939 resultados para Nerve Compression Syndromes


Relevância:

80.00% 80.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The authors studied the possible inductive effect of exogenous gangliosides administrated intra-peritoneal and intra-muscular, in 33 rats, after compression and sutures of sciatic nerve. In the animals suffering compression of the sciatic nerve only, the myelin sheath was preserved with good regeneration of the nerve. There was no statistics difference between the two groups with or without the administration of gangliosides. In the group of rats where section of the sciatic nerve and suture were performed, neuroma of amputation as well as dense cicatricial tissue with inflammatory reaction of foreign body type was noted around the sutures. In conclusion, the formation of neuroma of amputation associated with severe inflammatory reaction had an important role in determining the regeneration of the nerve.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Pós-graduação em Ciência Animal - FMVA

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Pós-graduação em Engenharia Mecânica - FEG

Relevância:

80.00% 80.00%

Publicador:

Resumo:

OBJECTIVE: To evaluate the ability of orbital apex crowding volume measurements calculated with multidetector-computed tomography to detect dysthyroid optic neuropathy. METHODS: Ninety-three patients with Graves' orbitopathy were studied prospectively. All of the patients underwent a complete neuro-ophthalmic examination and computed tomography scanning. Volumetric measurements were calculated from axial and coronal contiguous sections using a dedicated workstation. Orbital fat and muscle volume were estimated on the basis of their attenuation values (in Hounsfield units) using measurements from the anterior orbital rim to the optic foramen. Two indexes of orbital muscle crowding were calculated: i) the volumetric crowding index, which is the ratio between soft tissue (mainly extraocular muscles) and orbital fat volume and is based on axial scans of the entire orbit; and ii) the volumetric orbital apex crowding index, which is the ratio between the extraocular muscles and orbital fat volume and is based on coronal scans of the orbital apex. Two groups of orbits (with and without dysthyroid optic neuropathy) were compared. RESULTS: One hundred and two orbits of 61 patients with Graves' orbitopathy met the inclusion criteria and were analyzed. Forty-one orbits were diagnosed with Graves' orbitopathy, and 61 orbits did not have optic neuropathy. The two groups of orbits differed significantly with regard to both of the volumetric indexes (p<0.001). Although both indexes had good discrimination ability, the volumetric orbital apex crowding index yielded the best results with 92% sensitivity, 86% specificity, 81%/94% positive/negative predictive value and 88% accuracy at a cutoff of 4.14. CONCLUSION: This study found that the orbital volumetric crowding index was a more effective predictor of dysthyroid optic neuropathy than previously described computed tomography indexes were.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

BACKGROUND AND PURPOSE: DON, a serious complication of GO, is frequently difficult to diagnose clinically in its early stages because of confounding signs and symptoms of congestive orbitopathy. We evaluated the ability of square area measurements of orbital apex crowding, calculated with MDCT, to detect DON. MATERIALS AND METHODS: Fifty-six patients with GO were studied prospectively with complete neuro-ophthalmologic examination and MDCT scanning. Square measurements were taken from coronal sections 12 mm, 18 mm, and 24 mm from the interzygomatic line. The ratio between the extraocular muscle area and the orbital bone area was used as a Cl. Intracranial fat prolapse through the superior orbital fissure was recorded as present or absent. Severity of optic nerve crowding was also subjectively graded on corona! images. Orbits were divided into 2 groups (with or without clinical evidence of DON) and compared. RESULTS: Ninety-five orbits (36 with and 59 without DON) were studied. The CIs at all 3 levels and the subjective crowding score were significantly greater in orbits with DON (P<.001). No significant difference was observed regarding intracranial fat prolapse (P=.105). The area under the ROC curves was 0.91, 0.93, and 0.87 for CIs at 12, 18, and 24 mm, respectively. The best performance was at 18 mm, where a cutoff value of 57.5% corresponded to 91.7% sensitivity, 89.8% specificity, and an odds ratio of 97.2 for detecting DON. A significant correlation (P<.001) between the CIs and VF defects was observed. CONCLUSIONS: Orbital Cls based on area measurements were found to predict DON more reliably than subjective grading of orbital crowding or intracranial fat prolapse.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

OBJETIVO: Avaliar o efeito da corrente catódica de alta voltagem sobre a dor em um modelo experimental de ciatalgia. MÉTODOS: Foram utilizados 16 ratos Wistar, machos, submetidos a um modelo de ciatalgia experimental no membro pélvico direito. Os sujeitos foram divididos em grupo simulacro (GS) e grupo tratado com corrente catódica (GP-) por 20 min diários durante 10 dias. O modelo de compressão foi realizado com amarria por fio catgut 4.0 cromado, em quatro pontos ao longo do nervo isquiático. A avaliação da nocicepção foi realizada, de forma funcional, com o tempo de elevação da pata (TEP), e à pressão, pelo limiar de retirada, via analgesímetro eletrônico. Os dados foram coletados antes do modelo de ciatalgia (AV1), três dias depois da compressão (antes, AV2, e após o tratamento, AV3), após o quinto dia de tratamento (AV4) e em seguida ao décimo dia de tratamento (AV5). RESULTADOS: Pela avaliação funcional, em ambos os grupos houve aumento da nocicepção, sem redução da mesma em qualquer momento da avaliação. À pressão, no entanto, o GS mostrou redução do limiar de retirada em todos os momentos, enquanto o GP- apresentou redução do limiar apenas inicialmente - em AV5 o limiar foi restaurado. CONCLUSÃO: Não houve alteração na nocicepção pela avaliação funcional; porém, à pressão, o tratamento com corrente catódica mostrou efeito com a somatória de terapias.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Mediastinal mass syndrome remains an anaesthetic challenge that cannot be underestimated. Depending on the localization and the size of the mediastinal tumour, the clinical presentation is variable ranging from a complete lack of symptoms to severe cardiorespiratory problems. The administration of general anaesthesia can be associated with acute intraoperative or postoperative cardiorespiratory decompensation that may result in death due to tumour-related compression syndromes. The role of the anaesthesiologist, as a part of the interdisciplinary treatment team, is to ensure a safe perioperative period. However, there is still no structured protocol available for perioperative anaesthesiological procedure. The aim of this article is to summarize the genesis of and the diagnostic options for mediastinal mass syndrome and to provide a solid detailed methodology for its safe perioperative management based on a review of the latest literature and our own clinical experiences. Proper anaesthetic management of patients with mediastinal mass syndrome begins with an assessment of the preoperative status, directed foremost at establishing the localization of the tumour and on the basis of the clinical and radiological findings, discerning whether any vital mediastinal structures are affected. We have found it helpful to assign 'severity grade' (using a three-grade clinical classification scale: 'safe', 'uncertain', 'unsafe'), whereby each stage triggers appropriate action in terms of staffing and apparatus, such as the provision of alternatives for airway management, cardiopulmonary bypass and additional specialists. During the preoperative period, we are guided by a 12-point plan that also takes into account the special features of transportation into the operating theatre and patient monitoring. Tumour compression on the airways or the great vessels may create a critical respiratory and/or haemodynamic situation, and therefore the standard of intraoperative management includes induction of anaesthesia in the operating theatre on an adjustable surgical table, the use of short-acting anaesthetics, avoidance of muscle relaxants and maintenance of spontaneous respiration. In the case of severe clinical symptoms and large mediastinal tumours, we consider it absolutely essential to cannulate the femoral vessels preoperatively under local anaesthesia and to provide for the availability of cardiopulmonary bypass in the operating theatre, should extracorporeal circulation become necessary. The benefits of establishing vascular access under local anaesthesia clearly outweigh any associated degree of patient discomfort. In the case of patients classified as 'safe' or 'uncertain', a preoperative consensus with the surgeons should be reached as to the anaesthetic approach and the management of possible complications.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The perioperative management of patients with mediastinal masses is a special clinical challenge in our field. Even though regional anaesthesia is normally the first choice, in some cases it is not feasible due to the method of operation. In these cases general anaesthesia is the second option but can lead to respiratory and haemodynamic decompensation due to tumor-associated compression syndrome (mediastinal mass syndrome). The appropriate treatment begins with the preoperative risk classification on the basis of clinical and radiological findings. In addition to anamnesis, chest radiograph, and CT, dynamical methods (e.g. pneumotachography and echocardiography) should be applied to verify possible intraoperative compression syndromes. The induction of general anaesthesia is to be realized in awake-fiberoptic intubation with introduction of the tube via nasal route while maintaining the spontaneous breathing of the patient. The anaesthesia continues with short effective agents applied inhalative or iv. If possible from the point of operation, agents of muscle relaxation are not to be applied. If the anaesthesia risk is classified as uncertain or unsafe, depending on the location of tumor compression (tracheobronchial tree, pulmonary artery, superior vena cava), alternative techniques of securing the respiratory tract (different tubes, rigid bronchoscope) and cardiopulmonary bypass with extracorporal oxygen supply are prepared. For patients with severe clinical symptoms and extensive mediastinal mass, the preoperative cannulation of femoral vessels is also recommended. In addition to fulfilling technical and personnel requirements, an interdisciplinary cooperation of participating fields is the most important prerequisite for the optimal treatment of patients.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Työssä selvitettiin sähkötoimisten käsiproteesien nykyteknologian taso. Selvitettäviä asioita olivat keskushermoston ja proteesin välisen hermokytkennän toteutustapa, sähkötoimisten käsiproteesien keskeiset tekniset ominaisuudet sekä käsiproteesin mekaaniset toteutustavat. Tutkimus suoritettiin kirjallisuustutkimuksena. Työhön valittiin esimerkkejä kaupallisesti saatavilla olevista käsiproteeseista jotka löytyivät internetistä hakemalla kaikkein edisty-neintä käsiproteesia. Työstä rajattiin pois proteesin suora kytkeminen keskushermostoon. Liikeinformaation välitys aivoilta proteesille onnistuu mittaamalla lihassähkökäyrä erilaisilla ihon ja lihasten päälle, ihon alle lihaksien yhteyteen tai suoraan hermojen yhteyteen asete-tuilla elektrodeilla. Lihassähkökäyrän mittaamisessa ihon pinnalta on ongelmana sähkömag-neettinen säteily, hiki, joka muuttaa ihon impedanssia ja elektrodien meneminen pois paikal-taan. Ihon alle asetettavat elektrodit kapseloituvat, mikä heikentää niiden toimintaa ja nii-den ihon läpi kulkevat johdot voivat altistaa kohdan infektioille tai takertua johonkin. Her-moihin suorassa kosketuksissa olevat elektrodit aiheuttavat lisäksi hermopinteen. Kohden-netulla uudelleenhermotuksella voidaan hermosyyt johtaa lihaksiin, jolloin lihaksista saa-daan biologiset vahvistimet lihassähkökäyrää varten tai korvaavalle ihoalueelle, johon koh-distuva kosketus tuottaa tuntemuksen käteen kohdistuvasta kosketuksesta. Käden menet-tämisen myötä menetettävät hermo-ohjaustiedot voivat osittain korvautua aivojen mukau-tuvuuden ansiosta, mikä mahdollistaa tekokäden käyttämisen oppimisen samalla tavoin kuin polkupyörällä ajon. Hermotakaisinkytkentä mahdollistaa proteesin paremman hallin-nan. On mahdollista valmistaa keinoihoa johon kohdistuva paine saa aikaan muutoksen sen sähköisissä ominaisuuksissa, mitä voidaan sitten käyttää varsinaisen hermoärsytyksen luo-van laitteen, kuten tynkää ärsyttävän täryttimen, ohjaamisessa. On mahdollista valmistaa keinolihaksia joiden avulla nivelten liike voidaan toteuttaa luonnollisen kaltaisilla rakenteilla ja jotka ovat jopa kymmeniä kertoja voimakkaampia kuin aidot lihakset. Nykyteknologian avulla on mahdollista rakentaa käsiproteesi joka liikeradoiltaan, voimal-taan ja hermotakaisinkytkennän osalta vastaa lähes täydellisesti aitoa ihmiskättä. Haasteena on vielä kokeiluasteella oleva teknologian taso sekä korkea hinta.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Purpose The aim of this study was to test the correlation between Fourier-domain (FD) optical coherence tomography (OCT) macular and retinal nerve fibre layer (RNFL) thickness and visual field (VF) loss on standard automated perimetry (SAP) in chiasmal compression. Methods A total of 35 eyes with permanent temporal VF defects and 35 controls underwent SAP and FD-OCT (3D OCT-1000; Topcon Corp.) examinations. Macular thickness measurements were averaged for the central area and for each quadrant and half of that area, whereas RNFL thickness was determined for six sectors around the optic disc. VF loss was estimated in six sectors of the VF and in the central 16 test points in the VF. The correlation between VF loss and OCT measurements was tested with Spearman`s correlation coefficients and with linear regression analysis. Results Macular and RNFL thickness parameters correlated strongly with SAP VF loss. Correlations were generally stronger between VF loss and quadrantic or hemianopic macular thickness than with sectoral RNFL thickness. For the macular parameters, we observed the strongest correlation between macular thickness in the inferonasal quadrant and VF loss in the superior temporal central quadrant (rho=0.78; P<0.001) whereas for the RNFL parameters the strongest correlation was observed between the superonasal optic disc sector and the central temporal VF defect (rho=0.60; P<0.001).

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Voltage-gated sodium channels have been implicated in acute and chronic neuropathic pain. Among subtypes, Nav1.7 single mutations can cause congenital indifference to pain or chronic neuropathic pain syndromes, including paroxysmal ones. This channel is co-expressed with Nav1.8, which sustains the initial action potential; Nav1.3 is an embrionary channel which is expressed in neurons after injury, as in neuropathic conditions. Few studies are focused on the expression of these molecules in human tissues having chronic pain. Trigeminal neuralgia (TN) is an idiopathic paroxysmal pain treated with sodium channel blockers. The aim of this study was to investigate the expression of Nav1.3, Nav1.7 and Nav1.8 by RT-PCR in patients with TN, compared to controls. The gingival tissue was removed from the correspondent trigeminal area affected. We found that Nav1.7 was downregulated in TN (P=0.017) and Nav1.3 was upregulated in these patients (P=0.043). We propose a physiopathological mechanism for these findings. Besides vascular compression of TN, this disease might be also a channelopathy. (C) 2009 IBRO. Published by Elsevier Ltd. All rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Nerve and tendon gliding exercises are advocated in the conservative and postoperative management of carpal tunnel syndrome (CTS). However, traditionally advocated exercises elongate the nerve bedding substantially, which may induce a potentially deleterious strain in the median nerve with the risk of symptom exacerbation in some patients and reduced benefits from nerve gliding. This study aimed to evaluate various nerve gliding exercises, including novel techniques that aim to slide the nerve through the carpal tunnel while minimizing strain (sliding techniques). With these sliding techniques, it is assumed that an increase in nerve strain due to nerve bed elongation at one joint (e.g., wrist extension) is simultaneously counterbalanced by a decrease in nerve bed length at an adjacent joint (e.g., elbow flexion). Excursion and strain in the median nerve at the wrist were measured with a digital calliper and miniature strain gauge in six human cadavers during six mobilization techniques. The sliding technique resulted in an excursion of 12.4 mm, which was 30% larger than any other technique (p 0.0002). Strain also differed between techniques (p 0.00001), with minimal peak values for the sliding technique. Nerve gliding associated with wrist movements can be considerably increased and nerve strain substantially reduced by simultaneously moving neighboring joints. These novel nerve sliding techniques are biologically plausible exercises for CTS that deserve further clinical evaluation. © 2007 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 25:972-980, 2007

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Objectives/Hypothesis: To analyze clinical and epidemiological features of neck nerve schwannomas, with emphasis on the neurologic outcome after surgical excision sparing as much of nerve fibers as possible with enucleation technique. Study Design: Retrospective study. Methods: Review of medical records from 1987 to 2006 of patients with neck nerve schwannomas, treated in a single institution. Results: Twenty-two patients were identified. Gender distribution was equal and age ranged from 15 to 61 years (mean: 38.6 years). Seven vagal, four brachial plexus, four sympathetic trunk, three cervical plexus, and two lesions on other sites could be identified. Most common symptom was neck mass. Local or irradiated pain also occurred in five cases. Median growing rate of tumors was 3 mm per year. Nerve paralysis was noted twice (a vagal schwannoma and a hypoglossal paralysis compressed by a vagal schwannoma). Different techniques were employed, and seven out of nine patients kept their nerve function (78%) after enucleation. No recurrence was observed in follow-up. Conclusions: Schwannomas should be treated surgically because of its growing potential, leading to local and neural compression symptoms. When possible, enucleation, which was employed in 10 patients of this series, is the recommended surgical option, allowing neural function preservation or restoration in most instances. This is especially important in the head and neck, where denervation may have a significant impact on the quality of life.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

PURPOSE: To compare the ability of Fourier-domain (FD) optical coherence tomography (3D OCT-1000; Top, con, Tokyo, Japan) and time domain (TD) OCT (Stratus; Carl Zeiss Meditec Inc, Dublin, California, USA) to detect axonal loss in eyes with band atrophy (BA) of the optic nerve. DESIGN: Cross-sectional study. METHODS: Thirty-six eyes from 36 patients with BA and temporal visual field (VF) defect from chiasmal compression and 36 normal eyes were studied. Subjects were submitted to standard automated perimetry and macular and retinal nerve fiber layer (RNFL) measurements were taken using 3D OCT-1000 and Stratus OCT. Receiver operating characteristic (ROC) curves were calculated for each parameter. Spearman correlation coefficients were obtained to evaluate the relationship between RNFL and macular thickness parameters and severity of VF loss. Measurements from the two devices were compared. RESULTS: Regardless of OCT device, all RNFL and macular thickness parameters were significantly lower in eyes with BA compared with normal eyes, but no statistically significant difference was found with regard to the area under the ROC curve. Structure-function relationships were also similar for the two devices. In both groups, RNFL and macular thickness measurements were generally and in some cases significantly smaller with 3D OCT-1000 than with Stratus OCT. CONCLUSIONS: The introduction of FD technology did not lead to better discrimination ability for detecting BA of the optic nerve compared with TD technology when using the software currently provided by the manufacturer. 3D OCT-1000 FD OCT RNFL and macular measurements were generally smaller than TD Stratus OCT measurements. Investigators should be aware of this fact when comparing measurements obtained with these two devices. (Am J Oplathalmol 2009;147: 56-63. (c) 2009 by Elsevier Inc. All rights reserved.)