329 resultados para NIRS. Bact


Relevância:

20.00% 20.00%

Publicador:

Resumo:

We report on oxygenation changes noninvasively recorded by multichannel continuous-wave near infrared spectroscopy (CW-NIRS) during endovascular neuroradiologic interventions requiring temporary balloon occlusion of arteries supplying the cerebral circulation. Digital subtraction angiography (DSA) provides reference data on the site, timing, and effectiveness of the flow stagnation as well as on the amount and direction of collateral circulation. This setting allows us to relate CW-NIRS findings to brain specific perfusion changes. We focused our analysis on the transition from normal perfusion to vessel occlusion, i.e., before hypoxia becomes clinically apparent. The localization of the maximal response correlated either with the core (occlusion of the middle cerebral artery) or with the watershed areas (occlusion of the internal carotid artery) of the respective vascular territories. In one patient with clinically and angiographically confirmed insufficient collateral flow during carotid artery occlusion, the total hemoglobin concentration became significantly asymmetric, with decreased values in the ipsilateral watershed area and contralaterally increased values. Multichannel CW-NIRS monitoring might serve as an objective and early predictive marker of critical perfusion changes during interventions-to prevent hypoxic damage of the brain. It also might provide valuable human reference data on oxygenation changes as they typically occur during acute stroke.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of the present study was (i) to investigate the effect of inner speech on cerebral hemodynamics and oxygenation, and (ii) to analyze if these changes could be the result of alternations of the arterial carbon dioxide pressure (PaCO2). To this end, in seven adult volunteers, we measured changes of cerebral absolute [O2Hb], [HHb], [tHb] concentrations and tissue oxygen saturation (StO2) (over the left and right anterior prefrontal cortex (PFC)), as well as changes in end-tidal CO2 (PETCO2), a reliable and accurate estimate of PaCO2. Each subject performed three different tasks (inner recitation of hexameter (IRH) or prose (IRP) verses) and a control task (mental arithmetic (MA)) on different days according to a randomized crossover design. Statistical analysis was applied to the differences between pre-baseline, two tasks, and four post-baseline periods. The two brain hemispheres and three tasks were tested separately. During the tasks, we found (i) PETCO2 decreased significantly (p < 0.05) during the IRH ( ~ 3 mmHg) and MA ( ~ 0.5 mmHg) task. (ii) [O2Hb] and StO2 decreased significantly during IRH ( ~ 1.5 μM; ~ 2 %), IRP ( ~ 1 μM; ~ 1.5 %), and MA ( ~ 1 μM; ~ 1.5 %) tasks. During the post-baseline period, [O2Hb] and [tHb] of the left PFC decreased significantly after the IRP and MA task ( ~ 1 μM and ~ 2 μM, respectively). In conclusion, the study showed that inner speech affects PaCO2, probably due to changes in respiration. Although a decrease in PaCO2 is causing cerebral vasoconstriction and could potentially explain the decreases of [O2Hb] and StO2 during inner speech, the changes in PaCO2 were significantly different between the three tasks (no change in PaCO2 for MA) but led to very similar changes in [O2Hb] and StO2. Thus, the cerebral changes cannot solely be explained by PaCO2.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A Near Infrared Spectroscopy (NIRS) industrial application was developed by the LPF-Tagralia team, and transferred to a Spanish dehydrator company (Agrotécnica Extremeña S.L.) for the classification of dehydrator onion bulbs for breeding purposes. The automated operation of the system has allowed the classification of more than one million onion bulbs during seasons 2004 to 2008 (Table 1). The performance achieved by the original model (R2=0,65; SEC=2,28ºBrix) was enough for qualitative classification thanks to the broad range of variation of the initial population (18ºBrix). Nevertheless, a reduction of the classification performance of the model has been observed with the passing of seasons. One of the reasons put forward is the reduction of the range of variation that naturally occurs during a breeding process, the other is the variations in other parameters than the variable of interest but whose effects would probably be affecting the measurements [1]. This study points to the application of Independent Component Analysis (ICA) on this highly variable dataset coming from a NIRS industrial application for the identification of the different sources of variation present through seasons.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Espécies forrageiras adaptadas às condições semiáridas são uma alternativa para reduzir os impactos negativos na cadeia produtiva de ruminantes da região Nordeste brasileira devido à sazonalidade na oferta de forragem, além de reduzir custo com o fornecimento de alimentos concentrados. Dentre as espécies, a vagem de algaroba (Prosopis juliflora SW D.C.) e palma forrageira (Opuntia e Nopalea) ganham destaque por tolerarem o déficit hídrico e produzirem em períodos onde a oferta de forragem está reduzida, além de apresentam bom valor nutricional e serem bem aceitas pelos animais. Porém, devido à variação na sua composição, seu uso na alimentação animal exige o conhecimento profundo da sua composição para a elaboração de dietas balanceadas. No entanto, devido ao custo e tempo para análise, os produtores não fazem uso da prática de análise da composição químico-bromatológica dos alimentos. Por isto, a espectroscopia de reflectância no infravermelho próximo (NIRS) representa uma importante alternativa aos métodos tradicionais. Objetivou-se com este estudo desenvolver e validar modelos de predição da composição bromatológica de vagem de algaroba e palma forrageira baseados em espectroscopia NIRS, escaneadas em dois modelos de equipamentos e com diferentes processamentos da amostra. Foram coletadas amostras de vagem de algaroba nos estados do Ceará, Bahia, Paraíba e Pernambuco, e amostras de palma forrageira nos estados do Ceará, Paraíba e Pernambuco, frescas (in natura) ou pré-secas e moídas. Para obtenção dos espectros utilizaram-se dois equipamentos NIR, Perten DA 7250 e FOSS 5000. Inicialmente os alimentos foram escaneados in natura em aparelho do modelo Perten, e, com o auxílio do software The Unscrambler 10.2 foi selecionado um grupo de amostras para o banco de calibração. As amostras selecionadas foram secas e moídas, e escaneadas novamente em equipamentos Perten e FOSS. Os valores dos parâmetros de referência foram obtidos por meio de metodologias tradicionalmente aplicadas em laboratório de nutrição animal para matéria seca (MS), matéria mineral (MM), matéria orgânica (MO), proteína bruta (PB), estrato etéreo (EE), fibra solúvel em detergente neutro (FDN), fibra solúvel em detergente ácido (FDA), hemicelulose (HEM) e digestibilidade in vitro da matéria seca (DIVMS). O desempenho dos modelos foi avaliado de acordo com os erros médios de calibração (RMSEC) e validação (RMSECV), coeficiente de determinação (R2 ) e da relação de desempenho de desvio dos modelos (RPD). A análise exploratória dos dados, por meio de tratamentos espectrais e análise de componentes principais (PCA), demonstraram que os bancos de dados eram similares entre si, dando segurança de desenvolver os modelos com todas as amostras selecionadas em um único modelo para cada alimento, algaroba e palma. Na avaliação dos resultados de referência, observou-se que a variação dos resultados para cada parâmetro corroboraram com os descritos na literatura. No desempenho dos modelos, aqueles desenvolvidos com pré-processamento da amostra (pré-secagem e moagem) se mostraram mais robustos do que aqueles construídos com amostras in natura. O aparelho NIRS Perten apresentou desempenho semelhante ao equipamento FOSS, apesar desse último cobrir uma faixa espectral maior e com intervalos de leituras menores. A técnica NIR, associada ao método de calibração multivariada de regressão por meio de quadrados mínimos (PLS), mostrou-se confiável para prever a composição químico-bromatológica de vagem de algaroba e da palma forrageira. Abstract: Forage species adapted to semi-arid conditions are an alternative to reduce the negative impacts in the feed supply for ruminants in the Brazilian Northeast region, due to seasonality in forage availability, as well as in the reducing of cost by providing concentrated feedstuffs. Among the species, mesquite pods (Prosopis juliflora SW DC) and spineless cactus (Opuntia and Nopalea) are highlighted for tolerating the drought and producion in periods where the forage is scarce, and have high nutritional value and also are well accepted by the animals. However, its use in animal diets requires a knowledge about its composition to prepare balanced diets. However, farmers usually do not use feed composition analysis, because their high cost and time-consuming. Thus, the Near Infrared Reflectance Spectroscopy in the (NIRS) is an important alternative to traditional methods. The objective of this study to develop and validate predictive models of the chemical composition of mesquite pods and spineless cactus-based NIRS spectroscopy, scanned in two different spectrometers and sample processing. Mesquite pods samples were collected in the states of Ceará, Bahia, Paraiba and Pernambuco, and samples of forage cactus in the states of Ceará, Paraíba and Pernambuco. In order to obtain the spectra, it was used two NIR equipment: Perten DA 7250 and FOSS 5000. sSpectra of samples were initially obtained fresh (as received) using Perten instrument, and with The Unscrambler software 10.2, a group of subsamples was selected to model development, keeping out redundant ones. The selected samples were dried and ground, and scanned again in both Perten and FOSS instruments. The values of the reference analysis were obtained by methods traditionally applied in animal nutrition laboratory to dry matter (DM), mineral matter (MM), organic matter (OM), crude protein (CP), ether extract (EE), soluble neutral detergent fiber (NDF), soluble acid detergent fiber (ADF), hemicellulose ( HEM) and in vitro digestibility of dry matter (DIVDM). The performance of the models was evaluated according to the Root Mean Square Error of Calibration (RMSEC) and cross-validation (RMSECV), coefficient of determination (R2 ) and the deviation of Ratio of performance Deviation of the models (RPD). Exploratory data analysis through spectral treatments and principal component analysis (PCA), showed that the databases were similar to each other, and may be treated asa single model for each feed - mesquite pods and cactus. Evaluating the reference results, it was observed that the variation were similar to those reported in the literature. Comparing the preprocessing of samples, the performance ofthose developed with preprocessing (dried and ground) of the sample were more robust than those built with fresh samples. The NIRS Perten device performance similar to FOSS equipment, although the latter cover a larger spectral range and with lower readings intervals. NIR technology associate do multivariate techniques is reliable to predict the bromatological composition of mesquite pods and cactus.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Conventional reflectance spectroscopy (NIRS) and hyperspectral imaging (HI) in the near-infrared region (1000-2500 nm) are evaluated and compared, using, as the case study, the determination of relevant properties related to the quality of natural rubber. Mooney viscosity (MV) and plasticity indices (PI) (PI0 - original plasticity, PI30 - plasticity after accelerated aging, and PRI - the plasticity retention index after accelerated aging) of rubber were determined using multivariate regression models. Two hundred and eighty six samples of rubber were measured using conventional and hyperspectral near-infrared imaging reflectance instruments in the range of 1000-2500 nm. The sample set was split into regression (n = 191) and external validation (n = 95) sub-sets. Three instruments were employed for data acquisition: a line scanning hyperspectral camera and two conventional FT-NIR spectrometers. Sample heterogeneity was evaluated using hyperspectral images obtained with a resolution of 150 × 150 μm and principal component analysis. The probed sample area (5 cm(2); 24,000 pixels) to achieve representativeness was found to be equivalent to the average of 6 spectra for a 1 cm diameter probing circular window of one FT-NIR instrument. The other spectrophotometer can probe the whole sample in only one measurement. The results show that the rubber properties can be determined with very similar accuracy and precision by Partial Least Square (PLS) regression models regardless of whether HI-NIR or conventional FT-NIR produce the spectral datasets. The best Root Mean Square Errors of Prediction (RMSEPs) of external validation for MV, PI0, PI30, and PRI were 4.3, 1.8, 3.4, and 5.3%, respectively. Though the quantitative results provided by the three instruments can be considered equivalent, the hyperspectral imaging instrument presents a number of advantages, being about 6 times faster than conventional bulk spectrometers, producing robust spectral data by ensuring sample representativeness, and minimizing the effect of the presence of contaminants.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

P>Soil bulk density values are needed to convert organic carbon content to mass of organic carbon per unit area. However, field sampling and measurement of soil bulk density are labour-intensive, costly and tedious. Near-infrared reflectance spectroscopy (NIRS) is a physically non-destructive, rapid, reproducible and low-cost method that characterizes materials according to their reflectance in the near-infrared spectral region. The aim of this paper was to investigate the ability of NIRS to predict soil bulk density and to compare its performance with published pedotransfer functions. The study was carried out on a dataset of 1184 soil samples originating from a reforestation area in the Brazilian Amazon basin, and conventional soil bulk density values were obtained with metallic ""core cylinders"". The results indicate that the modified partial least squares regression used on spectral data is an alternative method for soil bulk density predictions to the published pedotransfer functions tested in this study. The NIRS method presented the closest-to-zero accuracy error (-0.002 g cm-3) and the lowest prediction error (0.13 g cm-3) and the coefficient of variation of the validation sets ranged from 8.1 to 8.9% of the mean reference values. Nevertheless, further research is required to assess the limits and specificities of the NIRS method, but it may have advantages for soil bulk density predictions, especially in environments such as the Amazon forest.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The present study aims at the use of Raman spectroscopy in the quantification of unsaturated fats in fat-containing foods, compared to the information available in the Nutritional Table, to obtain a non-destructive optical quantification of unsaturation. Raman spectra of edible oil, margarine, mayonnaise, hydrogenated fat, and butter were obtained with a near-infrared Raman spectrometer (830nm). By analyzing selected bands in the regions of 1750, 1660, 1440, 1300, and 1260cm-1, the amount of total and unsaturated fat of samples of oil, margarine, and mayonnaise were correlated with the information displayed in the Nutritional Table. The amount of unsaturated trans fat in selected samples was correlated to the Raman shift of 1660cm-1. Dispersive Raman spectroscopy was shown to be effective in quantifying the unsaturated fats in oil, margarine, and mayonnaise, and trans fat in hydrogenated oils and butter.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Dissertação de Mestrado, Engenharia Zootécnica, 10 de Setembro de 2015, Universidade dos Açores.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Eur. J. Biochem. 271, 2361–2369 (2004)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

O tema “Plataforma smartphone para biossensores de Espectroscopia de Infravermelho Próximo”, surge no âmbito da instrumentação médica, na área das BCI – Brain Computer Interfaces, devido à necessidade de encontrar um dispositivo portátil, de custo acessível e elevada performance que permita obter informação acerca da actividade neuronal do córtex motor no decorrer duma determinada tarefa. O objectivo do trabalho consiste no desenvolvimento duma sonda capaz de detectar as alterações hemodinâmicas que ocorrem no córtex, bem como toda a instrumentação inerente à aquisição do sinal e transmissão dos dados para um computador, a análise dos dados e por fim o desenvolvimento de uma aplicação em Android para visualização dos resultados. Foi desenvolvida uma banda para a cabeça, composta pela sonda NIRS: LEDs (Light-Emiting Diodes) de 940nm e 660nm e os respectivos fototransístores de detecção, bem como toda a electrónica de condicionamento do sinal captado. Num módulo à parte, alimentado por duas baterias de 9V, encontram-se os circuitos electrónicos onde é possível regular ganhos de amplificação e offsets. Os dados foram adquiridos pelo microcontrolador Arduíno Uno, usando uma taxa de amostragem de 50Hz em cada um dos dois canais utilizados. O controlo do Arduíno foi feito utilizando o LabVIEW. Para o processamento dos dados, visualização e cálculo das concentrações de oxi e desoxi-hemoglobina no sangue recorreu-se ao Matlab. O sistema foi calibrado com recurso a um oxímetro de pulso clínico usado em cinco indivíduos saudáveis. Finalmente o sistema foi testado ao colocar-se o sensor NIRS sobre o córtex motor esquerdo de nove indivíduos saudáveis destros, fazendo-se uma aquisição de dados durante dois minutos. Utilizou-se um paradigma de 10s de repouso seguido de 10s a abrir e fechar a mão. O sistema NIRS conseguiu medir as alterações que ocorrem nas concentrações de oxi e desoxi-hemoglobina devido à actividade motora de abrir e fechar a mão. Dado o princípio físico ser o mesmo do dos oxímetros convencionais, conseguiu-se ainda medir com sucesso a frequência cardíaca e a saturação percentual de oxigénio após a calibração do sensor. As medidas podem ser visualizadas numa aplicação desenvolvida para o Android. Os resultados sugerem que com esta abordagem, este tipo de dispositivo pode estar disponível a baixo custo quer para doentes quer para indivíduos saudáveis, por exemplo em aplicações de telemóvel.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

INTRODUCTION: Staphylococcus pettenkoferi was originally isolated and described by Trülzsch et al (2002). In this study, we characterized two isolates of this newly described species. METHODS: Blood cultures were initially processed using the BacT/ALERT® device, and the isolates were initially characterized using the Vitek2 identification system. RESULTS: The initial characterization revealed slow-growing Gram-positive cocci that formed opaque colonies on sheep blood agar. Other phenotypic/genotypic tests were performed. CONCLUSIONS: We would like to emphasize that this new staphylococcus species is phenotypically similar to other CoNS, especially S. auricularis. This could potentially lead to misidentification of these uncommon species.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Devido à falta de informações sobre Urbanus acawoios (Williams, 1926) (Lepidoptera: Hesperiidae), e pelos danos severos por ele causados em árvores de Clitoria racemosa, o presente trabalho foi desenvolvido sob condições de laboratório para verificar a possibilidade de utilizar Bacillus thuringiensis var. kurstaki (H-3a:3b) como agente microbiano para o seu controle. O pH do intestino médio do hesperídeo mostrou ser bastante alcalino, variando de 8,4 a 9,2 (média de 8,7), indicando a possibilidade das larvas serem susceptíveis ao patógeno. Os ensaios confirmaram a alta susceptibilidade a dosagens equivalentes a 110 g / ha, resultando em tempos letais medianos (TL50) de 42,28, 37,18, 28,00 e 51,87 horas para larvas de 3o, 4°, início e final do 5º ínstares, respectivamente. Três outras dosagens (80, 150 e 280 g/h) foram aplicadas para larvas do 3º ínstar, resultando em TLs50 de 42,62, 30,77 e 30,06 horas, respectivamente. Descrições detalhadas sobre os sintomas externos nas larvas infectadas foram dadas. As alterações histológicas do intestino médio afetado pela d-endotoxina de B. thuringiensis foram descritas. Os resultados obtidos no presente trabalho revelam a grande possibilidade de controlar esta praga utilizando-se produtos e formulados à base desta bactéria.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Estudi elaborat a partir d’una estada al Swedish University of Agricultural Sciences (Suècia ) entre setembre i desembre del 2006. El SAC-Empuriabrava va ser dissenyat per dur a terme el tractament terciari de l’aigua que prové d’una estació depuradora. La purificació en un sistema d’aiguamolls construïts engloba una complexa barreja de processos on es troben implicats el sediment, la vegetació i les comunitats microbianes relacionades amb aquests. Un dels passos clau en l’eliminació de nitrogen és la desnitrificació, coneguda com la reducció seqüencial d’òxids de nitrogen que desemboca en la pèrdua neta de nitrogen molecular a l’atmosfera, catalitzada exclusivament per microorganismes. Els bacteris desnitrificants es troben àmpliament distribuïts en les divisions de l’arbre filogenètic procariota, fet que restringeix la seva anàlisi a marcadors moleculars basats en gens funcionals dels enzims implicats en la desnitrificació tals com narG nirS, nirK, nrfA nosZ. Tot i que l’estudi del marcador molecular nirS de desnitrificants s’ha dut a terme amb èxit, no ha estat possible analitzar altres marcadors com nosZ, que codifica la òxid nitrós reductasa, responsable de l’últim pas de la desnitrificació. L’ interès principal ha estat doncs estendre l’ àrea d’estudi a aquest marcador per tal de proveir una visió complerta de la comunitat desnitrificant. S’ha analitzat la comunitat desnitrificant de la rizosfera i sediment del SACEmpuriabrava a través del monitoreig del gen nosZ per PCR-DGGE, comparant alhora diferents períodes de temps afectats per diferents condicions hídriques. Amb la mateixa intenció, s’ha dut a terme assajos d’activitat desnitrificant mitjançant cromatografia de gasos, mesurant en aquest cas la producció de nitrogen gas que representa la consecució de la desnitrificació completa.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Background: Inadequate intraoperative cerebral perfusion has been suggested as a possible cause of postoperative cognitive dysfunction (POCD). Methods: We investigated 35 patients aged 65 or older undergoing elective major non-cardiac surgery under standardized general anaesthesia (thiopental, sevoflurane, fentanyl, atracurium). Intraoperative cerebral perfusion was monitored with transcranial Doppler, and near-infrared spectroscopy (NIRS). Arterial blood pressure was monitored continuously with a Finapres device. Mx, an index allowing continuous monitoring of cerebrovascular autoregulation based on the changes in mean arterial blood pressure (MAP) and cerebral blood flow velocity was calculated. Mx >0.5 was defined as disturbed cerebrovascular autoregulation. Cognitive function was measured preoperatively and 7 days postoperatively using the CERAD-NAB Plus test battery. A postoperative decline >1 z-score in at least two of the tested domains was defined as POCD. Data are shown as mean } SD. Results: Mean age was 75 } 7 yrs. Sixteen patients (46%) developed POCD. These patients were older (77 } 8 vs 73 } 7 yrs), had lower MAP (77 } 12 vs 81 } 11 mm Hg), lower cerebral tissue oxygenation indices measured by NIRS (66.8 } 6.0 vs 68.6 } 4.3%) and less efficient cerebrovascular autoregulation (Mx 0.54 } 0.17 and 0.44 } 0.22) than patients without POCD. Disturbed intraoperative cerebrovascular autoregulation was found more often (56 vs 37%) in patients with POCD. However, none of these differences reached statistical significance. Conclusions: Our data show a trend towards subtle changes in intraoperative cerebral perfusion in elderly patients who develop POCD. However, a cause effect relationship must not be assumed and a greater number of patients needs to be investigated patients. However, more patients need to be investigated to confirm and characterize these differences.