808 resultados para Middle-ear


Relevância:

100.00% 100.00%

Publicador:

Resumo:

OBJECTIVE: To generate anatomical data on the human middle ear and adjacent structures to serve as a base for the development and optimization of new implantable hearing aid transducers. Implantable middle ear hearing aid transducers, i.e. the equivalent to the loudspeaker in conventional hearing aids, should ideally fit into the majority of adult middle ears and should utilize the limited space optimally to achieve sufficiently high maximal output levels. For several designs, more anatomical data are needed. METHODS: Twenty temporal bones of 10 formalin-fixed adult human heads were scanned by a computed tomography system (CT) using a slide thickness of 0.63 mm. Twelve landmarks were defined and 24 different distances were calculated for each temporal bone. RESULTS: A statistical description of 24 distances in the adult human middle ear which may limit or influence the design of middle ear transducers is presented. Significant inter-individual differences but no significant differences for gender, side, age or degree of pneumatization of the mastoid were found. Distances, which were not analyzed for the first time in this study, were found to be in good agreement with the results of earlier studies. CONCLUSION: A data set describing the adult human middle ear anatomy quantitatively from the point of view of designers of new implantable hearing aid transducers has been generated. In principle, the method employed in this study using standard CT scans could also be used preoperatively to rule out exclusion criteria.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A life-size mechanical middle ear model and human temporal bones were used to evaluate three different middle ear transducers for implantable hearing aids: the driving rod transducer (DRT), the floating mass transducer (FMT) or vibrant sound bridge, and the contactless transducer (CLT). Results of the experiments with the mechanical model were within the range of the results for human temporal bones. However, results with the mechanical model showed better reproducibility. The handling of the mechanical model was considerably simpler and less time-consuming. Systematic variations of mounting parameters showed that the angle of the rod has virtually no effect on the output of the DRT, the mass loading on the cable of the FMT has a larger impact on the output than does the tightness of crimping, and the output level of the CLT can be increased by 10 dB by optimizing the mounting parameters.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This paper presents a case of a 28-year-old male with a seizure episode and a 4-year history of intermittent tinnitus on the left ear. On computed tomography and magnetic resonance imaging, a density with rim enhancement was found at the temporal lobe, associated with mastoid tegmen destruction and middle ear mass, indicating cholesteatoma with complicating brain abscess. Evacuation of the brain abscess was performed with a combined otolaryngologic and neurosurgical procedures (canal wall-down mastoidectomy and temporal craniotomy). The pathology turned out to be infestation with Echinococcus granulosus.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Thiel-embalmed human whole-head specimens offer a promising alternative model for bone conduction (BC) studies of middle ear structures. In this work we present the Thiel model’s linearity and stability over time as well as its possible use in the study of a fixed ossicle chain. Using laser Doppler vibrometry (LDV), the motion of the retroauricular skull, the promontory, the stapes footplate and the round window (RW) were measured. A bone-anchored hearing aid stimulated the ears with step sinus tones logarithmically spread between 0.1 and 10 kHz. Linearity of the model was verified using input levels in steps of 10 dBV. The stability of the Thiel model over time was examined with measurements repeated after hours and weeks. The influence of a cement-fixed stapes was assessed. The middle ear elements measured responded linearly in amplitude for the applied input levels (100, 32.6, and 10 mV). The variability of measurements for both short- (2 h) and long-term (4-16 weeks) repetitions in the same ear was lower than the interindividual difference. The fixation of the stapes induced a lowered RW displacement for frequencies near 750 Hz (-4 dB) and an increased displacement for frequencies above 1 kHz (max. +3.7 dB at 4 kHz). LDV assessment of BC-induced middle ear motion in Thiel heads can be performed with stable results. The vibratory RW response is affected by the fixation of the stapes, indicating a measurable effect of ossicle chain inertia on BC response in Thiel embalmed heads.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Many passengers experience discomfort during flight because of the effect of low humidity on the skin, eyes, throat, and nose. In this physiological study, we have investigated whether flight and low humidity also affect the tympanic membrane. From previous studies, a decrease in admittance of the tympanic membrane through drying might be expected to affect the buffering capacity of the middle ear and to disrupt automatic pressure regulation. This investigation involved an observational study onboard an aircraft combined with experiments in an environmental chamber, where the humidity could be controlled but could not be made to be as low as during flight. For the flight study, there was a linear relationship between the peak compensated static admittance of the tympanic membrane and relative humidity with a constant of proportionality of 0.00315 mmho/% relative humidity. The low humidity at cruise altitude (minimum 22.7 %) was associated with a mean decrease in admittance of about 20 % compared with measures in the airport. From the chamber study, we further found that a mean decrease in relative humidity of 23.4 % led to a significant decrease in mean admittance by 0.11 mmho [F(1,8) = 18.95, P = 0.002], a decrease of 9.4 %. The order of magnitude for the effect of humidity was similar for the flight and environmental chamber studies. We conclude that admittance changes during flight were likely to have been caused by the low humidity in the aircraft cabin and that these changes may affect the automatic pressure regulation of the middle ear during descent. © 2013 Association for Research in Otolaryngology.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

OBJECTIVE: To record with video-otoscopy the appearance of the tympanic membranes of a cross section of children aged 9 to 10 years. STUDY DESIGN: Cross-sectional study nested within an established longitudinal study of childhood development, the Avon Longitudinal Study of Parents and Children. SETTING: South West England, U.K. PARTICIPANTS: Approximately 6908 of 7261 children with ages ranging from 105 to 140 months born between April 1, 1991, and December 31, 1992, were examined by trained technicians with video-otoscopy. MAIN OUTCOME MEASURES: Two photographs were taken of each child's tympanic membranes to show the features of the pars tensa and the pars flaccida. RESULTS: In just less than three quarters of the children, both ears were normal. Retraction of the pars flaccida was present in 9.6% of children, and that of the pars tensa was present in 7.9%. Most of these changes were mild with few severe retractions. There were 15 cases of overt or suspected cholesteatoma. CONCLUSION: The tympanic membrane changes reflect most of the middle ear disease seen in 9- to 10-year-old children. The prevalence is low, and few children have serious disease at this stage.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Objectifs: Le Nystatin est un antibiotique efficace pour le traitement d’otomycose. Bien que sa sécurité au niveau de l’oreille externe soit bien établie, son utilisation n’est pas recommandée lorsqu’il y a une perforation tympanique. L’objectif de cette étude est d’évaluer le potentiel ototoxique du Nystatin lorsque celui-ci est appliqué directement au niveau de l’oreille moyenne. Méthodes: Nous avons fait une étude expérimentale avec 18 cochons d’Indes de souche Hartley que nous avons divisés en deux groupes. En exposant l’oreille moyenne de chaque animal au Nystatin (groupe I) ou à la néomycine (groupe II) et chaque oreille controlatérale à une solution physiologique (NaCl), la fonction auditive a été évaluée avec un test de potentiels évoqués auditif du tronc cérébral avant et après les injections. Une étude par microscopie électronique a permis une comparaison histologique de l’état des cellules ciliées cochléaires entre les 2 groupes. Résultats: Les pertes auditives moyennes du groupe « Nystatin » étaient de 13.0 dB et comparables aux pertes moyennes observées dans les oreilles ayant été injectées avec du NaCl (4.0 dB dans le groupe I et 15.1 dB dans le groupe II). Le groupe de contrôle « néomycine » a subi une perte auditive moyenne de 39.3 dB, ce qui représente une différence cliniquement et statistiquement significative (p<0.001). L’étude histologique avec une microscopie à balayage électronique a démontré une conservation de l’architecture des cellules ciliées cochléaires dans les groupe Nystatin et NaCl. La néomycine a causé une destruction marquée de ces structures. Conclusions: Le Nystatin ne provoque pas d’atteinte auditive ni de destruction des cellules ciliées externes après injection directe dans l’oreille moyenne chez le cochon d’Inde.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Clinically healthy mixed breed dogs (n = 20) were used to determine if a Tris (tromethamine)-buffered test solution, Otinide((R)) (Trademark of Dermcare-Vet Pty-Ltd, Australia), containing disodium ethylenediamine tetraacetic acid (EDTA; 1.21 g/L) and polyhexamethylene biguanide (PHMB; 0.22 g/L) caused ototoxicity or vestibular dysfunction. The dogs were randomly assigned to either a control group (group A, n = 10) receiving saline, or a treatment group (group B, n = 10) receiving the test solution. Phase 1 of the study consisted of applying 5.0 mL of saline to both ears of the control group (group A) and 5 mL of test solution to both ears of the test group (group B), for 21 days. A bilateral myringotomy was then performed on each dog under deep sedation. Phase 2 of the study then consisted of applying 2.0 mL of the saline to both ears of the control group (group A) and 2.0 mL of the test solution to both ears of the test group (group B), for 14 days. Throughout the study, dogs were examined for clinical health, and underwent otoscopic, vestibular and auditory examinations. The auditory examinations included brainstem auditory evoked potential (BAEP) threshold and supra-threshold assessments using both click and 8 kHz tone burst stimuli. The absence of vestibular signs and effects on the BAEP attributable to the test solution suggested the test solution could be applied safely to dogs, including those with a damaged tympanic membrane.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

OBJETIVO: descrever as características audiológicas de indivíduos com fissura labiopalatina operada (FLP) e indicação de cirurgia otológica, comparando os grupos quanto ao tipo e grau da perda auditiva, bem como a curva timpanométrica. MÉTODOS: análise de 150 prontuários, ambos os gêneros, idade igual ou superior a 4 anos, FLP e indicação de cirurgia otológica, divididos em 3 grupos: I - Tubo de ventilação (TV), II - Timpanoplastia e III - Timpanomastoidectomia, analisando aspectos quanto a entrevista audiológica, audiometria tonal limiar e imitanciometria. RESULTADOS: o grupo I apresentou porcentagem maior de cirurgia bilateral (86%), o que não ocorreu nos demais grupos. Na entrevista audiológica, 83% apresentou algum tipo de queixa auditiva, sendo a mais frequente a perda auditiva (64%) com p<0,05 entre os grupos I e II; I e III. O tipo de perda auditiva de maior ocorrência foi condutivo bilateral (56%) seguido de unilateral (35%), com p<0,05 entre os grupos I e II; I e III. A perda de grau leve unilateral foi a de maior ocorrência (41%), seguida de grau leve a moderada bilateral (20%), com p<0,05 entre os três grupos. A curva timpanométrica mais frequente foi a do tipo B bilateral (39%) com p<0,05 entre os três grupos. CONCLUSÃO: a maioria dos indivíduos apresentou algum tipo de queixa na entrevista audiológica e alterações na audiometria tonal limiar e imitanciometria. A maioria dessas alterações foi compatível com problemas de orelha média, com perda auditiva do tipo condutiva, de grau leve e bilateral, independentemente da indicação cirúrgica.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The characteristics of high frequency (1000 Hz) acoustic admittance results obtained from normal neonates were described in this study. Participants were 170 healthy neonates (96 boys and 74 girls) aged between 1 and 6 days (mean = 3.26 days, SD = 0.92). Transient evoked otoacoustic emissions (TEOAEs), and 226 Hz and 1000 Hz probe tone tympanograms were obtained from the participants using a Madsen Capella OAE/middle ear analyser. The results showed that of the 170 neonates, 34 were not successfully tested in both ears, 14 failed the TEOAE screen in one or both ears, and 122 (70 boys, 52 girls) passed the TEOAE screen in both ears and also maintained an acceptable probe seal during tympanometry. The 1000 Hz tympanometric data for the 122 neonates (244 ears) showed a single-peaked tympanogram in 225 ears (92.2 %), a flat-sloping tympanogram in 14 ears (5.7 %), a double-peaked tympanogram in 3 ears (1.2 %) and other unusual shapes in 2 ears (0.8 %). There was a significant ear effect, with right ears showing significantly higher mean peak compensated static admittance and tympanometric width, but lower mean acoustic admittance at +200 daPa and gradient than left ears. No significant gender effects or its interaction with ear were found. The normative tympanometric data derived from this cohort may serve as a guide for detecting middle ear dysfunction in neonates.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

This study examined the test performance of distortion product otoacoustic emissions (DPOAEs) when used as a screening tool in the school setting. A total of 1003 children (mean age 6.2 years, SD = 0.4) were tested with pure-tone screening, tympanometry, and DPOAE assessment. Optimal DPOAE test performance was determined in comparison with pure-tone screening results using clinical decision analysis. The results showed hit rates of 0.86, 0.89, and 0.90, and false alarm rates of 0.52, 0.19, and 0.22 for criterion signal-to-noise ratio (SNR) values of 4, 5, and 11 dB at 1.1, 1.9, and 3.8 kHz respectively. DPOAE test performance was compromised at 1.1 kHz. In view of the different test performance characteristics across the frequencies, the use of a fixed SNR as a pass criterion for all frequencies in DPOAE assessments is not recommended. When compared to pure tone plus tympanometry results, the DPOAEs showed deterioration in test performance, suggesting that the use of DPOAEs alone might miss children with subtle middle ear dysfunction. However, when the results of a test protocol, which incorporates both DPOAEs and tympanometry, were used in comparison with the gold standard of pure-tone screening plus tympanometry, test performance was enhanced. In view of its high performance, the use of a protocol that includes both DPOAEs and tympanometry holds promise as a useful tool in the hearing screening of schoolchildren, including difficult-to-test children.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Abnormalities in craniofacial morphology are associated with Eustachian tube dysfunction and otitis media with effusion (OME). Aim: to evaluate the relationship between facial pattern and craniofacial growth direction, and OME in children with enlarged tonsils and adenoids (ETA). Methods: Clinical prospective survey in 79 children (41 male and 38 female), ranging from 4 to 10 years of age, with tonsil and adenoid enlargement (Brodsky`s grades III and IV). Forty children presented with OME (study group) and 39 did not (control group). Cephalometric analysis was used to determine the facial pattern. Results: There was no correlation observed between facial pattern and OME (c 2 = 0.25 p = 0.88). Facial Axis was larger in the OME group (F(1.75) = 3.68 p = 0.05) and the Lower Anterior Facial height was smaller (F(1. 75) = 3.99 p = 0.05) in children with otitis media with effusion. Conclusions: There was no correlation between OME and facial pattern in children with ETA although a more horizontal facial growth direction, and a smaller lower anterior facial height was observed consistently among subjects in this group. This suggests that abnormal positioning of the eustachian tube influences the development of OME in children with ETA.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Pop-rock musicians are at risk of developing hearing loss and other symptoms related to amplified music. Aim: The aim of the present study was to assess the satisfaction provided by the use of hearing protection in pop-rock musicians. Study design: Contemporary cohort study. Materials and Methods: A study of 23 male pop-rock musicians, aged between 25 to 45 years. After audiological evaluation (pure tone audiometry, middle ear analysis, TEOAE and DPOAE) hearing protective devices were provided to be used for three months. After that musicians answered a satisfaction assessment questionnaire. Results: The prevalence of hearing loss was of 21.7%. The most common complaints about the hearing protectors were: autophonia, pressure in the ears, interference in high frequencies perception and full time use of the hearing protector during concerts. There was a positive correlation between a reduction in tinnitus after the use of the HPD with the following complaints: tinnitus after beginning the career (p=0.044), discomfort with the sound intensity in the work place (p=0.009) and intolerance to loud sound (p=0.029). Conclusions: There was a high prevalence of hearing loss and a positive tendency towards the use of the ear protector device among the sample population.