954 resultados para Minimally invasisve


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Pectus excavatum is the most common deformity of the thorax. A minimally invasive surgical correction is commonly carried out to remodel the anterior chest wall by using an intrathoracic convex prosthesis in the substernal position. The process of prosthesis modeling and bending still remains an area of improvement. The authors developed a new system, i3DExcavatum, which can automatically model and bend the bar preoperatively based on a thoracic CT scan. This article presents a comparison between automatic and manual bending. The i3DExcavatum was used to personalize prostheses for 41 patients who underwent pectus excavatum surgical correction between 2007 and 2012. Regarding the anatomical variations, the soft-tissue thicknesses external to the ribs show that both symmetric and asymmetric patients always have asymmetric variations, by comparing the patients’ sides. It highlighted that the prosthesis bar should be modeled according to each patient’s rib positions and dimensions. The average differences between the skin and costal line curvature lengths were 84 ± 4 mm and 96 ± 11 mm, for male and female patients, respectively. On the other hand, the i3DExcavatum ensured a smooth curvature of the surgical prosthesis and was capable of predicting and simulating a virtual shape and size of the bar for asymmetric and symmetric patients. In conclusion, the i3DExcavatum allows preoperative personalization according to the thoracic morphology of each patient. It reduces surgery time and minimizes the margin error introduced by the manually bent bar, which only uses a template that copies the chest wall curvature.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Pectus carinatum (PC) is a chest deformity caused by a disproportionate growth of the costal cartilages compared to the bony thoracic skeleton, pulling the sternum towards, which leads to its protrusion. There has been a growing interest on using the ‘reversed Nuss’ technique as minimally invasive procedure for PC surgical correction. A corrective bar is introduced between the skin and the thoracic cage and positioned on top of the sternum highest protrusion area for continuous pressure. Then, it is fixed to the ribs and kept implanted for about 2–3 years. The purpose of this work was to (a) assess the stresses distribution on the thoracic cage that arise from the procedure, and (b) investigate the impact of different positioning of the corrective bar along the sternum. The higher stresses were generated on the 4th, 5th and 6th ribs backend, supporting the hypothesis of pectus deformities correction-induced scoliosis. The different bar positioning originated different stresses on the ribs’ backend. The bar position that led to lower stresses generated on the ribs backend was the one that also led to the smallest sternum displacement. However, this may be preferred, as the risk of induced scoliosis is lowered.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Pectus excavatum is the most common deformity of the thorax. A minimally invasive surgical correction is commonly carried out to remodel the anterior chest wall by using an intrathoracic convex prosthesis in the substernal position. The process of prosthesis modeling and bending still remains an area of improvement. The authors developed a new system, i3DExcavatum, which can automatically model and bend the bar preoperatively based on a thoracic CT scan. This article presents a comparison between automatic and manual bending. The i3DExcavatum was used to personalize prostheses for 41 patients who underwent pectus excavatum surgical correction between 2007 and 2012. Regarding the anatomical variations, the soft-tissue thicknesses external to the ribs show that both symmetric and asymmetric patients always have asymmetric variations, by comparing the patients’ sides. It highlighted that the prosthesis bar should be modeled according to each patient’s rib positions and dimensions. The average differences between the skin and costal line curvature lengths were 84 ± 4 mm and 96 ± 11 mm, for male and female patients, respectively. On the other hand, the i3DExcavatum ensured a smooth curvature of the surgical prosthesis and was capable of predicting and simulating a virtual shape and size of the bar for asymmetric and symmetric patients. In conclusion, the i3DExcavatum allows preoperative personalization according to the thoracic morphology of each patient. It reduces surgery time and minimizes the margin error introduced by the manually bent bar, which only uses a template that copies the chest wall curvature.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Children may benefit from minimally invasive surgery (MIS) in the correction of Morgagni hernia (MH). The present study aims to evaluate the outcome of MIS through a multicenter study. National institutions that use MIS in the treatment of MH were included. Demographic, clinical and operative data were analyzed. Thirteen patients with MH (6 males) were operated using similar MIS technique (percutaneous stitches) at a mean age of 22.2±18.3 months. Six patients had chromosomopathies (46%), five with Down syndrome (39%). Respiratory complaints were the most common presentation (54%). Surgery lasted 95±23min. In none of the patients was the hernia sac removed; prosthesis was never used. In the immediate post-operative period, 4 patients (36%) were admitted to intensive care unit (all with Down syndrome); all patients started enteral feeds within the first 24h. With a mean follow-up of 56±16.6 months, there were two recurrences (18%) at the same institution, one of which was repaired with an absorbable suture; both with Down syndrome. The application of MIS in the MH repair is effective even in the presence of comorbidities such as Down syndrome; the latter influences the immediate postoperative recovery and possibly the recurrence rate. Removal of hernia sac does not seem necessary. Non-absorbable sutures may be more appropriate.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Despite advertising for NOTES in 2009, single trocart laparoscopic surgery is about to become a new standard in selected indications. As other important topics, the limits of oncological surgery are extended due to a systematic multidisciplinary approach. To discuss every publication would be difficult and our review will focus on a selected number of papers of importance for daily practice. As examples, the management of acute calculous cholecystitis, gastro-esophageal reflux, inguinal and incisional hernia repair as well as colorectal surgery are presented.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Insight into the function of sleep may be gained by studying animals in the ecological context in which sleep evolved. Until recently, technological constraints prevented electroencephalogram (EEG) studies of animals sleeping in the wild. However, the recent development of a small recorder (Neurologger 2) that animals can carry on their head permitted the first recordings of sleep in nature. To facilitate sleep studies in the field and to improve the welfare of experimental animals, herein, we test the feasibility of using minimally invasive surface and subcutaneous electrodes to record the EEG in barn owls. The EEG and behaviour of four adult owls in captivity and of four chicks in a nest box in the field were recorded. We scored a 24-h period for each adult bird for wakefulness, slow-wave sleep (SWS), and rapid-eye movement (REM) sleep using 4 s epochs. Although the quality and stability of the EEG signals recorded via subcutaneous electrodes were higher when compared to surface electrodes, the owls' state was readily identifiable using either electrode type. On average, the four adult owls spent 13.28 h awake, 9.64 h in SWS, and 1.05 h in REM sleep. We demonstrate that minimally invasive methods can be used to measure EEG-defined wakefulness, SWS, and REM sleep in owls and probably other animals.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Atrial fibrillation (AF) is a frequent arrhythmia after conventional coronary artery bypass grafting. With the advent of minimally invasive technique for left internal mammary artery-left anterior descending coronary artery (LIMA-LAD) grafting, we analyzed the incidence and the risk factors of postoperative AF in this patient population. This prospective study involves all patients undergoing isolated LIMA-LAD grafting with minimally invasive technique between January 1994 and June 2000. Twenty-four possible risk factors for postoperative AF were entered into univariate and multivariate logistic regression analyses. Postoperative AF occurred in 21 of the 90 patients (23.3%) analyzed. Double- or triple-vessel disease was present in 12/90 patients (13.3%). On univariate analysis, right coronary artery disease (p <0.01), age (p = 0.01), and diabetes (p = 0.04) were found to be risk factors for AF. On multivariate analysis, right coronary artery disease was identified as the sole significant risk factor (p = 0.02). In this patient population, the incidence of AF after minimally invasive coronary artery bypass is in the range of that reported for conventional coronary artery bypass grafting. Right coronary artery disease was found to be an independent predictor, and this may be related to the fact that in this patient population the diseased right coronary artery was not revascularized at the time of the surgical procedure. For the same reason, this risk factor may find a broader application to noncardiac thoracic surgery.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: In large randomized multicenter trials, ranibizumab has shown its therapeutic efficacy for exudative age-related macular degeneration (AMD). The aim of this paper is to report the real-life clinical experience with this treatment for occult and minimally classic membranes without pigment epithelium detachment. METHODS: We conducted a retrospective chart review of 37 patients with occult and minimally classic neovascular membranes in AMD, without pigment epithelium detachment. RESULTS: The mean visual improvement of 2 lines at 3, 6 and 9 months corresponds well with the results of the large trials. A mean number of 5 reinjections was reached by month 8. It may potentially exceed the mean 5.5 injections of the PrONTO study (prospective optical coherence tomography imaging of patients with neovascular AMD treated with intraocular ranibizumab). At months 6-8 recurrence was frequently observed. CONCLUSION: The early experience of ranibizumab in clinical practice brings similarly good results as the large-scale trials. However, interrupting the treatment too early may be a disadvantage.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

There is an ever-growing trend towards less-invasive procedures in all fields of medicine. We designed an animal study to prove the concept that trans-apical aortic valve replacement from an incision within the umbilicus through a single channel for instruments is feasible, which would be a major leap towards no-scar cardiac surgery. In three adult pigs, after creating a single 3-cm incision at a place where the human umbilicus would be, we introduced a 30F sheath through a tunnel created by an endoscopic vein-harvesting device up to the cardiac apex, through it and up to the left ventricle simulating the approach for trans-apical aortic valve replacement. We used a standard Amplatz nitinol occluder to seal the defect in ventricle wall later. The animals were followed up for 1h. Blood loss was minimal, and no tamponade occurred in any of the animals. In addition, we performed a test with water column static pressure to evaluate the impact of preclotting on the sealing properties of the occluders: 1 min flow-through was 2860+/-176 ml for the standard occluders and 348+/-56 ml for preclotted occluders (p<0.001).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We describe a simple method to achieve both hemostasis and stabilization of the left anterior descending coronary artery during minimally invasive coronary artery bypass grafting. This technique allows the surgeon to perform a precise anastomosis of the left internal mammary artery to the target vessel on a beating heart.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: Minimally invasive surgery (MIS) for late-presenting congenital diaphragmatic hernia (CDH) has been described previously, but few neonatal cases of CDH have been reported. This study aimed to report the multicenter experience of these rare cases and to compare the laparoscopic and thoracoscopic approaches. METHODS: Using MIS procedures, 30 patients (16 boys and 14 girls) from nine centers underwent surgery for CDH within the first month of life, 26 before day 5. Only one patient had associated malformations. There were 10 preterm patients (32-36 weeks of gestational age). Their weight at birth ranged from 1,800 to 3,800 g, with three patients weighing less than 2,600 g. Of the 30 patients, 18 were intubated at birth. RESULTS: The MIS procedures were performed in 18 cases by a thoracoscopic approach and in 12 cases by a laparoscopic approach. No severe complication was observed. For 20 patients, reduction of the intrathoracic contents was achieved easily with 15 thoracoscopies and 5 laparoscopies. In six cases, the reduction was difficult, proving to be impossible for the four remaining patients: one treated with thoracoscopy and three with laparoscopy. The reasons for the inability to reduce the thoracic contents were difficulty of liver mobilization (1 left CDH and 2 right CDH) and the presence of a dilated stomach in the thorax. Reductions were easier for cases of wide diaphragmatic defects using thoracoscopy. There were 10 conversions (5 laparoscopies and 5 thoracoscopies). The reported reasons for conversion were inability to reduce (n = 4), need for a patch (n = 5), lack of adequate vision (n = 4), narrow working space (n = 1), associated bowel malrotation (n = 1), and an anesthetic problem (n = 1). Five defects were too large for direct closure and had to be closed with a patch. Four required conversion, with one performed through video-assisted thoracic surgery. The recurrences were detected after two primer thoracoscopic closures, one of which was managed by successful reoperation using thoracoscopy. CONCLUSIONS: In the neonatal period, CDH can be safely closed using MIS procedures. The overall success rate in this study was 67%. The indication for MIS is not related to weeks of gestational age, to weight at birth (if >2,600 g), or to the extent of the immediate neonatal care. Patients with no associated anomaly who are hemodynamically stabilized can benefit from MIS procedures. Reduction of the herniated organs is easier using thoracoscopy. Right CDH, liver lobe herniation, and the need for a patch closure are the most frequent reasons for conversion.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Thyroid and parathyroid surgery takes an important place in general surgery. Preservation of essential cervical structures and cosmetic of outcomes of cervical incisions are major concern. Several minimally invasive strategies have been developed recently but their acceptance in the surgical community is low. Their main advantages are focused tissue dissection and improved cosmetics. In this review, management and surgical indications of thyroid nodules and parathyroid adenomas are discussed. The various minimally invasive techniques are described and their current indications are reviewed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: The aim of our study was to assess the feasibility of minimally invasive digestive anastomosis using a modular flexible magnetic anastomotic device made up of a set of two flexible chains of magnetic elements. The assembly possesses a non-deployed linear configuration which allows it to be introduced through a dedicated small-sized applicator into the bowel where it takes the deployed form. A centering suture allows the mating between the two parts to be controlled in order to include the viscerotomy between the two magnetic rings and the connected viscera. METHODS AND PROCEDURES: Eight pigs were involved in a 2-week survival experimental study. In five colorectal anastomoses, the proximal device was inserted by a percutaneous endoscopic technique, and the colon was divided below the magnet. The distal magnet was delivered transanally to connect with the proximal magnet. In three jejunojejunostomies, the first magnetic chain was injected in its linear configuration through a small enterotomy. Once delivered, the device self-assembled into a ring shape. A second magnet was injected more distally through the same port. The centering sutures were tied together extracorporeally and, using a knot pusher, magnets were connected. Ex vivo strain testing to determine the compression force delivered by the magnetic device, burst pressure of the anastomosis, and histology were performed. RESULTS: Mean operative time including endoscopy was 69.2 ± 21.9 min, and average time to full patency was 5 days for colorectal anastomosis. Operative times for jejunojejunostomies were 125, 80, and 35 min, respectively. The postoperative period was uneventful. Burst pressure of all anastomoses was ≥ 110 mmHg. Mean strain force to detach the devices was 6.1 ± 0.98 and 12.88 ± 1.34 N in colorectal and jejunojejunal connections, respectively. Pathology showed a mild-to-moderate inflammation score. CONCLUSIONS: The modular magnetic system showed enormous potential to create minimally invasive digestive anastomoses, and may represent an alternative to stapled anastomoses, being easy to deliver, effective, and low cost.