972 resultados para ND : YAG lasers


Relevância:

100.00% 100.00%

Publicador:

Resumo:

By employing a uniformly compact side-pumping system, a high-energy electro-optical Q-switched Nd:YAG ceramic laser has been demonstrated. With 420 W quasi-cw laser-diode-array pumping at 808 ran and a 100 Hz modulating repetition rate, 50 mJ output energy at 1064 nm was obtained with 10 ns pulse width, 5 W average output power, and 5 MW peak power. Its corresponding slope efficiency was 29.8%. The laser system operated quite stably and no saturation phenomena have been observed, which means higher output energy could be expected. Laser parameters between ceramic and single-crystal Nd:YAG lasers have been compared, and pulse characteristics of Nd:YAG ceramic with different repetition rate have been investigated in detail. The still-evolving Nd:YAG ceramics are potential super excellent media for high-energy laser applications. (C) 2007 Optical Society of America.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The aim of this study was to evaluate the apical sealing of dentinal tubules after root-end surface cutting by using Er:YAG and Nd:YAG lasers. After root-canal instrumentation and filling, apices of 50 extracted maxillary canine human teeth were resected by Er: YAG with 400 mJ, 10 Hz, for 30 sec. The samples were randomly assigned to five groups (n = 10): (GI) treated without root-end cavity, but with Nd: YAG (1.0W, 10 Hz, 20 sec) for dentinal tubules sealing; (GII) treated with root-end cavity without the use of Nd: YAG; (GIII) treated with root-end cavity and Nd: YAG application; (GIV) treated with root-end cavity made by Er: YAG with no focus and without Nd: YAG application; and (GV) treated without root-end cavity and without Nd: YAG application. The root-end cavities were performed by using Er: YAG at 300 mJ, 10 Hz, for 20 sec. Subsequently, all teeth were waterproofed and immersed in 2% methylene blue for 48 h in a vacuum environment. The samples were longitudinally sectioned, and microleakage was measured. ANOVA and the Fisher LSD test showed that GIV was less susceptible to microleakage than were the other groups (p < 0.05). Interestingly, the use of the Er: YAG with no focus showed superior dentinal tubule sealing in comparison with the other groups, even with or without root-end cavity and Nd: YAG application.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Objective: the ability of the laser irradiation to promote the cleaning and disinfection of the radicular canal system has become this type of treatment in a viable and real alternative in endodontics. The purpose of this study was to evaluate the apical marginal sealing of root canal fillings after the irradiation with the laser of Nd:YAG or of Er:YAG. Materials and Methods: Forty-two human, extracted single-rooted teeth had their crowns sectioned and the root canals prepared with a no. 70 K-file. Then, they were dried and divided into three groups according to canal wall treatment: group 1: the canals were filled with EDTA for 3 min, followed by irrigation with 1% sodium hypochlorite solution; group 2: the canal walls were irradiated with Nd:YAG laser; and group 3: the canal walls were irradiated with Er:YAG laser. Afterwards, the root canals were obturated by the lateral condensation technique. The roots were externally waterproof, except in the apical foramen and immerged in 2% methylene blue aqueous solution during 48 hours. Results: the results showed that the largest infiltrations happened in the group 3-Er:YAG (7.3 mm), proceeded by the group 1-EDTA (1.6 mm) and by the group 2-Nd:YAG (0.6 mm). The group Er:YAG differed statistically of the others (p < 0.05). Conclusion: It was concluded that the Er:YAG laser intracanal irradiation previously to the root canal filling must be used with caution until future research is define the best parameters for it's use.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Different types of laser have been widely studied for applicability in the oral health area. In the endodontic area, investigations with some types of laser have been conducted to establish safe parameters for clinical application in root canals. However, it has not been duly explained whether the temperature increase caused by laser irradiation could cause alteration in the temperature on the external surface of the root and, consequently, alterations in the cells of the periodontal ligament, causing resorption and even loss of the dental element. The proposal in this paper was to gauge the external root temperature in the apical and cervical regions of the roots of human teeth during root canal irradiation with Nd:yttrium aluminum garnet (YAG) and Er:YAG lasers using different parameters. The novel approach of this paper is the use of the technique of laser applications along the total length of the root canal with series of repetitive irradiation, however, using time of 1 s of irradiation associated with 1 s off to avoid cumulative thermal effects. Experimental results confirm the accuracy of the parameters and exposure regimen obtained. All the parameters used in this paper are acceptable from a clinical as well as a biological point of view. (C) 2009 Laser Institute of America.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Pós-graduação em Ciências Odontológicas - FOAR

Relevância:

100.00% 100.00%

Publicador:

Resumo:

To evaluate the effect of surface treatment with Er:YAG and Nd:YAG laser on resin composite bond strength to recently bleached dentin. Material and Methods: In this study 120 bovine incisors were used and distributed into two groups: Group C: without bleaching treatment; Group B: with bleaching treatment (35% hydrogen peroxide). Each group was divided into three subgroups: Subgroup N: without laser treatment; Subgroup Nd: irradiation with Nd:YAG laser; Subgroup Er: irradiation with Er:YAG laser. Next, the adhesive system (Adper Single Bond 2) was applied and composite buildups were constructed with Z350 composite. The teeth were sectioned to obtain dentin-resin sticks (1x1mm) and analyzed by microtensile bond testing. The data were statistically analyzed by the ANOVA and Tukey tests. Results: The results showed that the bond strength values in the bleached control group (16.17 MPa) presented no significant difference in comparison with the group bleached and irradiated with Er:YAG laser (14.69 MPa). The non bleached control group (26.79 MPa) presented significant difference in bond strength when compared with the non bleached group irradiated with Er:YAG laser (22.82 MPa) and with the group treated by bleaching and irradiation with Nd:YAG laser (28,792 MPa). The group without bleaching treatment and irradiated with Nd:YAG (36.1 MPa) presented a significant increase in bond strength in comparison with the other groups. Conclusion: The use of Nd:YAG laser on bleached specimens was able of completely reversing the immediate effects of bleaching, obtaining bond strength values similar to those of the control group

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This study evaluated the influence of the surface pretreatment of indirect resin composite (Signum, Admira Lab and Sinfony) on the microtensile bond strength of a resin cement. Sixty samples made of each brand were divided into 6 groups, according to surface treatment: (1) control; (2) controlled-air abrasion with Al2O3; (3) Er:YAG Laser 200 mJ, 10 Hz, for 10s; (4) Er: YAG Laser 300 mJ, 10 Hz, for 10 s; (5) Nd:YAG 80 mJ, S15Hz for 1 min; (6) Nd:YAG 120mJ, 15 Hz for 1 min. After treatments, all the groups received an application of 37% phosphoric acid and adhesive. The pair of blocks of the same brand were cemented to each other with dual resin cement. The blocks were sectioned to obtain resin-resin sticks (1 x1 mm) and analyzed by microtensile bond testing. The bond strength values were statistically different, irrespective of the surface treatment performed, with highest values for Sinfony (43.81 MPa) and lowest values for Signum (32.33 MPA). The groups treated with the Nd:YAG laser showed the lowest bond strength values and power did not interfere in the results, both for Nd:YAG laser and Er:YAG. Controlled-air abrasion with Al203 is an efficient surface treatment method and the use of the Nd:YAG and Er:YAG lasers reduced bond strength, irrespective of the intensity of energy used.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Pós-graduação em Odontologia Restauradora - ICT

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The suppressing effect of laser extraction on the non-radiation transition process is taken into account when the heat model of gain media is developed. Based on the developed heat model, the heat generation in the operating LD side-pumped Nd: YAG ceramic lasers is quantified through using the normalized heating parameter, which can be deduced from the experimental results of the slope efficiency and the absorbed pumping power of the gain media. The main factors which influence on the heat generation are investigated by studying the normalized heating parameter, and the results show that the changes of the laser extraction efficiency, the beam overlap efficiency and the Nd3+ concentration will result in obvious variations of the normalized heating parameter. In this work, the laser extraction efficiency increases to 0.905 by the optimization of the transmission of the output coupling, and the normalized heating parameter decrease to 0.474, correspondingly.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

通过热沉积系数研究在激光提取条件下掺杂原子分数为1.0%的NdYAG陶瓷激光器中热沉积问题.热沉积系数定义为热沉积功率与激光器输出功率之比.在理论分析基础上,通过测量激光器斜率效率来间接测定热沉积系数,实验测定的热沉积系数值为0.63.建立激光提取条件下NdYAG陶瓷发热模型,讨论了影响热沉积系数的主要因素.结果表明:热沉积系数对NdYAG陶瓷的辐射量子效率、交叠效率以及激光提取效率的变化非常敏感.为有效减少介质内热沉积,在激光器优化设计中交叠效率和激光提取效率是需要着重考虑的参数.所得结果可为进一

Relevância:

100.00% 100.00%

Publicador:

Resumo:

对高平均功率输出的激光二极管侧面抽运电光调Q倍频 Nd:YAG激光器进行了研究,当采用90个60W的脉冲激光二极管阵列抽运时,在重复频率为10Hz下,实现了最大平均功率为1180mW的1064nm红外激光输出,光-光转换效率为11%。腔外倍频获得600mW的532nm绿光输出,倍频效率达到50%以上。

Relevância:

100.00% 100.00%

Publicador:

Resumo:

实验研究了腔内位相锁定来至一LAD侧面抽运的NdYAG板条的两束激光,输出镜面出现干涉条纹,获得1.13W的相干光,其组束效率达到64.9%,相干度约60%。实验中发现只需要一根作为滤波的金属丝放在离输出镜合适的位置都就能有效稳定干涉条纹,金属丝引起的损耗低于8%。

Relevância:

100.00% 100.00%

Publicador:

Resumo:

实验研究了激光二极管阵列(LDA)侧向抽运国产NdYAG陶瓷棒的准连续及被动调Q激光输出特性。该陶瓷激光器采用LDA侧面紧密环绕均匀排布的抽运结构,陶瓷棒抽运区域长度为20 mm,其总尺寸为3 mm×35 mm,掺杂原子数分数为~1%。在千赫兹准连续运转条件下,当平-平谐振腔的输出耦合镜透过率为47.3%时,获得最大平均功率23 W的1064 nm激光输出,光束发散角为4.5 mrad,斜率效率达12%。在谐振腔内插入Cr4+∶YAG晶体作为被动调Q开关,成功地实现了陶瓷激光器千赫兹重复频率调Q激光脉冲输出,当Cr4+∶YAG晶体初始透过率为60%时,输出激光脉冲宽度(半峰全宽)可窄至14.5 ns,调Q动静比约为40%。