922 resultados para Power Converter Control


Relevância:

100.00% 100.00%

Publicador:

Resumo:

This paper presents a step-up micro-power converter for solar energy harvesting applications. The circuit uses a SC voltage tripler architecture, controlled by an MPPT circuit based on the Hill Climbing algorithm. This circuit was designed in a 0.13 mu m CMOS technology in order to work with an a-Si PV cell. The circuit has a local power supply voltage, created using a scaled down SC voltage tripler, controlled by the same MPPT circuit, to make the circuit robust to load and illumination variations. The SC circuits use a combination of PMOS and NMOS transistors to reduce the occupied area. A charge re-use scheme is used to compensate the large parasitic capacitors associated to the MOS transistors. The simulation results show that the circuit can deliver a power of 1266 mu W to the load using 1712 mu W of power from the PV cell, corresponding to an efficiency as high as 73.91%. The simulations also show that the circuit is capable of starting up with only 19% of the maximum illumination level.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This paper describes an architecture conceived to integrate Power Sys-tems tools in a Power System Control Centre, based on an Ambient Intelligent (AmI) paradigm. This architecture is an instantiation of the generic architecture proposed in [1] for developing systems that interact with AmI environments. This architecture has been proposed as a consequence of a methodology for the inclu-sion of Artificial Intelligence in AmI environments (ISyRAmI - Intelligent Sys-tems Research for Ambient Intelligence). The architecture presented in the paper will be able to integrate two applications in the control room of a power system transmission network. The first is SPARSE expert system, used to get diagnosis of incidents and to support power restoration. The second application is an Intelligent Tutoring System (ITS) incorporating two training tools. The first tutoring tool is used to train operators to get the diagnosis of incidents. The second one is another tutoring tool used to train operators to perform restoration procedures.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Cyber-Physical Systems and Ambient Intelligence are two of the most important and emerging paradigms of our days. The introduction of renewable sources gave origin to a completely different dimension of the distribution generation problem. On the other hand, Electricity Markets introduced a different dimension in the complexity, the economic dimension. Our goal is to study how to proceed with the Intelligent Training of Operators in Power Systems Control Centres, considering the new reality of Renewable Sources, Distributed Generation, and Electricity Markets, under the emerging paradigms of Cyber-Physical Systems and Ambient Intelligence. We propose Intelligent Tutoring Systems as the approach to deal with the intelligent training of operators in these new circumstances.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The activity of Control Center operators is important to guarantee the effective performance of Power Systems. Operators’ actions are crucial to deal with incidents, especially severe faults, like blackouts. In this paper we present an Intelligent Tutoring approach for training Portuguese Control Centre operators in tasks like incident analysis and diagnosis, and service restoration of Power Systems. Intelligent Tutoring System (ITS) approach is used in the training of the operators, taking into account context awareness and the unobtrusive integration in the working environment.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Control Centre operators are essential to assure a good performance of Power Systems. Operators’ actions are critical in dealing with incidents, especially severe faults, like blackouts. In this paper we present an Intelligent Tutoring approach for training Portuguese Control Centre operators in incident analysis and diagnosis, and service restoration of Power Systems, offering context awareness and an easy integration in the working environment.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

John Hardman Moore outlines his joint research with Oliver Hart, looking at the economics of power and control and the foundations of contractual incompleteness

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Trata el tema de la monarquía medieval inglesa entre 1100 y 1500, desde una perspectiva que ayude a los alumnos a acercarse a la historia de la Edad Media y mostrar su relevancia en el mundo actual. Este contenido se adapta a las pruebas de evaluación que realiza el organismo Oxford Cambridge and RSA Examinations (OCR) para obtener el título de General Certificate Secondary Education (GCSE) en historia. Se completa con un material online de apoyo al profesorado.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This multiple case-based study investigates the relationship between recruiting agents and the UK universities who act as their principals. The current extensive use of agents in UK higher education may be seen as an indicator of the financial impact made by international students. The study analyses the practice of agent management and explores the manner in which power and control interact. The study employed semi-structured interviews and group discussions involving up to 6 respondents from each of the 20 UK case institutions. The qualitative data reveal a considerable variation in the manner in which the universities manage their agency relationships. Through the joint consideration of control measures and use of power, five distinctive approaches have been identified. The study also reveals that over-dependence on agents reduces the power of the principal, and consequently, the principal’s ability to exercise control, particularly in highly competitive global and national markets.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Researches on control for power electronics have looked for original solutions in order to advance renewable resources feasibility, specially the photovoltaic (PV). In this context, for PV renewable energy source the usage of compact, high efficiency, low cost and reliable converters are very attractive. In this context, two improved simplified converters, namely Tri-state Boost and Tri-state Buck-Boost integrated single-phase inverters, are achieved with the presented Tri-state modulation and control schemes, which guarantees the input to output power decoupling control. This feature enhances the field of single-phase PV inverters once the energy storage is mainly inductive. The main features of the proposal are confirmed with some simulations and experimental results. © 2012 IEEE.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This paper proposes a new methodology to control the power flow between a distributed generator (DG) and the electrical power distribution grid. It is used the droop voltage control to manage the active and reactive power. Through this control a sinusoidal voltage reference is generated to be tracked by voltage loop and this loop generates the current reference for the current loop. The proposed control introduces feed-forward states improving the control performance in order to obtain high quality for the current injected to the grid. The controllers were obtained through the linear matrix inequalities (LMI) using the D-stability analysis to allocate the closed-loop controller poles. Therefore, the results show quick transient response with low oscillations. Thus, this paper presents the proposed control technique, the main simulation results and a prototype with 1000VA was developed in the laboratory in order to demonstrate the feasibility of the proposed control. © 2012 IEEE.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Abstract. During the last decade mobile communications increasingly became part of people's daily routine. Such usage raises new challenges regarding devices' battery lifetime management when using most popular wireless access technologies, such as IEEE 802.11. This paper investigates the energy/delay trade-off of using an end-user driven power saving approach, when compared with the standard IEEE 802.11 power saving algorithms. The assessment was conducted in a real testbed using an Android mobile phone and high-precision energy measurement hardware. The results show clear energy benefits of employing user-driven power saving techniques, when compared with other standard approaches.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In this paper the power-frequency control of hydropower plants with long penstocks is addressed. In such configuration the effects of pressure waves cannot be neglected and therefore commonly used criteria for adjustment of PID governors would not be appropriate. A second-order Π model of the turbine-penstock based on a lumped parameter approach is considered. A correction factor is introduced in order to approximate the model frequency response to the continuous case in the frequency interval of interest. Using this model, several criteria are analysed for adjusting the PI governor of a hydropower plant operating in an isolated system. Practical criteria for adjusting the PI governor are given. The results are applied to a real case of a small island where the objective is to achieve a generation 100% renewable (wind and hydro). Frequency control is supposed to be provided exclusively by the hydropower plant. It is verified that the usual criterion for tuning the PI controller of isolated hydro plants gives poor results. However, with the new proposed adjustment, the time response is considerably improved

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This paper presents some power converter architectures and circuit topologies, which can be used to achieve the requirements of the high performance transformer rectifier unit in aircraft applications, mainly as: high power factor with low THD, high efficiency and high power density. The voltage and the power levels demanded for this application are: three-phase line-to-neutral input voltage of 115 or 230V AC rms (360 – 800Hz), output voltage of 28V DC or 270V DC(new grid value) and the output power up to tens of kilowatts.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Este trabajo forma parte del proyecto “Health aware enhanced range wireless power transfer systems”, conocido por el acrónimo de ETHER. Los grupos investigadores que forman parte de ETHER involucran a dos instituciones, Universidad Politécnica de Cataluña (UPC) y Universidad Politécnica de Madrid (UPM). En este caso, el trabajo ha sido llevado a cabo en el marco del Centro de Electrónica Industrial(CEI) de la UPM. Además, este trabajo es el tercero en una sucesión de estudios realizados por el CEI con el objetivo de lograr implementar un sistema de carga inalámbrica en un marcapasos. Los trabajos previos al desarrollado son los realizados por Miguel Gifford y María Gonzalez. Otros trabajos del CEI han servido de guía. El principal objetivo de la aplicación, es evitar las operaciones que se llevan a cabo actualmente para la sustitución de la batería de los marcapasos implantados en pacientes. Este periodo de sustitución es del orden de cuatro años, lo que depende del tipo de marcapasos y las circunstancias en las que se vea envuelto el paciente. Se pretende lograr la carga del dispositivo causando la menor molestia posible al paciente sin afectar a su salud. El sistema de carga inalámrica o WPT1, está basado en inducción magnética resonante, conocida como RIC2. Esta tecnología se fundamenta en el uso de bobinas acopladas como elemento transmisor de energía. A su vez, la impedancia de estas bobinas, es compensada mediante el uso de condensadores, obteniendo circuitos resonantes. Mediante el uso de RIC se logran mejores características técnicas para la transmisión de energía en el rango medio. Esto permite salvar la distancia entre el elemento generador y la batería del marcapasos, incluso ante la existencia de tejido orgánico entre las dos bobinas. Se han considerado dos posibilidades de configuraci´on del sistema. Dos etapas: se dispone de dos bobinas, emisora y receptora. Esta configuración supone trabajar a altas frecuencias para conseguir transferencia de energías efectivas teniendo en cuenta las especificaciones del marcapasos. Tres etapas: se dispone de tres bobinas, emisora, intermedia y receptora. Se mejora el alcance, permitiendo trabajar a menores frecuencias, pero complicando el control y la implementación del sistema. Sin embargo, el foco de los esfuerzos invertidos en este trabajo, es el estudio del sistema de optimización que se introduce en las configuraciones anteriormente descritas. La optimización se centra en conseguir máxima transferencia de potencia, quedando relegado a un segundo plano el rendimiento. Esto se justifica por las características de la aplicación donde la principal limitación es la viabilidad del sistema. Asímismo, la viabilidad viene impuesta por la potencia que consume el marcapasos y la que es capaz de suministrar el sistema. Este sistema de optimización se basa en la regulación en frecuencia y en la adaptación de la impedancia de carga. Este último método es estudiado, y se basa en lograr una impedancia de carga igual al complejo conjugado de la impedancia de salida, logrando máxima transferencia de potencia. El sistema de optimización hace uso de varias estructuras de control de electrónica de potencia. Inversor: Se sitúa en la etapa emisora y permite controlar la frecuencia de trabajo del sistema. Rectificador activo: Se sitúa en la etapa receptora y controla el desfase entre intensidad y tensión. Convertidor CC-CC: Se sitúa en la etapa receptora, tras el rectificador. Controla la amplitud de la tensión.Mediante el uso conjunto del rectificador y el convertidor es posible controlar la impedancia de la carga. Se ha realizado un análisis teórico para determinar el punto de funcionamiento óptimo del sistema, y posteriormente, se han validado estos resultados mediante simulaciones. Se demuestra que la potencia transferida por el sistema WTP se multiplica por cinco respecto de la solución original, es decir, en ausencia del sistema de optimización. Además se logra mayor robustez, ya que el control activo del sistema proporciona mayor adaptabilidad ante condiciones alejadas de las de diseño. El trabajo realizado se ha prolongado durante un periodo de doscientos días efectivos con una dedicación de 360 horas de trabajo. El coste total asignado al desempeño del trabajo es de 16.678,94 euros.