390 resultados para PCM Condenser


Relevância:

20.00% 20.00%

Publicador:

Resumo:

La sélection opérée par les rubriques et les enluminures, formes contraintes qui échappent dans une certaine mesure à la linéarité du développement textuel, détermine la réception de l'œuvre. Les manuscrits comprenant des miniatures synthétiques (comme celles qui représentent l'enfance de Merlin) ou des séries iconographiques (comme celles qui rendent compte des amours d'Uterpandragon et Ygerne et de leurs conséquences) présentent donc un caractère exceptionnel, orientant la lecture du texte et son interprétation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper presents the results of a numerical and experimental study of phase change material (PCM) filled walls and roofs under real operational conditions to achieve passive thermal comfort. The numerical part of the study was based on a one-dimensional model for the phase change problem controlled by pure conduction. Real radiation data was used to determine the external face temperature. The numerical treatment was based upon using finite difference approximations and the ADI scheme. The results obtained were compared with field measurements. The experimental set-up consisted of a small room with movable roof and side wall. The roof was constructed in the traditional way but with the phase change material enclosed. Thermocouples were distributed across the cross section of the roof. Another roof, identical but without the PCM, was also used during comparative tests. The movable wall was also constructed as is done traditionally but with the PCM enclosed. Again, thermocouples were distributed across the wall thickness to enable measurement of the local temperatures. Another wall, identical but without the PCM, was also used during comparative tests. The PCM used in the numerical and experimental tests was composed of a mixture of two commercial grades of glycol in order to obtain the required fusion temperature range. Comparison between the simulation results and the experiments indicated good agreement. Field tests also indicated that the PCM used was adequate and that the concept was effective in maintaining the indoor temperature very close to the established comfort limits. Further economical analysis indicated that the concept could effectively help in reducing the electric energy consumption and improving the energy demand pattern. © 1997 by John Wiley & Sons, Ltd.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Grant no. R-800700.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The paper presents the simulation of the pyrolysis vapors condensation process using an Eulerian approach. The condensable volatiles produced by the fast pyrolysis of biomass in a 100 g/h bubbling fluidized bed reactor are condensed in a water cooled condenser. The vapors enter the condenser at 500 °C, and the water temperature is 15 °C. The properties of the vapor phase are calculated according to the mole fraction of its individual compounds. The saturated vapor pressure is calculated for the vapor mixture using a corresponding states correlation and assuming that the mixture of the condensable compounds behave as a pure fluid. Fluent 6.3 has been used as the simulation platform, while the condensation model has been incorporated to the main code using an external user defined function. © 2011 American Chemical Society.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Il presente lavoro di tesi mira a studiare l’utilizzo di aggregati artificiali (PLA) costituiti da aggregati leggeri (LWA) impregnati di materiali a cambiamento di fase (Phase-Change Materials, PCM) nei conglomerati bituminosi. L’obiettivo della tesi è quello di dimostrare che l’utilizzo di questi materiali nelle sovrastrutture stradali, grazie alla proprietà di cambiare fase (da solida a liquida e viceversa) in funzione della temperatura, induce una liberazione di calore. La conseguenza immediata dell’utilizzo di questi materiali è la ridotta necessità di manutenzione invernale, abbattendo i costi di ripristino della pavimentazione. Inoltre l’utilizzo di PLA non deve pregiudicare l’aspetto prestazionale e la vita utile dell’infrastruttura.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this study, I experimentally analyzed the performance of a commercial semi-welded plate type heat exchanger (PHE) for use with ammonia systems. I determined performance parameters such as overall heat transfer coefficient, capacity, and pressure drop of the semi-welded PHE. This was analyzed by varying different parameters which demonstrated changes in overall heat transfer coefficient, capacity, and pressure drop. Both water and ammonia flow rates to the semi-welded PHE were varied independently, and analyzed in order to understand how changes in flow rates affected performance. Inlet water temperature was also varied, in order to understand how raising condenser water inlet temperature would affect performance. Finally, pressure drop was monitored to better understand the performance limitations of the semi-welded PHE. Testing of the semi-welded will give insight as to the performance of the semi-welded PHE in a potential ocean thermal energy conversion system, and whether the semi-welded PHE is a viable choice for use as an ammonia condenser.