949 resultados para Measurement method


Relevância:

70.00% 70.00%

Publicador:

Resumo:

Although there are numerous accurate measuring methods to determine soil moisture content in a spot, until very recently there were no precise in situ and in real time methods that were able to measure soil moisture content along a line. By means of the Distributed Fiber Optic Temperature Measurement method or DFOT, the temperature in 0.12 m intervals and long distances (up to 10,000 m) with a high time frequency and an accuracy of +0.2º C is determined. The principle of temperature measurement along a fiber optic cable is based on the thermal sensitivity of the relative intensities of backscattered photons that arise from collisions with electrons in the core of the glass fiber. A laser pulse, generated by the DTS unit, traversing a fiber optic cable will result in backscatter at two frequencies. The DTS quantifies the intensity of these backscattered photons and elapsed time between the pulse and the observed returned light. The intensity of one of the frequencies is strongly dependent on the temperature at the point where the scattering process occurred. The computed temperature is attributed to the position along the cable from which the light was reflected, computed from the time of travel for the light.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Clusters are aggregations of atoms or molecules, generally intermediate in size between individual atoms and aggregates that are large enough to be called bulk matter. Clusters can also be called nanoparticles, because their size is on the order of nanometers or tens of nanometers. A new field has begun to take shape called nanostructured materials which takes advantage of these atom clusters. The ultra-small size of building blocks leads to dramatically different properties and it is anticipated that such atomically engineered materials will be able to be tailored to perform as no previous material could.^ The idea of ionized cluster beam (ICB) thin film deposition technique was first proposed by Takagi in 1972. It was based upon using a supersonic jet source to produce, ionize and accelerate beams of atomic clusters onto substrates in a vacuum environment. Conditions for formation of cluster beams suitable for thin film deposition have only recently been established following twenty years of effort. Zinc clusters over 1,000 atoms in average size have been synthesized both in our lab and that of Gspann. More recently, other methods of synthesizing clusters and nanoparticles, using different types of cluster sources, have come under development.^ In this work, we studied different aspects of nanoparticle beams. The work includes refinement of a model of the cluster formation mechanism, development of a new real-time, in situ cluster size measurement method, and study of the use of ICB in the fabrication of semiconductor devices.^ The formation process of the vaporized-metal cluster beam was simulated and investigated using classical nucleation theory and one dimensional gas flow equations. Zinc cluster sizes predicted at the nozzle exit are in good quantitative agreement with experimental results in our laboratory.^ A novel in situ real-time mass, energy and velocity measurement apparatus has been designed, built and tested. This small size time-of-flight mass spectrometer is suitable to be used in our cluster deposition systems and does not suffer from problems related to other methods of cluster size measurement like: requirement for specialized ionizing lasers, inductive electrical or electromagnetic coupling, dependency on the assumption of homogeneous nucleation, limits on the size measurement and non real-time capability. Measured ion energies using the electrostatic energy analyzer are in good accordance with values obtained from computer simulation. The velocity (v) is measured by pulsing the cluster beam and measuring the time of delay between the pulse and analyzer output current. The mass of a particle is calculated from m = (2E/v$\sp2).$ The error in the measured value of background gas mass is on the order of 28% of the mass of one N$\sb2$ molecule which is negligible for the measurement of large size clusters. This resolution in cluster size measurement is very acceptable for our purposes.^ Selective area deposition onto conducting patterns overlying insulating substrates was demonstrated using intense, fully-ionized cluster beams. Parameters influencing the selectivity are ion energy, repelling voltage, the ratio of the conductor to insulator dimension, and substrate thickness. ^

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Much of the bridge stock on major transport links in North America and Europe was constructed in the 1950s and 1960s and has since deteriorated or is carrying loads far in excess of the original design loads. Structural Health Monitoring Systems (SHM) can provide valuable information on the bridge capacity but the application of such systems is currently limited by access and bridge type. This paper investigates the use of computer vision systems for SHM. A series of field tests have been carried out to test the accuracy of displacement measurements using contactless methods. A video image of each test was processed using a modified version of the optical flow tracking method to track displacement. These results have been validated with an established measurement method using linear variable differential transformers (LVDTs). The results obtained from the algorithm provided an accurate comparison with the validation measurements. The calculated displacements agree within 2% of the verified LVDT measurements, a number of post processing methods were then applied to attempt to reduce this error.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

The aim of the present study was to examine the effect of the systematic use of comics as a literary-didactic method to reduce gender differences in reading literacy and reading motivation at the primary level of education. It was assumed that the use of comics would have a positive effect on pupils’ reading literacy and reading motivation, while also reducing the aforementioned differences between boys and girls. The dimensions of reading literacy and reading motivation were examined in experimental and control groups, before and after the intervention, by means of questionnaires and tests for pupils. The sample consisted of 143 pupils from second to fifth grade from two Slovenian primary schools in a rural environment, of which 73 pupils participated in the experimental group and 70 pupils represented the control group. Effects of the use of comics as a literary-didactic method were not found: using comics as a literary-didactic method did not have a statistically significant effect on pupils’ reading literacy and reading motivation. However, when the four-way structure of the research (taking into account the age and gender of the pupils) was considered, some subgroups showed a statistically significant increase in reading interest and attitude towards reading. No reduction of gender differences in reading literacy and reading motivation was found. Based on the results, guidelines for further research are established and suggestions are offered for teachers’ work. (DIPF/Orig.)

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Adhesive bonding has become more efficient in the last few decades due to the adhesives developments, granting higher strength and ductility. On the other hand, natural fibre composites have recently gained interest due to the low cost and density. It is therefore essential to predict the fracture behavior of joints between these materials, to assess the feasibility of joining or repairing with adhesives. In this work, the tensile fracture toughness (Gc n) of adhesive joints between natural fibre composites is studied, by bonding with a ductile adhesive and co-curing. Conventional methods to obtain Gc n are used for the co-cured specimens, while for the adhesive within the bonded joint, the J-integral is considered. For the J-integral calculation, an optical measurement method is developed for the evaluation of the crack tip opening and adherends rotation at the crack tip during the test, supported by a Matlab sub-routine for the automated extraction of these quantities. As output of this work, an optical method that allows an easier and quicker extraction of the parameters to obtain Gc n than the available methods is proposed (by the J-integral technique), and the fracture behaviour in tension of bonded and co-cured joints in jute-reinforced natural fibre composites is also provided for the subsequent strength prediction. Additionally, for the adhesively- bonded joints, the tensile cohesive law of the adhesive is derived by the direct method.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Dissertação para obtenção do Grau de Mestre em Engenharia Electrotécnica e de Computadores

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The Stiles-Crawford effect (SCE) is the well-known phenomenon in which the brightness of light perceived by the human eye depends upon its entrance point in the pupil. This physiological characteristic is due to the directional sensitivity of the cone photoreceptors in the retina and it displays an approximately Gaussian dependency which is altered in a number of pathologies. Retinal imaging, a widely spread clinical practice, may be used to evaluate the SCE and thus serve as diagnostic tool. Nonetheless, its use for such a purpose is still underdeveloped and far from the clinical reality. In this project a fundus camera was built and used to assess the cone photoreceptor directionality by reflective imaging of the retina in healthy individuals. The physical and physiological implications of its development are addressed in detail in the text: the optical properties of the human eye, illumination issues, acquiring a retinal image formed by the eye, among others. A full description of the developmental process that led to the final measuring method and results is also given. The developed setup was successfully used to obtain high quality images of the eye fundus and in particular the parafoveal cone photoreceptors. The SCE was successfully observed and characterized. Even though considerable improvements could be done to the measurement method, the project showed the feasibility of using retinal imaging to evaluate the SCE thus motivating its usage in a clinical environment.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

One of the major challenges in the development of an immersive system is handling the delay between the tracking of the user’s head position and the updated projection of a 3D image or auralised sound, also called end-to-end delay. Excessive end-to-end delay can result in the general decrement of the “feeling of presence”, the occurrence of motion sickness and poor performance in perception-action tasks. These latencies must be known in order to provide insights on the technological (hardware/software optimization) or psychophysical (recalibration sessions) strategies to deal with them. Our goal was to develop a new measurement method of end-to-end delay that is both precise and easily replicated. We used a Head and Torso simulator (HATS) as an auditory signal sensor, a fast response photo-sensor to detect a visual stimulus response from a Motion Capture System, and a voltage input trigger as real-time event. The HATS was mounted in a turntable which allowed us to precisely change the 3D sound relative to the head position. When the virtual sound source was at 90º azimuth, the correspondent HRTF would set all the intensity values to zero, at the same time a trigger would register the real-time event of turning the HATS 90º azimuth. Furthermore, with the HATS turned 90º to the left, the motion capture marker visualization would fell exactly in the photo-sensor receptor. This method allowed us to precisely measure the delay from tracking to displaying. Moreover, our results show that the method of tracking, its tracking frequency, and the rendering of the sound reflections are the main predictors of end-to-end delay.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The interfacial micromotion is closely associated to the long-term success of cementless hip prostheses. Various techniques have been proposed to measure them, but only a few number of points over the stem surface can be measured simultaneously. In this paper, we propose a new technique based on micro-Computer Tomography (μCT) to measure locally the relative interfacial micromotions between the metallic stem and the surrounding femoral bone. Tantalum beads were stuck at the stem surface and spread at the endosteal surface. Relative micromotions between the stem and the endosteal bone surfaces were measured at different loading amplitudes. The estimated error was 10μm and the maximal micromotion was 60μm, in the loading direction, at 1400N. This pilot study provided a local measurement of the micromotions in the 3 direction and at 8 locations on the stem surface simultaneously. This technique could be easily extended to higher loads and a much larger number of points, covering the entire stem surface and providing a quasi-continuous distribution of the 3D interfacial micromotions around the stem. The new measurement method would be very useful to compare the induced micromotions of different stem designs and to optimize the primary stability of cementless total hip arthroplasty.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The MIT-Scan-T2 device is marketed as a non-destructive way to determine pavement thickness on both HMA and PCC pavements. PCC pavement thickness determination is an important incentivedisincentive measurement for the Iowa DOT and contractors. The thickness incentive can be as much as 3% of the concrete contact unit price and the disincentive can be as severe as remove and replace. This study evaluated the potential of the MIT device for PCC pavement thickness quality assurance. The limited testing indicates the unit is sufficiently repeatable and accurate enough to replace core drilling as the thickness measurement method. Further study is needed to statistically establish the single user and multi-user/device precision as well as establish an appropriate sampling protocol and PWL specification.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Hyötysuhde on tärkeätekijä moottorimarkkinoilla, sillä moottorin ostajan kannalta moottorin hyvä hyötysuhde merkitsee taloudellisuutta pitkällä aikavälillä. Tästä johtuen hyötysuhde on merkittävä kriteeri moottorisuunnittelussa. Moottorin hyötysuhteen määrittämisen mittausmenetelmät on määritelty IEC- ja IEEE-standardeissa. Diplomityössäkäydään läpi eri standardimenetelmillä tehtäviä mittauksia ja vertaillaan niitäkeskenään, koska hyötysuhteen määrityksen tarkkuus riippuu käytettävästä mittausmenetelmästä. Työssä keskitytään sinimuotoisella jännitteellä syötetyn induktiomoottoriin hyötysuhteen määritysmenetelmiin perehtyen erityisesti IEEE 112-standardin B-menetelmään, ja mitataan erään induktiomoottorin hyötysuhde B-menetelmällä. Työssä tehdään selkoa sinisyötölle tarkoitettujen hyötysuhdemittausmenetelmien soveltamisesta epäsinimuotoiseen taajuusmuuttajasyöttöön sekä tutkitaan taajuusmuuttajalla syötetyn moottorin sähköisten suureiden mittaamiseen liittyvää mittausepävarmuutta. Lisäksi selvitetään kokeellisesti taajuusmuuttajasyötöllä tehdyistä mittauksista saatujen tulosten riippuvuutta käytetystä virranmittaustavasta.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Tämän työn tarkoituksena oli tutkia pihkanhallintaa sulfaattisellutehtaalla ja uuteaineiden analysointimenetelmiä massasta ja suodoksesta. Tavoitteena oli kehittää uuteaineiden on-line mittausmenetelmä sulfaattisellutehtaalle. Kirjallisuusosassa esitettiin sulfaattisellun valmistusprosessi ja uuteaineiden käyttäytyminen prosessissa. Lisäksi työssä käsiteltiin tärkeimpiä pihkanhallintamenetelmiä ja uuteaineiden analysointia. Kokeellisessa osassa määritettiin uuteainepitoisuudet 29:stä massa- ja pesusuodosnäytteestä. Lisäksi suodosnäytteiden sameus ja kemiallinen hapenkulutus määritettiin laboratoriossa. On-line mittaukset tehtiin DD-pesurin paluusuodoksesta, josta mitattiin johtokyky, lämpötila, taitekerroin ja pH. Sameutta yritettiin mitata on-line nefelometrillä, mutta käytössä ollut laite ei soveltunut tumman suodoksen mittaamiseen. Työssä saatujen tulosten perusteella voidaan todeta, että pesusuodoksen ominaisuuksia mittaamalla ei voida arvioida massan uutepitoisuutta luotettavasti. Suodoksen ja massan uutepitoisuuksien välinen selitysaste oli 54%. Saippuoitumattomien uuteaineiden pitoisuuden ollessa erityisen suuri, suodoksen uutepitoisuus ei korreloi massassa olevan uutteen määrän kanssa. Täten kyseinen mittausmenetelmä ei ole sopiva, sillä se ei toimi silloin, kun olisi tärkeintä tietää oikea uuteainepitoisuus pihkanhallintakemikaalien annosten määrittämiseksi. Suodoksen sameus riippui sen uutepitoisuudesta 80% selitysasteella. Sameusmittaus on nopea ja suhteellisen luotettava menetelmä suodosten uutepitoisuuksien arviointiin, mutta se vaatii mittalaitteen joka käyttää usean ilmaisimen tekniikkaa. On-line-mittauksissa laitteisto tulisi varustaa automaattisella pesulaitteella, sillä mittarin linssit likaantuvat helposti prosessivirrassa.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Tieto on aina ollut yksi yrityksen tärkeimmistä resursseista, mutta vasta nyt siihen on alettu kiinnittää enemmän huomiota. Tiedonjohtaminen ja tietämyksen hallinta ovat haastavia ja osin hankaliakin toimintoja, koska on vaikeaa johtaa sellaista, mitä ei voi kuvata. Tietojohtamista voidaan kuitenkin ajatella prosessina, joka koostuu useammasta alaprosessista, kuten tiedon hankinta, tiedon luominen, tiedon varastointi, tiedon jakaminen ja tiedon soveltaminen. Kun ongelma-alue pilkotaan pienempiin kokonaisuuksiin, on siihen helpompi vaikuttaa. Tässä diplomityössä kehitettiin Stora Enso Publication Papers Oy Ltd Varkauden tehtaalle toimivia työkaluja/-menetelmiä tiedonjohtamisen ja tietämyksen hallinnan tueksi. Työssä luotiin yrityksen tarpeita vastaava mittaristomalli ja keskityttiin siinä erityisesti aineettomaan pääomaan liittyviin mittareihin. Jotta voidaan mitata jotain, on se ensin pystyttävä kuvaamaan. Siksi työssä käsiteltiin myös prosessijohtamista ja analysoitiin hieman yrityksen prosesseja sekä kehitettiin yritykselle uusi "tietojohtaminen" -prosessi. Mittariston ja prosessin luomisen lisäksi työssä esitettiin muutamia toimivia työkaluja/ menetelmiä tiedonjohtamisen ja tietämyksen hallinnan avuksi. Työn teoriaosuudessa tutustuttiin ensin prosessijohtamisen yleisimpiin teorioihin ja tarvittaviin käsitteisiin. Tämän jälkeen luotiin teoriapohja mittariston rakentamiseksi määrittelemällä käsitteet tieto ja aineeton pääoma sekä käsittelemällä muutamia mittaristomalleja, mittariston rakentamista ja aineettoman pääoman mittaamista. Tutkimuksen empiirisessä osassaanalysoitiin yrityksen johtamismalleja sekä määriteltiin prosessijohtamisessa käytetyt termit teorian pohjalta. Pääpaino työssä oli mittariston rakentamisessa ja tiedonjohtamisen sekä tietämyksen hallinnan tehostamisessa. Mittaristomalli luotiin useamman teorian pohjalta painottuen kuitenkinselvästi Balanced Scorecard -menetelmään. Työn tuloksena oli kattava mittaristomalli, aineettoman pääoman mittareita sekä uusia työkaluja/-menetelmiä tiedonjohtamiseen ja tietämyksen hallintaan.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Design aspects of the Transversally Laminated Anisotropic (TLA) Synchronous Reluctance Motor (SynRM) are studied and the machine performance analysis compared to the Induction Motor (IM) is done. The SynRM rotor structure is designed and manufactured for a30 kW, four-pole, three-phase squirrel cage induction motor stator. Both the IMand SynRM were supplied by a sensorless Direct Torque Controlled (DTC) variablespeed drive. Attention is also paid to the estimation of the power range where the SynRM may compete successfully with a same size induction motor. A technicalloss reduction comparison between the IM and SynRM in variable speed drives is done. The Finite Element Method (FEM) is used to analyse the number, location and width of flux barriers used in a multiple segment rotor. It is sought for a high saliency ratio and a high torque of the motor. It is given a comparison between different FEM calculations to analyse SynRM performance. The possibility to take into account the effect of iron losses with FEM is studied. Comparison between the calculated and measured values shows that the design methods are reliable. A new application of the IEEE 112 measurement method is developed and used especially for determination of stray load losses in laboratory measurements. The study shows that, with some special measures, the efficiency of the TLA SynRM is equivalent to that of a high efficiency IM. The power factor of the SynRM at rated load is smaller than that of the IM. However, at lower partial load this difference decreases and this, probably, brings that the SynRM gets a better power factor in comparison with the IM. The big rotor inductance ratio of the SynRM allows a good estimating of the rotor position. This appears to be very advantageous for the designing of the rotor position sensor-less motor drive. In using the FEM designed multi-layer transversally laminated rotor with damper windings it is possible to design a directly network driven motor without degrading the motorefficiency or power factor compared to the performance of the IM.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Ilmakehän hiukkaset aiheuttavat merkittäviä ympäristö- ja terveyshaittoja, joihin vaikuttaa hiukkasten kemiallinen koostumus. Hiukkasten kemiallisesta koostumuksesta voidaan hankkia tietoa hiukkasmittauksilla. Työn tavoitteena oli rakentaa jatkuvatoiminen mittausjärjestelmä, jolla voidaan mitata ilmakehän aerosolihiukkasten ionipitoisuuksia. Mittausjärjestelmä koostuu virtuaali-impaktorista, denuderputkista, PILS-laitteesta ja ionikromatografista. Näyteilmavirtaus kulkee ensin esierottimena toimivan virtuaali-impaktorm lävitse, joka poistaa aerodynaamiselta halkaisijaltaan 1,3 um:a suuremmat hiukkaset ilmavirtauksesta. Näyte, joka sisältää 1,3 um:a pienemmät hiukkaset kulkee virtuaali-impaktorin jälkeen kahden 1 % KOH-liuoksella käsitellyn denuderputken lävitse, joilla poistetaan hiukkasmääritystä häiritsevät happamat kaasut näytevirtauksesta. Denuderputkien jälkeen ilmavirtaus saapuu PILS-laitteeseen, jossa hiukkaset kasvatetaan vesihöyryn avulla aerosolipisaroiksi, törmäytetään keräyslevyyn ja sekoitetaan sen jälkeen sisäistä standardiainetta (NaBr) sisältavään kuljetusliuokseen. Kuljetusliuoksen ja aerosolipisaroiden seoksesta koostuva näyteliuos johdetaan PILS-laitteesta ionikromatografille analysoitavaksi. Mittausjärjestelmään liitetyllä ionikromatografilla voidaan analysoida neljä näytetta tunnissa. Näytteistä määritettävät anionit olivat sulfaatti, nitraatti ja kloridi. PILS-mittausjärjestelmää testattiin keräämällä hiukkasnäytteitä samanaikaisesti PILS-laitteella sekä virtuaali-impaktorilla tai suodatinkeräimellä ja vertaamalla saatuja aerosolihiukkasten sulfaattipitoisuuksia keskenään. Testeissa kerättiin joko VOAG-laitteella tuotettuja ammoniumsulfaattihiukkasia tai laboratorion huoneilmaa. PILS-mittausjärjestelmällä mitatut sulfaattipitoisuudet olivat 2-20 % pienempia kuin suodatinkeraimella mitatut, kun kerättiin keinotekoisesti tuotettuja ammoniumsulfaattihiukkasia. Huoneilmaa kerättäessä PILS-mittausjärjestelmällä saadut pitoisuudet olivat noin 10 % pienempiä kuin suodatinkeräystulokset. Koetulokset osoittivat, että mittausjärjestelmällä saadaan analysoiduksi luotettavasti hiukkasten sulfaattipitoisuudet.