36 resultados para Prestress
Resumo:
Osteocytes respond to dynamic fluid shear loading by activating various biochemical pathways, mediating a dynamic process of bone formation and resorption. Whole-cell deformation and regional deformation of the cytoskeleton may be able to directly regulate this process. Attempts to image cellular deformation by conventional microscopy techniques have been hindered by low temporal or spatial resolution. In this study, we developed a quasi-three-dimensional microscopy technique that enabled us to simultaneously visualize an osteocyte's traditional bottom-view profile and a side-view profile at high temporal resolution. Quantitative analysis of the plasma membrane and either the intracellular actin or microtubule (MT) cytoskeletal networks provided characterization of their deformations over time. Although no volumetric dilatation of the whole cell was observed under flow, both the actin and MT networks experienced primarily tensile strains in all measured strain components. Regional heterogeneity in the strain field of normal strains was observed in the actin networks, especially in the leading edge to flow, but not in the MT networks. In contrast, side-view shear strains exhibited similar subcellular distribution patterns in both networks. Disruption of MT networks caused actin normal strains to decrease, whereas actin disruption had little effect on the MT network strains, highlighting the networks' mechanical interactions in osteocytes.
Resumo:
Pretensioned concrete members are designed and manufactured by using at least two materials: concrete and prestressing reinforcement. Also, two main stages must be considered: prestress transfer and member loading. Hence, the behavior of these members depends strongly on the reinforcement-to-concrete bond performance and prestress losses. In this paper, a testing technique to measure the specific parameters related with the involved phenomena is presented. The testing technique is based on the analysis of series of specimens varying in embedment length to simulate several cross sections at only one end of a pretensioned concrete member. Each specimen is characterized by means of the sequential release of the prestress transfer (detensioning) and the pull-out (loading) operation. The test provides data on prestressing force, transmission length (initial and long-term), anchorage length (without and with slip), reinforcement slips, bond stresses, longitudinal concrete strains, concrete modulus of elasticity, and prestress losses (instantaneous and time-dependent).
Resumo:
This paper presents the results from the experimental investigation on heat activated prestressing of Shape Memory Alloy (SMA) wires for active confinement of concrete sections. Active confinement of concrete is found to be much more effective than passive confinement which becomes effective only when the concrete starts to dilate. Active confinement achieved using conventional prestressing techniques often faces many obstacles due to practical limitations. A class of smart materials that has recently drawn attention in civil engineering is the super elastic SMA which has the ability to undergo reversible hysteretic shape change known as the shape memory effect. The shape memory effect of SMAs can be utilized to develop a convenient prestressing technique for active confinement of concrete sections.
In this study a series of experimental tests are conducted to study Heat Activated Prestress (HAP) in SMAs. Three different types of tests are conducted with different loading protocol to determine parameters such as HAP, residual strain after heating and range of strain that can be used for effective active confinement after HAP. Test results show a maximum HAP of about 500 MPa can be achieved after heating and approximately 450MPa is retained at 25oC in specimens pre-strained by 6%. A substantial amount of strain recovery upon unloading and after heating the SMA wires is recorded. About 2.5% elastic strain recovery upon unloading from 6% strain level is observed. In the specimen pre-strained by 6%, a total of 4% strain is recovered when unloaded after heating. A strain range of 3% is found available for effective confinement after HAP. Test results demonstrate that SMAs have unique features that can be intelligently employed in many civil engineering applications including active confinement of concrete sections.
Resumo:
Trabalho de Projeto para obtenção do grau de Mestre em Engenharia Civil
Resumo:
Trabalho Final de Mestrado para obtenção do grau de Mestre em Engenharia Civil
Resumo:
A prestressed concrete monoblock railroad tie was designed to attend the characteristics of a Brazilian railroad track with 1,600 mm gauge and 320 kN axle load. Concrete ties specimens were manufactured without and with steel fibers in a volume fraction of 60 kg/m3 (0.76 % by volume), and three different initial prestress forces. Static and fatigue tests were carried out on the ties. Static tests showed that steel fibers increase the first crack and ultimate bending moments, increase significantly the slip force of the prestressing tendons, reduce crack width, add higher ductility to the ties and decrease the stress in the prestressing tendons. Under dynamic loading the steel fibers decreased the stress in the prestressing tendons by about 50%, which improved significantly the fatigue strength of the tie. A tie without fibers failed after only 150,000 cycles. However, a similar tie, with fibers, resisted 3,000,000 cycles without suffering fatigue failure.
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
For many years AASHTO provided no recommendation to state DOT’s on bottom flange confinement reinforcement for their bridge superstructures. The 1996 edition of AASHTO Standard Specification for Highway Bridges stated that nominal reinforcement be placed to enclose the prestressing steel from the end of the girder for at least a distance equal to the girder’s height. A few years later the 2004 AASHTO LRFD Bridge Design Specification changed the distance over which the confinement was to be distributed from 1.0h to 1.5h, and gave minimum requirements for the amount of steel to be used, No.3 bars, and their maximum spacing, not to exceed 6”. Research was undertaken to study what impact, if any, confinement reinforcement has on the performance of prestressed concrete bridge girders. Of particular interest was the effect confinement had on the transfer length, development length, and vertical shear capacity of the fore mentioned members. First, an analytical investigation was performed on the subject, and then an experimental investigation followed which consisted of designing, fabricating, and testing eight tee-girders and three NU1100 girders with particular attention paid to the amount and distribution of confinement reinforcement placed at the end of each girder. The results of the study show: 1) neither the amount or distribution of confinement reinforcement had a significant effect on the initial or final transfer length of the prestress strands; 2) at the AASHTO calculated development length, no significant impact from confinement was found on either the nominal flexural capacity of bridge girders or bond capacity of the prestressing steel; 3) the effects from varied confinement reinforcement on the shear resistance of girders tested was negligible, however, distribution of confinement did show to have an impact on the prestressed strands’ bond capacity; 4) confinement distribution across the entire girder did increase ductility and reduced cracking under extreme loading conditions.
Resumo:
The importance of mechanical aspects related to cell activity and its environment is becoming more evident due to their influence in stem cell differentiation and in the development of diseases such as atherosclerosis. The mechanical tension homeostasis is related to normal tissue behavior and its lack may be related to the formation of cancer, which shows a higher mechanical tension. Due to the complexity of cellular activity, the application of simplified models may elucidate which factors are really essential and which have a marginal effect. The development of a systematic method to reconstruct the elements involved in the perception of mechanical aspects by the cell may accelerate substantially the validation of these models. This work proposes the development of a routine capable of reconstructing the topology of focal adhesions and the actomyosin portion of the cytoskeleton from the displacement field generated by the cell on a flexible substrate. Another way to think of this problem is to develop an algorithm to reconstruct the forces applied by the cell from the measurements of the substrate displacement, which would be characterized as an inverse problem. For these kind of problems, the Topology Optimization Method (TOM) is suitable to find a solution. TOM is consisted of an iterative application of an optimization method and an analysis method to obtain an optimal distribution of material in a fixed domain. One way to experimentally obtain the substrate displacement is through Traction Force Microscopy (TFM), which also provides the forces applied by the cell. Along with systematically generating the distributions of focal adhesion and actin-myosin for the validation of simplified models, the algorithm also represents a complementary and more phenomenological approach to TFM. As a first approximation, actin fibers and flexible substrate are represented through two-dimensional linear Finite Element Method. Actin contraction is modeled as an initial stress of the FEM elements. Focal adhesions connecting actin and substrate are represented by springs. The algorithm was applied to data obtained from experiments regarding cytoskeletal prestress and micropatterning, comparing the numerical results to the experimental ones
Resumo:
The use of guided ultrasonic waves (GUW) has increased considerably in the fields of non-destructive (NDE) testing and structural health monitoring (SHM) due to their ability to perform long range inspections, to probe hidden areas as well as to provide a complete monitoring of the entire waveguide. Guided waves can be fully exploited only once their dispersive properties are known for the given waveguide. In this context, well stated analytical and numerical methods are represented by the Matrix family methods and the Semi Analytical Finite Element (SAFE) methods. However, while the former are limited to simple geometries of finite or infinite extent, the latter can model arbitrary cross-section waveguides of finite domain only. This thesis is aimed at developing three different numerical methods for modelling wave propagation in complex translational invariant systems. First, a classical SAFE formulation for viscoelastic waveguides is extended to account for a three dimensional translational invariant static prestress state. The effect of prestress, residual stress and applied loads on the dispersion properties of the guided waves is shown. Next, a two-and-a-half Boundary Element Method (2.5D BEM) for the dispersion analysis of damped guided waves in waveguides and cavities of arbitrary cross-section is proposed. The attenuation dispersive spectrum due to material damping and geometrical spreading of cavities with arbitrary shape is shown for the first time. Finally, a coupled SAFE-2.5D BEM framework is developed to study the dispersion characteristics of waves in viscoelastic waveguides of arbitrary geometry embedded in infinite solid or liquid media. Dispersion of leaky and non-leaky guided waves in terms of speed and attenuation, as well as the radiated wavefields, can be computed. The results obtained in this thesis can be helpful for the design of both actuation and sensing systems in practical application, as well as to tune experimental setup.
Resumo:
Activity of clotting factor VIII has been shown to acutely increase with sympathetic nervous system stimulation. We investigated whether aspirin and propranolol affect the responsiveness of plasma clotting factor VIII activity levels to acute psychosocial stress. We randomized 54 healthy subjects double-blind to 5-day treatment with a single daily oral dosage of either 100 mg aspirin plus 80 mg propranolol combined, 100 mg of aspirin, 80 mg of propranolol, or placebo medication. Thereafter, subjects underwent a 13-min standardized psychosocial stressor. Plasma levels of clotting factor VIII activity were determined immediately before, immediately after, 45 min and 105 min after stress. Controlling for demographic, metabolic, and life style factors repeated measures analysis of covariance showed that the change in clotting factor VIII activity from prestress to 105 min poststress differed between medication groups (P = 0.023; partial eta = 0.132). The clotting factor VIII activity level decreased from prestress to immediately poststress in the aspirin/propranolol group relative to the placebo group (P = 0.048) and the aspirin group (P < 0.06). Between 45 min and 105 min poststress, clotting factor VIII levels increased in the aspirin/propranolol group relative to the placebo group (P = 0.007) and the aspirin group (P = 0.039). The stress response in clotting factor VIII activity levels was not significantly different between the aspirin/propranolol group and the propranolol group. Propranolol in combination with aspirin diminished the acute response in clotting factor VIII activity to psychosocial stress compared with placebo medication and aspirin alone. The effect of single aspirin on the acute clotting factor VIII stress response was indistinguishable from a placebo effect.
Resumo:
Flat or worn wheels rolling on rough or corrugated tracks can provoke airborne noise and ground-borne vibration, which can be a serious concern for nearby neighbours of urban rail transit lines. Among the various treatments used to reduce vibration and noise, resilient wheels play an important role. In conventional resilient wheels, a slightly prestressed Vshaped rubber ring is mounted between the steel wheel centre and tyre. The elastic layer enhances rolling noise and vibration suppression, as well as impact reduction on the track. In this paper the effectiveness of resilient wheels in underground lines, in comparison to monobloc ones, is assessed. The analysed resilient wheel is able to carry greater loads than standard resilient wheels used for light vehicles. It also presents a greater radial resiliency and a higher axial stiffness than conventional Vwheels. The finite element method was used in this study. A quarter car model was defined, in which the wheelset was modelled as an elastic body. Several simulations were performed in order to assess the vibrational behaviour of elastic wheels, including modal, harmonic and random vibration analysis, the latter allowing the introduction of realistic vertical track irregularities, as well as the influence of the running speed. Due to numerical problems some simplifications were needed. Parametric variations were also performed, in which the sensitivity of the whole system to variations of rubber prestress and Poisson’s ratio of the elastic material was assessed.Results are presented in the frequency domain, showing a better performance of the resilient wheels for frequencies over 200 Hz. This result reveals the ability of the analyzed design to mitigate rolling noise, but not structural vibrations, which are primarily found in the lower frequency range.
Resumo:
Las piezas pretensadas de hormigón presentan zonas muy solicitadas correspondientes a la zona de transferencia. En muchos casos se ha detectado figuración en tales zonas cuyo origen está ligado a la transferencia de la fuerza de pretensado, pudiendo llegar a causar el rechazo de la pieza. En el caso de las piezas prefabricadas con armaduras pretesas adherentes, no siempre es posible disponer armado transversal para controlar esta fisuración, ya sea por el proceso constructivo, ya sea por disponer en general de secciones transversales muy optimizadas. Recientemente se desarrolló una nueva tipología de piezas de hormigón prefabricado para forjados unidireccionales pretensadas con armadura activa pretesa y sin armadura transversal. La tipología se asimila a una sección en PI invertida, con alas de gran envergadura en comparación con el ancho de nervio, y armadura activa distribuida en las alas. Este diseño parece propenso a la aparición de fisuración en el momento de la transferencia del pretensado. Así, se han producido fallos de carácter frágil: colapso de piezas ya colocadas en obra, separándose la losa inferior de los nervios y cayendo sobre el piso. Las herramientas de análisis usuales han resultado inútiles al aplicarse a la investigación de esta patología. Para afrontar el estudio de los problemas detectados en la tipología, se ha analizado el fenómeno de las tensiones de tracción en la zona de transferencia, usualmente denominadas exfoliación y estallido, así como los métodos de análisis aplicables a elementos pretesos sin armadura transversal. En algunas ocasiones se trata del resultado de trabajos desarrollados para piezas postesadas, o para calcular cuantías de armadura transversal, adaptados a posteriori. También existen métodos desarrollados específicamente para piezas pretesas sin armadura transversal. Junto a los factores considerados en los métodos existentes se han localizado otros, no tenidos en cuenta habitualmente, pero que pueden ser determinantes en piezas no convencionales, como son: la existencia de pretensado superior e inferior, la falta de simetría de la sección transversal, el ancho variable de las piezas, una relación entre el ancho del ala y el espesor de los nervios elevada, la distribución transversal del pretensado en relación al ancho variable. Además, la mayoría de los métodos se han basado en simplificaciones bidimensionales. Para tener en cuenta la influencia de estos factores, se han modelizado piezas en las que varían tanto la geometría de la sección transversal y la cuantía de pretensado, como la ley de adherencia o la distribución de armadura activa en la sección. Estos modelos se han analizado mediante el método de elementos finitos, efectuándose u análisis elástico lineal tridimensional. En general, los métodos existentes no han predicho adecuadamente las tensiones obtenidas mediante elementos finitos. Sobre los resultados obtenidos por elementos finitos se ha desarrollado un ajuste experimental, que presentan un alto grado de correlación y de significación, así como una reducida dispersión y error relativo. En consecuencia, se propone un método de obtención de la tensión máxima de exfoliación, consistente en varias ecuaciones, que tienen en cuenta las peculiaridades de la configuración de las piezas citadas y permiten considerar cualquier ley de adherencia, manteniendo la coherencia con la longitud de transmisión. Las ecuaciones se emplean para la obtención de la tensión máxima de exfoliación en piezas de la tipología estudiada cuya armadura activa se sitúe fuera del núcleo central de la sección transversal. Respecto al estallido, se propone una modificación de los métodos existentes que, comparado con los resultados del análisis por elementos finitos, mejora el valor medio y la dispersión a valores admisibles y del lado de la seguridad. El método considera la geometría de la sección y la distribución del pretensado en la losa inferior. Finalmente, se ofrecen estrategias de diseño para piezas de la tipología o semejantes. End zones of prestressed concrete members are highly stressed. Cracking have often appeared at end zone, and its beginning is related to prestress release. Some members become rejected because of these cracks. Sometimes it is not possible having transverse reinforcement in order to control cracking, when referring to pretensioned precast members. The reason may be the construction process or highly optimized crosssections. A new typology of precast concrete members designed for one-way composite floors was recently developed. The members, without transverse reinforcement, are prestressed with pretensioned wires or strands. This typology is similar to an inverted TT slab, with a large flange related to the web thickness and prestressing reinforcement spread across the flange. This design is highly susceptible to appear cracking at prestress release. Therefore, brittle failures have been reported: fail of slabs laid in place on a construction site, resulting in the separation of the flange from the webs,, and the subsequent fall on the lower floor. Usual analytical methods have been useless to study the failure. End zone tensile stresses have been analysed to study the detected typology problems. These tensile stresses are usually called spalling and bursting (also called splitting in the U.S.). Analysis methods applicable to pretensioned members without transverse reinforcement have been analysed too. Some methods were originally developed for postensioned concrete or for obtaining the amount of transverse reinforcement. In addition, there are methods developed specifically for pretensioned members without transverse reinforcement. Some factors, frequently ignored, have been found, such as lower and upper prestress, lack of symmetry in the cross section, variable width, a high ratio between flange width and web thickness or prestressing reinforcement location related to variable width. They can play a decisive role in non-conventional members. In addition, most methods are based on 2D simplifications. Finite Element modelling has been conducted in order to consider the influence of these factors. A linear 3D approach has been used. The modelled members vary according to cross section geometry, bond behaviour, or prestressing reinforcement location. In general, the obtained tensile stresses don’t agree with existing methods. An experimental adjustment has been conducted on the obtained results, with a high correlation ratio and significance level as well as a low dispersion and relative error. Therefore, a method to obtain the maximum spalling stress is proposed. The proposal consists on some equations that consider the special features of the typology and bond behaviour. Consistency between transmission length and bond behaviour is considered too. The equations are used to calculate maximum spalling stress for the studied typology members whose prestressing reinforcement is located out of the core of the cross section. In relation to bursting, a modification of existing methods is proposed. Compared to finite element results, the proposal improves mean value and dispersion, whose ranges are considered acceptable and secure. The method takes into account cross section geometry and location of prestressing reinforcement across the lower flange. Finally, strategies to design members of this typology or similar are proposed.
Resumo:
El empleo de los micropilotes en la ingeniería civil ha revolucionado las técnicas de estabilización de terraplenes a media ladera, ya que aunque los pilotes pueden ser la opción más económica, el uso de micropilotes permite llegar a sitios inaccesibles con menor coste de movimientos de tierras, realización de plataformas de trabajo de dimensiones reducidas, maquinaria necesaria es mucho más pequeña, liviana y versátil en su uso, incluyendo la posibilidad de situar la fabricación de morteros o lechadas a distancias de varias decenas de metros del elemento a ejecutar. Sin embargo, realizando una revisión de la documentación técnica que se tiene en el ámbito ingenieril, se comprobó que los sistemas de diseño de algunos casos (micropilotes en terraplenes a media ladera, micropilotes en pantallas verticales, micropilotes como “paraguas” en túneles, etc.) eran bastante deficientes o poco desarrollados. Premisa que permite concluir que el constructor ha ido por delante (como suele ocurrir en ingeniería geotécnica) del cálculo o de su análisis teórico. Del mismo modo se determinó que en su mayoría los micropilotes se utilizan en labores de recalce o como nueva solución de cimentación en condiciones de difícil acceso, casos en los que el diseño de los micropilotes viene definido por cargas axiales, de compresión o de tracción, consideraciones que se contemplan en reglamentaciones como la “Guía para el proyecto y la ejecución de micropilotes en obras de carretera” del Ministerio de Fomento. En los micropilotes utilizados para estabilizar terraplenes a media ladera y micropilotes actuando como muros pantalla, en los que éstos trabajan a esfuerzo cortante y flexión, no se dispone de sistemas de análisis fiables o no se introduce adecuadamente el problema de interacción terreno-micropilote. Además en muchos casos, los parámetros geotécnicos que se utilizan no tienen una base técnico-teórica adecuada por lo que los diseños pueden quedar excesivamente del lado de la seguridad, en la mayoría de los casos, o todo lo contrario. Uno de los objetivos principales de esta investigación es estudiar el comportamiento de los micropilotes que están sometidos a esfuerzos de flexión y cortante, además de otros objetivos de gran importancia que se describen en el apartado correspondiente de esta tesis. Cabe indicar que en este estudio no se ha incluido el caso de micropilotes quasi-horizontales trabajando a flexion (como los “paraguas” en túneles), por considerarse que estos tienen un comportamiento y un cálculo diferente, que está fuera del alcance de esta investigación. Se ha profundizado en el estudio del empleo de micropilotes en taludes, presentando casos reales de obras ejecutadas, datos estadísticos, problemas de diseño y ejecución, métodos de cálculo simplificados y modelación teórica en cada caso, efectuada mediante el empleo de elementos finitos con el Código Plaxis 2D. Para llevar a cabo los objetivos que se buscan con esta investigación, se ha iniciado con el desarrollo del “Estado del Arte” que ha permitido establecer tipología, aplicaciones, características y cálculo de los micropilotes que se emplean habitualmente. Seguidamente y a efectos de estudiar el problema dentro de un marco geotécnico real, se ha seleccionado una zona española de actuación, siendo ésta Andalucía, en la que se ha utilizado de manera muy importante la técnica de micropilotes sobre todo en problemas de estabilidad de terraplenes a media ladera. A partir de ahí, se ha realizado un estudio de las propiedades geotécnicas de los materiales (principalmente suelos y rocas muy blandas) que están presentes en esta zona geográfica, estudio que ha sido principalmente bibliográfico o a partir de la experiencia en la zona del Director de esta tesis. Del análisis realizado se han establecido ordenes de magnitud de los parámetros geotécnicos, principalmente la cohesión y el ángulo de rozamiento interno (además del módulo de deformación aparente o de un módulo de reacción lateral equivalente) para los diversos terrenos andaluces. Con el objeto de conocer el efecto de la ejecución de un micropilote en el terreno (volumen medio real del micropilote, una vez ejecutado; efecto de la presión aplicada en las propiedades del suelo circundante, etc.) se ha realizado una encuesta entre diversas empresas españolas especializadas en la técnica de los micropilotes, a efectos de controlar los volúmenes de inyección y las presiones aplicadas, en función de la deformabilidad del terreno circundante a dichos micropilotes, con lo que se ha logrado definir una rigidez a flexión equivalente de los mismos y la definición y características de una corona de terreno “mejorado” lograda mediante la introducción de la lechada y el efecto de la presión alrededor del micropilote. Con las premisas anteriores y a partir de los parámetros geotécnicos determinados para los terrenos andaluces, se ha procedido a estudiar la estabilidad de terraplenes apoyados sobre taludes a media ladera, mediante el uso de elementos finitos con el Código Plaxis 2D. En el capítulo 5. “Simulación del comportamiento de micropilotes estabilizando terraplenes”, se han desarrollado diversas simulaciones. Para empezar se simplificó el problema simulando casos similares a algunos reales en los que se conocía que los terraplenes habían llegado hasta su situación límite (de los que se disponía información de movimientos medidos con inclinómetros), a partir de ahí se inició la simulación de la inestabilidad para establecer el valor de los parámetros de resistencia al corte del terreno (mediante un análisis retrospectivo – back-análisis) comprobando a su vez que estos valores eran similares a los deducidos del estudio bibliográfico. Seguidamente se han introducido los micropilotes en el borde de la carretera y se ha analizado el comportamiento de éstos y del talud del terraplén (una vez construidos los micropilotes), con el objeto de establecer las bases para su diseño. De este modo y adoptando los distintos parámetros geotécnicos establecidos para los terrenos andaluces, se simularon tres casos reales (en Granada, Málaga y Ceuta), comparando los resultados de dichas simulaciones numéricas con los resultados de medidas reales de campo (desplazamientos del terreno, medidos con inclinómetros), obteniéndose una reproducción bastante acorde a los movimientos registrados. Con las primeras simulaciones se concluye que al instalar los micropilotes la zona más insegura de la ladera es la de aguas abajo. La superficie de rotura ya no afecta a la calzada que protegen los micropilotes. De ahí que se deduzca que esta solución sea válida y se haya aplicado masivamente en Andalucía. En esas condiciones, podría decirse que no se está simulando adecuadamente el trabajo de flexión de los micropilotes (en la superficie de rotura, ya que no les corta), aunque se utilicen elementos viga. Por esta razón se ha realizado otra simulación, basada en las siguientes hipótesis: − Se desprecia totalmente la masa potencialmente deslizante, es decir, la que está por delante de la fila exterior de micros. − La estratigrafía del terreno es similar a la considerada en las primeras simulaciones. − La barrera de micropilotes está constituida por dos elementos inclinados (uno hacia dentro del terraplén y otro hacia fuera), con inclinación 1(H):3(V). − Se puede introducir la rigidez del encepado. − Los micros están separados 0,556 m ó 1,00 m dentro de la misma alineación. − El empotramiento de los micropilotes en el sustrato resistente puede ser entre 1,5 y 7,0 m. Al “anular” el terreno que está por delante de los micropilotes, a lo largo del talud, estos elementos empiezan claramente a trabajar, pudiendo deducirse los esfuerzos de cortante y de flexión que puedan actuar sobre ellos (cota superior pero prácticamente muy cerca de la solución real). En esta nueva modelación se ha considerado tanto la rigidez equivalente (coeficiente ϴ) como la corona de terreno tratado concéntrico al micropilote. De acuerdo a esto último, y gracias a la comparación de estas modelaciones con valores reales de movimientos en laderas instrumentadas con problemas de estabilidad, se ha verificado que existe una similitud bastante importante entre los valores teóricos obtenidos y los medidos en campo, en relación al comportamiento de los micropilotes ejecutados en terraplenes a media ladera. Finalmente para completar el análisis de los micropilotes trabajando a flexión, se ha estudiado el caso de micropilotes dispuestos verticalmente, trabajando como pantallas discontinuas provistas de anclajes, aplicado a un caso real en la ciudad de Granada, en la obra “Hospital de Nuestra Señora de la Salud”. Para su análisis se utilizó el código numérico CYPE, basado en que la reacción del terreno se simula con muelles de rigidez Kh o “módulo de balasto” horizontal, introduciendo en la modelación como variables: a) Las diferentes medidas obtenidas en campo; b) El espesor de terreno cuaternario, que por lo que se pudo determinar, era variable, c) La rigidez y tensión inicial de los anclajes. d) La rigidez del terreno a través de valores relativos de Kh, recopilados en el estudio de los suelos de Andalucía, concretamente en la zona de Granada. Dicha pantalla se instrumentó con 4 inclinómetros (introducidos en los tubos de armadura de cuatro micropilotes), a efectos de controlar los desplazamientos horizontales del muro de contención durante las excavaciones pertinentes, a efectos de comprobar la seguridad del conjunto. A partir del modelo de cálculo desarrollado, se ha comprobado que el valor de Kh pierde importancia debido al gran número de niveles de anclajes, en lo concerniente a las deformaciones horizontales de la pantalla. Por otro lado, los momentos flectores son bastante sensibles a la distancia entre anclajes, al valor de la tensión inicial de los mismos y al valor de Kh. Dicho modelo también ha permitido reproducir de manera fiable los valores de desplazamientos medidos en campo y deducir los parámetros de deformabilidad del terreno, Kh, con valores del orden de la mitad de los medidos en el Metro Ligero de Granada, pero visiblemente superiores a los deducibles de ábacos que permiten obtener Kh para suelos granulares con poca cohesión (gravas y cuaternario superior de Sevilla) como es el caso del ábaco de Arozamena, debido, a nuestro juicio, a la cementación de los materiales presentes en Granada. En definitiva, de las anteriores deducciones se podría pensar en la optimización del diseño de los micropilotes en las obras que se prevean ejecutar en Granada, con similares características al caso de la pantalla vertical arriostrada mediante varios niveles de anclajes y en las que los materiales de emplazamiento tengan un comportamiento geotécnico similar a los estudiados, con el consiguiente ahorro económico. Con todo ello, se considera que se ha hecho una importante aportación para el diseño de futuras obras de micropilotes, trabajando a flexión y cortante, en obras de estabilización de laderas o de excavaciones. Using micropiles in civil engineering has transformed the techniques of stabilization of embankments on the natural or artificial slopes, because although the piles may be the cheapest option, the use of micropiles can reach inaccessible places with lower cost of earthworks, carrying out small work platforms. Machinery used is smaller, lightweight and versatile, including the possibility of manufacturing mortars or cement grouts over distances of several tens of meters of the element to build. However, making a review of the technical documentation available in the engineering field, it was found that systems designed in some cases (micropiles in embankments on the natural slopes, micropiles in vertical cut-off walls, micropiles like "umbrella" in tunnels, etc.) were quite poor or underdeveloped. Premise that concludes the builder has gone ahead (as usually happen in geotechnical engineering) of calculation or theoretical analysis. In the same way it was determined that most of the micropiles are used in underpinning works or as a new foundation solution in conditions of difficult access, in which case the design of micropiles is defined by axial, compressive or tensile loads, considered in regulations as the " Handbook for the design and execution of micropiles in road construction" of the Ministry of Development. The micropiles used to stabilize embankments on the slopes and micropiles act as retaining walls, where they work under shear stress and bending moment, there are not neither reliable systems analysis nor the problem of soil-micropile interaction are properly introduced. Moreover, in many cases, the geotechnical parameters used do not have a proper technical and theoretical basis for what designs may be excessively safe, or the opposite, in most cases. One of the main objectives of this research is to study the behavior of micro piles which are subjected to bending moment and shear stress, as well as other important objectives described in the pertinent section of this thesis. It should be noted that this study has not included the case of quasi-horizontal micropiles working bending moment (as the "umbrella" in tunnels), because it is considered they have a different behavior and calculation, which is outside the scope of this research. It has gone in depth in the study of using micropiles on slopes, presenting real cases of works made, statistics, problems of design and implementation, simplified calculation methods and theoretical modeling in each case, carried out by using FEM (Finite Element Method) Code Plaxis 2D. To accomplish the objectives of this research, It has been started with the development of the "state of the art" which stipulate types, applications, characteristics and calculation of micropiles that are commonly used. In order to study the problem in a real geotechnical field, it has been selected a Spanish zone of action, this being Andalusia, in which it has been used in a very important way, the technique of micropiles especially in embankments stability on natural slopes. From there, it has made a study of the geotechnical properties of the materials (mainly very soft soils and rocks) that are found in this geographical area, which has been mainly a bibliographic study or from the experience in the area of the Director of this thesis. It has been set orders of magnitude of the geotechnical parameters from analyzing made, especially the cohesion and angle of internal friction (also apparent deformation module or a side reaction module equivalent) for various typical Andalusian ground. In order to determine the effect of the implementation of a micropile on the ground (real average volume of micropile once carried out, effect of the pressure applied on the properties of the surrounding soil, etc.) it has conducted a survey among various skilled companies in the technique of micropiles, in order to control injection volumes and pressures applied, depending on the deformability of surrounding terrain such micropiles, whereby it has been possible to define a bending stiffness and the definition and characteristics of a crown land "improved" achieved by introducing the slurry and the effect of the pressure around the micropile. With the previous premises and from the geotechnical parameters determined for the Andalusian terrain, we proceeded to study the stability of embankments resting on batters on the slope, using FEM Code Plaxis 2D. In the fifth chapter "Simulation of the behavior of micropiles stabilizing embankments", there were several different numerical simulations. To begin the problem was simplified simulating similar to some real in which it was known that the embankments had reached their limit situation (for which information of movements measured with inclinometers were available), from there the simulation of instability is initiated to set the value of the shear strength parameters of the ground (by a retrospective analysis or back-analysis) checking these values were similar to those deduced from the bibliographical study Then micropiles have been introduced along the roadside and its behavior was analyzed as well as the slope of embankment (once micropiles were built ), in order to establish the basis for its design. In this way and taking the different geotechnical parameters for the Andalusian terrain, three real cases (in Granada, Malaga and Ceuta) were simulated by comparing the results of these numerical simulations with the results of real field measurements (ground displacements measured with inclinometers), getting quite consistent information according to registered movements. After the first simulations it has been concluded that after installing the micropiles the most insecure area of the natural slope is the downstream. The failure surface no longer affects the road that protects micropiles. Hence it is inferred that this solution is acceptable and it has been massively applied in Andalusia. Under these conditions, one could say that it is not working properly simulating the bending moment of micropiles (on the failure surface, and that does not cut them), although beam elements are used. Therefore another simulation was performed based on the following hypotheses: − The potentially sliding mass is totally neglected, that is, which is ahead of the outer row of micropiles. − Stratigraphy field is similar to the one considered in the first simulations. − Micropiles barrier is constituted by two inclined elements (one inward and one fill out) with inclination 1 (H): 3 (V). − You can enter the stiffness of the pile cap. − The microlies lines are separated 0.556 m or 1.00 m in the same alignment. − The embedding of the micropiles in the tough substrate can be between 1.5 and 7.0 m. To "annul" the ground that is in front of the micro piles, along the slope, these elements clearly start working, efforts can be inferred shear stress and bending moment which may affect them (upper bound but pretty close to the real) solution. In this new modeling it has been considered both equivalent stiffness coefficient (θ) as the treated soil crown concentric to the micropile. According to the latter, and by comparing these values with real modeling movements on field slopes instrumented with stability problems, it was verified that there is quite a significant similarity between the obtained theoretical values and the measured field in relation to the behavior of micropiles executed in embankments along the natural slope. Finally to complete the analysis of micropiles working in bending conditions, we have studied the case of micropiles arranged vertically, working as discontinued cut-off walls including anchors, applied to a real case in the city of Granada, in the play "Hospital of Our Lady of the Health ". CYPE numeric code, based on the reaction of the ground is simulated spring stiffness Kh or "subgrade" horizontal, introduced in modeling was used as variables for analysis: a) The different measurements obtained in field; b) The thickness of quaternary ground, so that could be determined, was variable, c) The stiffness and the prestress of the anchors. d) The stiffness of the ground through relative values of Kh, collected in the study of soils in Andalusia, particularly in the area of Granada. (previously study of the Andalusia soils) This cut-off wall was implemented with 4 inclinometers (introduced in armor tubes four micropiles) in order to control the horizontal displacements of the retaining wall during the relevant excavations, in order to ensure the safety of the whole. From the developed model calculation, it was found that the value of Kh becomes less important because a large number of anchors levels, with regard to the horizontal deformation of the cut-off wall. On the other hand, the bending moments are quite sensitive to the distance between anchors, the initial voltage value thereof and the value of Kh. This model has also been reproduced reliably displacement values measured in the field and deduce parameters terrain deformability, Kh, with values around half the measured Light Rail in Granada, but visibly higher than deductible of abacuses which can obtain Kh for granular soils with low cohesion (upper Quaternary gravels and Sevilla) such as Abacus Arozamena, because, in our view, to cementing materials in Granada. In short, previous deductions you might think on optimizing the design of micropiles in the works that are expected to perform in Granada, with similar characteristics to the case of the vertical cut-off wall braced through several levels of anchors and in which materials location have a geotechnical behavior similar to those studied, with the consequent economic savings. With all this, it is considered that a significant contribution have been made for the design of future works of micropiles, bending moment and shear stress working in slope stabilization works or excavations.
Resumo:
Alternative models of cell mechanics depict the living cell as a simple mechanical continuum, porous filament gel, tensed cortical membrane, or tensegrity network that maintains a stabilizing prestress through incorporation of discrete structural elements that bear compression. Real-time microscopic analysis of cells containing GFP-labeled microtubules and associated mitochondria revealed that living cells behave like discrete structures composed of an interconnected network of actin microfilaments and microtubules when mechanical stresses are applied to cell surface integrin receptors. Quantitation of cell tractional forces and cellular prestress by using traction force microscopy confirmed that microtubules bear compression and are responsible for a significant portion of the cytoskeletal prestress that determines cell shape stability under conditions in which myosin light chain phosphorylation and intracellular calcium remained unchanged. Quantitative measurements of both static and dynamic mechanical behaviors in cells also were consistent with specific a priori predictions of the tensegrity model. These findings suggest that tensegrity represents a unified model of cell mechanics that may help to explain how mechanical behaviors emerge through collective interactions among different cytoskeletal filaments and extracellular adhesions in living cells.