996 resultados para Magnetic Suspension Balance


Relevância:

30.00% 30.00%

Publicador:

Resumo:

Fundamental studies of magnetic alignment of highly anisotropic mesostructures can enable the clean-room-free fabrication of flexible, array-based solar and electronic devices, in which preferential orientation of nano- or microwire-type objects is desired. In this study, ensembles of 100 micron long Si microwires with ferromagnetic Ni and Co coatings are oriented vertically in the presence of magnetic fields. The degree of vertical alignment and threshold field strength depend on geometric factors, such as microwire length and ferromagnetic coating thickness, as well as interfacial interactions, which are modulated by varying solvent and substrate surface chemistry. Microwire ensembles with vertical alignment over 97% within 10 degrees of normal, as measured by X-ray diffraction, are achieved over square cm scale areas and set into flexible polymer films. A force balance model has been developed as a predictive tool for magnetic alignment, incorporating magnetic torque and empirically derived surface adhesion parameters. As supported by these calculations, microwires are shown to detach from the surface and align vertically in the presence of magnetic fields on the order of 100 gauss. Microwires aligned in this manner are set into a polydimethylsiloxane film where they retain their vertical alignment after the field has been removed and can subsequently be used as a flexible solar absorber layer. Finally, these microwires arrays can be protected for use in electrochemical cells by the conformal deposition of a graphene layer.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The values of material physical properties are vital for the successful use of numerical simulations for electromagnetic processing of materials. The surface tension of materials can be determined from the experimental measurement of the surface oscillation frequency of liquid droplets. In order for this technique to be used, a positioning field is required that results in a modification to the oscillation frequency. A number of previous analytical models have been developed that mainly focus on electrically conducting droplets positioned using an A.C. electromagnetic field, but due to the turbulent flow resulting from the high electromagnetic fields required to balance gravity, reliable measurements have largely been limited to microgravity. In this work axisymmetric analytical and numerical models are developed, which allow the surface tension of a diamagnetic droplet positioned in a high DC magnetic field to be determined from the surface oscillations. In the case of D.C. levitation there is no internal electric currents with resulting Joule heating, Marangoni flow and other effects that introduce additional physics that complicates the measurement process. The analytical solution uses the linearised Navier-Stokes equations in the inviscid case. The body force from a DC field is potential, in contrast to the AC case, and it can be derived from Maxwell equations giving a solution for the magnetic field in the form of a series expansion of Legendre polynomials. The first few terms in this expansion represent a constant and gradient magnetic field valid close to the origin, which can be used to position the droplet. Initially the mathematical model is verified in microgravity conditions using a numerical model developed to solve the transient electromagnetics, fluid flow and thermodynamic equations. In the numerical model (as in experiment) the magnetic field is obtained using electrical current carrying coils, which provides the confinement force for a liquid droplet. The model incorporates free surface deformation to accurately model the oscillations that result from the interaction between the droplet and the non-uniform external magnetic field. A comparison is made between the analytical perturbation theory and the numerical pseudo spectral approximation solutions for small amplitude oscillations.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Laboratory studies were conducted to evaluate the interaction between bare and polymer-coated magnetic nanoparticles (MNPs) with various environmentally relevant carrying solutions including natural oceanic seawater with and without addition of algal exopolymeric substances (EPS). The MNPs were coated with three different stabilising agents, namely gum Arabic (GA-MNP), dextran (D-MNP) and carboxymethyl-dextran (CMD-MNP). The colloidal stability of the suspensions was evaluated over 48 h and we demonstrated that: (i) hydrodynamic diameters increased over time regardless of carrying solution for all MNPs except the GA-coated ones; however, the relative changes were carrying solution- and coat-dependent; (ii) polydispersity indexes of the freshly suspended MNPs are below 0.5 for all coated MNPs, unlike the much higher values obtained for the uncoated MNPs; (iii) freshly prepared MNP suspensions (both coated and uncoated) in Milli-Q (MQ) water show high colloidal stability as indicated by zeta-potential values below -30 mV, which however decrease in absolute value within 48 h for all MNPs regardless of carrying solution; (iv) EPS seems to "stabilise" the GA-coated and the CMD-coated MNPs, but not the uncoated or the D-coated MNPs, which form larger aggregates within 48 h; (v) despite this aggregation, iron (Fe)-leaching from MNPs is sustained over 48 h, but remained within the range of 3-9% of the total iron-content of the initially added MNPs regardless of suspension media and capping agent. The environmental implications of our findings and biotechnological applicability of MNPs are discussed.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Cellulose-magnetite composites have been prepared by suspension and dispersion of magnetite particles in a homogenous ionic liquid solution of cellulose, followed by regeneration into water, enabling the preparation of magnetically responsive films, flocs, fibers, or beads. The materials prepared were ferromagnetic, with a small superparamagnetic response, characteristic of the initial magnetite added. X-ray diffraction data indicated that the magnetite particles were chemically unaltered after encapsulation with an average particle size of approximately 25 nm.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Affiliation: Département de Psychologie, Université de Montréal

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Oxide free stable metallic nanofluids have the potential for various applications such as in thermal management and inkjet printing apart from being a candidate system for fundamental studies. A stable suspension of nickel nanoparticles of ∼5 nm size has been realized by a modified two-step synthesis route. Structural characterization by x-ray diffraction and transmission electron microscopy shows that the nanoparticles are metallic and are phase pure. The nanoparticles exhibited superparamagnetic properties. The magneto-optical transmission properties of the nickel nanofluid (Ni-F) were investigated by linear optical dichroism measurements. The magnetic field dependent light transmission studies exhibited a polarization dependent optical absorption, known as optical dichroism, indicating that the nanoparticles suspended in the fluid are non-interacting and superparamagnetic in nature. The nonlinear optical limiting properties of Ni-F under high input optical fluence were then analyzed by an open aperture z-scan technique. The Ni-F exhibits a saturable absorption at moderate laser intensities while effective two-photon absorption is evident at higher intensities. The Ni-F appears to be a unique material for various optical devices such as field modulated gratings and optical switches which can be controlled by an external magnetic field

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A magnetic resin based on cardanol, furfural, and curaua fibers was prepared and characterized. The material could be used in oil-spill cleanup processes, because of its aromatic/aliphatic balance. The resin was prepared through bulk polycondensation of cardanol and furfural in the presence of curaua fibers and maghemite nanoparticles. Hydrophobicity of the curaua fibers was improved by acetylation, increasing the oil-absorbing capability of the composites. The obtained magnetic composites were studied by Fourier-transform infrared spectroscopy, X-ray diffraction, and thermogravimetric analysis. Degree of cure, magnetic force, and oil-removal capability tests were also performed. The results show that the composites possess an elevated cure degree in addition to a considerable magnetic force. The materials exhibit a good oil removal capability in the presence of a magnetic field, which is improved by the use of acetylated curaua. In the best case, the composite filled with maghemite and curaua can remove 12 parts of oil from water.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Magnetic susceptibility (chi, mass specific) is useful for easy indirect estimation of other soil properties at a low cost. The aim of this study was to assess the use of chi as measured with an analytical balance for predicting properties with a substantial influence on the management of Typic Haplustalfs in southern Brazil. To achieve this 48 topsoil samples were taken at the intersection points in a rectangular grid of 20 m x 20 m cells, with 38 of these used for calibration and 10 for validation in regression analyses. The obtained chi values were slightly higher than, and highly correlated (r = 0.970; P < 0.001) with those measured with a susceptibility meter. Highly significant (P < 0.001) correlations were also found between chi and other soil properties relevant to soil classification and management such as clay content (r = 0.68), cation exchange capacity (r = 0.62), P sorption capacity (r = 0.76) and haematite content (r = 0.82). Results from a principal component analysis of eight properties important for soil classification explained 11% of the variance in the data set. The good predictive ability of chi was consistent with current knowledge on the formation pathways for pedogenic ferrimagnets. In summary, chi, which can be readily measured with an analytical balance, has the potential for quantifying soil attributes and may therefore be used in pedotransfer functions.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Wet impregnation of pre-synthesized surfactant-stabilized aqueous rhodium (0) colloidal suspension on silica was employed in order to prepare supported Rh-0 nanoparticles of well-defined composition, morphology and size. A magnetic core-shell support of silica (Fe(3)O4@SiO2) was used to increase the handling properties of the obtained nanoheterogeneous catalyst. The nanocomposite catalyst Fe3O4@SiO2-Rh-0 NPs was highly active in the solventless hydrogenation of model olefins and aromatic substrates under mild conditions with turnover frequencies up to 143,000 h(-1). The catalyst was characterized by various transmission electron microscopy techniques showing well-dispersed rhodium nanoparticles (similar to 3 nm) mainly located at the periphery of the silica coating. The heterogeneous magnetite-supported nanocatalyst was investigated in the hydrogenation of cyclohexene and compared to the previous surfactant-stabilized aqueous Rh-0 colloidal suspension and various silica-supported Rh-0 nanoparticles. Finally, the composite catalyst could be reused in several runs after magnetic separation. (C) 2011 Elsevier B. V. All rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This work evaluates the spatial distribution of normalised rates of droplet breakage and droplet coalescence in liquidliquid dispersions maintained in agitated tanks at operation conditions normally used to perform suspension polymerisation reactions. Particularly, simulations are performed with multiphase computational fluid dynamics (CFD) models to represent the flow field in liquidliquid styrene suspension polymerisation reactors for the first time. CFD tools are used first to compute the spatial distribution of the turbulent energy dissipation rates (e) inside the reaction vessel; afterwards, normalised rates of droplet breakage and particle coalescence are computed as functions of e. Surprisingly, multiphase simulations showed that the rates of energy dissipation can be very high near the free vortex surfaces, which has been completely neglected in previous works. The obtained results indicate the existence of extremely large energy dissipation gradients inside the vessel, so that particle breakage occurs primarily in very small regions that surround the impeller and the free vortex surface, while particle coalescence takes place in the liquid bulk. As a consequence, particle breakage should be regarded as an independent source term or a boundary phenomenon. Based on the obtained results, it can be very difficult to justify the use of isotropic assumptions to formulate particle population balances in similar systems, even when multiple compartment models are used to describe the fluid dynamic behaviour of the agitated vessel. (C) 2011 Canadian Society for Chemical Engineering

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The present study investigated whether postural responses are influenced by the stability constraint of a voluntary, manual task. We also examined how task constraint and first experience (the condition with which the participants started the experiment) influence the kinematic strategies used to simultaneously accomplish a postural response and a voluntary task. Twelve healthy, older adults were perturbed during standing, while holding a tray with a cylinder placed with the flat side down (low constraint, LC) or with the rolling, round side down (high constraint, HC). Central set changed according to the task constraint, as shown by a higher magnitude of both the gastrocnemius and tibialis anterior muscle activation bursts in the HC than in the LC condition. This increase in muscle activation was not reflected, however, in changes in the center of pressure or center of mass displacement. Task constraint influenced the peak shoulder flexion for the voluntary tray task but not the peak hip flexion for the postural task. In contrast, first experience influenced the peak hip flexion but not the peak shoulder flexion. These results suggest an interaction between two separate control mechanisms for automatic postural responses and voluntary stabilization tasks.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

We investigate the occurrence of the optical Kerr effect and two-photon absorption when an oil-based magnetic Fe3O4 nanoparticles colloidal suspension is illuminated with high intensity femtosecond laser pulses. The frequency of the pulses is controlled and the Z-scan technique is employed in our measurements of the nonlinear optical Kerr coefficient (n(2)) and two-photon absorption coefficient (beta). From these values it was possible to calculate the real and imaginary parts of the third-order susceptibility. We observed that increasing the pulse frequency, additional physical processes take place, increasing artificially the absolute values of n(2) and beta. The experimental conditions are discussed to assure the obtention of reliable values of these nonlinear optical parameters, which may be useful in all-optical switching and optical power limiting applications. (C) 2012 American Institute of Physics. [http://dx.doi.org/10.1063/1.4723829]

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Interhemispheric imbalance is discussed as a pathophysiological mechanism in visuospatial neglect. It is suggested that after a lesion of the right hemisphere the mutual transcallosal inhibition is impaired, resulting in an increased activity of the left hemisphere. We investigated the interhemispheric balance of attention in healthy subjects by using a free visual exploration task and by interfering with the neural activity of the posterior parietal cortex (PPC) of either hemisphere using an inhibitory transcranial magnetic stimulation routine with theta burst stimulation (TBS). Subjects explored colour photographs of real-life scenes presented on a computer screen under four conditions: (i) without TBS; (ii) after TBS over the right PPC; (iii) after TBS over the left PPC; and (iv) after TBS over the right PPC and, after the first half of the task, over the left PPC. Eye movements were measured, and distribution of mean cumulative fixation duration over screen halves was analyzed. TBS over the right PPC resulted in a significant rightward shift of mean cumulative fixation duration of approximately 30 min. The shift could be reversed when a subsequent train of TBS was applied over the left PPC. However, left PPC stimulation alone had no significant effect on visual exploration behaviour. The present study shows that the effect of TBS on the PPC depends on which hemisphere is stimulated and on the state of the contralateral homologue area. These findings are in accordance with the predictions of the interhemispheric rivalry model in neglect.