988 resultados para MICRO-CT IMAGING


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Veneer fracture is the most common complication in zirconia-based restorations. The aim of this study was to evaluate the mechanical behavior of a zirconia-based crown in a lower canine tooth supporting removable partial denture (RPD) prosthesis, varying the bond quality of the veneer/coping interface. Microtomography (μCT) data of an extracted left lower canine were used to build the finite element model (M) varying the core material (gold core - MAu; zirconia core - MZi) and the quality of the veneer/core interface (complete bonded - MZi; incomplete bonded - MZi-NL). The incomplete bonding condition was only applied for zirconia coping by using contact elements (Target/Contact) with 0.3 frictional coefficients. Stress fields were obtained using Ansys Workbench 10.0. The loading condition (L = 1 N) was vertically applied at the base of the RPD prosthesis metallic support towards the dental apex. Maximum principal (σmax) and von Mises equivalent (σvM) stresses were obtained. The σmax (MPa) for the bonded condition was similar between gold and zirconia cores (MAu, 0.42; MZi, 0.40). The incomplete bonded condition (MZi-NL) raised σmax in the veneer up to 800% (3.23 MPa) in contrast to the bonded condition. The peak of σvM increased up to 270% in the MZi-NL. The incomplete bond condition increasing the stress in the veneer/zirconia interface.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This master’s thesis describes the research done at the Medical Technology Laboratory (LTM) of the Rizzoli Orthopedic Institute (IOR, Bologna, Italy), which focused on the characterization of the elastic properties of the trabecular bone tissue, starting from october 2012 to present. The approach uses computed microtomography to characterize the architecture of trabecular bone specimens. With the information obtained from the scanner, specimen-specific models of trabecular bone are generated for the solution with the Finite Element Method (FEM). Along with the FEM modelling, mechanical tests are performed over the same reconstructed bone portions. From the linear-elastic stage of mechanical tests presented by experimental results, it is possible to estimate the mechanical properties of the trabecular bone tissue. After a brief introduction on the biomechanics of the trabecular bone (chapter 1) and on the characterization of the mechanics of its tissue using FEM models (chapter 2), the reliability analysis of an experimental procedure is explained (chapter 3), based on the high-scalable numerical solver ParFE. In chapter 4, the sensitivity analyses on two different parameters for micro-FEM model’s reconstruction are presented. Once the reliability of the modeling strategy has been shown, a recent layout for experimental test, developed in LTM, is presented (chapter 5). Moreover, the results of the application of the new layout are discussed, with a stress on the difficulties connected to it and observed during the tests. Finally, a prototype experimental layout for the measure of deformations in trabecular bone specimens is presented (chapter 6). This procedure is based on the Digital Image Correlation method and is currently under development in LTM.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Recently, the field of forensics has experienced a rapid increase in the use of modern cross-sectional imaging in forensic investigations. We examined the value of post-mortem computed tomography (CT) imaging relative to autopsy for distinguishing aspiration into the lungs from airways, from lung alterations due to other causes, and for identifying the aspirated material. We selected 54 bodies submitted to whole-body CT scanning prior to autopsy. All cases had autopsy findings of blood (31 cases), fresh water (12 cases), or gastric content (11 cases) aspiration. The radiological images were retrospectively analyzed for airway and lung aspiration. In all cases, CT imaging detected pulmonary abnormalities suggestive of aspiration. Nevertheless, analysis of the CT images alone was not able to identify the aspirated material or to distinguish pulmonary findings of aspiration from lung changes due to other causes, except for a few cases of hemo-aspiration. However, due to its ability to visualize the entire parenchyma, CT imaging was superior to autopsy in providing additional data about the distribution and severity of the aspiration as well as in detecting small abnormalities. Post-mortem CT imaging should be considered as a superior tool for forensic investigations of aspiration due to its ability to document diagnostic conclusions and to guide the forensic pathologist during lung tissue examination.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

PURPOSE: The aim of this paper is to demonstrate that computed tomography (CT) and three-dimensional (3D) CT imaging techniques can be useful tools for evaluating gunshot wounds of the skull in forensic medicine. Three purposes can be achieved: (1) identifying and recognising the bullet entrance wound - and exit wound, if present; (2) recognising the bullet's intracranial course by studying damage to bone and brain tissue; (3) suggesting hypotheses as to the dynamics of the event. MATERIALS AND METHODS: Ten cadavers of people who died of a fatal head injury caused by a single gunshot were imaged with total-body CT prior to conventional autoptic examination. Three-dimensional-CT reconstructions were obtained with the volume-rendering technique, and data were analysed by two independent observers and compared with autopsy results. RESULTS: In our experience, CT analysis and volumetric reconstruction techniques allowed the identification of the bullet entrance and exit wounds and intracranial trajectory, as well as helping to formulate a hypothesis on the extracranial trajectory to corroborate circumstantial evidence. CONCLUSIONS: CT imaging techniques are excellent tools for addressing the most important questions of forensic medicine in the case of gunshot wounds of the skull, with results as good as (or sometimes better than) traditional autoptic methods.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Many children with sarcomas undergo whole body 2-deoxy-2-((18)F)fluoro-D-glucose positron emission tomography/computed tomography ((18)F-FDG PET/CT) and technetium methylene diphosphonate ((99)Tc-MDP) studies. It is unknown whether the combination of both tests results in more accurate detection of bone lesions than (18)F-FDG- PET/CT alone.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

To assess the effect of tumor size and tumor-to-liver contrast of simulated hypovascular liver tumors on the diagnostic accuracy of hepatic computed tomography (CT).

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The use of dental processing software for computed tomography (CT) data (Dentascan) is described on postmortem (pm) CT data for the purpose of pm identification. The software allows reconstructing reformatted images comparable to conventional panoramic dental radiographs by defining a curved reconstruction line along the teeth on oblique images. Three corpses that have been scanned within the virtopsy project were used to test the software for the purpose of dental identification. In every case, dental panoramic images could be reconstructed and compared to antemortem radiographs. The images showed the basic component of teeth (enamel, dentin, and pulp), the anatomic structure of the alveolar bone, missing or unerupted teeth as well as restorations of the teeth that could be used for identification. When streak artifacts due to metal-containing dental work reduced image quality, it was still necessary to perform pm conventional radiographs for comparison of the detailed shape of the restoration. Dental identification or a dental profiling seems to become possible in a noninvasive manner using the Dentascan software.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Whereas a non-operative approach for hemodynamically stable patients with free intraabdominal fluid in the presence of solid organ injury is generally accepted, the presence of free fluid in the abdomen without evidence of solid organ injury not only presents a challenge for the treating emergency physician but also for the surgeon in charge. Despite recent advances in imaging modalities, with multi-detector computed tomography (CT) (with or without contrast agent) usually the imaging method of choice, diagnosis and interpretation of the results remains difficult. While some studies conclude that CT is highly accurate and relatively specific at diagnosing mesenteric and hollow viscus injury, others studies deem CT to be unreliable. These differences may in part be due to the experience and the interpretation of the radiologist and/or the treating physician or surgeon.A search of the literature has made it apparent that there is no straightforward answer to the question what to do with patients with free intraabdominal fluid on CT scanning but without signs of solid organ injury. In hemodynamically unstable patients, free intraabdominal fluid in the absence of solid organ injury usually mandates immediate surgical intervention. For patients with blunt abdominal trauma and more than just a trace of free intraabdominal fluid or for patients with signs of peritonitis, the threshold for a surgical exploration - preferably by a laparoscopic approach - should be low. Based on the available information, we aim to provide the reader with an overview of the current literature with specific emphasis on diagnostic and therapeutic approaches to this problem and suggest a possible algorithm, which might help with the adequate treatment of such patients.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

PURPOSE Positron emission tomography (PET)∕computed tomography (CT) measurements on small lesions are impaired by the partial volume effect, which is intrinsically tied to the point spread function of the actual imaging system, including the reconstruction algorithms. The variability resulting from different point spread functions hinders the assessment of quantitative measurements in clinical routine and especially degrades comparability within multicenter trials. To improve quantitative comparability there is a need for methods to match different PET∕CT systems through elimination of this systemic variability. Consequently, a new method was developed and tested that transforms the image of an object as produced by one tomograph to another image of the same object as it would have been seen by a different tomograph. The proposed new method, termed Transconvolution, compensates for differing imaging properties of different tomographs and particularly aims at quantitative comparability of PET∕CT in the context of multicenter trials. METHODS To solve the problem of image normalization, the theory of Transconvolution was mathematically established together with new methods to handle point spread functions of different PET∕CT systems. Knowing the point spread functions of two different imaging systems allows determining a Transconvolution function to convert one image into the other. This function is calculated by convolving one point spread function with the inverse of the other point spread function which, when adhering to certain boundary conditions such as the use of linear acquisition and image reconstruction methods, is a numerically accessible operation. For reliable measurement of such point spread functions characterizing different PET∕CT systems, a dedicated solid-state phantom incorporating (68)Ge∕(68)Ga filled spheres was developed. To iteratively determine and represent such point spread functions, exponential density functions in combination with a Gaussian distribution were introduced. Furthermore, simulation of a virtual PET system provided a standard imaging system with clearly defined properties to which the real PET systems were to be matched. A Hann window served as the modulation transfer function for the virtual PET. The Hann's apodization properties suppressed high spatial frequencies above a certain critical frequency, thereby fulfilling the above-mentioned boundary conditions. The determined point spread functions were subsequently used by the novel Transconvolution algorithm to match different PET∕CT systems onto the virtual PET system. Finally, the theoretically elaborated Transconvolution method was validated transforming phantom images acquired on two different PET systems to nearly identical data sets, as they would be imaged by the virtual PET system. RESULTS The proposed Transconvolution method matched different PET∕CT-systems for an improved and reproducible determination of a normalized activity concentration. The highest difference in measured activity concentration between the two different PET systems of 18.2% was found in spheres of 2 ml volume. Transconvolution reduced this difference down to 1.6%. In addition to reestablishing comparability the new method with its parameterization of point spread functions allowed a full characterization of imaging properties of the examined tomographs. CONCLUSIONS By matching different tomographs to a virtual standardized imaging system, Transconvolution opens a new comprehensive method for cross calibration in quantitative PET imaging. The use of a virtual PET system restores comparability between data sets from different PET systems by exerting a common, reproducible, and defined partial volume effect.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

PURPOSE The goal of this study was to investigate whether different computed tomography (CT) energy levels could supply additional information for the differentiation of dental materials for forensic investigations. METHODS Nine different commonly used restorative dental materials were investigated in this study. A total of 75 human third molars were filled with the restorative dental materials and then scanned using the forensic reference phantom in singlesource mode. The mean Hounsfield unit values and standard deviations (SDs) of each material were calculated at 120, 80 and 140 kVp. RESULTS Most of the dental materials could be differentiated at 120 kVp. We found that greater X-ray density of a material resulted in higher SDs and that the material volume could influence the measurements. CONCLUSION Differentiation of dental materials in CT was possible in many cases using single-energy CT scans at 120 kVp. Because of the number of dental restorative materials available and scanner and scan parameter dependence, as well as the CT imaging artifacts, the identification (in contrast to differentiation) was problematic.