983 resultados para Pressure Support Ventilation
Resumo:
Neurally adjusted ventilatory assist (NAVA) is a ventilation assist mode that delivers pressure in proportionality to electrical activity of the diaphragm (Eadi). Compared to pressure support ventilation (PS), it improves patient-ventilator synchrony and should allow a better expression of patient's intrinsic respiratory variability. We hypothesize that NAVA provides better matching in ventilator tidal volume (Vt) to patients inspiratory demand. 22 patients with acute respiratory failure, ventilated with PS were included in the study. A comparative study was carried out between PS and NAVA, with NAVA gain ensuring the same peak airway pressure as PS. Robust coefficients of variation (CVR) for Eadi and Vt were compared for each mode. The integral of Eadi (ʃEadi) was used to represent patient's inspiratory demand. To evaluate tidal volume and patient's demand matching, Range90 = 5-95 % range of the Vt/ʃEadi ratio was calculated, to normalize and compare differences in demand within and between patients and modes. In this study, peak Eadi and ʃEadi are correlated with median correlation of coefficients, R > 0.95. Median ʃEadi, Vt, neural inspiratory time (Ti_ ( Neural )), inspiratory time (Ti) and peak inspiratory pressure (PIP) were similar in PS and NAVA. However, it was found that individual patients have higher or smaller ʃEadi, Vt, Ti_ ( Neural ), Ti and PIP. CVR analysis showed greater Vt variability for NAVA (p < 0.005). Range90 was lower for NAVA than PS for 21 of 22 patients. NAVA provided better matching of Vt to ʃEadi for 21 of 22 patients, and provided greater variability Vt. These results were achieved regardless of differences in ventilatory demand (Eadi) between patients and modes.
Resumo:
The spontaneous breathing trial (SBT)-relying on objective criteria assessed by the clinician-is the major diagnostic tool to determine if patients can be successfully extubated. However, little is known regarding the patient's subjective perception of autonomous breathing. We performed a prospective observational study in 211 mechanically ventilated adult patients successfully completing a SBT. Patients were randomly assigned to be interviewed during this trial regarding their prediction of extubation success. We compared post-extubation outcomes in three patient groups: patients confident (confidents; n = 115) or not (non-confidents; n = 38) of their extubation success and patients not subjected to interview (control group; n = 58). Extubation success was more frequent in confidents than in non-confidents (90 vs. 45%; p < 0.001/positive likelihood ratio = 2.00) or in the control group (90 vs. 78%; p = 0.04). On the contrary, extubation failure was more common in non-confidents than in confidents (55 vs. 10%; p < 0.001/negative likelihood ratio = 0.19). Logistic regression analysis showed that extubation success was associated with patient's prediction [OR (95% CI): 9.2 (3.74-22.42) for confidents vs.non-confidents] as well as to age [0.72 (0.66-0.78) for age 75 vs. 65 and 1.31 (1.28-1.51) for age 55 vs. 65]. Our data suggest that at the end of a sustained SBT, extubation success might be correlated to the patients' subjective perception of autonomous breathing. The results of this study should be confirmed by a large multicenter trial.
Resumo:
ABSTRACT: Conventional mechanical ventilators rely on pneumatic pressure and flow sensors and controllers to detect breaths. New modes of mechanical ventilation have been developed to better match the assistance delivered by the ventilator to the patient's needs. Among these modes, neurally adjusted ventilatory assist (NAVA) delivers a pressure that is directly proportional to the integral of the electrical activity of the diaphragm recorded continuously through an esophageal probe. In clinical settings, NAVA has been chiefly compared with pressure-support ventilation, one of the most popular modes used during the weaning phase, which delivers a constant pressure from breath to breath. Comparisons with proportional-assist ventilation, which has numerous similarities, are lacking. Because of the constant level of assistance, pressure-support ventilation reduces the natural variability of the breathing pattern and can be associated with asynchrony and/or overinflation. The ability of NAVA to circumvent these limitations has been addressed in clinical studies and is discussed in this report. Although the underlying concept is fascinating, several important questions regarding the clinical applications of NAVA remain unanswered. Among these questions, determining the optimal NAVA settings according to the patient's ventilatory needs and/or acceptable level of work of breathing is a key issue. In this report, based on an investigator-initiated round table, we review the most recent literature on this topic and discuss the theoretical advantages and disadvantages of NAVA compared with other modes, as well as the risks and limitations of NAVA.
Resumo:
Objetivo: Caracterizar a los pacientes que recibieron ventilación mecánica en las unidades de cuidado intensivo (UCI) de la Fundación Santa Fe de Bogotá entre los años 2009 y 2013. Metodología: Se analizó una cohorte retrospectiva de los pacientes en UCI que requirieron soporte ventilatorio mecánico al ingreso a la unidad independientemente de la causa. Resultados: La media de edad de los pacientes fue 63,83 años; el diagnóstico más frecuente de ingreso fue revascularización miocárdica, seguido por neumonía y recambio valvular aórtico; en el 43% de los casos la causa de la falla fue el estado postoperatorio. Los modos ventilatorios más frecuentemente utilizados fueron SIMV (27,5%) y ventilación asistida controlada (26,12%). El 50% de los pacientes fueron ventilados con PEEP < 6 cmH2O. La mortalidad bruta fue del 15%. 22% de los pacientes tuvieron estancia prolongada en UCI. Se aplicó protocolo de retiro de ventilación mecánica en el 77% de los pacientes. La duración de la ventilación mecánica es mayor a medida que aumenta la edad del paciente entre los 60 y los 80 años. La mortalidad es cercana al 50% alrededor de los 50 años y mayor a 80% después de los 80 años. El soporte ventilatorio por cinco o más días aumentó la mortalidad a 80% o más. Discusión y Conclusiones: Estos resultados son comparables a los encontrados en estudios previos. Este estudio puede ser considerado como el primer paso para generar un registro adecuado de la ventilación de la mecánica de las unidades de cuidado intensivo del país.
Variación en la resistencia al flujo de los tubos endotraqueales pediátricos modificando su longitud
Resumo:
Introducción: Se conocen los beneficios del uso de los tubos endotraqueales con neumotaponador, aunque dicha práctica tiene un impacto sobre el trabajo respiratorio durante el acto anestésico sin embargo se propone estudiar las consecuencias físicas de la variación en la longitud de los tubos para compensar dicha perdida de flujo, con base en la ley de Hagen-Poiseuille. Metodología: Se realizó un estudio experimental in vitro, en el cual se realizaron mediciones repetidas de flujo, variando la longitud y diámetro de diferentes tubos endotraqueales pediátricos (desde calibre 3.5mm hasta 6.5mm), con longitudes de 20cm, 15 cm, 10 cm y manteniendo su longitud original. Se analizaron los datos con el fin de medir el impacto sobre el flujo. Resultados: A pesar que los resultados muestran diferencias estadísticamente significativas (p0,000), la variación en la longitud de los tubos endotraqueales pediátricos tiene mucho menor impacto sobre la variación en el flujo, que la modificación del diámetro. Discusión: Si bien la práctica de acortar la longitud de un tubo endotraqueal pediátrico puede ayudar a reducir el espacio muerto y la retención de CO2, el impacto que tiene sobre el flujo es poco. Cuando se trata de disminuir el trabajo respiratorio de un niño en ventilación espontánea durante el acto anestésico, se debe escoger de forma apropiada el calibre de tubo correspondiente para la edad.
Resumo:
Introdução: O uso da pressão expiratória positiva na via aérea (EPAP) não é sugerido como técnica de desmame. O EPAP pode previnir o colapso das vias aéreas durante a expiração. Objetivo: O objetivo deste trabalho é verificar se a utilização da pressão expiratória positiva na via aérea (EPAP) apresenta benefícios na redução da hiperinsuflação dinâmica com redução do trabalho respiratório e melhora da oxigenação em pacientes submetidos ao processo de desmame da ventilação mecânica. Material e Métodos: Quarenta pacientes submetidos à ventilação mecânica por um período maior que 48 horas em 2 unidades de terapia intensiva foram avaliados prospectivamente em um estudo randomizado controlado cruzado. Todos os pacientes foram submetidos métodos de ventilação de pressão de suporte (PSV), tubo-t e EPAP, durante 30 minutos, com um período de descanso de 30 minutos entre cada método. Os pacientes foram monitorizados pelo VenTrack (Novametrix, EUA). As variáveis estudadas, mensuradas no minuto 1, 15 e 30, foram: PEEP intínseca (PEEPi), trabalho respiratório (WOBtotal), frequência respiratória (f), volume de ar corrente (Vt) e saturação periférica de oxigênio (SaO2). A amostra geral foi analisada e dividida em subgrupos DPOC (n= 14) e não-DPOC (n=26), traqueostomizados (n=15) e não-traqueostomizados (n=25). As comparações foram feitas pela Análise de Variância (ANOVA) e teste-t. O nível de significância foi de 95%. Resultados: PEEPi DPOC e não-DPOC minuto 1 (0,014 + 0,03 versus 0,17 + 0,38 cmH2O) e minuto 15 (0,042 + 0,13 versus 0,41 + 0,78 cmH2O) (p<0,05). No subgrupo não-traqueo, nos métodos de PSV15 (0,26 + 0,5 cm H2O) e EPAP15 (0,02 + 0,07 cm H2O), assim como PSV 30 (0,21 + 0,4 cm H2O) e EPAP 30 (0,02 + 0,1 cm H2O) (p<0,05). Para traqueo vs não-traqueo, no método EPAP minuto 1 (PEEPi traqueo 0,58 + 0,94 cm H2O; PEEPi não-traqueo 0,08 + 0,28 cmH2O) e minuto 15 (PEEPi traqueo 0,91 + 2,06 cm H2O; PEEPi não-traqueo 0,02 + 0,07 cmH2O) (p<0,05). Em relação ao WOBtotal houve um aumento significativo no método EPAP em relação ao tubo-t na análise geral da amostra (p<0,05). A f mostrou-se maior no método EPAP para o subgrupo não-DPOC e não-traqueo (minutos 1, 15 e 30). A SaO2 foi maior no subgrupo PSV quando comparada com tubo-t na análise geral da amostra, (p<0,05) Conclusões: A EPAP não demonstrou redução na PEEPi na análise geral da amostra, subgrupo DPOC, não-DPOC e traqueostomizados. Houve redução na PEEPi no grupo não-traqueostomizados. Houve aumento do WOBtotal com o uso da EPAP. Neste estudo a EPAP não demonstrou vantagens em relação aos outros métodos.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Introduction Assist in unison to the patient’s inspiratory neural effort and feedback-controlled limitation of lung distension with neurally adjusted ventilatory assist (NAVA) may reduce the negative effects of mechanical ventilation on right ventricular function. Methods Heart–lung interaction was evaluated in 10 intubated patients with impaired cardiac function using esophageal balloons, pulmonary artery catheters and echocardiography. Adequate NAVA level identified by a titration procedure to breathing pattern (NAVAal), 50% NAVAal, and 200% NAVAal and adequate pressure support (PSVal, defined clinically), 50% PSVal, and 150% PSVal were implemented at constant positive end-expiratory pressure for 20 minutes each. Results NAVAal was 3.1 ± 1.1cmH2O/μV and PSVal was 17 ± 2 cmH20. For all NAVA levels negative esophageal pressure deflections were observed during inspiration whereas this pattern was reversed during PSVal and PSVhigh. As compared to expiration, inspiratory right ventricular outflow tract velocity time integral (surrogating stroke volume) was 103 ± 4%, 109 ± 5%, and 100 ± 4% for NAVAlow, NAVAal, and NAVAhigh and 101 ± 3%, 89 ± 6%, and 83 ± 9% for PSVlow, PSVal, and PSVhigh, respectively (p < 0.001 level-mode interaction, ANOVA). Right ventricular systolic isovolumetric pressure increased from 11.0 ± 4.6 mmHg at PSVlow to 14.0 ± 4.6 mmHg at PSVhigh but remained unchanged (11.5 ± 4.7 mmHg (NAVAlow) and 10.8 ± 4.2 mmHg (NAVAhigh), level-mode interaction p = 0.005). Both indicate progressive right ventricular outflow impedance with increasing pressure support ventilation (PSV), but no change with increasing NAVA level. Conclusions Right ventricular performance is less impaired during NAVA compared to PSV as used in this study. Proposed mechanisms are preservation of cyclic intrathoracic pressure changes characteristic of spontaneous breathing and limitation of right-ventricular outflow impedance during inspiration, regardless of the NAVA level.
Resumo:
INTRODUCTION Inhaled drugs can only be effective if they reach the middle and small airways. This study introduces a system that combines a trans-nasal application of aerosols with noninvasive pressure support ventilation. METHODS In a pilot study, 7 COPD patients with GOLD stages II and III inhaled a radiolabeled marker dissolved in water via a trans-nasal route. The mean aerosol particle size was 5.5 µm. Each patient took part in two inhalation sessions that included two application methods and were at least 70 hours apart. During the first session ("passive method"), the patient inhaled the aerosol through an open tube system. The second session ("active method") included pressure support ventilation during the inhalation process. A gamma camera and planar scintigraphy was used to determine the distribution of aerosol particles in the patient's body and lung. RESULTS The pressure supported inhalation ("active method") results in an increased aerosol lung deposition compared to the passive method. Above all, we could demonstrate deposition in the lung periphery with relatively large aerosol particles (5.5 µm). DISCUSSION The results prove that the combination of trans-nasal inhalation with noninvasive pressure support ventilation leads to significantly increased particle deposition in the lung.
Resumo:
Introducción La ventilación mecánica es fundamental en el manejo de la falla respiratoria aguda, actualmente no existe consenso sobre el momento exacto de extubación. Este estudio describe el comportamiento de la escala OMAHA+ en nuestra institución. Objetivo Principal Describir los desenlaces clínicos relacionados con la escala OMAHA+ durante la extubación de los pacientes de las unidades de cuidado intensivo del hospital universitario. Métodos Estudio descriptivo, retrospectivo, basado en el registro de la escala OMAHA+ de 68 pacientes durante el proceso de extubación en las Unidades de cuidado intensivo adulto de la Fundación Santa Fe de Bogotá durante Agosto de 2014 a Mayo de 2015. Resultados Se encontraron valores gasométricos cercanos a la normalidad, con una PaO2/FiO2 media de 261 (DS 60,6), SaO2 media de 96% (DS 2%), media de lactato sérico de 1.5 mmol/L (DS 1,2 mmol/L), con signos vitales normales. La causa más común de ingreso a UCI fue Neumonía, seguida por cirugía cardiaca y abdominal. Las medias de parámetros ventilatorios al momento de extubación fueron; PEEP de 6 (DS 0,8), volumen corriente de 8ml/Kg (DS 1,4 ml/Kg), índice de Tobín de 34 (DS 11,9), test de fuga positivo 94%, y sólo una extubación fallida. Conclusiones La escala OMAHA+ puede ser una herramienta útil, aplicable y fácilmente reproducible en los pacientes con soporte ventilatorio mecánico invasivo previo al proceso de extubación, con baja proporción de fallo. Estos resultados deben ser evaluados en estudios prospectivos.
Resumo:
Background. The value of respiratory variables as weaning predictors in the intensive care unit (ICU) is controversial. We evaluated the ability of tidal volume (Vtexp), respiratory rate ( f ), minute volume (MVexp), rapid shallow breathing index ( f/Vt), inspired–expired oxygen concentration difference [(I–E)O2], and end-tidal carbon dioxide concentration (PE′CO2) at the end of a weaning trial to predict early weaning outcomes. Methods. Seventy-three patients who required .24 h of mechanical ventilation were studied. A controlled pressure support weaning trial was undertaken until 5 cm H2O continuous positive airway pressure or predefined criteria were reached. The ability of data from the last 5 min of the trial to predict whether a predefined endpoint indicating discontinuation of ventilator support within the next 24 h was evaluated. Results. Pre-test probability for achieving the outcome was 44% in the cohort (n¼32). Non-achievers were older, had higher APACHE II and organ failure scores before the trial, and higher baseline arterial H+ concentrations. The Vt, MV, f, and f/Vt had no predictive power using a range of cut-off values or from receiver operating characteristic (ROC) analysis. The [I–E]O2 and PE′CO2 had weak discriminatory power [areaunder the ROC curve: [I–E]O2 0.64 (P¼0.03); PE′CO2 0.63 (P¼0.05)]. Using best cut-off values for [I–E]O2 of 5.6% and PE′CO2 of 5.1 kPa, positive and negative likelihood ratios were 2 and 0.5, respectively, which only changed the pre- to post-test probability by about 20%. Conclusions. In unselected ICU patients, respiratory variables predict early weaning from mechanical ventilation poorly.
Resumo:
Background: Patients with idiopathic pulmonary fibrosis (IPF) present an important ventilatory (imitation reducing their exercise capacity. Non-invasive ventilatory support has been shown to improve exercise capacity in patients with obstructive diseases; however, its effect on IPF patients remains unknown. Objective: The present study assessed the effect of ventilatory support using proportional, assist ventilation (PAV) on exercise capacity in patients with IPF. Methods: Ten patients (61.2 +/- 9.2 year-old) were submitted to a cardiopulmonary exercise testing, plethysmography and three submaximal. exercise tests (60% of maximum load): without ventilatory support, with continuous positive airway pressure (CPAP) and PAV. Submaximal tests were performed randomly and exercise capacity, cardiovascular and ventilatory response as well as breathlessness subjective perception were evaluated. Lactate plasmatic levels were obtained before and after submaximal. exercise. Results: Our data show that patients presented a limited exercise capacity (9.7 +/- 3.8 mL O(2)/kg/min). Submaximal. test was increased in patients with PAV compared with CPAP and without ventilatory support (respectively, 11.1 +/- 8.8 min, 5.6 +/- 4.7 and 4.5 +/- 3.8 min; p < 0.05). An improved arterial oxygenation and lower subjective perception to effort was also observed in patients with IPF when exercise was performed with PAV (p < 0.05). IPF patients performing submaximal exercise with PAV also presented a lower heart rate during exercise, although systolic and diastolic pressures were not different among submaximal tests. Our results suggest that PAV can increase exercise tolerance and decrease dyspnoea and cardiac effort in patients with idiopathic pulmonary fibrosis. (C) 2009 Elsevier Ltd. All rights reserved.
Resumo:
Background: Noninvasive positive-pressure ventilation (NPPV) modes are currently available on bilevel and ICU ventilators. However, little data comparing the performance of the NPPV modes on these ventilators are available. Methods: In an experimental bench study, the ability of nine ICU ventilators to function in the presence of leaks was compared with a bilevel ventilator using the IngMar ASL5000 lung simulator (IngMar Medical; Pittsburgh, PA) set at a compliance of 60 mL/cm H(2)O, an inspiratory resistance of 10 cm H(2)O/L/s, an expiratory resistance of 20 cm H(2)O/L/s, and a respiratory rate of 15 breaths/min. All of the ventilators were set at 12 cm H(2)O pressure support and 5 cm H(2)O positive end-expiratory pressure. The data were collected at baseline and at three customized leaks. Main results: At baseline, all of the ventilators were able to deliver adequate tidal volumes, to maintain airway pressure, and to synchronize with the simulator, without missed efforts or auto-triggering. As the leak was increased, all of the ventilators (except the Vision [Respironics; Murrysville, PA] and Servo I [Maquet; Solna, Sweden]) needed adjustment of sensitivity or cycling criteria to maintain adequate ventilation, and some transitioned to backup ventilation. Significant differences in triggering and cycling were observed between the Servo I and the Vision ventilators. Conclusions: The Vision and Servo I were the only ventilators that required no adjustments as they adapted to increasing leaks. There were differences in performance between these two ventilators, although the clinical significance of these differences is unclear. Clinicians should be aware that in the presence of leaks, most ICU ventilators require adjustments to maintain an adequate tidal volume. (CHEST 2009; 136:448-456)
Resumo:
Background and objective: Dynamic indices represented by systolic pressure variation and pulse pressure variation have been demonstrated to be more accurate than filling pressures in predicting fluid responsiveness. However, the literature is scarce concerning the impact of different ventilatory modes on these indices. We hypothesized that systolic pressure variation or pulse pressure variation could be affected differently by volume-controlled ventilation and pressure-controlled ventilation in an experimental model, during normovolaemia and hypovolaemia. Method: Thirty-two anaesthetized rabbits were randomly allocated into four groups according to ventilatory modality and volaemic status where G1-ConPCV was the pressure-controlled ventilation control group, G2-HemPCV was associated with haemorrhage, G3-ConVCV was the volume-controlled ventilation control group and G4-HemVCV was associated with haemorrhage. In the haemorrhage groups, blood was removed in two stages: 15% of the estimated blood volume withdrawal at M1, and, 30 min later, an additional 15% at M2. Data were submitted to analysis of variance for repeated measures; a value of P < 0.05 was considered to be statistically significant. Results: At MO (baseline), no significant differences were observed among groups. At M1, dynamic parameters differed significantly among the control and hypovolaemic groups (P < 0.05) but not between ventilation modes. However, when 30% of the estimated blood volume was removed (M2), dynamic parameters became significantly higher in animals under volume-controlled ventilation when compared with those under pressure-controlled ventilation. Conclusions: Under normovolaemia and moderate haemorrhage, dynamic parameters were not influenced by either ventilatory modalities. However, in the second stage of haemorrhage (30%), animals in volume-controlled ventilation presented higher values of systolic pressure variation and pulse pressure variation when compared with those submitted to pressure-controlled ventilation.