245 resultados para Pacemaker


Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: Magnetic resonance imaging (MRI) of pacemakers is a relative contraindication because of the risks to the patient from potentially hazardous interactions between the MRI and the pacemaker system. Chest scans (ie, cardiac magnetic resonance scans) are of particular importance and higher risk. The previously Food and Drug Administration-approved magnetic resonance conditional system includes positioning restrictions, limiting the powerful utility of MRI. OBJECTIVE: To confirm the safety and effectiveness of a pacemaker system designed for safe whole body MRI without MRI scan positioning restrictions. METHODS: Primary eligibility criteria included standard dual-chamber pacing indications. Patients (n = 263) were randomized in a 2:1 ratio to undergo 16 chest and head scans at 1.5 T between 9 and 12 weeks postimplant (n = 177) or to not undergo MRI (n = 86) post-implant. Evaluation of the pacemaker system occurred immediately before, during (monitoring), and after MRI, 1-week post-MRI, and 1-month post-MRI, and similarly for controls. Primary end points measured the MRI-related complication-free rate for safety and compared pacing capture threshold between MRI and control subjects for effectiveness. RESULTS: There were no MRI-related complications during or after MRI in subjects undergoing MRI (n = 148). Differences in pacing capture threshold values from pre-MRI to 1-month post-MRI were minimal and similar between the MRI and control groups. CONCLUSIONS: This randomized trial demonstrates that the Advisa MRI pulse generator and CapSureFix MRI 5086MRI lead system is safe and effective in the 1.5 T MRI environment without positioning restrictions for MRI scans or limitations of body parts scanned.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A 2-kilogram child had a pacemaker implanted by a subxyphoid approach with the generator located under the rectus sheath. Days later, the battery eroded the abdominal wall and the peritoneum. The whole system was removed and a new one was implanted inside the pericardium on an emergent basis.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND Very few data exist on the clinical impact of permanent pacemaker implantation (PPI) after transcatheter aortic valve implantation. The objective of this study was to assess the impact of PPI after transcatheter aortic valve implantation on late outcomes in a large cohort of patients. METHODS AND RESULTS A total of 1556 consecutive patients without prior PPI undergoing transcatheter aortic valve implantation were included. Of them, 239 patients (15.4%) required a PPI within the first 30 days after transcatheter aortic valve implantation. At a mean follow-up of 22±17 months, no association was observed between the need for 30-day PPI and all-cause mortality (hazard ratio, 0.98; 95% confidence interval, 0.74-1.30; P=0.871), cardiovascular mortality (hazard ratio, 0.81; 95% confidence interval, 0.56-1.17; P=0.270), and all-cause mortality or rehospitalization for heart failure (hazard ratio, 1.00; 95% confidence interval, 0.77-1.30; P=0.980). A lower rate of unexpected (sudden or unknown) death was observed in patients with PPI (hazard ratio, 0.31; 95% confidence interval, 0.11-0.85; P=0.023). Patients with new PPI showed a poorer evolution of left ventricular ejection fraction over time (P=0.017), and new PPI was an independent predictor of left ventricular ejection fraction decrease at the 6- to 12-month follow-up (estimated coefficient, -2.26; 95% confidence interval, -4.07 to -0.44; P=0.013; R(2)=0.121). CONCLUSIONS The need for PPI was a frequent complication of transcatheter aortic valve implantation, but it was not associated with any increase in overall or cardiovascular death or rehospitalization for heart failure after a mean follow-up of ≈2 years. Indeed, 30-day PPI was a protective factor for the occurrence of unexpected (sudden or unknown) death. However, new PPI did have a negative effect on left ventricular function over time.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Low-threshold (T-type) Ca(2+) channels encoded by the Ca(V)3 genes endow neurons with oscillatory properties that underlie slow waves characteristic of the non-rapid eye movement (NREM) sleep EEG. Three Ca(V)3 channel subtypes are expressed in the thalamocortical (TC) system, but their respective roles for the sleep EEG are unclear. Ca(V)3.3 protein is expressed abundantly in the nucleus reticularis thalami (nRt), an essential oscillatory burst generator. We report the characterization of a transgenic Ca(V)3.3(-/-) mouse line and demonstrate that Ca(V)3.3 channels are indispensable for nRt function and for sleep spindles, a hallmark of natural sleep. The absence of Ca(V)3.3 channels prevented oscillatory bursting in the low-frequency (4-10 Hz) range in nRt cells but spared tonic discharge. In contrast, adjacent TC neurons expressing Ca(V)3.1 channels retained low-threshold bursts. Nevertheless, the generation of synchronized thalamic network oscillations underlying sleep-spindle waves was weakened markedly because of the reduced inhibition of TC neurons via nRt cells. T currents in Ca(V)3.3(-/-) mice were <30% compared with those in WT mice, and the remaining current, carried by Ca(V)3.2 channels, generated dendritic [Ca(2+)](i) signals insufficient to provoke oscillatory bursting that arises from interplay with Ca(2+)-dependent small conductance-type 2 K(+) channels. Finally, naturally sleeping Ca(V)3.3(-/-) mice showed a selective reduction in the power density of the σ frequency band (10-12 Hz) at transitions from NREM to REM sleep, with other EEG waves remaining unaltered. Together, these data identify a central role for Ca(V)3.3 channels in the rhythmogenic properties of the sleep-spindle generator and provide a molecular target to elucidate the roles of sleep spindles for brain function and development.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

bolism. Surgery was needed in 51% of cases and mortality was 42%. Prosthetic valve endocarditis (nine of 60, 13%) predominated in the aortic position and was associated with abscess formation, required surgery, and high mortality (78%). Pacemaker lead IE (seven of 69, 10%) is associated with a better prognosis when antibiotic treatment is combined with surgery. Conclusions:S lugdunensis IE is an uncommon cause of IE, involving mainly native left sided valves, and it is characterised by an aggressive clinical course. Mortality in left sided native valve IE is high but the prognosis has improved in recent years. Surgery has improved survival in left sided IE and, therefore, early surgery should always be considered. Prosthetic valve S lugdunensis IE carries an ominous prognosis.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

It has been shown that repolarization alternans, a beat-to-beat alternation in action potential duration, enhances dispersion of repolarization above a critical heart rate and promotes susceptibility to ventricular arrhythmias. It is unknown whether repolarization alternans is measurable in the atria using standard pacemakers and whether it plays a role in promoting atrial fibrillation. In this work, atrial repolarization alternans amplitude and periodicity are studied in a sheep model of pacing-induced atrial fibrillation. Two pacemakers, each with one right atrial and ventricular lead, were implanted in 4 male sheep after ablation of the atrioventricular junction. The first one was used to deliver rapid pacing for measurements of right atrial repolarization alternans and the second one to record a unipolar electrogram. Atrial repolarization alternans appeared rate-dependent and its amplitude increased as a function of pacing rate. Repolarization alternans was intermittent but no periodicity was detected. An increase of repolarization alternans preceding episodes of non-sustained atrial fibrillation suggests that repolarization alternans is a promising parameter for assessment of atrial fibrillation susceptibility.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

First-degree atrio-ventricular (AV) block is defined as a PR interval longer than 200 ms. If too long, it can become clinically relevant and may mimic a pacemaker syndrome. We report the case of a young woman with a long PR interval, probably congenital, with episodes of syncope and dizziness since childhood. Pseudo-pacemaker syndrome is rare and is a Class IIa recommendation for a pacemaker implantation. A dual-chamber pacemaker was implanted and short AV delay was programmed, with rapid clinical improvement.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: The efficacy of cardiac pacing for prevention of syncopal recurrences in patients with neurally mediated syncope is controversial. We wanted to determine whether pacing therapy reduces syncopal recurrences in patients with severe asystolic neurally mediated syncope. METHODS AND RESULTS: Double-blind, randomized placebo-controlled study conducted in 29 centers in the Third International Study on Syncope of Uncertain Etiology (ISSUE-3) trial. Patients were ≥40 years, had experienced ≥3 syncopal episodes in the previous 2 years. Initially, 511 patients, received an implantable loop recorder; 89 of these had documentation of syncope with ≥3 s asystole or ≥6 s asystole without syncope within 12 ± 10 months and met criteria for pacemaker implantation; 77 of 89 patients were randomly assigned to dual-chamber pacing with rate drop response or to sensing only. The data were analyzed on intention-to-treat principle. There was syncope recurrence during follow-up in 27 patients, 19 of whom had been assigned to pacemaker OFF and 8 to pacemaker ON. The 2-year estimated syncope recurrence rate was 57% (95% CI, 40-74) with pacemaker OFF and 25% (95% CI, 13-45) with pacemaker ON (log rank: P=0.039 at the threshold of statistical significance of 0.04). The risk of recurrence was reduced by 57% (95% CI, 4-81). Five patients had procedural complications: lead dislodgment in 4 requiring correction and subclavian vein thrombosis in 1 patient. CONCLUSIONS: Dual-chamber permanent pacing is effective in reducing recurrence of syncope in patients ≥40 years with severe asystolic neurally mediated syncope. The observed 32% absolute and 57% relative reduction in syncope recurrence support this invasive treatment for the relatively benign neurally mediated syncope. CLINICAL TRIAL REGISTRATION: URL: http://www.clinicaltrials.gov. Unique identifier: NCT00359203.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: Pacemaker implantation (PMI) may predispose to venous thromboembolism (VTE) and obstruction (VO). This prospective study aimed at quantifying changes in venous calibers, and at determining the incidence of symptomatic and asymptomatic VTE/VO after PMI. Further goals included an assessment of the role of transesophageal echocardiography (TEE) in the diagnosis of lead-related central venous thrombi (CVT), and determination of predictors for VTE/VO. Methods: 150 (mean age 67; 61% male) consecutive patients with first PMI were enrolled and followed for 6 months. Contrast venography was performed at baseline and 6 months after PMI to measure venous diameters, and to detect stenosis, total occlusions and thrombi. TEE was conducted in 66 patients. Based on clinical suspicion, work-up for pulmonary embolism (PE) or acute deep vein thrombosis (DVT) were performed as needed. A total of 50 cases underwent longer-term (mean 2.4 years) follow-up venography. All cases with VTE/VO during the initial 6 months, and their matched controls, were selected for a case-control study focused on possible predictive role of laboratory and patient-related factors for the development of VTE/VO. Results: 10 (7 %) patients were found to have baseline venous abnormalities (e.g. 8 obstructions). Mean venous diameters diminished significantly during the first 6 months, but no further reduction occurred in late follow-up. New VO was discovered in 19 patients (14 %; 14 stenosis, 5 total occlusions; all asymptomatic). Small non-obstructive thrombi were found in 20/140 (14 %) 6-month venograms. TEE at 6 months disclosed CVT in 6 (9 %) patients. One (0.7 %) patient had acute symptomatic upper-extremity DVT, and PE was discovered in 5/150 (3.3 %) patients during the first 6 months with no further cases thereafter. At 6 months, the total number of cases with VTE/VO amounted to 47 (31.3 %). Additionally, the later 2-year venograms (n=50) disclosed 4 (8 %) total occlusions and 1 (2 %) stenosis. In the case-control study, no parameter was predictive of venous end-points as a single variable, but there appeared to be significant clustering of traditional VTE risk-factors among the cases. Laboratory parameters showed a definite acute hypercoagulative state induced by PMI, but its degree did not predict subsequent development of VTE/VO. Conclusions: This study shows that VTE/VO is relatively common after PMI with an overall incidence of at least 30 %. Although the majority of the lesions are asymptomatic and clinically benign, cases of PE were also encountered, and totally occluded veins may hamper future upgrading or replacement of pacing system. Venous complications seem difficult to prognosticate as firm predictors were not identified from a wide range of parameters analyzed in this study, although clustering of classic VTE risk factors may be a predisposing factor. Parameters related to implantation procedure or pacing systems and the severity of implantation-induced trauma did not emerge as predictors.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

To various degrees, insects in nature adapt to and live with two fundamental environmental rhythms around them: (1) the daily rhythm of light and dark, and (2) the yearly seasonal rhythm of the changing photoperiod (length of light per day). It is hypothesized that two biological clocks evolved in organisms on earth which allow them to harmonize successfully with the two environmental rhythms: (1) the circadian clock, which orchestrates circadian rhythms in physiology and behavior, and (2) the photoperiodic clock, which allows for physiological adaptations to changes in photoperiod during the course of the year (insect photoperiodism). The circadian rhythm is endogenous and continues in constant conditions, while photoperiodism requires specific light inputs of a minimal duration. Output pathways from both clocks control neurosecretory cells which regulate growth and reproduction. This dissertation focuses on the question whether different photoperiods change the network and physiology of the circadian clock of an originally equatorial cockroach species. It is assumed that photoperiod-dependent plasticity of the cockroach circadian clock allows for adaptations in physiology and behavior without the need for a separate photoperiodic clock circuit. The Madeira cockroach Rhyparobia maderae is a well established circadian clock model system. Lesion and transplantation studies identified the accessory medulla (aMe), a small neuropil with about 250 neurons, as the cockroach circadian pacemaker. Among them, the pigment-dispersing factor immunoreactive (PDF-ir) neurons anterior to the aMe (aPDFMes) play a key role as inputs to and outputs of the circadian clock system. The aim of my doctoral thesis was to examine whether and how different photoperiods modify the circadian clock system. With immunocytochemical studies, three-dimensional (3D) reconstruction, standardization and Ca2+-imaging technique, my studies revealed that raising cockroaches in different photoperiods changed the neuronal network of the circadian clock (Wei and Stengl, 2011). In addition, different photoperiods affected the physiology of single, isolated circadian pacemaker neurons. This thesis provides new evidence for the involvement of the circadian clock in insect photoperiodism. The data suggest that the circadian pacemaker system of the Madeira cockroach has the plasticity and potential to allow for physiological adaptations to different photoperiods. Therefore, it may express also properties of a photoperiodic clock.