA) has been compared with a radioimmunoassay for the measurement of serum erythropoietin (Ep). In 20 normal subjects the serum values ranged from 15 to 73 mU/ml for the MSCA compared with 5-30 mU/ml for the RIA. For normal sera there was no correlation between the results of the two assays. In 37 patients with anaemias of differing aetiologies and at various stages of treatment values ranged from 10 to 3645 mU/ml for the MSCA and 13-10,000 mU/ml for the RIA. Although patient values from the two assays were highly correlated (r = 0.98, P less than 0.001), the MSCA results were generally lower. These discrepancies can be largely accounted for by two factors. Firstly the MSCA is sensitive to non-specific matrix effects. Secondly, heat inactivation of serum, a prerequisite for the MSCA, but not for the RIA, destroys a variable and unpredictable proportion of the Ep in the test sera leading to an underestimation of Ep in the MSCA. We conclude that the RIA is more reliable than the MSCA which, in its present form, cannot be recommended for the accurate measurement of serum erythropoietin.
Resumo:
Neuropeptide Y (NPY) is a 36 amino acid peptide that is abundantly expressed in both the central and peripheral nervous systems. NPY has previously been shown to be present in human dental pulp although its exact role in pulpal health and disease remains to be fully elucidated. In addition to serving a neurotransmitter role, NPY may also have a role in modulating the pulpal response to injury and inflammation. Indeed NPY is known to be a potent vasoconstrictor in a range of tissues. Recent work by our research group has demonstrated changes in sensory neuropeptide levels measured by radioimmunoassay (RIA) in healthy and carious teeth. In addition to elevated levels of sensory neuropeptides, it is also possible that the carious process is associated with increased levels of autonomic neuropeptides such as NPY. Objectives: The aim of the present study was to undertake a comprehensive quantitative RIA analysis of NPY expression in human dental pulps from carious and non-carious teeth. Methods: A total of 22 non-carious and 46 carious teeth were included in the study. NPY was measured in all samples using RIA. Briefly, the RIA system consisted of a total volume of 400 ul, comprising 100 ul anti-NPY antibody (Peninsula Laboratories), 200 ul human NPY synthetic standard or pulp sample, and 100 ul of 125I-labelled NPY as radioactive tracer. Results: The mean concentration of NPY in non-carious teeth was found to be 4.28 ng/g (4.34 SD) compared to 9.57 ng/g (9.39 SD) in carious teeth. Using ANOVA the difference in NPY levels between the non-carious group and the carious group was found to be statistically significant (p= 0.003). Conclusion: The significant increase in the levels of NPY in carious dental pulps reported in this study provides evidence for a role for NPY in the pulpal response to caries.
Resumo:
The Adriatic sturgeon, Acipenser naccarii (Bonaparte, 1836), is a highly threatened species due to human activities, particularly overfishing and habitat destruction. Its peculiar ecology and biology (restricted areal and anadromy) makes this species particularly vulnerable. In March 2010 the IUCN has identified the Adriatic sturgeon as a critically endangered species according to the Red List of Threatened Species. Due to its rapid decline, starting from the 80s, at present there is no evidence of natural reproduction in wild environment, which makes the Adriatic sturgeon dependenton captive breeding programs that need to be improved in order to be effective for the survival of the species. For this purpose this study aims to characterize artificial restocking population of Adriatic sturgeon, with both genetic and physiological analysis in order to establish an efficient restocking program for future reproductions. The research is structured on two levels: First genetically, by analyzing 9 microsatellite loci. This gives information relatively about parent allocation and kinship between individuals that were sampled for this study. Hence to predict which reproduction events are the most optimal in terms of incrementing genetic diversity, by the estimation of multilocus pairwise band sharing coefficients. Second step, physiological analysis: testosterone (T) concentration levels in each individual were measured for sexing, without sacrificing the lives of the animals with the use of an invasive examination of the gonads. The combination of interdisciplinary analysis is important to obtain an overall picture in order to indicate the main broodstock participating in reproduction events and future optimal potential participants, in order to ensure a valid management for restocking program and their monitoring.
Resumo:
The hypothalamic-pituitary system controls homeostasis during feed energy reduction. In order to examine which pituitary proteins and hormone variants are potentially associated with metabolic adaptation, pituitary glands from ad libitum and energy restrictively fed dairy cows were characterized using RIA and 2-DE followed by MALDI-TOF-MS. We found 64 different spots of regulatory hormones: growth hormone (44), preprolactin (16), luteinizing hormone (LH) (1), thyrotropin (1), proopiomelanocortin (1) and its cleavage product lipotropin (1), but none of these did significantly differ between feeding groups. Quantification of total pituitary LH and prolactin concentrations by RIA confirmed the results obtained by proteome analysis. Also, feed energy restriction provoked increasing non-esterified fatty acid, decreasing prolactin, but unaltered glucose, LH and growth hormone plasma concentrations. Energy restriction decreased the expression of glial fibrillary acidic protein, triosephosphate isomerase, purine-rich element-binding protein A and elongation factor Tu, whereas it increased expression of proline synthetase co-transcribed homolog, peroxiredoxin III, beta-tubulin and annexin A5 which is involved in the hormone secretion process. Our results indicate that in response to feed energy restriction the pituitary reservoir of all posttranslationally modified hormone forms remains constant. Changing plasma hormone concentrations are likely attributed to a regulated releasing process from the gland into the blood.
Resumo:
OBJECTIVE To validate a radioimmunoassay for measurement of procollagen type III amino terminal propeptide (PIIINP) concentrations in canine serum and bronchoalveolar lavage fluid (BALF) and investigate the effects of physiologic and pathologic conditions on PIIINP concentrations. SAMPLE POPULATION Sera from healthy adult (n = 70) and growing dogs (20) and dogs with chronic renal failure (CRF; 10), cardiomyopathy (CMP; 12), or degenerative valve disease (DVD; 26); and sera and BALF from dogs with chronic bronchopneumopathy (CBP; 15) and healthy control dogs (10 growing and 9 adult dogs). PROCEDURE A radioimmunoassay was validated, and a reference range for serum PIIINP (S-PIIINP) concentration was established. Effects of growth, age, sex, weight, CRF, and heart failure on S-PIIINP concentration were analyzed. In CBP-affected dogs, S-PIIINP and BALF-PIIINP concentrations were evaluated. RESULTS The radioimmunoassay had good sensitivity, linearity, precision, and reproducibility and reasonable accuracy for measurement of S-PIIINP and BALF-PIIINP concentrations. The S-PIIINP concentration reference range in adult dogs was 8.86 to 11.48 mug/L. Serum PIIINP concentration correlated with weight and age. Growing dogs had significantly higher S-PIIINP concentrations than adults, but concentrations in CRF-, CMP-, DVD-, or CBP-affected dogs were not significantly different from control values. Mean BALF-PIIINP concentration was significantly higher in CBP-affected dogs than in healthy adults. CONCLUSIONS AND CLINICAL RELEVANCE In dogs, renal or cardiac disease or CBP did not significantly affect S-PIIINP concentration; dogs with CBP had high BALF-PIIINP concentrations. Data suggest that the use of PIIINP as a marker of pathologic fibrosis might be limited in growing dogs.
Resumo:
Sensitive and precise radioimmunoassays for insulin and glucagon have been established. Although it was possible to employ similar precepts to the development of both hormone assays, the establishment of a reliable glucagon radioimmunoassay was complicated by the poor immunogenicity and instability of the peptide. Thus, unlike insulin antisera which were prepared by monthly injection of guinea pigs with crystalline insulin emulsified in adjuvant, the successful production of glucagon antisera was accomplished by immunisation of rabbits and guinea pigs with glucagon covalently linked to bovine plasma albumin. The conventional chloramine-T iodination with purification by gel chromatography was only suitable for the production of labelled insulin. Quality tracer for use in the glucagon radioimmunoassay was prepared by trace iodination, with subsequent purification of monoiodinated glucagon by anion exchange chromatography. Separation of free and antibody bound moieties by coated charcoal was applicable to both hormone assays, and a computerised data processing system, relying on logit-log transformation, was used to analyse all assay results. The assays were employed to evaluate the regulation of endocrine pancreatic function and the role of insulin and glucagon in the pathogenesis of the obese hyperglycaemic syndrome in mice. In the homozygous (ob/ob) condition, mice of the Birmingham strain were characterised by numerous abnormalities of glucose homeostasis, several of which were detected in heterozygous (ob/+) mice. Obese mice exhibited pancreatic alpha cell dysfunction and hyperglucagonaemia. Investigation of this defect revealed a marked insensitivity of an insulin dependent glucose sensing mechanism that inhibited glucagon secretion. Although circulating glucagon was of minor importance in the maintenance of hyperinsulinaemia, lack of suppression of alpha cell function by glucose and insulin contributed significantly to both the insulin insensitivity and the hyperglycaemia of obese mice.
Resumo:
Studies have examined the associations between cancers and circulating 25-hydroxyvitamin D [25(OH)D], but little is known about the impact of different laboratory practices on 25(OH)D concentrations. We examined the potential impact of delayed blood centrifuging, choice of collection tube, and type of assay on 25(OH)D concentrations. Blood samples from 20 healthy volunteers underwent alternative laboratory procedures: four centrifuging times (2, 24, 72, and 96 h after blood draw); three types of collection tubes (red top serum tube, two different plasma anticoagulant tubes containing heparin or EDTA); and two types of assays (DiaSorin radioimmunoassay [RIA] and chemiluminescence immunoassay [CLIA/LIAISON®]). Log-transformed 25(OH)D concentrations were analyzed using the generalized estimating equations (GEE) linear regression models. We found no difference in 25(OH)D concentrations by centrifuging times or type of assay. There was some indication of a difference in 25(OH)D concentrations by tube type in CLIA/LIAISON®-assayed samples, with concentrations in heparinized plasma (geometric mean, 16.1 ng ml−1) higher than those in serum (geometric mean, 15.3 ng ml−1) (p = 0.01), but the difference was significant only after substantial centrifuging delays (96 h). Our study suggests no necessity for requiring immediate processing of blood samples after collection or for the choice of a tube type or assay.
Resumo:
Objective: To determine whether there are clinical and public health dilemmas resulting from the reproducibility of routine vitamin D assays. Methods: Blinded agreement studies were conducted in eight clinical laboratories using two commonly used assays to measure serum 25-hydroxyvitamin D (25(OH)D) levels in Australasia and Canada (DiaSorin Radioimmunoassay (RIA) and DiaSorin LIAISON® one). Results: Only one laboratory measured 25(OH)D with excellent precision. Replicate 25(OH)D measurements varied by up to 97% and 15% of paired results differed by more than 50%. Thirteen percent of subjects received one result indicating insufficiency [25-50 nmol/l] and another suggesting adequacy [>50 nmol/l]). Agreement ranged from poor to excellent for laboratories using the manual RIA, while the precision of the semi-automated Liaison® system was consistently poor. Conclusions: Recent interest in the relevance of vitamin D to human health has increased demand for 25(OH)D testing and associated costs. Our results suggest clinicians and public health authorities are making decisions about treatment or changes to public health policy based on imprecise data. Clinicians, researchers and policy makers should be made aware of the imprecision of current 25(OH)D testing so that they exercise caution when using these assays for clinical practice, and when interpreting the findings of epidemiological studies based on vitamin D levels measured using these assays. Development of a rapid, reproducible, accurate and robust assay should be a priority due to interest in populationbased screening programs and research to inform public health policy about the amount of sun exposure required for human health. In the interim, 25(OH)D results should routinely include a statement of measurement uncertainty.
Resumo:
The study of biologically active peptides is critical to the understanding of physiological pathways, especially those involved in the development of disease. Historically, the measurement of biologically active endogenous peptides has been undertaken by radioimmunoassay, a highly sensitive and robust technique that permits the detection of physiological concentrations in different biofluid and tissue extracts. Over recent years, a range of mass spectrometric approaches have been applied to peptide quantification with limited degrees of success. Neuropeptide Y (NPY), peptide YY (PYY), and pancreatic polypeptide (PP) belong to the NPY family exhibiting regulatory effects on appetite and feeding behavior. The physiological significance of these peptides depends on their molecular forms and in vivo concentrations systemically and at local sites within tissues. In this report, we describe an approach for quantification of individual peptides within mixtures using high-performance liquid chromatography electrospray ionization tandem mass spectrometry analysis of the NPY family peptides. Aspects of quantification including sample preparation, the use of matrix-matched calibration curves, and internal standards will be discussed. This method for the simultaneous determination of NPY, PYY, and PP was accurate and reproducible but lacks the sensitivity required for measurement of their endogenous concentration in plasma. The advantages of mass spectrometric quantification will be discussed alongside the current obstacles and challenges. © 2012 Wiley Periodicals, Inc. Biopolymers (Pept Sci) 98: 357–366, 2012.