156 resultados para Parafusos protéticos


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Pós-graduação em Reabilitação Oral - FOAR

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

O presente estudo avaliou a adaptação da interface implante/componente protético, utilizando pilares Micro-Units com seus respectivos copings acrílicos (Conexão Sistemas de Prótese – São Paulo – SP – Brasil) e UCLAs (Conexão Sistemas de Prótese – São Paulo – SP – Brasil), por meio de três diferentes técnicas: cimentação (grupo 1), fundição em monobloco (grupo 2) e fundição e brasagem (grupo 3). Foram confeccionados 20 corpos - de- prova, cada corpo apresentava 3 componentes protéticos e duas barras que os unia. Foram utilizados 30 componentes protéticos Micro-Units, 30 copings acrílicos dos Micro-Units (Conexão Sistemas de Prótese – São Paulo – SP – Brasil) e 30 UCLAs (Conexão Sistemas de Prótese – São Paulo – SP – Brasil). Também foram usadas 40 barras cilíndricas de 2mm de diâmetro, obtidas a partir de uma matriz. Cada grupo tinha 10 corpos-de-prova. Os corpos-deprova foram divididos inicialmente em dois grupos. No grupo 1 foram utilizados componentes protéticos Micro-Units e seus respectivos copings acrílicos, os quais foram fundidos em Cr-Co, parafusados e cimentados sobre os Micro-Units. No grupo 2 os componentes protéticos calcináveis (UCLA), foram fundidos em monobloco utilizando-se Cr-Co. Posteriormente foi realizada a separação das peças em monobloco do grupo 2, o qual passou a ser chamado de grupo 3, sendo então submetido à brasagem. Todos os grupos foram mensurados em um estereomicroscópio (SZX12, Olympus, Japan) com aumento de 60X em relação à adaptação, antes e após os procedimentos para a obtenção das estruturas, através de cada técnica. Os resultados mostraram que o grupo 1 apresentou uma adaptação estatisticamente superior, inicial (0,000μm) e final (3,588μm), em relação aos grupos 2 (9,252μm e 325,259μm) e 3 (0,874μm e 121,592μm). O grupo 3 apresentou uma melhora significativa em relação ao grupo 2. A técnica com melhor adaptação foi a cimentação.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Whereas the assembly torque calculation has great importance on efficiency and life of bolts, the objective of this study was to analyze the combined stresses during assembly, the friction coefficient, compare the rupture torque results with the indicated torques by standards and to present a new torque method without the stress combination (shear stress and normal stresses). For this study were carried eighteen tests with different diameters and materials, this bolts were undergoing five ranges torque until the breaking torque. With the experimental rupture torque values for each test and with the bolt quality certificate was possible to calculate the friction coefficient so compared with the theory. Another comparison was the experimental rupture torque with assembly torque indicated by NBR-8800 and ASME-PCC. The main conclusion are related to combined stress, because for this factor can fail at the assembly time, so for in some cases must use the tensioning method, because in this method won't be present torsional stresses

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The objective of this in vitro study was quantify the micro strain development around the internal hexagon implants, varying the type of prosthetic coping. For This reason, three implants of internal hexagon were inserted into one polyurethane block in line placement. Microunit abutments were screwed onto the implants. Tangentially the implants were bonded the strain gauges, two to the center implant. Ten structures, each one containing three copings were cast in Co-Cr alloy, that were divided into groups in the first group, plastic copings were used, and in the second group machined copings were used. The superstructure’s occlusal screws were tightened onto Microunit abutments with 10 Ncm torque, the magnitude of micro strain was recorded. The mean values of each strain gauge of each plastic copings were 363,37 ± 237,66 and the machined copings were 338,12 ± 223,01. The data were analyzed statistically by t- Student test. No statistically significant difference was found between the prosthetic copings (p= 0,867). It was concluded that to internal hexagon implants in line placement, the type of copings presented similar magnitude of micro strain after prosthetic occlusal screw was tightened

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Zirconia abutments are used to obtain satisfactory aesthetic results in implant fixed anterior prostheses when metal abutments promote a grayish mucosal discoloration of the peri-implant soft tissues. However, there is a lack of studies to confirm the clinical performance of the peri-implant soft tissues surrouding zirconia abutments. This study described a case report of a patient treated with implant fixed all-ceramic crown made out on zirconia abutment after 3 years of followup. A 47-year-old female patient was admitted to the dental clinic (Aracatuba Dental School) complaining about the fracture of her implant fixed single crown in the region of the left lateral incisor. The patient chose the replacement of the fractured prosthesis for an allceramic crown. After 3 years of follow-up it was observed that maintenance of the aesthetic results and the peri-implant soft tissue without any inflammation or gingival recessions. Within the limitations of a case report, it can be conclude that zirconia abutments is a effective rehabilitation treatment because it preserves the aesthetics and function through the maintenance of peri-implant tissues.