999 resultados para PAR attenuation coefficient


Relevância:

90.00% 90.00%

Publicador:

Resumo:

Crystallization kinetics of syndiotactic polypropylene ( sPP) was observed by light attenuation measurements. The initial stages of temperature dependent sPP crystallization fall in the range of Rayleigh scattering and Rayleigh-Debye-Gans scattering. Initial time and growth time of crystallization were obtained, and the trend of crystallization temperature dependent linear attenuation coefficient on the radius and the index of the refraction of the spherulite were evaluated.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Ultraviolet(UV) radiation at four wavelengths (305, 320, 340 and 380 nm) and photosynthetically active radiation (PAR) were measured from May 1994 to October 1999 using Biospherical UV radiometers. A surface reference sensor located on the roof of the Marine Station at Helgoland recorded values every 5 min, and an equivalent profiling underwater sensor was used for measurements in the sea at approximately monthly intervals. The ratio of 305-nm radiation to PAR varied seasonally, with a 14-fold increase from winter to summer. A much weaker seasonal trend (ca. 1.5-fold) was apparent in the ratio of 320-nm radiation to PAR, but there was no seasonal trend in the ratios of 340- or 380-nm radiation to PAR. The year-to-year variations in 305-nm radiation were also much greater relative to PAR than for the other UV wavelengths, but there was no evidence of a change in the 305 nm:PAR ratio over the study period. The ratios of both 305- and 320-nm radiation to PAR increased from dawn to midday, but those of 340- and 380-nm radiation were almost constant through the day, except shortly before sunrise and after sunset when the proportions of 340- and 380-nm radiation increased. Underwater measurements of PAR and UV suggest that the 1% depth for 305-nm radiation was little more than 1 m, but this estimate is valid only for summer and autumn because, in other seasons, few reliable readings for 305-nm radiation could be obtained underwater, and no attenuation coefficient could be calculated. The 1% depths recorded for the other UV wavelengths in the middle 6 months of the year were 2.0 m for 320 nm, 2.6 m for 340 nm and 4.6 m for 380 nm, compared with 12 m for PAR, but the attenuation of all wavebands increased sharply in October and remained higher until March. An analysis of the influence of sun angle, total column ozone concentration, the proportion of skylight, and cloud cover on the ratio of UV wavelengths to PAR in surface irradiance demonstrated that solar angle has a greater influence than ozone concentration on the irradiance at 305 nm, and that the typical occurrence of ozone

Relevância:

90.00% 90.00%

Publicador:

Resumo:

La pratique de l’hématologie, comme celle de toute profession, implique l’acquisition d’un raisonnement adéquat. Se basant sur une théorie de psychologie cognitive, le test de concordance de script (TCS) a été développé et validé comme un instrument permettant d’évaluer le raisonnement clinique dans diverses spécialités médicales. Le but de cette étude était d’examiner l’utilité et les paramètres psychométriques d’un TCS en hématologie. Nous avons construit un TCS composé de 60 questions que nous avons administré à 15 résidents juniors (R1 à R3 en médecine interne), 46 résidents séniors (R4, R5 et R6 en hématologie) et 17 hématologues à travers le Canada. Après optimisation, le TCS comptait 51 questions. Sa consistance interne mesurée par le coefficient de Cronbach alpha était 0.83. Le test était en mesure de discriminer entre les résidents selon leur niveau de formation. Les questions contenant des images (n=10) semblaient avoir un potentiel discriminatoire plus élevé. Les scores obtenus par les résidents séniors corrélaient modéremment avec ceux obtenus à un test conventionnel d’hématologie composé de questions à choix multiples et à courte réponse (r de Pearson = 0.42; p=0.02). Le TCS a été complété en 36 minutes en moyenne et a été bien reçu par les participants. Le TCS est un instrument d’évaluation utile et valide en hématologie. Il peut être utilisé à des fins formatives en aidant au suivi de la progression des résidents. Il pourrait aussi être combiné à d’autres instruments d’évaluation à des fins sanctionnelles, ou encore, en éducation médicale continue.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Small local earthquakes from two aftershock sequences in Porto dos GaA(0)chos, Amazon craton-Brazil, were used to estimate the coda wave attenuation in the frequency band of 1 to 24 Hz. The time-domain coda-decay method of a single backscattering model is employed to estimate frequency dependence of the quality factor (Q (c)) of coda waves modeled usingwhere Q (0) is the coda quality factor at frequency of 1 Hz and eta is the frequency parameter. We also used the independent frequency model approach (Morozov, Geophys J Int, 175:239-252, 2008), based in the temporal attenuation coefficient, chi(f) instead of Q(f), given by the equation for the calculation of the geometrical attenuation (gamma) and effective attenuation Q (c) values have been computed at central frequencies (and band) of 1.5 (1-2), 3.0 (2-4), 6.0 (4-8), 9.0 (6-12), 12 (8-16), and 18 (12-24) Hz for five different datasets selected according to the geotectonic environment as well as the ability to sample shallow or deeper structures, particularly the sediments of the Parecis basin and the crystalline basement of the Amazon craton. For the Parecis basin for the surrounding shield and for the whole region of Porto dos GaA(0)chos Using the independent frequency model, we found: for the cratonic zone, gamma = 0.014 s (-aEuro parts per thousand 1), nu a parts per thousand 1.12; for the basin zone with sediments of similar to 500 m, gamma = 0.031 s (-aEuro parts per thousand 1), nu a parts per thousand 1.27; and for the Parecis basin with sediments of similar to 1,000 m, gamma = 0.047 s (-aEuro parts per thousand 1), nu a parts per thousand 1.42. Analysis of the attenuation factor (Q (c)) for different values of the geometrical spreading parameter (nu) indicated that an increase of nu generally causes an increase in Q (c), both in the basin as well as in the craton. But the differences in the attenuation between different geological environments are maintained for different models of geometrical spreading. It was shown that the energy of coda waves is attenuated more strongly in the sediments, (in the deepest part of the basin), than in the basement, (in the craton). Thus, the coda wave analysis can contribute to studies of geological structures in the upper crust, as the average coda quality factor is dependent on the thickness of sedimentary layer.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

In this work, is presented an alternative and non conventional technique for evaluate the water amount present in the hydrated ethanol used as automotive fuel. The standard technique used in this kind of measure is the use of densimeter. The proposal of this work is based on the measure of the linear attenuation coefficient of hydrated ethanol, using the gamma-ray attenuation technique. The water amount, in volume, can be determined knowing the linear attenuation coefficient of hydrated ethanol. Samples of hydrated ethanol, collected at fuel stations, located in Sorocaba, SP, Brazil, were analyzed and the results showed the feasibility of the technique. © 2011 American Institute of Physics.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

The goal of this study was to test the hypothesis that the aggregated state of natural marine particles constrains the sensitivity of optical beam attenuation to particle size. An instrumented bottom tripod was deployed at the 12-m node of the Martha's Vineyard Coastal Observatory to monitor particle size distributions, particle size-versus-settling-velocity relationships, and the beam attenuation coefficient (c(p)) in the bottom boundary layer in September 2007. An automated in situ filtration system on the tripod collected 24 direct estimates of suspended particulate mass (SPM) during each of five deployments. On a sampling interval of 5 min, data from a Sequoia Scientific LISST 100x Type B were merged with data from a digital floc camera to generate suspended particle volume size distributions spanning diameters from approximately 2 mu m to 4 cm. Diameter-dependent densities were calculated from size-versus-settling-velocity data, allowing conversion of the volume size distributions to mass distributions, which were used to estimate SPM every 5 min. Estimated SPM and measured c(p) from the LISST 100x were linearly correlated throughout the experiment, despite wide variations in particle size. The slope of the line, which is the ratio of c(p) to SPM, was 0.22 g m(-2). Individual estimates of c(p):SPM were between 0.2 and 0.4 g m(-2) for volumetric median particle diameters ranging from 10 to 150 mu m. The wide range of values in c(p):SPM in the literature likely results from three factors capable of producing factor-of-two variability in the ratio: particle size, particle composition, and the finite acceptance angle of commercial beam-transmissometers.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

The cruise with RV Tydeman was devoted to study permanently stratified plankton systems in the (sub)tropical ocean, which are characterised by a deep chlorophyll peak between 80 and 150 m. To minimise lateral effects by horizontal transport of nutrients and organic matter from river outflow and upwelling regions, stations were selected in the middle of the North Atlantic Ocean between the continents of America and Africa. (5 - 35° N and 50 - 15° W). Here the vertical distributions of light and nutrients control the abundance and growth of autotrophic algae in the thermically stratified water column. This phytoplankton is numerically dominated by the prokaryotic picoplankters Synechococcus spp. and Prochlorococcus spp., which are smaller than 2 ?m. The productivity of the 100 to 150 m deep euphotic zone can be high, because a high heterotrophic/autotrophic biomass ratio induces a rapid regeneration of nutrients and inorganic carbon. Primary grazers are mainly micro-organisms such as heterotrophic nannoflagellates and ciliates, which feed on the small algae and on bacteria. Heterotrophic bacteria can outnumber the autotrophic algae, because their number is related to the substrate pools of dissolved and particulate dead organic matter. These DOC and detritus pools reach equilibrium at a concentration, where the rate of their production (proportional to algal biomass) equals their mineralisation and sinking rate (proportional to the concentration and weight of POC and detritus). At a relatively low value of the weight-specific loss rates, the equilibrium concentration of these carbon pools and their load of bacteria can be high. The bacterial productivity is proportional to the mineralisation rate, which in a steady state can never be higher than the rate of primary production. Hence the ratio in turnover rate of bacteria and autotrophs tends to be reciprocally proportional to their biomass ratio.