991 resultados para Optical resolving power
Resumo:
The world's deep oceans are home to a number of teleosts with asymmetrical or tubular eyes. These immobile eyes possess large spherical lenses and subtend a large binocular visual field directed either dorsally or rostrally. Derived from a lateral non-tubular eye, the tubular eye is comprised of a thick main retina, subserving the rostrally or dorsally directed binocular visual field, and a thin accessory retina subserving, the lateral, monocular visual field. The main retina is thought to receive a focussed image, while the accessory retina is too close to the lens for a focussed image to be received. Several species also possess retinal diverticula, which are small evaginations of differentiated retina located in the rostrolateral wall of the eye and thought to increase the visual field. In order to investigate the spatial resolving power of these retinae (main, accessory and diverticulum), the distribution of cells within the ganglion cell layer was analysed from retinal wholemounts and sectioned material in ten species representing four genera. In all species, the main retina possesses a marked increase in cell density towards a specialised retinal region (area centralis), with a centro-peripheral gradient range between 7.1 and 60:1 and a peak density range of between 30 and 55 x 10(3) cells per mm(2). The accessory retinae and the transitional zone between the main and accessory retinae possess relatively low cell densities (between 1 and 10 x 10(3) cells per mm(2)) and lack an area centralis. Retinal diverticula examined in four species possess mean ganglion cell densities of between 7.2 and 109.4 x 10(3) cells per mm(2). Analyses of soma areas show that the ganglion cell layer of most species possesses cells with areas in a range of 8.0 to 15.4 mu m(2) in the main retina and between 15.1 and 17.4 mu m(2) in the accessory retina. The peak spatial resolving power of the main retina of the ten species varies from 4.1 to 9.1 cycles per degree. The positions of the retinal areae centrales relative to each species' binocular visual field are discussed in relation to what is known of feeding behaviour of these fishes in the deep-sea.
Resumo:
In this study we have demonstrated the potential of two-dimensional electrophoresis (2DE)-based technologies as tools for characterization of the Leishmania proteome (the expressed protein complement of the genome). Standardized neutral range (pH 5-7) proteome maps of Leishmania (Viannia) guyanensis and Leishmania (Viannia) panamensis promastigotes were reproducibly generated by 2DE of soluble parasite extracts, which were prepared using lysis buffer containing urea and nonidet P-40 detergent. The Coomassie blue and silver nitrate staining systems both yielded good resolution and representation of protein spots, enabling the detection of approximately 800 and 1,500 distinct proteins, respectively. Several reference protein spots common to the proteomes of all parasite species/strains studied were isolated and identified by peptide mass spectrometry (LC-ES-MS/MS), and bioinformatics approaches as members of the heat shock protein family, ribosomal protein S12, kinetoplast membrane protein 11 and a hypothetical Leishmania-specific 13 kDa protein of unknown function. Immunoblotting of Leishmania protein maps using a monoclonal antibody resulted in the specific detection of the 81.4 kDa and 77.5 kDa subunits of paraflagellar rod proteins 1 and 2, respectively. Moreover, differences in protein expression profiles between distinct parasite clones were reproducibly detected through comparative proteome analyses of paired maps using image analysis software. These data illustrate the resolving power of 2DE-based proteome analysis. The production and basic characterization of good quality Leishmania proteome maps provides an essential first step towards comparative protein expression studies aimed at identifying the molecular determinants of parasite drug resistance and virulence, as well as discovering new drug and vaccine targets.
Resumo:
Anti-doping authorities have high expectations of the athlete steroidal passport (ASP) for anabolic-androgenic steroids misuse detection. However, it is still limited to the monitoring of known well-established compounds and might greatly benefit from the discovery of new relevant biomarkers candidates. In this context, steroidomics opens the way to the untargeted simultaneous evaluation of a high number of compounds. Analytical platforms associating the performance of ultra-high pressure liquid chromatography (UHPLC) and the high mass-resolving power of quadrupole time-of-flight (QTOF) mass spectrometers are particularly adapted for such purpose. An untargeted steroidomic approach was proposed to analyse urine samples from a clinical trial for the discovery of relevant biomarkers of testosterone undecanoate oral intake. Automatic peak detection was performed and a filter of reference steroid metabolites mass-to-charge ratio (m/z) values was applied to the raw data to ensure the selection of a subset of steroid-related features. Chemometric tools were applied for the filtering and the analysis of UHPLC-QTOF-MS(E) data. Time kinetics could be assessed with N-way projections to latent structures discriminant analysis (N-PLS-DA) and a detection window was confirmed. Orthogonal projections to latent structures discriminant analysis (O-PLS-DA) classification models were evaluated in a second step to assess the predictive power of both known metabolites and unknown compounds. A shared and unique structure plot (SUS-plot) analysis was performed to select the most promising unknown candidates and receiver operating characteristic (ROC) curves were computed to assess specificity criteria applied in routine doping control. This approach underlined the pertinence to monitor both glucuronide and sulphate steroid conjugates and include them in the athletes passport, while promising biomarkers were also highlighted.
Resumo:
Capillary electrophoresis (CE) encompasses a number of characteristics quite suitable for the simultaneous analysis of small ions such as high efficiency and resolving power, directly associated to its impressively high peak capacity, and short analysis time. In appropriate conditions, it is possible to perform the separation of approximately 36 anions in less than 3 minutes. In this work, the mechanisms by which anion analysis is performed was criteriously discussed, and a thorough review of the literature in the past 5 years, focusing mostly in applications of CE to anion analysis in real matrices, was presented.
Resumo:
Brazilian biodiversity is a colossal source of secondary metabolites with remarkable structural features, which are valuable in further biodiscovery studies. In order to fully understand the relations and interactions of a living system with its surroundings, efforts in natural product chemistry are directed toward the challenge of detecting and identifying all the molecular components present in complex samples. It is plausible that this endeavor was born out of recent technological sophistication in secondary metabolite identification with sensitive spectroscopic instruments (MS and NMR) and higher resolving power of chromatographic systems, which allow a decrease in the amount of required sample and time to acquire data. Nevertheless, the escalation of data acquired in these analyses must be sorted with statistical and multi-way tools in order to select key information. Chromatography is also of paramount importance, more so when selected compounds need to be isolated for further investigation. However, in the course of pursuing a "greener" environment, new policies, with an aim to decrease the use of energy and solvents, are being developed and incorporated into analytical methods. Metabolomics could be an effective tool to answer questions on how living organisms in our huge biodiversity work and interact with their surroundings while also being strategic to the development of high value bio-derived products, such as phytotherapeutics and nutraceuticals. The incorporation of proper phytotherapeutics in the so-called Brazilian Unified Health System is considered an important factor for the urgent improvement and expansion of the Brazilian national health system. Furthermore, this approach could have a positive impact on the international interest toward scientific research developed in Brazil as well as the development of high value bio-derived products, which appear as an interesting economic opportunity in national and global markets. Thus, this study attempts to highlight the recent advances in analytical tools used in detection of secondary metabolites, which can be useful as bioproducts. It also emphasizes the potential avenues to be explored in Brazilian biodiversity, known for its rich chemical diversity.
Resumo:
The constant evolution of science and the growing demand for new technologies have led to new techniques in instrumentation that can improve detection, separation, resolution, and peak capacity. Comprehensive two-dimensional liquid chromatography (LC×LC) is presented as a powerful tool in complex sample analyses. During an analysis, a sample is subjected to two independent separation mechanisms that are combined, resulting in increased resolving power. For appropriate application of LC×LC, understanding the influence of parameters that require optimization is necessary. The main purpose of optimization is to predict the combination of stationary phases, separation conditions, and instrumental requirements to obtain the best separation performance. This review discusses theoretical, intrumental, and chemometric aspects of LC×LC and focuses on its applications in foods. It aims to provide a clear understanding of the aspects that can be used as strategies in the optimization of this analytical method.
Resumo:
In order to evaluate the resolving power of several typing methods to identify relatedness among Brazilian strains of Enterobacter cloacae, we selected twenty isolates from different patients on three wards of a University Hospital (Orthopedics, Nephrology, and Hematology). Traditional phenotyping methods applied to isolates included biotyping, antibiotic sensitivity, phage-typing, and O-serotyping. Plasmid profile analysis, ribotyping, and macrorestriction analysis by pulsed-field gel electrophoresis (PFGE) were used as genotyping methods. Sero- and phage-typing were not useful since the majority of isolates could not be subtyped by these methods. Biotyping, antibiogram and plasmid profile permitted us to classify the samples into different groups depending on the method used, and consequently were not reliable. Ribotyping and PFGE were significantly correlated with the clinical epidemiological analysis. PFGE did not type strains containing nonspecific DNase. Ribotyping was the most discriminative method for typing Brazilian isolates of E. cloacae.
Resumo:
Réalisé en codirection avec Karen C. Waldron et Dominic Rochefort.
Resumo:
Rotational structure has been resolved and analyzed in the 1049-cm−1 parallel fundamental and the 1182 cm−1 perpendicular fundamental bands in the infrared spectrum of the CH3F molecule. Combination bands at 2223 cm−1 and around 2650 cm−1 have also been studied. The effective resolving power of the spectrometer was 0.25 cm−1 for all these bands. The two long-wavelength fundamentals have been analyzed in much greater detail than in previous work, and a complete analysis of the perpendicular band has been made, including the J-structure in the P and R branches of the sub-bands. Rotational constants of CH3F determined in this work and elsewhere are summarized in Table XIII of the text. Some anomalous intensity perturbations in the rotation lines of the 1182-cm−1 fundamental have been observed, and are discussed.
Resumo:
Some absorption bands of diazomethane vapour between 1950-3500 cm-1 have been measured with very high resolving power. The rotational structure of two parallel bands and of one perpendicular band has been resolved, and approximate values have been determined for the rotational constants. The results are consistent with the geometrical structure usually accepted for this molecule. A peculiarity in the results for the band near 2100 cm-1, together with other facts, leads to the suggestion that a tautomeric form of this molecule exists, HCN=NH, being an isoelectronic analogue of hydrazoic acid.
Resumo:
The fundamental vibration-rotational absorption band of hydrogen chloride near 3 45,t has been remeasured using higher resolving power than previously. The wave-lengths of the absorption lines have been determined more precisely, and the isotopic splitting of lines has been completely resolved. The results have provided new and more satisfactory values for the rotational constants Bi, and the centrifugal stretching constants Di, and their relative values for the two isotopic species agree closely with what is to be expected for the difference in mass. The positions of the lines in the pure rotational absorption spectrum have been calculated from the derived data, and agree closely with those recently observed. The bond lengths re for each isotopic species H35C1 and H37C1 is found to be 1-2744A.
Resumo:
The vibrational spectrum of dimethyl acetylene has been remeasured with better resolving power than hitherto, and the rotational fine structure of some perpendicular type bands has been partly analyzed. The energy levels of a molecule of this kind in which internal rotation of methyl groups may arise have been re-examined theoretically and the rotational structure of the absorption bands has been more clearly defined than previously. The experimental results are consistent with the assumption of unrestricted internal rotation of the methyl groups, and the Coriolis factors $\zeta _{i}$ for several vibrations have been determined.
Resumo:
Rotation lines in the fundamental vibration bands of 13C16O and 12C180 have been measured, using very high resolving power and more accurate wavelength calibrations than previously. The molecular rotational and vibrational constants have been deduced and compared in relation to the mass differences between these molecules and the main species 12C160.
Resumo:
Liquid chromatography-mass spectrometry (LC-MS) datasets can be compared or combined following chromatographic alignment. Here we describe a simple solution to the specific problem of aligning one LC-MS dataset and one LC-MS/MS dataset, acquired on separate instruments from an enzymatic digest of a protein mixture, using feature extraction and a genetic algorithm. First, the LC-MS dataset is searched within a few ppm of the calculated theoretical masses of peptides confidently identified by LC-MS/MS. A piecewise linear function is then fitted to these matched peptides using a genetic algorithm with a fitness function that is insensitive to incorrect matches but sufficiently flexible to adapt to the discrete shifts common when comparing LC datasets. We demonstrate the utility of this method by aligning ion trap LC-MS/MS data with accurate LC-MS data from an FTICR mass spectrometer and show how hybrid datasets can improve peptide and protein identification by combining the speed of the ion trap with the mass accuracy of the FTICR, similar to using a hybrid ion trap-FTICR instrument. We also show that the high resolving power of FTICR can improve precision and linear dynamic range in quantitative proteomics. The alignment software, msalign, is freely available as open source.
Resumo:
There are several advantages of using metabolic labeling in quantitative proteomics. The early pooling of samples compared to post-labeling methods eliminates errors from different sample processing, protein extraction and enzymatic digestion. Metabolic labeling is also highly efficient and relatively inexpensive compared to commercial labeling reagents. However, methods for multiplexed quantitation in the MS-domain (or ‘non-isobaric’ methods), suffer from signal dilution at higher degrees of multiplexing, as the MS/MS signal for peptide identification is lower given the same amount of peptide loaded onto the column or injected into the mass spectrometer. This may partly be overcome by mixing the samples at non-uniform ratios, for instance by increasing the fraction of unlabeled proteins. We have developed an algorithm for arbitrary degrees of nonisobaric multiplexing for relative protein abundance measurements. We have used metabolic labeling with different levels of 15N, but the algorithm is in principle applicable to any isotope or combination of isotopes. Ion trap mass spectrometers are fast and suitable for LC-MS/MS and peptide identification. However, they cannot resolve overlapping isotopic envelopes from different peptides, which makes them less suitable for MS-based quantitation. Fourier-transform ion cyclotron resonance (FTICR) mass spectrometry is less suitable for LC-MS/MS, but provides the resolving power required to resolve overlapping isotopic envelopes. We therefore combined ion trap LC-MS/MS for peptide identification with FTICR LC-MS for quantitation using chromatographic alignment. We applied the method in a heat shock study in a plant model system (A. thaliana) and compared the results with gene expression data from similar experiments in literature.