993 resultados para PLASMA-LEAD
Resumo:
This paper describes methods for the direct determination of Cd and Pb in hair segments (c.a. 5 mm similar to 80 mu g) by solid sampling graphite furnace atomic absorption spectrometry, becoming possible longitudinal profiles in a single strand of hair. To distinguish endogenous and exogenous content. strands of hair were washed by using two different procedures: IAEA protocol (acetone + water + acetone) and the combination of IAEA protocol with HCl washing (acetone + water + acetone + 0.1 mol l(-1) HCl). The concentration of Cd and Pb increased from the root Until the tip of hair washed according to IAEA protocol. However, when the strand of hair was washed using the combination of IAEA protocol and 0.1 mol l(-1) HCl, Cd concentrations decreased in all segments, and Pb concentrations decreased drastically near to the root (5 to 12 mm) and was systematically higher ill the end. The proposed method showed to be useful to assess the temporal variation to Cd and Pb exposure and call be Used for toxicological and environmental investigations. The limits of detection were 2.8 ng g(-1) for Cd and 40 ng g(-1) for Pb. The characteristic masses based oil integrated absorbance were 2.4 pg for Cd and 22 pg for Pb.
Resumo:
A procedure for simultaneous separation/preconcentration of copper. zinc, cadmium, and nickel in water samples, based on cloud point extraction (CPE) as a prior step to their determination by inductively coupled plasma optic emission spectrometry (ICP-OES), has been developed. The analytes reacted with 4-(2-pyridylazo)-resorcinol (PAR) at pH 5 to form hydrophobic chelates, which were separated and preconcentrated in a surfactant-rich phase of octylphenoxypolyethoxyethanol (Triton X-I 14). The parameters affecting the extraction efficiency of the proposed method, such as sample pH, complexing agent concentration, buffer amount, surfactant concentration, temperature, kinetics of complexation reaction, and incubation time were optimized and their respective values were 5, 0.6 mmol L(-1). 0.3 mL, 0.15% (w/v), 50 degrees C, 40 min, and 10 min for 15 mL of preconcentrated solution. The method presented precision (R.S.D.) between 1.3% and 2.6% (n = 9). The concentration factors with and without dilution of the surfactant-rich phase for the analytes ranged from 9.4 to 10.1 and from 94.0 to 100.1, respectively. The limits of detection (L.O.D.) obtained for copper, zinc, cadmium, and nickel were 1.2, 1.1, 1.0. and 6.3 mu g L(-1), respectively. The accuracy of the procedure was evaluated through recovery experiments on aqueous samples. (C) 2009 Published by Elsevier B.V.
Resumo:
Adsorbent and corrosion resistant films are useful for sensor development. Therefore, the aim of this work is the production and characterization of plasma polymerized fluorinated organic ether thin films for sensor development. The polymerized reactant was methyl nonafluoro(iso)butyl ether. Infrared Spectroscopy showed fluorinated species and eventually CO but CH(n) is a minor species. Contact angle measurements indicated that the film is hydrophobic and organophilic but oleophobic. Optical microscopy reveals not only a good adherence on metals and acrylic but also resistance for organic solvents, acid and basic aqueous solution exposure. Double layer and intermixing are possible and might lead to island formation. Quartz Crystal Microbalance showed that 2-propanol permeates the film but there is no sensitivity to n-hexane. The microreactor manufactured using a 73 cm long microchannel can retain approximately 9 X 10(-4) g/cm(2) of 2-propanol in vapor phase. Therefore, the film is a good candidate for preconcentration of volatile organic compounds even in corrosive environment. (C) 2009 Elsevier B.V. All rights reserved.
Resumo:
Lead (Pb) is recognized as one of the most toxic metals. Sources of Pb exposure have been widely documented in North America, and the removal of Pb additives from gasoline was reflected in a dramatic lowering of blood Pb concentration. In Latin America, the removal of Pb from gasoline resulted in decreased exposure, but Pb levels in many areas remain high due to occupational and environmental sources of exposure. While many of the Pb sources have been identified (mining, industries, battery recycling, lead-based paint, ceramics), new ones occasionally crop up. Here we report on blood Pb (B-Pb) levels in remote riverside communities of the Brazilian Amazon. Blood Pb (B-Pb) levels were determined in 448 persons from 12 villages of the Lower Tapajos River Basin, Par, Brazil. Socio-demographic and dietary information, as well as occupational, residential and medical history was collected using an interview-administered questionnaire. B-Pb, measured by ICP-MS, showed elevated concentrations. Mean B-Pb was 13.1 mu g/dL +/- 8.5, median B-Pb was 11.2 mu g/dL and ranged from 0.59 to 48.3 mu g/dL. Men had higher B-Pb compared to women (median: 15.3 mu g/dL vs 7.9 mu g/dL respectively). B-Pb increased with age for women, while it decreased for men. For both genders, B-Pb decreased with education. There were significant differences between villages. Exploratory analyses, using linear partition models, showed that for men B-Pb was lower among those who were involved in cattle-raising, and higher among those who hunted, farmed and fished. The distribution profile of B-Pb directed us towards artisanal transformation of manioc to flour (farinha), which requires heating in a large metal pan, with stirring primarily done by young men. In the village with the highest B-Pb, analysis of Pb concentrations (dry weight) of manioc (prior to transformation) and farinha (following transformation) from 6 houses showed a tenfold increase in Pb concentration (mean: 0.017 +/- 0.016 to 0.19 +/- 0.10 mu g/g). This was confirmed in one of these villages where we sampled manioc paste Oust before roasting) and the roasted farinha (0.05 mu g/g vs 0.20 mu g/g). While there may be other sources (ammunition, sinkers for fishing nets), the high concentrations in farinha, a dietary staple, assuredly makes an important contribution. Further action needs to reduce Pb sources in this region. (C) 2009 Elsevier Inc. All rights reserved.
Resumo:
Introduction: Whole blood is used for diagnosis of lead exposure. A non-invasive method to obtain samples for the biomonitoring of lead contamination has become a necessity. This study 1) compares the lead content in whole saliva samples (Pb-saliva) of children from a city with no reported lead contamination (Ribeirao Preto, Sao Paulo State, Brazil) and children of a region notoriously contaminated with lead (Bauru, Sao Paulo State, Brazil), and 2) correlates Pb-saliva with the lead content in the enamel microbiopsy samples (Pb-enamel) in the case of these two populations. Methods: From a population of our previous study that had included 247 children (4- to 6-year-old) from Ribeirao Preto, and 26 children from Bauru, Pb-saliva was analyzed in 125 children from Ribeirdo Preto and 19 children from Bauru by inductively coupled plasma mass spectrometry (ICPMS). To correlate Pb-saliva with Pb-enamel, we used Pb-enamel data obtained in our previous study. The Mann-Whitney test was employed to compare the Pb-saliva data of the two cities. Pb-saliva and Pb-enamel values were then Log(10) transformed to normalize data, and Pb-saliva and Pb-enamel were correlated using Pearson`s correlation coefficient. Results: Median Pb-saliva from the Ribeirao Preto population (1.64 mu g/L) and the Bauru population (5.85 mu g/L) were statistically different (p<0.0001). Pearson`s correlation coefficient for Log(10) Pb-saliva versus Log(10) Pb-enamel was 0.15 (p=0.08) for Ribeirao Preto and 0.38 (p=0.11) for Bauru. Conclusions: A clear relationship between Pb-saliva and environmental contamination by lead is shown. Further studies on Pb-saliva should be undertaken to elucidate the usefulness of saliva as a biomarker of lead exposure, particularly in children. (C) 2008 Elsevier B.V. All rights reserved.
Resumo:
Lead (Pb) contamination in the black paper that recovers intraoral films (BKP) has been investigated. BKP samples were collected from the Radiology Clinics of the Dental School of Ribeirao Preto, University of Sao Paulo, Brazil. For sake of comparison, four different methods were used. The results revealed the presence of high lead levels, well above the maximum limit allowed by the legislation. Pb contamination levels achieved after the following treatments: paper digestion in nitric acid, microwave treatment, DIN38414-54 method and TCLP method were 997 mu g g(-1), 189 mu g g(-1), 20.8 mu g g(-1), and 54.0 mu g g(-1), respectively. Flame atomic absorption spectrometry (FAAS) and inductively coupled plasma mass spectrometry (ICP-MS) were employed for lead determination according to the protocols of the applied methods. Lead contamination in used BKP was confirmed by scanning electron microscopy coupled with energy dispersive X-ray microanalysis (SEM-EDS). All the SEM imaging was carried out in the secondary electron mode (SE) and backscattered-electron mode (QBSD) following punctual X-ray fluorescence spectra. Soil contamination derived from this product revealed the urgent need of addressing this problem. These elevated Pb levels, show that a preliminary treatment of BKP is mandatory before it is disposed into the common trash. The high lead content of this material makes its direct dumping into the environment unwise. (C) 2009 Elsevier B.V. All rights reserved.
Resumo:
Background and Aim: There were strong evidences that nitric oxide has capital importance in the progressive vasodilatation associated with varied circulatory shock forms, including systemic inflammatory response syndrome (SIRS), in patients undergoing cardiac surgeries for cardiopulmonary bypass (CPB). If CPB procedures, per se, are the inciting stimulus for inflammation, plasma nitrate/nitrite (NOx) excretion would be expected to be higher in these patients rather than in patients operated without CPB. In consequence, we hypothesized that increased levels of NOx would be predictive for vasoplegic syndrome. Methods: Thirty patients were assigned to three groups: Group 1-coronary artery bypass graft (CABG) roller pump CPB; Group 2-CABG centrifugal vortex pump CPB; and Group 3-heart valve surgery roller pump CPB. Sampling of venous blood for chemiluminescence plasma NOx dosage was achieved at the following time points: (1) before anesthesia induction; (2) after anesthesia induction; (3) before heparin infusion; (4) after heparin infusion; (5) CPB-30 minutes; (6) CPB-60 minutes; (7) before protamine infusion; (8) after protamine infusion; and (9) on return to the recovery area. Results: There were no intergroup differences regarding age and anesthetic regimen, and the number of arteries grafted was not different between the CABG groups. There were no NOx statistic differences, neither among the three groups of patients or among the surgery time. In addition, there was no correlation among NOx, lactate, and hemoglobin. Conclusions: Considering the inflammatory process intrinsic to CPB, this study reinforces the idea that plasma NOx is not useful as a biomarker of inflammatory response onset, which may or may not lead to SIRS and/or vasoplegic syndrome.
Resumo:
The advantages of using cryopreserved semen in equine reproduction are well known. During cryopreservationl spermatozoa undergo many changes that lead to a decrease in fertility. There is no agreement on the ideal sperm dose and concentration to maximize fertility rates. Thus, the objectives of this experiment were to evaluate sperm motion by computer-assisted analysis (CASA), sperm membrane integrity and function with fluorescence probes of cryopreserved sperm at three concentrations: 100 (C100), 200 (C200) and 400 x 10(6) sperm/mL (C400), and two straw volumes (0.50 and 0.25 mL). There was no interaction between sperm concentration and storage volume (P > .05). Sperm motion characteristics were influenced by concentration (C100 > C200 > C400; P < .05). Curvilinear velocity (VCL) in 0.25-mL straws had higher average values (P < .05). Membrane integrity and function were not changed by straw volume (P > .05). However, sperm concentration changed the percentage of cells with intact plasma membrane (C100 > C200 > C400; P < .05) and the percentage of cells with high mitochondrial membrane potential (C100 = C200; P > .05 and C400 < C100 and C200; P < .05). According to this experiment, the best freeing method was that involving 100 x 10(6) sperm/mL, regardless of straw volume.
Resumo:
Like fluoride, lead (Pb) accumulates on the enamel surface pre-eruptively, but it is not yet known whether it also deposits on enamel while dental caries is developing. This study evaluates Pb distribution in bovine enamel slabs submitted to a pH-cycling regimen simulating the caries process. The slabs were subjected to 8 cycles of de- and remineralizing conditions, and Pb (as acetate salt) was added to the de- and remineralized solutions at concentrations of 30 mu g/l (experimental group, E1) and 300 mu g/l (experimental group, E2). The control group (C) consisted of solutions to which Pb was not added. After the pH cycling, 100-mu m sections of the slabs were analyzed by polarizing microscopy, to observe the extent of caries-like lesions, and these sections were used for Pb estimation by Synchrotron radiation X-ray microfluorescence. Caries lesions were observed along all superficial enamel surfaces to an extent of 120 mu m. A Pb concentration gradient was observed in enamel, which decreased toward dentine. The highest Pb signals were observed for group E2, and the differences were statistically significant at enamel depths of 0 (C vs. E2; p = 0.029) and 50 mu m (C vs. E2 and E1 vs. E2; p = 0.029). In conclusion, this study suggests that if Pb is present in the oral environment, it may deposit in enamel during the caries process. Copyright (C) 2011 S. Karger AG, Basel
Resumo:
OBJECTIVE: To analyze household risk factors associated with high lead levels in surface dental enamel. METHODS: A cross-sectional study was conducted with 160 Brazilian adolescents aged 14-18 years living in poor neighborhoods in the city of Bauru, southeastern Brazil, from August to December 2008. Body lead concentrations were assessed in surface dental enamel acid-etch microbiopsies. Dental enamel lead levels were measured by graphite furnace atomic absorption spectrometry and phosphorus levels were measured by inductively coupled plasma optical emission spectrometry. The parents answered a questionnaire about their children's potential early (05 years old) exposure to well-known lead sources. Logistic regression was used to identify associations between dental enamel lead levels and each environmental risk factor studied. Social and familial covariables were included in the models. RESULTS: The results suggest that the adolescents studied were exposed to lead sources during their first years of life. Risk factors associated with high dental enamel lead levels were living in or close to a contaminated area (OR = 4.49; 95% CI: 1.69;11.97); and member of the household worked in the manufacturing of paints, paint pigments, ceramics or batteries (OR = 3.43; 95% CI: 1.31;9.00). Home-based use of lead-glazed ceramics, low-quality pirated toys, anticorrosive paint on gates and/or sale of used car batteries (OR = 1.31; 95% CI: 0.56;3.03) and smoking (OR = 1.66; 95% CI: 0.52;5.28) were not found to be associated with high dental enamel lead levels. CONCLUSIONS: Surface dental enamel can be used as a marker of past environmental exposure to lead and lead concentrations detected are associated to well-known sources of lead contamination.
Resumo:
Clozapine, an atypical antipsychotic, depends mainly on cytochrome P4501A2 (CYP1A2) for its metabolic clearance. CYP1A2 is inducible by smoking, and lower plasma concentrations of clozapine are measured in smokers than in nonsmokers. Case reports have been published on the effects of discontinuing smoking in patients receiving clozapine, which might lead to elevated plasma concentrations and severe side effects. We present 2 cases on the consequences of smoking cessation in patients receiving this drug. In the first patient, smoking cessation resulted, within 2 weeks, in severe sedation and fatigue, with an approximately 3-fold increase of plasma clozapine concentrations. In the second patient, a very high plasma concentration of clozapine (3004 ng/mL) was measured 6 days following a 16-day stay in a general hospital, during which smoking was prohibited. In the latter patient, the replacement of omeprazole, a strong CYP1A2 inducer, by pantoprazole, a weaker CYP1A2 inducer, could have contributed, in addition to smoking cessation, to the observed strong increase of plasma clozapine concentrations. Genotyping of the 2 patients revealed that they were carriers of the AA genotype for the -164C>A polymorphism (CYP1A2*1F) in intron 1 of CYP1A2 gene, which has previously been shown to confer a high inducibility of CYP1A2 by smoking. Thus, at the initiation of clozapine treatment, smoking patients should be informed that, if they decide to stop smoking, they are encouraged to do so but must inform their prescriber beforehand. Also, because of the increased use of no-smoking policies in many hospitals, studies examining the consequences of such policies on the pharmacokinetics/pharmacodynamics of drugs metabolized by CYP1A2, taking into account different CYP1A2 genotypes, are needed.
Resumo:
BACKGROUND: Early virological failure of antiretroviral therapy associated with the selection of drug-resistant human immunodeficiency virus type 1 in treatment-naive patients is very critical, because virological failure significantly increases the risk of subsequent failures. Therefore, we evaluated the possible role of minority quasispecies of drug-resistant human immunodeficiency virus type 1, which are undetectable at baseline by population sequencing, with regard to early virological failure. METHODS: We studied 4 patients who experienced early virological failure of a first-line regimen of lamivudine, tenofovir, and either efavirenz or nevirapine and 18 control patients undergoing similar treatment without virological failure. The key mutations K65R, K103N, Y181C, M184V, and M184I in the reverse transcriptase were quantified by allele-specific real-time polymerase chain reaction performed on plasma samples before and during early virological treatment failure. RESULTS: Before treatment, none of the viruses showed any evidence of drug resistance in the standard genotype analysis. Minority quasispecies with either the M184V mutation or the M184I mutation were detected in 3 of 18 control patients. In contrast, all 4 patients whose treatment was failing had harbored drug-resistant viruses at low frequencies before treatment, with a frequency range of 0.07%-2.0%. A range of 1-4 mutations was detected in viruses from each patient. Most of the minority quasispecies were rapidly selected and represented the major virus population within weeks after the patients started antiretroviral therapy. All 4 patients showed good adherence to treatment. Nonnucleoside reverse-transcriptase inhibitor plasma concentrations were in normal ranges for all 4 patients at 2 separate assessment times. CONCLUSIONS: Minority quasispecies of drug-resistant viruses, detected at baseline, can rapidly outgrow and become the major virus population and subsequently lead to early therapy failure in treatment-naive patients who receive antiretroviral therapy regimens with a low genetic resistance barrier.
Resumo:
The fast simultaneous hadronization and chemical freeze-out of supercooled quark-gluon plasma, created in relativistic heavy ion collisions, can lead to the reheating of the expanding matter and to the change in a collective flow profile. We use the assumption of statistical nature of the hadronization process, and study quantitatively the freeze-out in the framework of hydrodynamical Bjorken model with different simple quark-gluon plasma equations of state.
Resumo:
High performance liquid chromatography (HPLC) is the reference method for measuring concentrations of antimicrobials in blood. This technique requires careful sample preparation. Protocols using organic solvents and/or solid extraction phases are time consuming and entail several manipulations, which can lead to partial loss of the determined compound and increased analytical variability. Moreover, to obtain sufficient material for analysis, at least 1 ml of plasma is required. This constraint makes it difficult to determine drug levels when blood sample volumes are limited. However, drugs with low plasma-protein binding can be reliably extracted from plasma by ultra-filtration with a minimal loss due to the protein-bound fraction. This study validated a single-step ultra-filtration method for extracting fluconazole (FLC), a first-line antifungal agent with a weak plasma-protein binding, from plasma to determine its concentration by HPLC. Spiked FLC standards and unknowns were prepared in human and rat plasma. Samples (240 microl) were transferred into disposable microtube filtration units containing cellulose or polysulfone filters with a 5 kDa cut-off. After centrifugation for 60 min at 15000g, FLC concentrations were measured by direct injection of the filtrate into the HPLC. Using cellulose filters, low molecular weight proteins were eluted early in the chromatogram and well separated from FLC that eluted at 8.40 min as a sharp single peak. In contrast, with polysulfone filters several additional peaks interfering with the FLC peak were observed. Moreover, the FLC recovery using cellulose filters compared to polysulfone filters was higher and had a better reproducibility. Cellulose filters were therefore used for the subsequent validation procedure. The quantification limit was 0.195 mgl(-1). Standard curves with a quadratic regression coefficient > or = 0.9999 were obtained in the concentration range of 0.195-100 mgl(-1). The inter and intra-run accuracies and precisions over the clinically relevant concentration range, 1.875-60 mgl(-1), fell well within the +/-15% variation recommended by the current guidelines for the validation of analytical methods. Furthermore, no analytical interference was observed with commonly used antibiotics, antifungals, antivirals and immunosuppressive agents. Ultra-filtration of plasma with cellulose filters permits the extraction of FLC from small volumes (240 microl). The determination of FLC concentrations by HPLC after this single-step procedure is selective, precise and accurate.
Resumo:
OBJECTIVES: The diagnosis of pheochromocytoma relies on the measurement of plasma free metanephrines assay whose reliability has been considerably improved by ultra-high pressure liquid chromatography tandem mass spectrometry (UHPLC-MS/MS). Here we report an analytical interference occurring between 4-hydroxy-3-methoxymethamphetamine (HMMA), a metabolite of 3,4-methylenedioxymethamphetamine (MDMA, "Ecstasy"), and normetanephrine (NMN) since they share a common pharmacophore resulting in the same product ion after fragmentation. DESIGN AND METHODS: Synthetic HMMA was spiked into plasma samples containing various concentrations of NMN and the intensity of the interference was determined by UPLC-MS/MS before and after improvement of the analytical method. RESULTS: Using a careful adjustment of chromatographic conditions including the change of the UPLC analytical column, we were able to distinguish both compounds. HMMA interference for NMN determination should be seriously considered since MDMA activates the sympathetic nervous system and if confounded with NMN may lead to false-positive tests when performing a differential diagnostic of pheochromocytoma.