1000 resultados para Métodos de Referência


Relevância:

40.00% 40.00%

Publicador:

Resumo:

The aim of this investigation was to evaluate four reference methods to estimate evapotranspiration (Makkink, Hargreaves, Class A pan and Radiation), compared tb Penman-Monteith method, that is considered standard by the Food and Agricultural Organization of the United Nations (FAO). Errors due to variable measurements in the reference evapotranspiration estimate were taken into consideration. The research was developed in an experimental area of the Department of Rural Engieering of the School of Agricultural and Veterinarian Sciences, Campus of Jaboticabal, São Paulo State University. An automated weather station was used and it was equipped with sensors to measure global and net radiation, temperature, relative humidity, and wind speed. The aftermath showed a better adjustment to Hargreaves. Makkink, Class A pan and Radiation methods are different from Penman-Monteith, therefore, they cannot be compared. To evaluate methods to estimate evapotranspiration and avoid possible evaluation errors, ETo estimate errors must be considered.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Pós-graduação em Agronomia (Ciência do Solo) - FCAV

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Pós-graduação em Agronomia (Irrigação e Drenagem) - FCA

Relevância:

40.00% 40.00%

Publicador:

Resumo:

As regiões escolhidas para o estudo são importantes no cenário citrícola irrigado, tanto em expansão quanto em atuação. Os dados meteorológicos utilizados para as estimativas são integrantes do banco de dados climáticos do software IRRIPLUS®. Com este software, estimou-se a evapotranspiração de referência (ETo) diária, utilizando as metodologias propostas por Penman-Monteith (EToPM), Hargreaves & Samani (EToHG) e Blaney-Criddle-FAO (EToBC), para o período de um ano. O objetivo deste estudo foi comparar os métodos de estimativa com EToPM, utilizando parâmetros de regressão (β0, β1), coeficiente de determinação (r²), e correlação (r), estimativa do erro-padrão (SEE), índices de concordância (d) e confiança (c). Os resultados indicam tendência de EToHG à superestimativa dos valores de ETo, exceto na região de Jaú, e subestimativa por EToBC, para todas as regiões estudadas. Nos valores mensais de ETo, os três métodos apresentam a mesma distribuição. O método de EToHG apresenta-se como uma excelente alternativa na estimativa de consumo de água pela cultura.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Pós-graduação em Agronomia (Ciência do Solo) - FCAV

Relevância:

40.00% 40.00%

Publicador:

Resumo:

A estimativa da evapotranspiração de referência (ETo), usada no balanço hídrico, possibilita quantificar o armazenamento de água no solo, auxiliando no manejo da irrigação. O objetivo do trabalho foi comparar métodos mais simples de estimativa da evapotranspiração de referência com o método Penman-Monteith (FAO), nas escalas diária e de 5, 10, 15 e 30 dias, e mensal, para os municípios de Frederico Westphalen e Palmeira das Missões, no RS. Os métodos avaliados tenderam a melhorar a eficiência com o aumento da escala temporal de estudo, mantendo o mesmo desempenho para ambas as localidades. Os maiores e menores valores de ETo ocorreram nos meses de dezembro e junho, respectivamente. A maioria dos métodos subestimou os valores de ETo. Em qualquer escala temporal, os métodos de Makking e da Radiação FAO24 podem substituir o modelo de Penman-Monteith.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Este trabalho teve como objetivo comparar métodos empíricos de estimativa de evapotranspiração de referência (ETo) diária em relação ao método Penman-Monteith/FAO para o município de Cristino Castro-Piauí, utilizando série de dados coletados em estação agrometeorológica convencional para o período 01 de janeiro de 2010 a 31 dezembro de 2012.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Actualmente a Tomografia Computorizada (TC) é um dos métodos de diagnóstico por imagem que tem uma maior contribuição para a dose de radiação X recebida pelos pacientes. Pretende-se com este estudo avaliar as doses praticadas em TC e contribuir para o estabelecimento de Níveis de Referência de Diagnóstico (NRD) na região da Grande Lisboa, Portugal. Foram efectuadas medições de dose em 5 equipamentos de TC multidetectores, considerando o abdómen como área anatómica de interesse. Recorreu-se a uma câmara de ionização e a um fantoma para obter o índice de dose de TC (CTDI) e o produto dose-comprimento (DLP), que permitem determinar os NRD. Estes valores foram comparados com os NRD propostos pela Guideline Europeia e com os estudos desenvolvidos em outros países, como o Reino Unido, Grécia e Taiwan. Os resultados revelaram que os valores de NRD obtidos neste estudo (16,7 mGy para o CTDIvol e 436,5 mGy·cm para o DLP) são discrepantes relativamente à Guideline Europeia (±50%), mas muito próximos relativamente aos NRD estabelecidos nos países considerados. Estes valores podem ser eventualmente explicados pelos equipamentos em análise e pela utilização de protocolos de exame adoptados pelos profissionais de Radiologia nas instituições analisadas. ABSTRACT - Nowadays Computed Tomography (CT) is one of the imaging techniques which have a large contribution to radiation dose received by patients. The purpose of this study is to evaluate CT doses and contribute to the establishment of Diagnostic Reference Levels (DRL) in Lisbon, Portugal. Dose measurements on 5 multidetector CT scanners have been performed, considering the abdomen as the anatomic region of interest. All measurements were performed using an ionization chamber and a phantom to obtain the index CT dose (CTDI) and the dose-length product (DLP), which are used to determine DRL. These values were compared not only with European reference dose values but also with DRL studies developed in other countries like United Kingdom, Greece and Taiwan. The results revealed that DRL values obtained in this study (CTDIvol is 16,7 mGy and DLP is 436,5 mGy·cm) have a higher discrepancy to European Guideline (±50%), while the DRL´s of other countries are nearest to values obtained in this study. Those differences may be eventually explained by the type of the evaluated equipments but also by the exam protocols used by the Radiology professionals on the analyzed institutions.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

OBJETIVO: Compreender as possibilidades e os limites da articulação dos processos de trabalho desenvolvidos por agentes com diferentes formações para otimizar a integração e melhorar a qualidade da assistência aos pacientes com HIV/Aids. MÉTODOS: Estudo qualitativo sobre o trabalho multiprofissional em cinco centros de referência para DST/Aids do Município de São Paulo. Foram realizadas entrevistas semi-estruturadas com 26 profissionais de diferentes formações, enfocando suas relações no modo de organização da assistência prestada nesses serviços. RESULTADOS: Houve diferenças significativas do alcance da integração multiprofissional e das possibilidades de enriquecimento da assistência prestada, de acordo com as circunstâncias em que o trabalho interdisciplinar é posto em ação. CONCLUSÕES: Quando a equipe consegue trabalhar com demandas antevistas, isto é, com a formulação, por um conjunto de profissionais, de projetos assistenciais, antecipando demandas a partir de situações concretas da prática, criam-se condições favoráveis a um trabalho mais efetivamente integrado da equipe multiprofissional. Essa integração favorece intervenções que permitem um diálogo mais rico entre a aplicação do tratamento medicamentoso e outras dimensões relevantes do cuidado referentes às vivências sociais, psicológicas e emocionais dos pacientes.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

OBJETIVO: Verificar a magnitude da diferença de preço entre os medicamentos genéricos e os respectivos medicamentos de referência, além de avaliar o efeito da concorrência entre eles quanto aos seus preços. MÉTODOS: De janeiro de 2000 a junho de 2004, foram acompanhadas 135 apresentações de medicamentos genéricos e seus respectivos medicamentos de referência por um período de até quatro anos. Os preços foram extraídos de publicações específicas voltadas para o comércio farmacêutico, e foram anotados os preços para ambos os medicamentos, desde o lançamento do genérico e durante período de comercialização posterior. RESULTADOS: Os genéricos foram introduzidos, em média, com preços 40% menores do que os medicamentos de referência e esta diferença tendeu a aumentar ao longo do tempo. Comparando a diferença de preço do genérico em relação ao seu medicamento de referência observou-se aumento de 68% nos quatro anos seguintes ao seu lançamento. CONCLUSÕES: A introdução de medicamentos genéricos no mercado farmacêutico brasileiro contribuiu para a oferta de medicamentos a preços menores. Entretanto, a procura dos medicamentos genéricos não provocou redução dos preços da maioria dos medicamentos de referência.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

OBJETIVO: O conhecimento dos erros de amostragem é necessário à correta interpretação dos resultados de inquéritos domiciliares e à avaliação dos seus planos de amostragem. A composição das amostras de domicílios utilizadas em inquéritos caracteriza situação complexa de estimação. Nesse sentido, realizou-se estudo com o objetivo de avaliar o desempenho de estimadores de variância em inquéritos efetuados em populações urbanas brasileiras. MÉTODOS: A população de referência do estudo constituiu-se de amostra sorteada pela Fundação Sistema Estadual de Análise de Dados Estatísticos, para a realização da Pesquisa de Emprego e Desemprego na Região Metropolitana de São Paulo. Para estimar variâncias foram utilizados: o método de linearização de Taylor e as técnicas de replicação Jackknife e BRR. Repetidas amostras foram retiradas da população de referência utilizando amostragem estratificada, por conglomerados, em dois estágios: setor censitário e domicílio. Três delineamentos foram utilizados e 2.000 amostras foram sorteadas sob cada um deles. Para um estimador razão, foi avaliada a acurácia dos estimadores de variância, por meio do erro quadrático médio, e a cobertura dos intervalos de confiança. RESULTADOS: Os resultados relacionados ao erro quadrático médio relativo dos estimadores foram semelhantes. As razões de vício ficaram em torno de 0,10 para as menores amostras. As coberturas dos intervalos de confiança indicaram que os níveis de confiança observados foram menores que os fixados (95%), ficando em torno de 90% para as menores amostras. CONCLUSÕES: Os estimadores de variância mostraram desempenhos semelhantes quanto à acurácia e cobertura dos intervalos de confiança. Os vícios foram irrelevantes frente às dimensões do erro-padrão. Os níveis de confiança reais foram menores que os níveis nominais da distribuição normal, mas as alterações não impedem que estimativas intervalares sejam feitas com razoável confiança.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Objectivo: Estabelecer valores de referência da robustez óssea nos primeiros dias de vida, em recém-nascidos de termo e pré-termo adequados para a idade de gestação nascidos em Portugal. Métodos: Foi medida a velocidade do som (VdS) (m/s) por ultrassonografia quantitativa, numa amostra sistemática de recém-nascidos adequados para a idade de gestação, de termo e pré-termo, respectivamente nos primeiros dois e cinco dias após o nascimento. Foi avaliada a homogeneidade de valores entre géneros e entre grupos de idade de gestação. Resultados: A amostra constou de 158 recém-nascidos, 34 de termo e 124 pré-termo (idade de gestação entre 26 a 41 semanas), com peso de nascimento de 595 g a 4195 g, 84 do sexo masculino (53,2%) e 20 gémeos (10,8%). A média da VdS aumenta significativamente com a idade de gestação. São providenciados valores de referência da VdS para os percentis 10, 25, 50, 75 e 90, para grupos de idade de gestação, sem distinção para o género. Conclusão: São disponibilizados valores de referência de VdS nos primeiros dias de vida, de recém-nascidos adequados para a idade de gestação, de termo e pré-termo, nascidos em Portugal. Estes valores reflectem a robustez óssea intrauterina e servem de referência basal para estudos evolutivos realizados em Portugal.