203 resultados para Plaster.
Resumo:
Sandwich panels of laminated gypsum and rock wool have shown large pathology of cracking due to excessive slabs deflection. Currently the most widespread use of this material is as vertical elements of division or partition, with no structural function, what justifies that there are no studies on the mechanism of fracture and mechanical properties related to it. Therefore, and in order to reduce the cracking problem, it is necessary to progress in the simulation and prediction of the behaviour under tensile and shear load of such panels, although in typical applications have no structural responsability.
Resumo:
This work presents the main experimental results obtained from the study of plaster test pieces and boards with addition of various volumetric rubber fractions from mechanical grinding of end-of-life tires (ELTs), in three different particle size gradations. It includes a description of the materials employed, and their proportions. The physical and mechanical properties, as well as the thermal conductivity and acoustic insulation properties are analyzed. Experimental results obtained for specimens with addition of recycled rubber are compared with similar ones, carried out on specimens of plaster of identical features without any addition, evaluating the influence of the particle size and mixture proportions. An improvement in thermal and acoustic performance has been obtained as well as a reduction in density, and as a result, some constructive applications for paving and slabs in rehabilitation works are proposed.
Resumo:
The main objective of this research is to study the feasibility of recycling fibres from construction and demolition waste (C&DW) as an alternative material to chopped glass fibres which are used today as reinforcing elements in the prefabricated plaster. To do this, sets of samples are made with rockwool and different percentages of combinations between water / plaster. These series are repeated by changing the additive E glass fibre length of 25mm to make a comparative analysis with respect to the series infused with rockwool.
Resumo:
The use of mineral wool is becoming more widespread due to increased acoustic and thermal demands of Spanish Technical Building Code. This increase affects both in rehabilitation and new construction projects. Therefore, waste generation of this type of insulating material is having more importance. The main objective of this research is to study the possibility of recycling fiber obtained from mineral wool of the C&DW as an alternative material to chopped glass fibers that are currently used as reinforcing elements in the prefabricated plaster. To achieve this objective, series are made of plaster E-35 additived with rock wool residue and glass wool residue at different rates of addition. These series are repeated by changing the additive by E fiberglass (length of 25mm) to make a comparative analysis with respect to the series additived with mineral wool waste. All the series are subjected to the test to determine Shore C surface hardness and mechanical testing to determine the compressive and flexural strength. From the results it can be concluded that: with rock wool residue, increases Shore C hardness up to 15% with respect to the glass fiber and 9% with respect to the glass wool, with a percentage of addition 2%. With rock wool residue, weight is decreased by 5% with respect to the glass fiber and 4% with respect to the glass wool waste, with an addition percentage of 4%. For an addition rate of 4%, results in the flexural strength test with fiberglass are 85% higher than those obtained with glass wool residue. However, for a percentage of 1% addition, the results obtained with glass wool residue are 35% higher than those obtained with fiberglass. For an addition rate of 3% results in the compressive strength test with fiberglass are 54% lower than those obtained with rock wool waste and 70% lower than those obtained with glass wool waste. Comparing the two mineral wools, it can be concluded that up to 3% of the addition, the glass wool series results obtained are 10% higher than those additived with rock wool. However, higher percentages of addition show that the results obtained with rock wool are 35% higher than those obtained with glass wool. The general conclusion is that the series additived with mineral wool from C&DW show better results in tests than the ones used nowadays as plaster reinforcement.
Resumo:
Over the last decade the intense activity of the building sector has generated large quantities of construction and demolition waste (CDW). In particular, in Europe around 890 million tons of CDW is generated every year; however, only 50% of them are recycled. In Spain, over the last years 40 millions of tons of construction and demolition waste have been generated. On the other hand, since the implementation of the Technical Building Code regulation the use of mineral wools as building insulation materials has become a widespread solution in both rehabilitation and new construction works, and because of that, this kind of insulation waste is increasing. This research analyzes the potential of a new composite (gypsum and fiber waste) including several mineral wools waste into a plaster matrix. For this purpose, an experimental plan, characterizing the physical and mechanical behaviour as well as the Shore C hardness of the new composite, was elaborated fulfilling UNE Standards.
Resumo:
Buildings Indoor Air Quality requires a control in the Relative Humidity parameter. In passive architecture in humid climates relative humidity is even more important for human comfort and difficult to control. Therefore, nowadays, there is a research on dehumidifying systems. The present article shows an innovative dehumidifying panel composed of a plaster and Calcium Chloride salt. Laboratory tests are carried out to establish its viability as an indoor air moister regulator integrated in common plaster building interior coatings. There are two types of tests that have been carried out in two consecutive empirical phases: in the first phase, the tests of characterization of the Calcium Chloride as a desiccant are carried out; in a second phase, the dehumidifying panel as a whole is tested. Finally, both types of empirical tests show the efficiency and viability as an air moisture passive control system.
Resumo:
no.6(1940)
Resumo:
"The historical portions of the work ... have been written by Mr. John Southward."--p. vii.
Resumo:
Mode of access: Internet.
Resumo:
Mode of access: Internet.
Resumo:
Mode of access: Internet.
Resumo:
Mode of access: Internet.
Resumo: