951 resultados para Municipal sewage treatment


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Point sources of wastewater pollution, including effluent from municipal sewage treatment plants and intensive livestock and processing industries, can contribute significantly to the degradation of receiving waters (Chambers et al. 1997; Productivity Commission 2004). This has led to increasingly stringent local wastewater discharge quotas (particularly regarding Nitrogen, Phosphorous and suspended solids), and many municipal authorities and industry managers are now faced with upgrading their existing treatment facilities in order to comply. However, with high construction, energy and maintenance expenses and increasing labour costs, traditional wastewater treatment systems are becoming an escalating financial burden for the communities and industries that operate them. This report was generated, in the first instance, for the Burdekin Shire Council to provide information on design aspects and parameters critical for developing duckweed-based wastewater treatment (DWT) in the Burdekin region. However, the information will be relevant to a range of wastewater sources throughout Queensland. This information has been collated from published literature and both overseas and local studies of pilot and full-scale DWT systems. This report also considers options to generate revenue from duckweed production (a significant feature of DWT), and provides specifications and component cost information (current at the time of publication) for a large-scale demonstration of an integrated DWT and fish production system.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

STOAT has been extensively used for the dynamic simulation of an activated sludge based wastewater treatment plant in the Titagarh Sewage Treatment Plant, near Kolkata, India. Some alternative schemes were suggested. Different schemes were compared for the removal of Total Suspended Solids (TSS), b-COD, ammonia, nitrates etc. A combination of IAWQ#1 module with the Takacs module gave best results for the existing scenarios of the Titagarh Sewage Treatment Plant. The modified Bardenpho process was found most effective for reducing the mean b-COD level to as low as 31.4 mg/l, while the mean TSS level was as high as 100.98 mg/l as compared to the mean levels of TSS (92 62 mg/l) and b-COD (92.0 mg/l) in the existing plant. Scheme 2 gave a better scenario for the mean TSS level bringing it down to a mean value of 0.4 mg/l, but a higher mean value for the b-COD level at 54.89 mg/l. The Scheme Final could reduce the mean TSS level to 2.9 mg/l and the mean b-COD level to as low as 38.8 mg/l. The Final Scheme looks to be a technically viable scheme with respect to the overall effluent quality for the plant. (C) 2009 Elsevier B.V. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Lagoons have been traditionally used in India for decentralized treatment of domestic sewage. These are cost effective as they depend mainly on natural processes without any external energy inputs. This study focuses on the treatment efficiency of algae-based sewage treatment plant (STP) of 67.65 million liters per day (MLD) capacity considering the characteristics of domestic wastewater (sewage) and functioning of the treatment plant, while attempting to understand the role of algae in the treatment. STP performance was assessed by diurnal as well as periodic investigations of key water quality parameters and algal biota. STP with a residence time of 14.3 days perform moderately, which is evident from the removal of total chemical oxygen demand (COD) (60 %), filterable COD (50 %), total biochemical oxygen demand (BOD) (82 %), and filterable BOD (70 %) as sewage travels from the inlet to the outlet. Furthermore, nitrogen content showed sharp variations with total Kjeldahl nitrogen (TKN) removal of 36 %; ammonium N (NH4-N) removal efficiency of 18 %, nitrate (NO3-N) removal efficiency of 22 %, and nitrite (NO2-N) removal efficiency of 57.8 %. The predominant algae are euglenoides (in facultative lagoons) and chlorophycean members (maturation ponds). The drastic decrease of particulates and suspended matter highlights heterotrophy of euglenoides in removing particulates.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The present study was conducted to assess the potential toxicity of the effluent from a large sewage treatment plant (GBD-STP) in Beijing. Japanese medakas (Oryzias latipes) at reproduction active period were exposed to a serial of graded concentrations of the effluent or 100 ng l(-1) of 17-alpha-ethinylestradiol (EE2, positive control). Growth, gonadosomatic index (GSI), hepatosomatic index (HSI), reproductive success, induction potency of vitellogenin (VTG) in male fish and that of 7-ethoxyresorufin-o-deethylase activity (EROD) in male fish liver were used as test endpoints. The growth suppression of fish was observed in a dose-dependent manner, resulting in significant differences in both body length and body weight of medaka above 5% effluent. This effluent can inhibit the growth of gonad of medakas and are more sensitive to male than to female. At exposure concentration of 40% and higher, there was an unexpected decrease of HSI values, which may be resulted from sub-lethal toxicity of effluent to fish liver. VTG of plasma in males were induced in all exposure concentration levels, but not in a dose-dependent manner. The concentration of 5% effluent would be the lowest observed adverse effect level (LOAEL) affecting reproductive success when examining fertile individuals, fecundity and fertilization rate. The overt CYP1A response and higher reproductive toxicity may be indicative of low process efficiency of this STP. (c) 2004 Elsevier Ltd. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The cost of electricity, a major operating cost of municipal wastewater treatment plants, is related to influent flow rate, power price, and power load. With knowledge of inflow and price patterns, plant operators can manage processes to reduce electricity costs. Records of influent flow, power price, and load are evaluated for Blue Plains Advanced Wastewater Treatment Plant. Diurnal and seasonal trends are analyzed. Power usage is broken down among treatment processes. A simulation model of influent pumping, a large power user, is developed. It predicts pump discharge and power usage based on wet-well level. Individual pump characteristics are tested in the plant. The model accurately simulates plant inflow and power use for two pumping stations [R2 = 0.68, 0.93 (inflow), R2 =0.94, 0.91(power)]. Wet-well stage-storage relationship is estimated from data. Time-varying wet-well level is added to the model. A synthetic example demonstrates application in managing pumps to reduce electricity cost.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

An assessment of sewage workers' exposure to airborne cultivable bacteria, fungi and inhaled endotoxins was performed at 11 sewage treatment plants. We sampled the enclosed and unenclosed treatment areas in each plant and evaluated the influence of seasons (summer and winter) on bioaerosol levels. We also measured personal exposure to endotoxins of workers during special operation where a higher risk of bioaerosol inhalation was assumed. Results show that only fungi are present in significantly higher concentrations in summer than in winter (2331 +/- 858 versus 329 +/- 95 CFU m(-3)). We also found that there are significantly more bacteria in the enclosed area, near the particle grids for incoming water, than in the unenclosed area near the aeration basins (9455 +/- 2661 versus 2435 +/- 985 CFU m(-3) in summer and 11 081 +/- 2299 versus 2002 +/- 839 CFU m(-3) in winter). All bioaerosols were frequently above the recommended values of occupational exposure. Workers carrying out special tasks such as cleaning tanks were exposed to very high levels of endotoxins (up to 500 EU m(-3)) compared to routine work. The species composition and concentration of airborne Gram-negative bacteria were also studied. A broad spectrum of different species within the Pseudomonadaceae and the Enterobacteriaceae families were predominant in nearly all plants investigated. [Authors]

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Endocrine disrupting chemicals (EDCs) constitute a diverse group of chemical compounds which can alter endocrine function in exposed animals. Whilst most studies have focussed on exposure of wildlife to EDCs via aquatic routes, there is the potential for transfer into the terrestrial food chain through consumption of contaminated prey items developing in sewage sludge and waste water at sewage treatment works. In this study, we determine levels of EDCs in aerial insects whose larval stages develop on percolating filter beds at sewage treatment works. We compare absolute concentrations of known EDCs with those collected from aquatic environments not exposed to sewage effluent outflow. Our findings document for the first time that aerial invertebrates developing on sewage filter beds take up a range of chemicals thought to be incorporated from the sewage effluent, which act as endocrine disruptors. For two synthetic chemicals (17α-ethinylestradiol and butylated hydroxy aniline), concentrations were significantly higher in insects captured around percolating filter beds than sites over 2 km from the nearest sewage works. A number of species of insectivorous bats and birds, some of which are declining or threatened, use sewage works as principle foraging sites. We calculate approximate exposure levels for a species of bat known to forage within sewage works and suggest that further research is warranted to assess the ecological implications of consuming contaminated invertebrate prey

Relevância:

100.00% 100.00%

Publicador:

Resumo:

 The wide need for sewage treatment facilities at the township level across China implies an emerging niche market for water and sanitation developers, investors and financiers. However this potential market is difficult to enter with traditional financing and delivery methods, because township sewage features small amount, volatile quantity, geographically scattering, immature fee charging system, weak affordability, and lack of capacities. A group of concession sewage treatment projects collectively implemented by a private company in the Changsha County of Hunan Province under the so called ‘Changsha Model’ provided innovative solutions. This cases study first examined the portfolio approach in terms of multiple delivery method integration, technology, and centralized control system, and evaluated the replicability of the new model. Practices and lessons learned from the case were then presented and summarized that can be applied to the following township sewage treatment facility development. Last, the Changsha Model was compared with similar infrastructure portfolio delivery solutions applied in the US.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Photodegradation of the pharmaceuticals amoxicillin (AMX), bezafibrate (BZF) and paracetamol (PCT) in aqueous solutions via the photo-Fenton process was investigated under black-light and solar irradiation. The influences of iron source, initial H2O2 concentration and matrix (distilled water and sewage treatment plant effluent) on degradation efficiency were discussed in detail. The results showed that (i) the degradation of the drugs was favored in the presence of potassium ferrioxalate (FeOx) in comparison to Fe(NO3)(3): (ii) the increase of the H2O2 concentration improved the efficiency of AMX and BZF oxidation; however, the same was not observed for PCT: (iii) the influence of the matrix was observed for the degradation of BZF and PCT: (iv) under solar irradiation, the oxidation of the BZF and PCT is faster than under black-light irradiation. All these pharmaceuticals can be efficiently degraded employing the process evaluated. (C) 2008 Elsevier B.V. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The number of the cities with canalized water and sewage treatment stations has increased lately and consequently having in mind the great concern on environment preservation and the quality of the water used by society. However, these stations are nowadays causing another kind of problem: a huge quantity of sludge as residue. Due to the implication of the residue on the environment and, consequently, to human life quality, performing of an accurate investigation about the components of such sludge, as well as the thermal stability of this residue in the environment become necessary. This paper presents a study on sludge from water and sewage treatment station, as well as the thermal characterization of residue. Such study was performed through FTIR, atomic absorption, thermoanalytical (TG/DTG, DTA) techniques, that made it possible to observe that the main components of the sludge are clay, carbonates and organic substance, presenting a low rate of metals and a unique thermal behavior since the sludge from the treatment station has a higher thermal stability.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

First, the effect of ferrioxalate or iron nitrate on the photo-Fenton degradation efficiency of the pharmaceuticals lincomycin (LCM) and diazepam (DZP) was evaluated. The degradation of both pharmaceuticals was improved in the presence of ferrioxalate in relation to Fe(NO(3)), either under black-light or solar irradiation. The degradation of the pharmaceuticals was then evaluated when present in an effluent from sewage treatment plant (STP) under black-light irradiation. Pharmaceuticals oxidation was not influenced by the matrix, since very similar results were obtained when compared to the experiments carried out in distilled water. However, DOC removal was slightly affected by the matrix, due probably to the generation of recalcitrant intermediates during effluent photodegradation and to the high content of inorganic carbon of STP effluent. Even so, high DOC removal percentages were achieved, 65% for lincomycin and 80% for diazepam after 60 min irradiation. (C) 2010 Elsevier B.V. All rights reserved.