949 resultados para Ontoloy capture


Relevância:

20.00% 20.00%

Publicador:

Resumo:

CO2 capture from gaseous effluents is one of the great challenges faced by chemical and environmental engineers, as the increase in CO2 levels in the Earth atmosphere might be responsible for dramatic climate changes. From the existing capture technologies, the only proven and mature technology is chemical absorption using aqueous amine solutions. However, bearing in mind that this process is somewhat expensive, it is important to choose the most efficient and, at the same time, the least expensive solvents. For this purpose, a pilot test facility was assembled and includes an absorption column, as well as a stripping column, a heat exchanger between the two columns, a reboiler for the stripping column, pumping systems, surge tanks and all necessary instrumentation and control systems. Some different aquous amine solutions were tested on this facility and it was found that, from a set of six tested amines, diethanol amine is the one that turned out to be the most economical choice, as it showed a higher CO2 loading capacity (0.982 mol of CO2 per mol of amine) and the lowest price per litre (25.70 ¤/L), even when compared with monoethanolamine, the benchmark solvent, exhibiting a price per litre of 30.50 ¤/L.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Motor dysfunction is consistently reported but understudied in schizophrenia. It has been hypothesized that this abnormality may reflect a neuro-developmental disorder underlying this illness. The main goal of this study was to analyze movement patterns used by participants with schizophrenia and healthy controls during overarm throwing performance, using a markerless motion capture system. Thirteen schizophrenia patients and 16 healthy control patients performed the overarm throwing task in a markerless motion capture system. Participants were also examined for the presence of motor neurological soft signs (mNSS) using the Brief Motor Scale. Schizophrenia patients demonstrated a less developed movement pattern with low individualization of components compared to healthy controls. The schizophrenia group also displayed a higher incidence of mNSS. The presence of a less mature movement pattern can be an indicator of neuro-immaturity and a marker for atypical neurological development in schizophrenia. Our findings support the understanding of motor dysfunction as an intrinsic part of the disorder of schizophrenia.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A sensitive and specific Capture Sandwich ELISA (CSE) was developed using polyclonal purified rabbit antibodies against three different axenic strains of Entamoeba histolytica: CSP from Brazil and HM1 - IMSS from Mexico, for the detection of coproantigens in fecal samples. Immunoglobulin G (IgG) againstis E. histolytica was isolated from rabbits immunized with throphozoites whole extract in two stages: affinity chromatography in a column containing E. histolytica antigens bound to Sepharose 4B was followed by another chromatography in Sepharose antibodies 4B-Protein A. A Capture Sandwich ELISA using purified antibodies was able to detect 70ng of amebae protein, showing a sensitivity of 93% and specificity of 94%. The combination of microscopic examination and CSE gave a concordance and discordance of 93.25% and 6.75%, respectively. It was concluded that CSE is highly specific for the detection of coproantigens of E. histolytica in feces of infected patients, is quicker to perform, easier and more sensitive than microscopic examination.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Amebiasis continues to be of epidemiological importance in underdeveloped countries. Clinical diagnosis and epidemiological setting in a region are based on the fecal microscopic identification of cysts or trophozoites. This procedure requires well trained personnel, is laborious, of low sensitivity and frequently yields false-positives results. The present study was designed to develop an immuno-enzymatic fecal 96 kDa antigen capture test (COPROELISA-Eh) more sensitive and specific than microscopic diagnosis of amebiasis. Triplicates of 177 stool samples processed by the formol-ether concentration method, were defined as positive or negative by three experienced microscopic observers. Another aliquot was submitted to the antigen capture test by a monoclonal antibody against a specific membrane antigen of pathogenic strains of Entamoeba histolytica. Optical densities were interpreted as positive when they exceeded the mean value of negative samples plus two standard deviations. COPROELISA-Eh showed a 94.4% sensitivity, 98.3% specificity, 96.2% positive predictive value and 97.6% negative predictive value for the detection of E. histolytica in feces. COPROELISA-Eh is more sensitive and specific than microscopic examination, does not require specially trained personnel and allows the simultaneous processing of a large number of samples.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The geographical distribution and intra-domiciliary capture of sylvatic triatomines in three districts of the province of La Convención, Cusco, Peru are presented. In the district of Vilcabamba, eight adults of Rhodnius pictipes and five adults of Panstrongylus geniculatus were found. In the district of Ocobamba, 19 adults, 14 nymphs, and eggs of P. rufotuberculatus were found. In the district of Echarate, six adults and 10 nymphs of Eratyrus mucronatus, an adult of R. pictipes and P. geniculatus, and a nymph of P. rufotuberculatus were also found. The geographical distribution of E. mucronatus has extended to Cusco. This is the first report in Peru of household colonization by this triatomine.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: The Genous™ stent (GS) is designed to accelerate endothelization, which is potentially useful in the pro-thrombotic environment of ST-elevation acute myocardial infarction (STEMI). We aimed to evaluate the safety and effectiveness of the GS in the first year following primary percutaneous coronary intervention (PCI) and to compare our results with the few previously published studies. METHODS AND MATERIALS: All patients admitted to a single center due to STEMI that underwent primary PCI using exclusively GS, between May 2006 and January 2012, were enrolled. The primary study endpoints were major adverse cardiac events (MACEs), defined as the composite of cardiac death, acute myocardial infarction and target vessel revascularization, at one and 12months. RESULTS: In the cohort of 109 patients (73.4% male, 59 ±12years), 24.8% were diabetic. PCI was performed in 116 lesions with angiographic success in 99.1%, using 148 GS with median diameter of 3.00mm (2.50-4.00) and median length of 15mm (9-33). Cumulative MACEs were 2.8% at one month and 6.4% at 12months. Three stent thromboses (2.8%), all subacute, and one stent restenosis (0.9%) occurred. These accounted for the four target vessel revascularizations (3.7%). At 12months, 33.9% of patients were not on dual antiplatelet therapy. CONCLUSIONS: GS was safe and effective in the first year following primary PCI in STEMI, with an apparently safer profile comparing with the previously published data. SUMMARY: We report the safety and effectiveness of the Genous™ stent (GS) in the first year following primary percutaneous coronary intervention in ST-elevation acute myocardial infarction. A comprehensive review of the few studies that have been published on this subject was included and some suggest a less safe profile of the GS. Our results and the critical review included may add information and reinforce the safety and effectiveness of the GS in ST-elevation in acute myocardial infarction.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

AIMS: To evaluate the long-term clinical outcomes following percutaneous coronary intervention (PCI) with the Genous stent in an unselected population. METHODS: All patients admitted to a single center who underwent PCI using the GS exclusively, between May 2006 and May 2012, were enrolled, and a clinical follow-up of up to 60 months was carried out. The primary endpoint of major adverse cardiac event (MACE) rate was defined as the composite of cardiac death, acute myocardial infarction (AMI), and target lesion revascularization (TLR). RESULTS: Of the 450 patients included (75.1% male; 65.5 ± 11.7 years), 28.4% were diabetic and acute coronary syndrome was the reason for PCI in 76.4%. Angioplasty was performed in 524 lesions using 597 Genous stents, with angiographic success in 97.1%. At a median of 36 months of follow-up (range, 1-75 months), MACE, AMI, TLR, stent restenosis (SR), and stent thrombosis (ST) rates were 15.6%, 8.4%, 4.4%, 3.8%, and 2.2%, respectively. Between 12 and 24 months, the TLR, SR, and ST rates practically stabilized, up to 60 months. Bifurcation lesions were independently associated with MACE, TLR, and SR. CONCLUSION: This is the first study reporting clinical results with the Genous stent up to 60 months. The Genous stent was safe and effective in the long-term, in an unselected population.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A Work Project, presented as part of the requirements for the Award of a Masters Degree in Management from the NOVA – School of Business and Economics

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Dissertação para obtenção do grau de Mestre em Engenharia Química e Bioquímica

Relevância:

20.00% 20.00%

Publicador:

Resumo:

INTRODUCTION: The present study compares human landing catches of primary malaria vectors with two alternative methods of capture: the Shannon trap and the Mosquito magnet. METHODS: This study used regression models to adjust capture data to a negative binominal distribution. RESULTS: Capture numbers and relative percentages obtained from the three methods vary strongly between species. The highest overall captures were obtained for Anopheles triannulatus with captures for the Shannon trap and the Mosquito magnet measuring more than 330% higher than captures obtained by human landings. For Anopheles darlingi, captures by the Shannon trap and the Mosquito magnet were about 14% and 26% of human landing catches, respectively. Another species with malaria transmission potential that was not sampled by human landing captures weascaptured by the Shannon trap and the Mosquito magnet (Anopheles oswaldoi). Both alternative sampling techniques can predict the human landing of Anopheles triannulatus, but without proportionality. Models for Anopheles darlingi counts, after totaling daily captures, are significant and proportional, but prediction models are more reliable when using the Shannon trap compared with the Mosquito magnet captures. CONCLUSIONS: These alternative capture methods can be partially recommended for the substitution of human landing captures or, at least, as complementary forms of monitoring for malarial mosquitoes.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

INTRODUCTION: Triatomine bug captures in the wild are laborious and time-consuming. Some traps may assist in this task. We report a new trap design and the capture of a specimen of a triatomine rarely found. METHODS: Two luminous traps were installed in the city of Diamantina, State of Minas Gerais, and surveyed weekly for a year. RESULTS: A Triatoma arthurneivai female and other triatomine bugs were caught. CONCLUSIONS: A new trap design may be used in triatomine bugs field captures, mainly in low density areas. We assume the center of endemism of Triatoma arthurneivai is the Espinhaço Mountain range.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Introduction This study evaluated the level of concordance between hybrid capture II (HCII) and PapilloCheck® for the detection of high-risk human papillomavirus (HPV) in anal samples. Methods Anal cell samples collected from 42 human immunodeficiency virus (HIV)+ patients were analyzed. Results Considering only the 13 high-risk HPV types that are detectable by both tests, HCII was positive for 52.3% of the samples, and PapilloCheck® was positive for 52.3%. The level of concordance was 80.9% (Kappa = 0.61). Conclusions Good concordance was observed between the tests for the detection of high-risk HPV.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The suitability of a total-length-based, minimum capture-size and different protection regimes was investigated for the gooseneck barnacle Pollicipes pollicipes shellfishery in N Spain. For this analysis, individuals that were collected from 10 sites under different fishery protection regimes (permanently open, seasonally closed, and permanently closed) were used. First, we applied a non-parametric regression model to explore the relationship between the capitulum Rostro-Tergum (RT) size and the Total Length (TL). Important heteroskedastic disturbances were detected for this relationship, demon- strating a high variability of TL with respect to RT. This result substantiates the unsuitability of a TL-based minimum size by means of a mathematical model. Due to these disturbances, an alternative growth- based minimum capture size of 26.3 mm RT (23 mm RC) was estimated using the first derivative of a Kernel-based non-parametric regression model for the relationship between RT and dry weight. For this purpose, data from the permanently protected area were used to avoid bias due to the fishery. Second, the size-frequency distribution similarity was computed using a MDS analysis for the studied sites to evaluate the effectiveness of the protection regimes. The results of this analysis indicated a positive effect of the permanent protection, while the effect of the seasonal closure was not detected. This result needs to be interpreted with caution because the current harvesting based on a potentially unsuitable mini- mum capture size may dampen the efficacy of the seasonal protection regime.