932 resultados para Optical monitoring


Relevância:

40.00% 40.00%

Publicador:

Resumo:

The paper describes the use of optical fiber Brillouin Optical Time Domain Reflectometry (BOTDR) to monitor the strain distribution in an existing tunnel while a twin tunnel was bored at close-proximity. The twin circular bored tunnels between Serangoon and Bartley stations on the new Circle Line Stage 3 subway in Singapore were constructed at close-proximity to avoid underpinning the foundations of adjacent buildings. The minimum clear separation of the two tunnels is 2.3m (0.4 times the tunnel diameter). The Outer Tunnel was constructed first, followed by the Inner Tunnel, with the earth-pressure balance tunnel boring machines maintained at a minimum of 100m apart. In this trial application of BOTDR, the strain distribution along the Outer Tunnel was measured, in order to monitor its deformation due to the boring of the Inner Tunnel at close-proximity. The aim of the trial application was to determine the practicality of this monitoring method for future use in 'live' tunnels. This paper compares the measurements obtained from optical fiber BOTDR with conventional methods of tunnel monitoring and describes preliminary installation and workmanship guidelines derived from lessons learnt during this trial. © 2007 ASCE.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

The development of a reflective, gold-coated long-period grating-based sensor for the measurement of chloride ions in solution is discussed. The sensor scheme is based around a long-period fiber grating (LPG)-based Michelson interferometer where the sensor was calibrated and evaluated in the laboratory using sodium chloride solutions, over a wide range of concentrations, from 0.01 to 4.00 M. The grating response creates shifts in the spectral characteristic of the interferometer, formed using the LPG and a reflective surface on the distal end of the fiber, due to the change of refracting index of the solution surrounding it. It was found that the sensitivity of the device could be enhanced over that obtained from a bare fiber by coating the LPG-based interferometer with gold nanoparticles and the results of a cross-comparison of performance were obtained and details discussed. The approach will be explored as a basis to create a portable, low-power device, developed with the potential for installation in concrete structures to determine the ingress of chloride ions, operating through monitoring the refractive index change.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

A distributed optical fiber sensor based on Brillouin scattering (BOTDR or BOTDA) can measure and monitor strain and temperature generated along optical fiber. Because it can measure in real-time with high precision and stability, it is quite suitable for health monitoring of large-scale civil infrastructures. However, the main challenge of applying it to structural health monitoring is to ensure it is robust and can be repaired by adopting a suitable embedding method. In this paper, a novel method based on air-blowing and vacuum grouting techniques for embedding long-distance optical fiber sensors was developed. This method had no interference with normal concrete construction during its installation, and it could easily replace the long-distance embedded optical fiber sensor (LEOFS). Two stages of static loading tests were applied to investigate the performance of the LEOFS. The precision and the repeatability of the LEOFS were studied through an overloading test. The durability and the stability of the LEOFS were confirmed by a corrosion test. The strains of the LEOFS were used to evaluate the reinforcing effect of carbon fiber reinforced polymer and thereby the health state of the beams.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

This paper presents the design and implementation of a novel optical fiber temperature compensated relative humidity (RH) sensor device, based on fiber Bragg gratings (FBGs) and developed specifically for monitoring water ingress leading to the deterioration of building stone. The performance of the sensor thus created, together with that of conventional sensors, was first assessed in the laboratory where they were characterized under experimental conditions of controlled wetting and drying cycles of limestone blocks, before being employed “in-the-field” to monitor actual building stone in a specially built wall. Although a new construction, this was built specifically using conservation methods similar to those employed in past centuries, to allow an accurate simulation of processes occurring with wetting and drying in the historic walls in the University of Oxford.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Topic

To compare the accuracy of optical coherence tomography (OCT) with alternative tests for monitoring neovascular age-related macular degeneration (nAMD) and detecting disease activity among eyes previously treated for this condition.

Clinical Relevance

Traditionally, fundus fluorescein angiography (FFA) has been considered the reference standard to detect nAMD activity, but FFA is costly and invasive. Replacement of FFA by OCT can be justified if there is a substantial agreement between tests.

Methods

Systematic review and meta-analysis. The index test was OCT. The comparator tests were visual acuity, clinical evaluation (slit lamp), Amsler chart, color fundus photographs, infrared reflectance, red-free images and blue reflectance, fundus autofluorescence imaging, indocyanine green angiography (ICGA), preferential hyperacuity perimetry, and microperimetry. We searched the following databases: MEDLINE, MEDLINE In-Process, EMBASE, Biosis, Science Citation Index, the Cochrane Library, Database of Abstracts of Reviews of Effects, MEDION, and the Health Technology Assessment database. The last literature search was conducted in March 2013. We used the Quality Assessment of Diagnostic Accuracy Studies 2 (QUADAS-2) to assess risk of bias.

Results

We included 8 studies involving more than 400 participants. Seven reported the performance of OCT (3 time-domain [TD] OCT, 3 spectral-domain [SD] OCT, 1 both types) and 1 reported the performance of ICGA in the detection of nAMD activity. We did not find studies directly comparing tests in the same population. The pooled sensitivity and specificity of TD OCT and SD OCT for detecting active nAMD was 85% (95% confidence interval [CI], 72%–93%) and 48% (95% CI, 30%–67%), respectively. One study reported ICGA with sensitivity of 75.9% and specificity of 88.0% for the detection of active nAMD. Half of the studies were considered to have a high risk of bias.

Conclusions

There is substantial disagreement between OCT and FFA findings in detecting active disease in patients with nAMD who are being monitored. Both methods may be needed to monitor patients comprehensively with nAMD.