911 resultados para Pediatric hip radiography
Resumo:
The effect of copper (Cu) filtration on image quality and dose in different digital X-ray systems was investigated. Two computed radiography systems and one digital radiography detector were used. Three different polymethylmethacrylate blocks simulated the pediatric body. The effect of Cu filters of 0.1, 0.2, and 0.3 mm thickness on the entrance surface dose (ESD) and the corresponding effective doses (EDs) were measured at tube voltages of 60, 66, and 73 kV. Image quality was evaluated in a contrast-detail phantom with an automated analyzer software. Cu filters of 0.1, 0.2, and 0.3 mm thickness decreased the ESD by 25-32%, 32-39%, and 40-44%, respectively, the ranges depending on the respective tube voltages. There was no consistent decline in image quality due to increasing Cu filtration. The estimated ED of anterior-posterior (AP) chest projections was reduced by up to 23%. No relevant reduction in the ED was noted in AP radiographs of the abdomen and pelvis or in posterior-anterior radiographs of the chest. Cu filtration reduces the ESD, but generally does not reduce the effective dose. Cu filters can help protect radiosensitive superficial organs, such as the mammary glands in AP chest projections.
Resumo:
BACKGROUND: The AO comprehensive pediatric longbone fracture classification system describes the localization and morphology of fractures, and considers severity in 3 categories: (1) simple, (2) wedge, and (3) complex. We evaluated the reliability and accuracy of surgeons in using this rating system. MATERIAL AND METHODS: In a first validation phase, 5 experienced pediatric (orthopedic) surgeons reviewed radiographs of 267 prospectively collected pediatric fractures (agreement study A). In a second study (B), 70 surgeons of various levels of experience in 15 clinics classified 275 fractures via internet. Simple fractures comprised about 90%, 99% and 100% of diaphyseal (D), metaphyseal (M), and epiphyseal (E) fractures, respectively. RESULTS: Kappa coefficients for severity coding in D fractures were 0.82 and 0.51 in studies A and B, respectively. The median accuracy of surgeons in classifying simple fractures was above 97% in both studies but was lower, 85% (46-100), for wedge or complex D fractures. INTERPRETATION: While reliability and accuracy estimates were satisfactory as a whole, the ratings of some individual surgeons were inadequate. Our findings suggest that the classification of fracture severity in children should be done in only two categories that distinguish between simple and wedge/complex fractures.
Resumo:
Reconstruction of important parameters such as femoral offset and torsion is inaccurate, when templating is based on plain x-rays. We evaluate intraoperative reproducibility of pre-operative CT-based 3D-templating in a consecutive series of 50 patients undergoing primary cementless THA through an anterior approach. Pre-operative planning was compared to a postoperative CT scan by image fusion. The implant size was correctly predicted in 100% of the stems, 94% of the cups and 88% of the heads (length). The difference between the planned and the postoperative leg length was 0.3 + 2.3 mm. Values for overall offset, femoral anteversion, cup inclination and anteversion were 1.4 mm ± 3.1, 0.6° ± 3.3°, -0.4° ± 5° and 6.9° ± 11.4°, respectively. This planning allows accurate implant size prediction. Stem position and cup inclination are accurately reproducible.
Resumo:
The aim was to propose a strategy for finding reasonable compromises between image noise and dose as a function of patient weight. Weighted CT dose index (CTDI(w)) was measured on a multidetector-row CT unit using CTDI test objects of 16, 24 and 32 cm in diameter at 80, 100, 120 and 140 kV. These test objects were then scanned in helical mode using a wide range of tube currents and voltages with a reconstructed slice thickness of 5 mm. For each set of acquisition parameter image noise was measured and the Rose model observer was used to test two strategies for proposing a reasonable compromise between dose and low-contrast detection performance: (1) the use of a unique noise level for all test object diameters, and (2) the use of a unique dose efficacy level defined as the noise reduction per unit dose. Published data were used to define four weight classes and an acquisition protocol was proposed for each class. The protocols have been applied in clinical routine for more than one year. CTDI(vol) values of 6.7, 9.4, 15.9 and 24.5 mGy were proposed for the following weight classes: 2.5-5, 5-15, 15-30 and 30-50 kg with image noise levels in the range of 10-15 HU. The proposed method allows patient dose and image noise to be controlled in such a way that dose reduction does not impair the detection of low-contrast lesions. The proposed values correspond to high- quality images and can be reduced if only high-contrast organs are assessed.
Resumo:
This study is a long-term analysis of a group of patients with infected arthroplasties of the hip or the knee. We identified 28 patients with an infected arthroplasty (22 hips, 6 knees) documented by bacterial culture or on direct examination. At the time of diagnosis and on follow-up (a mean of 46 months after treatment) we evaluated the clinical picture, the radiological appearances of the articulation and the biological parameters. 19/28 patients showed a typical clinical picture, whereas in 9 others the picture was more doubtful. The treatments were 14 two-stage replacements of the arthroplasties, 7 simple resections, 5 conservative treatments and 2 one-stage replacements. On follow-up, 25 patients were considered as cured of their infection and 3 as failures. From a functional viewpoint, 9 patients showed no limitation, whereas 19 were limited in the daily activity. Half of the patients had no pain. Radiology showed that 20/26 evaluated patients had no signs of recurrence. Paraclinical examinations are important in the diagnosis of persistent low grade infections, particularly the demonstration of bacteria by pre-surgical sampling (fine needle aspiration, culture from draining sinuses). In spite of the cure of infection, the functional and painful sequellae are often considerable. As a result of our experience, we recommend a two-stage surgical procedure. Only when the general condition of the patient is poor, or when the infection is not under control, would we envisage an alternative procedure (arthrodesis, girdelstone, conservative).
Resumo:
Painful femoro-acetabular impingement symptoms localized in the groin in flexion, adduction and internal rotation can be explained either by a primary disease of the labrum often post-traumatic, and more frequently as part of femoro-acetabular primary or secondary dysmorphia. The kinematic of the normal hip joint depends of peri-acetabular structures, geometry of joints and possible pathologies that could contribute to modify either the geometry or the proprioceptive function. By combining and analyzing these parameters it is possible to describe a joint concept of centricity, an essential parameter for optimal functions of the joint. The concept of overload is explained as the inability of the hip to ensure its centricity during activities that could lead to the occurrence of any degenerative disorders.
Resumo:
OBJECTIVES: To describe the spectrum of pathologies responsible for neck ailments in a primary care pediatric emergency setting and evaluate their outcome. METHODS: All children aged 16 years or younger, who presented to the emergency department of the Children's Hospital of Lausanne during a 1-year period, were retrospectively identified and charts were reviewed. Causes of neck complaints were classified as traumatic (group 1), infectious (group 2), postural (group 3), or miscellaneous (group 4) according to the final diagnosis. History and physical examination findings, radiological and laboratory results, as well as patient outcomes were recorded. RESULTS: During the study period, 28,722 children were observed in the emergency department, and 170 were identified as having neck complaints. The number of patients with neck ailments in group 1 was 105 (62%). Group 2 contained 33 patients (19%), of which 28 (16.5%) had a viral infection and 5 (2.9%) had a bacterial infection. Group 3 contained 30 children (17.6%) and group 4 contained 2 children (1.2%). Cervical spine radiography was performed on an emergency basis in 60 children (57 in group 1, 2 in group 2, and 1 in group 3). Significant abnormalities were observed in 6 children. Cervical computed tomography (CT) was performed in 9 children, from which 5 were in group 1, 3 were in group 2, and 1 was in group 4. The CT scan revealed pathologic findings in 6 children. Follow-up data were available in 135 patients (79.4%), of which 129 (95.6%) experienced complete recovery in less than 2 weeks. Admission to the hospital was necessary in 4 children (1 in group 1 and 3 in group 2), including 2 for emergency surgical drainage of retropharyngeal abscesses. One child with posttraumatic torticollis was treated conservatively as an outpatient and recovered in 7 weeks. One child was had his/her condition eventually diagnosed with osteoid osteoma and treated with oral nonsteroidal anti-inflammatory drug. CONCLUSIONS: Most cases of neck ailments in children presenting to the emergency department were due to trauma or infection, which were effectively managed as outpatients. When signs and symptoms suggested an emergent cause, CT provided a definitive diagnosis. The evaluation of a child presenting with acute neck complaints should be based on history and physical examination. Plain radiographs and CT scan are contributive in selected cases.
Resumo:
Abstract Objective: To estimate the entrance surface air kerma (Ka,e) and air kerma in the region of radiosensitive organs in radiographs of pediatric paranasal sinuses. Materials and Methods: Patient data and irradiation parameters were collected in examinations of the paranasal sinuses in children from 0 to 15 years of age at two children's hospitals in the city of Recife, PE, Brazil. We estimated the Ka,e using the X-ray tube outputs and selected parameters. To estimate the air kerma values in the regions of the eyes and thyroid, we used thermoluminescent dosimeters. Results: The Ka,e values ranged from 0.065 to 1.446 mGy in cavum radiographs, from 0.104 to 7.298 mGy in Caldwell views, and from 0.113 to 7.824 mGy in Waters views. Air kerma values in the region of the eyes ranged from 0.001 to 0.968 mGy in cavum radiographs and from 0.011 to 0.422 mGy in Caldwell and Waters views . In the thyroid region, air kerma values ranged from 0.005 to 0.932 mGy in cavum radiographs and from 0.002 to 0.972 mGy in Caldwell and Waters views. Conclusion: The radiation levels used at the institutions under study were higher than those recommended in international protocols. We recommend that interventions be initiated in order to reduce patient exposure to radiation and therefore the risks associated with radiological examination of the paranasal sinuses.
Resumo:
La scoliose idiopathique de l’adolescence (SIA) est une déformation tridimensionnelle de la colonne vertébrale et de la cage thoracique dont la cause est inconnue. Il semble que la ceinture pelvienne soit impliquée dans la pathogénie de la SIA, car des différences géométriques des os coxaux ont été observées. Notamment, une rotation du bassin ou une inclinaison latérale dans le sens de la courbe scoliotique ont été mises en évidence en plus des distorsions osseuses. Il est difficile de dissocier la rotation du bassin de son asymétrie, car la majorité des études porte sur des données radiologiques bidimensionnelles. Une analyse tridimensionnelle de la morphologie du bassin de patientes ayant une SIA, mais n’ayant pas reçu de traitement par corset ou chirurgie permettrait d’identifier le rôle du bassin dans la progression de la scoliose. Dix-sept jeunes filles atteintes de la SIA ont participé à cette étude pour lesquelles des radiographies bi-planaires en station debout étaient disponibles au moment du diagnostic par un chirurgien orthopédiste pédiatrique et à l’instant de la prescription d'un corset. Des radiographies postéro-antérieures et latérales avaient été prises au moyen du système EOS®. Douze repères anatomiques du bassin ont été identifiés sur les paires de radiographies, alors que quatre repères ont été identifiés sur la radiographie postéro-antérieure uniquement. Ces quatre derniers n’étaient pas identifiables sur la radiographie latérale à cause de la superposition des repères droits et gauches. La reconstruction tridimensionnelle du bassin a été réalisée à partir de deux clichés radiographiques des 12 premiers repères osseux. Au total, neuf paramètres tridimensionnels ont été calculés afin de quantifier l’asymétrie et la distorsion du bassin entre les deux temps donnés. Des paramètres bidimensionnels ont également été mesurés sur les quatre derniers repères osseux afin de documenter des déformations du bassin pertinentes à la pratique clinique, telle que la rotation axiale de celui-ci. Dans le but d'évaluer une possible asymétrie entre les os coxaux du bassin, les paramètres tridimensionnels du bassin gauche ont été comparés à ceux du côté droit à chaque temps, au moyen d'un test-t pour échantillon apparié. La morphologie pelvienne a été également évaluée par l'analyse multivariée (MANOVA) à mesures répétées à deux conditions (côté*temps). En conséquence, nous avons constaté une croissance osseuse statistiquement significative du bassin dans l’intervalle de temps entre le diagnostic de la scoliose et le port du corset (p=0,033). Une asymétrie significative entre les côtés gauche et droit du bassin (p=0,013) a également été constatée. En ce qui concerne les paramètres bidimensionnels, nous avons constaté une augmentation de la version pelvienne (p=0,024) au cours de la croissance des jeunes filles. Finalement, le bassin n'a pas présenté de distorsion, puisqu'une valeur de p de 0,763 a été observée. En conclusion, la croissance des jeunes filles atteintes de la scoliose idiopathique de l'adolescence est accompagnée d'une asymétrie morphologique entre les deux os coxaux du bassin. Cette asymétrie constatée au moment du diagnostic de la scoliose des filles a évolué jusqu'à l’instant où le port du corset a été prescrit. Quant aux paramètres bidimensionnels, nous pouvons conclure que la rotation du bassin vers l'arrière a augmenté au cours de la croissance des jeunes filles, produisant ainsi une rétroversion pelvienne dans le plan sagittal. La distorsion tridimensionnelle du bassin n'a toutefois pas été observée au cours de la croissance des jeunes filles.
Resumo:
The aim of this work is to prospectively study the value of thoracic ultrasound (US) before pleural drainage in children with parapneumonic effusion (PPE). All children hospitalized for PPE, identified by thoracic radiography, underwent US to assess pleural loculation, echogenicity, and pleural fluid quantity. From August 2001 to July 2003, 52 children were examined. US was performed on 48 of these children, of whom 35 received chest tube drainage and 13 only received clinical treatment. US identified 38 patients with free flowing and 10 with loculated pleural fluid. About 25 of the free flowing (65.8%) and 10 (100%) of the loculated patients received chest tube drainage. Echogenicity was anechoic in 13, echoic without septations in 17 and echoic with septations in 18. Chest tube drainage was required in 6 anechoic (46.15%), 14 echoic without septations (82.35%), and 15 echoic with septations (83.33%). Quantity of fluid estimated by US varied from 20 to 860 ml. Effusion volume was higher in patients that were echoic with septations and loculated effusions. Pleural glucose and pH were lower, and LDH was higher in loculated PPE patients. In conclusion, US is an auxiliary exam for determining whether thoracic drainage is needed in parapneumonic effusion; loculated or echoic effusion should be drained, and free anechoic fluid needs further investigation.
Resumo:
Purpose: the purpose of this in vivo study was to compare the accuracy of primary incisor length determined by direct digital radiography (straight-line measurement and grid superimposition) and measurement of the actual tooth length. Methods. Twenty-two primary maxillary incisors that required extractions were selected from 3- to 5-year-old children. The teeth were radiographed with an intraoral sensor using the long cone technique and a sensor holder (30-cm focus-to-sensor distance). The exposure time was 03 seconds. Tooth length was estimated by using straight-line and grid measurements provided by the distance measurement feature of the Computed Dental Radiography digital dental imaging system. The actual tooth length was obtained by measuring the extracted tooth with G digital caliper. Data were analyzed statistically by Pearson's correlation coefficient and a paired t test. Results: There were statistically significant differences (P=.007) between the 2 measurement techniques and between the actual tooth lengths and grid measurements. There was no statistically significant difference (P=38) between straight-line measurements and actual tooth lengths, showing that the straight-line measurements were more accurate. Underestimation of the actual tooth length, however, occurred in 45% of the straight-line measurements and in 73% of the grid measurements. Conclusion: It is possible to determine primary tooth length in digital radiographs using onscreen measurements with 0 reasonable degree of accuracy.
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
OBJECTIVE: To compare the existence of radiographic abnormalities in two groups of patients, those with and without hip pain. METHODS: A total 222 patients were evaluated between March 2007 and April 2009; 122 complained of groin pain, and 100 had no symptoms. The individuals in both groups underwent radiographic examinations of the hip using the following views: anteroposterior, Lequesne false profile, Dunn, Dunn 45º, and Ducroquet. RESULTS: A total of 1110 radiographs were evaluated. Female patients were prevalent in both groups (52% symptomatic, 58% asymptomatic). There were statistically significant differences between the groups in age (p<0.0001), weight (p = 0.002) and BMI (p = 0.006). The positive findings in the group with groin pain consisted of the presence of a bump on the femoral head in the anteroposterior view (p<0.0001) or in the Dunn 45º view (p = 0.008). The difference in the a angle in the anteroposterior, Dunn, Dunn 45º, and Ducroquet views for all of the cases studied was p,0.0001. The joint space measurement differed significantly between groups in the Lequesne view (p = 0.007). The Lequesne anteversion angle (ρ) and the femoral offset measurement also differed significantly (p = 0.005 and p = 0.0001, respectively). CONCLUSIONS: We conclude that the best views for diagnosing a femoroacetabular impingement are the anteroposterior pelvic orthostatic, the Dunn 45º, and the Ducroquet views. The following findings correlated with hip pain: a decrease in the femoral offset, an increase in the α angle, an increase in the Lequesne ρ angle, a decrease in the CE angle of Wiberg, a thinner articular space and the presence of a bump on the femoral head-neck transition.
Resumo:
The effect of copper (Cu) filtration on image quality and dose in different digital X-ray systems was investigated. Two computed radiography systems and one digital radiography detector were used. Three different polymethylmethacrylate blocks simulated the pediatric body. The effect of Cu filters of 0.1, 0.2, and 0.3 mm thickness on the entrance surface dose (ESD) and the corresponding effective doses (EDs) were measured at tube voltages of 60, 66, and 73 kV. Image quality was evaluated in a contrast-detail phantom with an automated analyzer software. Cu filters of 0.1, 0.2, and 0.3 mm thickness decreased the ESD by 25-32%, 32-39%, and 40-44%, respectively, the ranges depending on the respective tube voltages. There was no consistent decline in image quality due to increasing Cu filtration. The estimated ED of anterior-posterior (AP) chest projections was reduced by up to 23%. No relevant reduction in the ED was noted in AP radiographs of the abdomen and pelvis or in posterior-anterior radiographs of the chest. Cu filtration reduces the ESD, but generally does not reduce the effective dose. Cu filters can help protect radiosensitive superficial organs, such as the mammary glands in AP chest projections.
Resumo:
OBJECTIVE: The purpose of this study was to review the diagnosis on MRI and radiography of 24 renal transplant recipients with hip pain suspicious for avascular necrosis and to investigate whether there is an association between kidney transplant patients with end-stage renal disease and symptomatic gluteus minimus and medius tendon abnormality. CONCLUSION: Symptomatic gluteus minimus and medius tendon lesions and abnormalities can occur in renal allograft recipients. The MRI findings of this entity allow an alternative diagnosis in this patient population.