983 resultados para PERIVASCULAR DRAINAGE
Resumo:
In sub-humid South India, recent studies have shown that black soil areas (Vertisols and vertic Intergrades), located on flat valley bottoms, have been rejuvenated through the incision of streambeds, inducing changes in the pedoclimate and soil transformation. Joint pedological, geochemical and geophysical investigations were performed in order to better understand the ongoing processes and their contribution to the chemistry of local rivers. The seasonal rainfall causes cycles of oxidation and reduction in a perched watertable at the base of the black soil, while the reduced solutions are exported through a loamy sand network. This framework favours a ferrolysis process, which causes low base saturation and protonation of clay, leading to the weathering of 2:1 then 1:1 clay minerals. Maximum weathering conditions occur at the very end of the wet season, just before disappearance of the perched watertable. Therefore, the by-products of soil transformation are partially drained off and calcareous nodules, then further downslope, amorphous silica precipitate upon soil dehydration. The ferrolysed area is fringing the drainage system indicating that its development has been induced by the streambed incision. The distribution of (14)C ages of CaCO(3) nodules suggests that the ferrolysis process started during the late Holocene, only about 2 kyr B.P. at the studied site and about 5 kyr B.P. at the watershed outlet. The results of this study are applied to an assessment of the physical erosion rate (4.8x10(-3) m/kyr) since the recent reactivation of the erosion process. (C) 2010 Elsevier B.V. All rights reserved.
Resumo:
Background. Bilioduodenal (BD) and biliojejunal (BJ) derivation induce enterobiliary reflux and bile stasis. Decompression of the excluded loop of the Roux-en-Y (BJD) was proposed to minimize these effects. The aim of this study was to compare the influence of these three modalities of biliary bypass on hepatic lesion repair in rats with secondary biliary fibrosis. Materials and Methods. Rats with 15 d of biliary obstruction underwent BD, BJ, and BJD drainage and were compared with a group submitted to simulated operation (SO) and biliary obstruction (CBO). The serum values of total and fractional bilirubin, alkaline phosphatase (ALP), and aminotransferases (AST and ALT), as well as hepatobiliointestinal excretion determined with (99m)Tc-Disida, were used for comparison. In addition, we used morphometric analyses to estimate the mass of the hepatocytes, bile ducts, and liver fibrosis. We also counted hepatic stellate cells (SC). Results. For each of the three modalities of biliary drainage, there were significant reductions in bilirubin, AST, ALP, and the number of SCs. The recovery of the estimated mass of all histologic components occurred only after BJ and BJD; in the BD group, the estimated hepatocyte mass was reduced compared with the SO group. The residual hepatic radioactivity of (99m)Tc-Disida was greater in the BJD group than in the SO group. Conclusions. The interposition of the jejunal loop between the biliary tree and the intestine may slow hepatobiliary clearance of radioactivity, even though it provides the resolution of cholestasis and is effective in recovering from hepatic lesions. (C) 2011 Elsevier Inc. All rights reserved.
Resumo:
Objective. The relationship of multipotent mesenchymal stromal cells (MSC) with pericytes and fibroblasts has not been established thus far, although they share many markers of primitive marrow stromal cells and the osteogenic, adipogenic, and chondrogenic differentiation potentials. Materials and Methods. We compared MSCs from adult or fetal tissues, MSC differentiated in vitro, fibroblasts and cultures of retinal pericytes obtained either by separation with anti-CD146 or adhesion. The characterizations included morphological, immunophenotypic, gene-expression profile, and differentiation potential. Results. Osteogenic, adipocytic, and chondrocytic differentiation was demonstrated for MSC, retinal perivascular cells, and fibroblasts. Cell morphology and the phenotypes defined by 22 markers were very similar. Analysis of the global gene expression obtained by serial analysis of gene expression for 17 libraries and by reverse transcription polymerase chain reaction of 39 selected genes from 31 different cell cultures, revealed similarities among MSC, retinal perivascular cells, and hepatic stellate cells. Despite this overall similarity, there was a heterogeneous expression of genes related to angiogenesis, in MSC derived from veins, artery, perivascular cells, and fibroblasts. Evaluation of typical pericyte and MSC transcripts, such as NG2, CD146, CD271, and CD140B on CD146 selected perivascular cells and MSC by real-time polymerase chain reaction confirm the relationship between these two cell types. Furthermore, the inverse correlation between fibroblast-specific protein-1 and CD146 transcripts observed on pericytes, MSC, and fibroblasts highlight their potential use as markers of this differentiation pathway. Conclusion. Our results indicate that human MSC and pericytes are similar cells located in the wall of the vasculature, where they function as cell sources for repair and tissue maintenance, whereas fibroblasts are more differentiated cells with more restricted differentiation potential. (C) 2008 ISEH - Society for Hematology and Stem Cells. Published by Elsevier Inc.
Resumo:
A review of spontaneous rupture in thin films with tangentially immobile interfaces is presented that emphasizes the theoretical developments of film drainage and corrugation growth through the linearization of lubrication theory in a cylindrical geometry. Spontaneous rupture occurs when corrugations from adjacent interfaces become unstable and grow to a critical thickness. A corrugated interface is composed of a number of waveforms and each waveform becomes unstable at a unique transition thickness. The onset of instability occurs at the maximum transition thickness, and it is shown that only upper and lower bounds of this thickness can be predicted from linear stability analysis. The upper bound is equivalent to the Freakel criterion and is obtained from the zeroth order approximation of the H-3 term in the evolution equation. This criterion is determined solely by the film radius, interfacial tension and Hamaker constant. The lower bound is obtained from the first order approximation of the H-3 term in the evolution equation and is dependent on the film thinning velocity A semi-empirical equation, referred to as the MTR equation, is obtained by combining the drainage theory of Manev et al. [J. Dispersion Sci. Technol., 18 (1997) 769] and the experimental measurements of Radoev et al. [J. Colloid Interface Sci. 95 (1983) 254] and is shown to provide accurate predictions of film thinning velocity near the critical thickness of rupture. The MTR equation permits the prediction of the lower bound of the maximum transition thickness based entirely on film radius, Plateau border radius, interfacial tension, temperature and Hamaker constant. The MTR equation extrapolates to Reynolds equation under conditions when the Plateau border pressure is small, which provides a lower bound for the maximum transition thickness that is equivalent to the criterion of Gumerman and Homsy [Chem. Eng. Commun. 2 (1975) 27]. The relative accuracy of either bound is thought to be dependent on the amplitude of the hydrodynamic corrugations, and a semiempirical correlation is also obtained that permits the amplitude to be calculated as a function of the upper and lower bound of the maximum transition thickness. The relationship between the evolving theoretical developments is demonstrated by three film thickness master curves, which reduce to simple analytical expressions under limiting conditions when the drainage pressure drop is controlled by either the Plateau border capillary pressure or the van der Waals disjoining pressure. The master curves simplify solution of the various theoretical predictions enormously over the entire range of the linear approximation. Finally, it is shown that when the Frenkel criterion is used to assess film stability, recent studies reach conclusions that are contrary to the relevance of spontaneous rupture as a cell-opening mechanism in foams. (C) 2003 Elsevier Science B.V. All rights reserved.
Resumo:
Coffee cultivation via central-pivot fertigation can lead to fertilizer losses by soil profile internal drainage when water application is excessive and soils have low water retention and cation adsorption capacities. This study analyses the deep water losses from the top 1 m sandy soil layer of east Bahia, Brazil, cultivated with coffee at a high technology level (central-pivot fertigation), using above normal N fertilizer rates. The deep drainage (Q) estimation is made through the application of a climatologic water balance (CWB) program having as input direct measures of irrigation and rainfall, climatological data from weather stations, and measured soil water retention characteristics. The aim of the study is to contribute to the understanding of the hydric regime of coffee crops managed by central-pivot irrigation, analyzing three scenarios (Sc): i) rainfall only, ii) rainfall and irrigation full year, and iii) rainfall and irrigation dry season only. Annual Q values for the 2008/2009 agricultural year were: Sc i = 811.5 mm; Sc ii = 1010.5 mm; and Sc iii = 873.1 mm, so that the irrigation interruption in the wet season reduced Q by 15.7%, without the appearance of water deficit periods. Results show that the use of the CWB program is a convenient tool for the evaluation of Q under the cited conditions.
Resumo:
The presented work was conducted within the Dissertation / Internship, branch of Environmental Protection Technology, associated to the Master thesis in Chemical Engineering by the Instituto Superior de Engenharia do Porto and it was developed in the Aquatest a.s, headquartered in Prague, in Czech Republic. The ore mining exploitation in the Czech Republic began in the thirteenth century, and has been extended until the twentieth century, being now evident the consequences of the intensive extraction which includes contamination of soil and sub-soil by high concentrations of heavy metals. The mountain region of Zlaté Hory was chosen for the implementation of the remediation project, which consisted in the construction of three cells (tanks), the first to raise the pH, the second for the sedimentation of the formed precipitates and a third to increase the process efficiency in order to reduce high concentrations of metals, with special emphasis on iron, manganese and sulfates. This project was initiated in 2005, being pioneer in this country and is still ongoing due to the complex chemical and biological phenomenon’s inherent to the system. At the site where the project was implemented, there is a natural lagoon, thereby enabling a comparative study of the two systems (natural and artificial) regarding the efficiency of both in the reduction/ removal of the referred pollutants. The study aimed to assist and cooperate in the ongoing investigation at the company Aquatest, in terms of field work conducted in Zlaté Hory and in terms of research methodologies used in it. Thereby, it was carried out a survey and analysis of available data from 2005 to 2008, being complemented by the treatment of new data from 2009 to 2010. Moreover, a theoretical study of the chemical and biological processes that occurs in both systems was performed. Regarding the field work, an active participation in the collection and in situ sample analyzing of water and soil from the natural pond has been attained, with the supervision of Engineer, Irena Šupiková. Laboratory analysis of water and soil were carried out by laboratory technicians. It was found that the natural lagoon is more efficient in reducing iron and manganese, being obtained removal percentages of 100%. The artificial lagoon had a removal percentage of 90% and 33% for iron and manganese respectively. Despite the minor efficiency of the constructed wetland, it must be pointed out that this system was designed for the treatment and consequent reduction of iron. In this context, it can conclude that the main goal has been achieved. In the case of sulphates, the removal optimization is yet a goal to be achieved not only in the Czech Republic but also in other places where this type of contamination persists. In fact, in the natural lagoon and in the constructed wetland, removal efficiencies of 45% and 7% were obtained respectively. It has been speculated that the water at the entrance of both systems has different sources. The analysis of the collected data shows at the entrance of the natural pond, a concentration of 4.6 mg/L of total iron, 14.6 mg/L of manganese and 951 mg/L of sulphates. In the artificial pond, the concentrations are 27.7 mg/L, 8.1 mg/L and 382 mg/L respectively for iron, manganese and sulphates. During 2010 the investigation has been expanded. The study of soil samples has started in order to observe and evaluate the contribution of bacteria in the removal of heavy metals being in its early phase. Summarizing, this technology has revealed to be an interesting solution, since in addition to substantially reduce the mentioned contaminants, mostly iron, it combines the low cost of implementation with an reduced maintenance, and it can also be installed in recreation parks, providing habitats for plants and birds.
Resumo:
The development and implementation of measures which promote the reduction of the impacts of forest fires on soils is imperative and should be part of any strategy for forest and soil preservation and recovery, especially considering the actual scenario of continuous growth in the number of fires and burnt area. Consequently, with the dendrocaustologic reality that has characterized the Portuguese mainland in recent decades, a research project promoted by the Center for the Study of Geography and Spatial Planning (CEGOT) was implemented with the objective of applying several erosion mitigation measures in a burned area of the Peneda-Geres National Park in NW Portugal. This paper therefore seeks to present the measures applied in the study area within the project Soil Protec, relating to triggered channel processes and the results of preliminary observations concerning the evaluation of the effectiveness of erosion mitigation measures implemented, as well as their cost/benefit ratio.
Resumo:
v.37:no.3(1955)
Resumo:
RESUME DE THESEContexte de l'étudeLe but de cette étude est de comparer le drainage percutané (DP) et la chirurgie d'urgence (CU) de la vésicule biliaire (VB) pour le traitement de la cholécystite aiguë lithiasique/alithiasique dans un groupe homogène de patients gravement malades et hospitalisés aux soins intensifs (SI).Patients et méthodeEntre les années 2001 et 2007, tous les patients successivement traités par DP ou CU pour cholécystite aiguë aux SI ont été rétrospectivement analysés. Les cas ont été collectés à partir d'une base de données prospective. Le DP était effectué par voie trans-hépatique et la chirurgie par voie ouverte ou laparoscopique. L'état général des patients et la dysfonction des organes étaient évalués par deux scores validés (SAPS Π et SOFA, respectivement). L'analyse des données s'est portée sur les complications à court terme (morbidité, mortalité hospitalière) et à long terme (récurrence des symptômes) après drainage ou chirurgie en urgence.RésultatsQuarante-deux patients (âge médian 65 ans, 32-94 ans) ont été inclus dans l'étude ; 45% ont eu une CU (10 laparoscopics, 9 voies ouvertes) et 55% un DP (n=23) de la vésicule biliaire. Le DP et la CU ont eu des taux de succès respectifs de 91 et 100% pour la résolution du sepsis lié à la cholécystite aigiie. Après drainage et chirurgie de la VB, la dysfonction des organes secondaire au sepsis s'est résolue dans les 3 jours. Malgré le drainage, deux patients ont nécessité une cholécystectomie en urgence pour cholécystite gangréneuse. Le taux de conversion de la laparoscopic à la voie ouverte était de 20%. La morbidité majeure était de 0% après drainage et 21% après chirurgie en urgence (p=0.034). Finalement, la mortalité hospitalière était similaire (13% après DP vs. 16% après CU, p=1.0) et uniquement liée aux co-morbidités des patients. La récurrence des symptômes liés à la VB n'est apparue que chez des patients initialement drainés pour cholécystite lithiasique.ConclusionsChez les patients gravement malades des soins intensifs, le drainage percutané et la chirurgie en urgence de la VB sont tous deux efficaces pour la résolution d'un sepsis lié à une cholécystite aigiie. Cependant, la chirurgie d'urgence est associée à une morbidité majeure accrue et l'approche par laparoscopic n'est pas toujours réalisable. Le drainage percutané de la VB est donc une modalité de traitement valable, mais nécessite à distance de l'épisode aigu une cholécystectomie par laparoscopic, surtout après une cholécystite lithiasique.
Resumo:
OBJECTIVE: This study was designed to analyze the duration of chest tube drainage on pain intensity and distribution after cardiac surgery. METHODS: Two groups of 80 cardiac surgery adult patients, operated on in two different hospitals, by the same group of cardiac surgeons, and with similar postoperative strategies, were compared. However, in one hospital (long drainage group), a conservative policy was adopted with the removal the chest tubes by postoperative day (POD) 2 or 3, while in the second hospital (short drainage group), all the drains were usually removed on POD 1. RESULTS: There was a trend toward less pain in the short drainage group, with a statistically significant difference on POD 2 (P=0.047). There were less patients without pain on POD 3 in the long drainage group (P=0. 01). The areas corresponding to the tract of the pleural tube, namely the epigastric area, the left basis of the thorax, and the left shoulder were more often involved in the long drainage group. There were three pneumonias in each group and no patient required repeated drainage. CONCLUSIONS: A policy of early chest drain ablation limits pain sensation and simplifies nursing care, without increasing the need for repeated pleural puncture. Therefore, a policy of short drainage after cardiac surgery should be recommended.
Resumo:
OBJECTIVES: Assess the benefit of temporary caval stenting for remote venous drainage during cardiopulmonary bypass (CPB). METHODS: Temporary caval stenting was realized in bovine experiments (65+/-6 kg) by the means of self-expanding (18F for insertion, 36F in situ) venous cannulas (Smartcanula LLC, Lausanne, Switzerland) with various lengths: 43 cm, 53 cm, 63 cm vs. a standard 28F wire armed cannula in trans-jugular fashion. Maximal blood flows were assessed for 20, 25 and 30 mmHg of driving pressure with a motorized table height adjustment system. In addition, the inferior caval diameters (just above its bifurcation) were measured in real time with intra-vascular ultrasound (IVUS). RESULTS: Venous drainage (flow in l/min) at 20 mmHg, 25 mmHg, and 30 mmHg drainage load was 3.5+/-0.5, 3.7+/-0.7 and 4.0+/-0.6 for the 28F standard vs. 4.1+/-0.7, 4.0+/-1.3 and 3.9+/-1.1 for the 36F smart 43 cm, vs. 5.0+/-0.7, 5.3+/-1.3 and 5.4+/-1.4 for the 36F smart 53 cm, vs. 5.2+/-0.5*, 5.6+/-1.1* and 5.8+/-1.0* for the 36F smart 63 cm. The inferior vena caval diameters at 30 mmHg were 13.5+/-4.8 mm for 28F standard, 11.1+/-3.6 for 36F smart 43 cm, 11.3+/-3.2 for 36F 53 cm, and 17.0+/-0.1* for 36F 63 cm (*P<0.05 for 28F standard vs. 36F smart 63 cm long) CONCLUSIONS: The 43 cm self-expanding 36F smartcanula outperforms the 28F standard wire armed cannula at low drainage pressures and without augmentation. Temporary caval stenting with long self-expanding venous cannulas provides even better drainage (+51%).
Resumo:
PURPOSE: We report on the in vivo testing of a novel noninvasively adjustable glaucoma drainage device (AGDD), which features an adjustable outflow resistance, and assess the safety and efficiency of this implant. METHODS: Under general anesthesia, the AGDD was implanted on seven white New Zealand rabbits for a duration of 4 months under a scleral flap in a way analogous to the Ex-PRESS device and set in an operationally closed position. The IOP was measured on a regular basis on the operated and control eyes using a rebound tonometer. Once a month the AGDD was adjusted noninvasively from its fully closed to its fully open position and the resulting pressure drop was measured. The contralateral eye was not operated and served as control. After euthanization, the eyes were collected for histology evaluation. RESULTS: The mean preoperative IOP was 11.1 ± 2.4 mm Hg. The IOP was significantly lower for the operated eye (6.8 ± 2 mm Hg) compared to the nonoperated eye (13.1 ± 1.6 mm Hg) during the first 8 days after surgery. When opening the AGDD from its fully closed to fully open position, the IOP dropped significantly from 11.2 ± 2.9 to 4.8 ± 0.9 mm Hg (P < 0.05). CONCLUSIONS: Implanting the AGDD is a safe and uncomplicated surgical procedure. The fluidic resistance was noninvasively adjustable during the postoperative period with the AGDD between its fully closed and fully open positions.