947 resultados para Orthodontic brackets
Resumo:
The purpose of the present study was to evaluate in vivo the failure rate of metallic brackets bonded with two orthodontic composites. Nineteen patients with ages ranging from 10.5 to 38.7 years needing corrective orthodontic treatment were selected for study. The enamel surfaces from second premolars to second premolars were treated with Transbond Plus-Self Etching Primer (3M Unitek). Next, 380 orthodontic brackets were bonded on maxillary and mandibular teeth, as follows: 190 with Transbond XT composite (3M Unitek) (control) and 190 with Transbond Plus Color Change (3M Unitek) (experimental) in contralateral quadrants. The bonded brackets were light cured for 40 s, and initial alignment archwires were inserted. Bond failure rates were recorded over a six-month period. At the end of the evaluation, six bond failures occurred, three for each composite. Kaplan-Meyer method and log-rank test (Mantel-Cox) was used for statistical analysis, and no statistically significant difference was found between the materials (p=0.999). Both Transbond XT and Transbond Plus Color Change composites had low debonding rates over the study period.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
OBJETIVO: A associação de mesiodens com hábito de sucção digital como fatores etiológicos de diastemas medianos é uma situação clínica incomum e, quando presente, provoca um comprometimento estético e funcional. O objetivo desse trabalho é descrever o caso clínico de um paciente, aos 9 anos de idade, com mordida aberta anterior e um diastema mediano de 9 mm. DESCRIÇÃO do CASO: Após o diagnóstico ortodôntico, a conduta terapêutica foi a exodontia do mesiodens e instalação de uma grade palatina fixa para controle do hábito de sucção digital. em seguida, bráquetes ortodônticos foram colados nos incisivos centrais superiores e o diastema foi fechado possibilitando a irrupção espontânea dos incisivos laterais. Quando adequados níveis de trespasse vertical e horizontal entre os incisivos foi alcançado e o hábito removido, o tratamento foi finalizado. CONCLUSÃO: É importante ressaltar que com o objetivo de alcançar resultados estéticos e funcionais satisfatórios, minimizando sequelas ao desenvolvimento da oclusão deve-se realizar o diagnóstico precoce e intervenção imediata dos diastemas medianos patológicos.
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Objective: This crossover study compared the efficacy of an ultrasonic toothbrush for the reduction of plaque, gingival inflammation, and levels of Streptococcus mutans, in relation to an electric and a manual toothbrush. Materials and Methods: Twenty-one patients with orthodontic appliances were divided into three groups. All patients were evaluated by a periodontist and samples of saliva were collected for quantification of S mutans. The patients received their first brushes with appropriate instructions. For each crossover leg, patients used each toothbrush for a period of 30 days. At the end of each washout period, participants received a periodontal evaluation and new samples of saliva were collected. After 15 days of using their own toothbrushes, patients received the next toothbrushes in the experimental sequence. Results: The ultrasonic brush group presented significant improvement in the reduction of visible plaque on the buccal surfaces (-6.36%, P = .007). The counts of S mutans decreased in the electric (2.04 × 105 to 1.36 × 105 colony-forming units [CFU]/mL) and ultrasonic (2.98 × 105 to 1.84 × 105 CFU/mL) groups. There were no statistical differences among the three brushes for the clinical and microbiological parameters evaluated. Conclusions: This study did not demonstrate that the ultrasonic toothbrush was better in reducing gingival inflammation in adolescent orthodontic patients, but plaque scores were lowered on buccal surfaces of teeth with orthodontic brackets. In addition, S mutans counts were markedly decreased in the electric and ultrasonic groups, which should be related to a reduced risk of oral disease. © 2006 by The EH Angle Education and Research Foundation, Inc.
Resumo:
To assess the occurrence, extension, and severity of gingival margin alterations in a sample of youth after orthodontic treatment. Records from 209 Caucasian adolescents (118 female and 91 male) before and after orthodontic treatment were selected. Patients presented a mean age at the beginning of orthodontic treatment of 11.20 ± 1.86 years and a final mean age of 14.72 ± 1.83 years. Class I and II patients with mandibular incisors and canines that were completely erupted and with spacing or crowding not exceeding 4 mm were evaluated. The presence of gingival recession on the labial surface of the mandibular anterior teeth was evaluated in intraoral photographs and casts made before and after treatment. The proportion of patients with gingival recession after treatment was statistically higher than at the beginning (P<.001). After orthodontic treatment, gingival recession was not present in any of the teeth for 63.6% of the patients; in 29.2% of the patients, recession was present in at least 1 tooth. In terms of severity, the majority of affected teeth (47%) presented gingival recession less than 2 mm and in 2% more than 4 mm. It may be concluded that alterations in the gingival margin, especially gingival recession, occur in patients after orthodontic therapy, but the extent and severity of this finding are low. COPYRIGHT © 2007 BY QUINTESSENCE PUBLISHING CO, INC.
Resumo:
This study aimed to compare in vitro the shear bond strength between metallic brackets (Abzil) with conventional mesh bases and metallic brackets with bases industrially sandblasted with aluminum oxide using three adhesive systems, in order to assess the influence of sandblasting on adhesiveness and to compare 3 different bonding systems. Two hundred and forty bovine incisors were used and randomly divided into 6 groups (40 teeth in each group), according to the bracket base and to the bonding system. The brackets were direct-bonded in bovine teeth with 3 adhesive systems: System A - conventional Transbond™ XT (3M -Unitek); System B - Transbond™ Plus Self Etching Primer + Transbond™ XT (3M - Unitek) and System C - Fuji ORTHO LC resin-reinforced glass ionomer cement in capsules (GC Corp.). Shear bond strength tests were performed 24 hours after bonding, in a DL-3000 universal testing machine (EMIC), using a load cell of 200 kgf and a speed of 1 mm/min. The results were submitted to statistical analysis and showed no significant difference between conventional and sandblasted bracket bases. However, comparison between the bonding systems presented significantly different results. System A (14.92 MPa) and system C (13.24 MPa) presented statistically greater shear bond strength when compared to system B (10.66 MPa). There was no statistically significant difference between system A and system C.
Resumo:
Pós-graduação em Ciências Odontológicas - FOAR
Resumo:
AIM: To evaluate the staining of esthetic orthodontic brackets by plaque disclosing solutions. METHODS: Two types of brackets manufactured by GAC/DENTSPLY(r) were evaluated: ceramic (n=30) and polycarbonate (n=30). The brackets were divided into 6 groups. Two control groups (n=6) were immersed in absolute ethanol: GI - ceramic brackets and GII - polycarbonate brackets. Four experimental groups (n=12) were immersed in different plaque disclosing solutions: GIII (ceramic brackets) and GIV (polycarbonate brackets) were immersed in Replak(r); GV (ceramic brackets) and GVI (polycarbonate brackets) were immersed in Replasul "S"(r). Relative quantitative analysis of the influence of plaque disclosing tablets on bracket staining was performed using reflectance spectrophotometry of stain deposition. Exploratory analysis of the data was performed using Analysis of Variance (ANOVA) in a 2x2 factorial setup (bracket x immersion) with additional treatments (controls). RESULTS: The results demonstrated that the ceramic brackets presented the highest amount of staining when Replasul "S"(r) was used (pd"0.05). However, when Replak(r) was used, no statistically significant difference was found in comparison with the control group (p>0.05). For polycarbonate brackets, staining was detected for both disclosing solutions (p>0.05). CONCLUSIONS: The disclosing solutions caused stain formation on polycarbonate brackets and, under the tested conditions, use of Replak(r) on ceramic brackets did not cause staining.
Resumo:
INTRODUÇÃO: frequentemente, os pacientes ortodônticos apresentam restaurações de resina composta; no entanto, existem poucos estudos que avaliam a melhor forma de colagem ortodôntica nessa situação. OBJETIVO: o objetivo do presente trabalho foi avaliar a força adesiva de braquetes ortodônticos em restaurações resinosas com tratamento de superfície. MÉTODOS: foram utilizados 51 incisivos inferiores bovinos divididos aleatoriamente em três grupos. No grupo controle (GC), os braquetes foram colados em esmalte dentário; nos grupos experimentais com tratamento (GCT) e sem tratamento (GST), os braquetes foram colados em restauração de resina previamente realizada, diferenciando-se pelo tratamento de superfície com broca diamantada. Os dentes foram incluídos em tubos de PVC com resina acrílica autopolimerizável. O ensaio de cisalhamento foi executado em máquina universal de ensaios Emic. Os grupos foram submetidos à ANOVA com pós-teste de Tukey para verificação da diferença estatística entre os grupos (α = 0,05). RESULTADOS: GC (6,62MPa) e GCT (6,82MPa) apresentaram resultados semelhantes, enquanto o GST (5,07MPa) obteve resultados estatisticamente menores (p < 0,05). CONCLUSÃO: conclui-se que a melhor técnica de colagem de braquetes ortodônticos em restaurações de resina composta é a de realização de desgaste sobre a superfície.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
OBJECTIVE: The purpose of this study was to assess by means of scanning electron microscopy (SEM) the remaining adhesive interface after debonding orthodontic attachments bonded to bovine teeth with the use of hydrophilic and hydrophobic primers under different dental substrate moisture conditions. MATERIAL AND METHODS: Twenty mandibular incisors were divided into four groups (n=5). In Group I, bracket bonding was performed with Transbond MIP hydrophilic primer and Transbond XT adhesive paste applied to moist substrate, and in Group II a bonding system comprising Transbond XT hydrophobic primer and adhesive paste was applied to moist substrate. Brackets were bonded to the specimens in Groups III and IV using the same adhesive systems, but on dry dental enamel. The images were qualitatively assessed by SEM. RESULTS: The absence of moisture in etched enamel enabled better interaction between bonding materials and the adamantine structure. The hydrophobic primer achieved the worst micromechanical interlocking results when applied to a moist dental structure, whereas the hydrophilic system proved versatile, yielding acceptable results in moist conditions and excellent interaction in the absence of contamination. CONCLUSION: The authors assert that the best condition for the application of primers to dental enamel occurs in the absence of moisture.
Resumo:
Manufacturers offer various prescriptions of preadjusted brackets for use in the "straight-wire" orthodontic technique. However, the need to incorporate bends in the rectangular wires during orthodontic finishing has led to concerns regarding the type of prescription chosen and the credibility of information provided by the manufacturer. The aim of this study was to compare the slot angulations of Roth prescription preadjusted metallic brackets for the maxillary left central incisor and maxillary left canine. For each tooth type, 10 brackets of three commercial brands (GAC, Forestadent and Morelli) were selected. Two individual metal matrices for brackets and tooth positioning were made for each group of teeth. Captured images were obtained by standardized ortho-radial photography with a digital camera. Images were exported and analyzed with the Image J software package. One-way ANOVA and Tukey statistical analyses were performed at the 5% significance level. For brackets of the maxillary left central incisor, differences in mean angulation were observed between the Morelli and GAC groups (p < 0.01) and between the Forestadent and GAC groups (p < 0.01). For brackets of the maxillary left canine, differences in mean angulation were found between the Morelli and GAC groups (p < 0.01) and between the Morelli and Forestadent groups (p < 0.05). In conclusion, despite their same prescription name, the different brands exhibited significantly different angulation measurements.