965 resultados para Mean nuclear volume


Relevância:

90.00% 90.00%

Publicador:

Resumo:

A recent report on the correlation between enhanced polymer mobility and ionic conductivity at room temperature in plasticized polyether-urethane solid polymer electrolytes (Forsyth et al.[1]), has prompted the present investigation. Positron annihilation lifetime spectroscopy (PALS) has been used to study the effect of plasticizer addition on the room temperature free volume characteristics of the crosslinked polyether-urethane. The addition of low molecular weight plasticizers to the polyether-urethane results in a constant or decreasing mean free volume cavity radius, as measured by the orthoPositronium lifetime τ3, and a decreasing relative concentration of free volume cavities as measured by the ortho-Positronium intensity, I3. It is postulated that the plasticizers interrupt polymer-polymer interactions by occupying the inter- and intra-chain free volume. The plasticizer structure influences the polymerplasticizer interactions which affect inter- and intra-chain separation and hence the free volume of the system. The decrease in polymer-polymer interaction and the increase in polymer-plasticizer interaction in turn influence the glass transition temperature behaviour.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

In order to quantify the population of Acromyrmex balzani Emery, 1890 nests and to verify whether the population dynamic of the colony is correlated with the symbiont fungus volume, the principal energy source of the colony, five nests located in grassland areas were evaluated. The nests were sprayed with neutral talcum powder to improve visualization and digging. The symbiont fungus and the entire population existent in the chambers were collected. The mean fungus volume and total nest population in excavated nests were, respectively, 74.76 ml and 1,095 individuals. Simple linear correlation analysis verified that the fungus volume grew proportionally to the number of individuals. Despite the correlation between fungus volume and population dynamic of colonies, the factors that determine this relationship are little known since other microorganisms live in association with the colony.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

OBJETIVO: comparar duas metodologias para o cálculo do volume placentário em gestações normais de termo: a do princípio de Arquimedes e a do volume do cilindro, para estimar a densidade absoluta da placenta. Definir a metodologia mais adequada para o cálculo do volume e densidade placentários, que se relacione com o peso e classificação do recém-nascido. MÉTODOS: foram estudadas 50 placentas provenientes de gestações de termo sem complicações e calculados o volume e a densidade absoluta placentários: a) pelo princípio de Arquimedes e b) na suposição de que a placenta seria uma secção de cilindro com duas alturas diferentes do bolo placentário: com a altura média e com a altura da média aritmética do centro e extremidades. As densidades absolutas placentárias foram calculadas pelo quociente entre o peso ao ar da placenta e os diferentes volumes. RESULTADOS: a maioria das gestantes eram multíparas, idade média de 25,4 anos, volume placentário médio entre 547,8 e 610 cm³ e densidade média entre 0,94 e 1,14 g/cm³, dependendo da metodologia empregada. CONCLUSÕES: a metodologia mais adequada para estimar o volume placentário no termo foi a do princípio de Arquimedes, pela melhor correlação com o peso dos recém-nascidos, o índice placentário e a classificação do peso dos recém-nascidos em relação à idade gestacional.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

The photoinduced birefringence is analyzed in a guest-host azobenzene-containing polymer in the temperature range from 20 to 330 K. An anomalous behavior arises in the low-temperature range, suggesting strong influence from the free volume for the chromophores in the polymer. This influence is so strong that quenched samples have a photoinduced signal ca. 5 times greater than the annealed ones at room temperature. An extended free volume model is presented based on two assumptions about thermal fluctuations in the cavities and their size distribution. This model, which is an extension of the model by Mita et al., can explain the main features of the photoinduced birefringence as a function of time, temperature, and initial free volume state. To account for the influence of free volume on the photoorientation, the detailed reorientation model by Sekkat's was used. We show that Sekkat's model leads to an exponential behavior at small orientation regimes, which simplifies the mathematical treatment and allows the mean free volume to be obtained from the data fitting.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Thirty fine-needle biopsy (FNB) samples from 28 dogs subjected to surgical resection of cutaneous mast cell tumors (MCTs) were stained with Giemsa. At least 100 neoplastic cells from each cytology slide were evaluated by morphometric analysis. The parameters were: area, perimeter of the cell, cytoplasm, nucleus and circumference factor. MCTs of grade III had a mean cellular area of 231.70 μm2 ± 57.1, and grade II had a mean of 252.30 μm2 ± 55.0. Cellular perimeter was 61.20 ± 7.1 in grade II and 59.1 ± 8.6 in grade III. Cellular parameters were not statistically different between grades (p>.05). Mean nuclear area was 88.90 μm2 ± 19 in grade III and 72.30 μm2 ± 13.9 in grade II, with statistical difference between grades (P =.011). Mean nuclear perimeter was 32.40 ìm ± 3.0 in grade II and 35.70 ìm ± 4.0 in grade III, with statistical difference between grades (P =.018). Mean nuclear circumference factor was 1.0 ± 0.33 in grade II and 1.1 ± 0.28 in grade III, with no statistical difference between grades (P = 0.78). Nuclear-tocytoplasmic ratio in grade II was 0.29 ±.07 and 0.39 ±.08 in grade III, with statistical difference (P =.02). The number of binucleated and multinucleated cells and mitotic figures was significantly increased in grade III MCTs (P <.001). In conclusion, the number of mitotic figures, presence of binucleation and multinucleation, and nuclear-to-cytoplasmic ratio can help to guide a profile of MCT aggressiveness in cytologic preparations.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

90.00% 90.00%

Publicador:

Resumo:

The anisocytosis is a hematologic finding that is routinely evaluated from the mean corpuscular volume (MCV) and erythrocyte morphology in assessment of blood smears. The present study tested the hypothesis that the coefficient of variation of the red cell distribution width (RDW-CV - Red Cell Distribution Width) is a more sensitive parameter in the evaluation of hematologic anisocytosis, considering different levels of anemia in dogs and reticulocytosis. Blood counts of 102 anemic dogs and 353 control dogs made by automated hematology counter. The anemic animals were grouped according to the degree of anemia (mild, moderate and severe) and also as medullary response by manual reticulocyte count (none, weak, moderate and strong). The RDW-CV was different to the animal groups with moderate and severe anemia, which were higher, compared to the control group and mild anemia. The highest average value of RDW-CV (14.45%) occurred in patients with severe anemia. In the control group had higher MCV value that anemic animals , this may be due to a mixed population of erythrocytes in that group of animals. However, there wasn’t difference in MCV between different degrees of anemia and reticulocytosis. Therefore, the RDW is a more sensitive indicator anisocytosis than VCM and its value is directly proportional to the degree of anemia and reticulocytosis; when combined, the sensitivity for detection of anisocytosis in anemic dogs is greater. The use of reference values established by the clinical laboratory itself is mighty important.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Introduction: Small animal models are widely used in basic research. However, experimental systems requiring extracorporeal circuits are frequently confronted with limitations related to equipment size. This is particularly true for oxygenators in systems with limited volumes. Thus we aimed to develop and validate an ultra mini-oxygenator for low-volume, buffer-perfused systems. Methods: We have manufactured a series of ultra mini-oxygenators with approximately 175 aligned, microporous, polypropylene hollow fibers contained inside a shell, which is sealed at each of the two extremities to isolate perfusate and gas compartments. With this construction, gas passes through hollow fibers, while perfusate circulates around fibers. Performance of ultra mini-oxygenators (oxygen partial pressure (PO2 ), gas and perfusate flow, perfusate pressure and temperature drop) were assessed with modified Krebs-Henseleit buffer in an in vitro perfusion circuit and an ex vivo rat heart preparation. Results: Mean priming volume of ultra mini-oxygenators was 1.2±0.5 mL and, on average, 86±6% of fibers were open (n=17). In vitro, effective oxygenation (PO2=400-500 mmHg) was achieved for all flow rates up to 50 mL/min and remained stable for at least 2 hours (n=5). Oxygenation was also effective and stable (PO2=456±40 mmHg) in the isolated heart preparation for at least 60 minutes ("venous" PO2=151±11 mmHg; n=5). Conclusions: We have established a reproducible procedure for fabrication of ultra mini-oxygenators, which provide reliable and stable oxygenation for at least 60-120 min. These oxygenators are especially attractive for pre-clinical protocols using small, rather than large, animals.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

OBJECTIVES Oxygenation of blood and other physiological solutions are routinely required in fundamental research for both in vitro and in vivo experimentation. However, very few oxygenators with suitable priming volumes (<2-3 ml) are available for surgery in small animals. We have designed a new, miniaturized membrane oxygenator and investigated the oxygen-transfer performance using both buffer and blood perfusates. METHODS The mini-oxygenator was designed with a central perforated core-tube surrounded by parallel-oriented microporous polypropylene hollow fibres, placed inside a hollow shell with a lateral-luer outlet, and sealed at both extremities. With this design, perfusate is delivered via the core-tube to the centre of the mini-oxygenator, and exits via the luer port. A series of mini-oxygenators were constructed and tested in an in vitro perfusion circuit by monitoring oxygen transfer using modified Krebs-Henseleit buffer or whole porcine blood. Effects of perfusion pressure and temperature over flows of 5-60 ml × min(-1) were assessed. RESULTS Twelve mini-oxygenators with a mean priming volume of 1.5 ± 0.3 ml were evaluated. With buffer, oxygen transfer reached a maximum of 14.8 ± 1.0 ml O2 × l(-1) (pO2: 450 ± 32 mmHg) at perfusate flow rates of 5 ml × min(-1) and decreased with an increase in perfusate flow to 7.8 ± 0.7 ml ml O2 × l(-1) (pO2: 219 ± 24 mmHg) at 60 ml × min(-1). Similarly, with blood perfusate, oxygen transfer also decreased as perfusate flow increased, ranging from 33 ± 5 ml O2 × l(-1) at 5 ml × min(-1) to 11 ± 2 ml O2 × l(-1) at 60 ml × min(-1). Furthermore, oxygen transfer capacity remained stable with blood perfusion over a period of at least 2 h. CONCLUSIONS We have developed a new miniaturized membrane oxygenator with an ultra-low priming volume (<2 ml) and adequate oxygenation performance. This oxygenator may be of use in overcoming current limitations in equipment size for effective oxygenation in low-volume perfusion circuits, such as small animal extracorporeal circulation and ex vivo organ perfusion.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Gebiet: Chirurgie Biomedizintechnik Biophysik Transplantationsmedizin Kardiologie Abstract: OBJECTIVES: – Oxygenation of blood and other physiological solutions are routinely required in fundamental research for both in vitro and in vivo experimentation. However, very few oxygenators with suitable priming volumes (<2-3 ml) are available for surgery in small animals. We have designed a new, miniaturized membrane oxygenator and investigated the oxygen-transfer performance using both buffer and blood perfusates. – – METHODS: – The mini-oxygenator was designed with a central perforated core-tube surrounded by parallel-oriented microporous polypropylene hollow fibres, placed inside a hollow shell with a lateral-luer outlet, and sealed at both extremities. With this design, perfusate is delivered via the core-tube to the centre of the mini-oxygenator, and exits via the luer port. A series of mini-oxygenators were constructed and tested in an in vitro perfusion circuit by monitoring oxygen transfer using modified Krebs-Henseleit buffer or whole porcine blood. Effects of perfusion pressure and temperature over flows of 5-60 ml × min(-1) were assessed. – – RESULTS: – Twelve mini-oxygenators with a mean priming volume of 1.5 ± 0.3 ml were evaluated. With buffer, oxygen transfer reached a maximum of 14.8 ± 1.0 ml O2 × l(-1) (pO2: 450 ± 32 mmHg) at perfusate flow rates of 5 ml × min(-1) and decreased with an increase in perfusate flow to 7.8 ± 0.7 ml ml O2 × l(-1) (pO2: 219 ± 24 mmHg) at 60 ml × min(-1). Similarly, with blood perfusate, oxygen transfer also decreased as perfusate flow increased, ranging from 33 ± 5 ml O2 × l(-1) at 5 ml × min(-1) to 11 ± 2 ml O2 × l(-1) at 60 ml × min(-1). Furthermore, oxygen transfer capacity remained stable with blood perfusion over a period of at least 2 h. – – CONCLUSIONS: – We have developed a new miniaturized membrane oxygenator with an ultra-low priming volume (<2 ml) and adequate oxygenation performance. This oxygenator may be of use in overcoming current limitations in equipment size for effective oxygenation in low-volume perfusion circuits, such as small animal extracorporeal circulation and ex vivo organ perfusion. – – © The Author 2015. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

OBJECTIVES The aims of the study were to use cone beam computed tomography (CBCT) images of nasopalatine duct cysts (NPDC) and to calculate the diameter, surface area, and 3D-volume using a custom-made software program. Furthermore, any associations of dimensions of NPDC with age, gender, presence/absence of maxillary incisors/canines (MI/MC), endodontic treatment of MI/MC, presenting symptoms, and postoperative complications were evaluated. MATERIAL AND METHODS The study comprised 40 patients with a histopathologically confirmed NPDC. On preoperative CBCT scans, curves delineating the cystic borders were drawn in all planes and the widest diameter (in millimeter), surface area (in square millimeter), and volume (in cubic millimeter) were calculated. RESULTS The overall mean cyst diameter was 15 mm (range 7-47 mm), the mean cyst surface area 566 mm(2) (84-4,516 mm(2)), and the mean cyst volume 1,735 mm(3) (65-25,350 mm(3)). For 22 randomly allocated cases, a second measurement resulted in a mean absolute aberration of ±4.2 % for the volume, ±2.8 % for the surface, and ±4.9 % for the diameter. A statistically significant association was found for the CBCT determined cyst measurements and the need for preoperative endodontic treatment to MI/MC and for postoperative complications. CONCLUSION In the hands of a single experienced operator, the novel software exhibited high repeatability for measurements of cyst dimensions. Further studies are needed to assess the application of this tool for dimensional analysis of different jaw cysts and lesions including treatment planning. CLINICAL RELEVANCE Accurate radiographic information of the bone volume lost (osteolysis) due to expansion of a cystic lesion in three dimensions could help in personalized treatment planning.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Background. Australian Aborigines are experiencing epidemic proportions of renal disease, marked by albuminuria and, variably, hematuria. They also have high rates of low birth weight, which have been associated with lower kidney volumes and higher blood pressures. The authors evaluated relationships between kidney volume, blood pressure, albuminuria, and hematuria in 1 homogeneous group. Methods Forty-three percent (672 of 1,560) of the population in a remote coastal Australian Aboriginal community aged 4.4 to 72.1 years participated in the study. Results: Kidney size correlated closely with body size. Systolic blood pressure (SBP) was correlated inversely with kidney length and kidney volume, after adjusting for age, sex, and body surface area (BSA); a 1-cm increase in mean kidney length was associated with a 2.2-mm Hg decrease in SBP, and a 10-mL increase in mean kidney volume was associated with a 0.6-mm Hg decrease in SBP (P = 0.001). Mean kidney volume explained 10% of the variance in SBP in a multivariate model containing age, sex, and BSA. In addition to higher SBP, adults who had the lowest quartiles of kidney volume also had the highest levels of overt albuminuria (P = 0.044). Conclusion: Smaller kidneys predispose to higher blood pressures and albuminuria in this population. The lower volumes possibly represent kidneys with reduced nephron numbers, which might be related to an adverse intrauterine environment. Susceptibility to renal disease could be a direct consequence of reduced nephron numbers; the higher blood pressures with which they are associated could also contribute to, as well as derive from, this association.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Langerhans cells (LCs) can be targeted with DNA-coated gold micro-projectiles ("Gene Gun") to induce potent cellular and humoral immune responses. It is likely that the relative volumetric distribution of LCs and keratinocytes within the epidermis impacts on the efficacy of Gene Gun immunization protocols. This study quantified the three-dimensional (3D) distribution of LCs and keratinocytes in the mouse skin model with a near-infrared multiphoton laser-scanning microscope (NIR-MPLSM). Stratum corneum (SC) and viable epidermal thickness measured with MPLSM was found in close agreement with conventional histology. LCs were located in the vertical plane at a mean depth of 14.9 mum, less than 3 mum above the dermo-epidermal boundary and with a normal histogram distribution. This likely corresponds to the fact that LCs reside in the suprabasal layer (stratum germinativum). The nuclear volume of keratinocytes was found to be approximately 1.4 times larger than that of resident LCs (88.6 mum3). Importantly, the ratio of LCs to keratinocytes in mouse ear skin (1:15) is more than three times higher than that reported for human breast skin (1:53). Accordingly, cross-presentation may be more significant in clinical Gene Gun applications than in pre-clinical mouse studies. These interspecies differences should be considered in pre-clinical trials using mouse models.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The elastic properties of sodium borovanadate glasses have been studied over a wide range of composition using ultrasonic measurements. It is found that variation of different elastic moduli is very similar in any given series of composition. The bulk and shear moduli show a monotonic variation with the covalent bond energy densities calculated from the proposed structural model for these glasses. The bulk moduli also vary as a negative power function of the mean atomic volume. The Debye temperature varies linearly with the glass transition temperature. The implications of the observed behavior have been discussed.