996 resultados para Load testing


Relevância:

60.00% 60.00%

Publicador:

Resumo:

To perform a comparative evaluation of the mechanical resistance of simulated fractures of the mandibular body which were repaired using different fixation techniques with two different brands of 2.0 mm locking fixation systems. Four aluminum hemimandibles with linear sectioning simulating a mandibular body fracture were used as the substrates and were fixed using the two techniques and two different brands of fixation plate. These were divided into four groups: groups I and II were fixed with one four-hole plate, with four 6 mm screws in the tension zone and one four-hole plate, with four 10 mm screws in the compression zone; and groups III and IV were fixed with one four-hole plate with four 6 mm screws in the neutral zone. Fixation plates manufactured by Tóride were used for groups I and III, and by Traumec for groups II and IV. The hemimandibles were submitted to vertical, linear load testing in an Instron 4411 servohydraulic mechanical testing unit, and the load/displacement (3 mm, 5 mm and 7 mm) and the peak loads were measured. Means and standard deviations were evaluated applying variance analysis with a significance level of 5%. The only significant difference between the brands was seen at displacements of 7 mm. Comparing the techniques, groups I and II showed higher mechanical strength than groups III and IV, as expected. For the treatment of mandibular linear body fracture, two locking plates, one in the tension zone and another in the compression zone, have a greater mechanical strength than a single locking plate in the neutral zone.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

As classificações geomecânicas são uma das abordagens mais reconhecidas para estimar a qualidade do maciço rochoso, face à sua simplicidade e competência para gerir incertezas. As incertezas geológicas e geotécnicas podem ser avaliadas de forma eficaz usando classificações adequadas. Este estudo pretende enfatizar a importância das classificações geomecânicas e índices geomecânicos, tais como a Rock Mass Rating (RMR), a Rock Tunnelling Quality Index (Qsystem), o Geological Strength Index (GSI) e o Hydro‐Potential (HP) Value, para ajuizar a qualidade do maciço rochoso granítico das galerias subterrâneas de Paranhos (setor de Carvalhido ‐ Burgães; área urbana do Porto). Em particular, o valor hidro‐potencial (HP‐value) é uma classificação semi‐quantitativa aplicada a maciços rochosos que permite estimar as infiltrações de água subterrânea em escavações de terrenos rochosos. Para esta avaliação foi compilada e integrada uma extensa base de dados geológico‐geotécnica e geomecânica, apoiada na técnica de amostragem linear de superfícies expostas descontinuidades. Para refinar o zonamento geotécnico do maciço rochoso granítico, previamente realizado em 2010, foram coletadas amostras de rocha em pontos‐chave, com o objetivo de avaliar a sua resistência através do Ensaio de Carga Pontual (PLT). A aplicação das classificações geomecânicas foi realizada de uma forma equilibrada, estabelecendo diferentes cenários e tendo sempre em conta o conhecimento das características do maciço in situ. Apresenta‐se uma proposta de zonamento hidrogeomecânico com o objetivo de compreender melhor a circulação geo‐hidráulica do maciço rochoso granítico. Pretende‐se com esta metodologia contribuir para aprofundar o conhecimento do substrato rochoso do Porto, nomeadamente no que diz respeito ao seu comportamento geomecânico.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Este trabalho tem como objetivo sublinhar a importância de um estudo geológico‐geotécnico para apoiar a cartografia geotécnica do maciço rochoso subterrâneo da antiga mina de volfrâmio das Aveleiras (Mosteiro de Tibães, Braga). Foi realizado um trabalho de campo sistemático, ao longo de uma rede de galerias subterrâneas com uma extensão aproximada de 155 m. Estas galerias são constituídas, principalmente, por rochas metassedimentares, embora aflorem rochas graníticas num pequeno trecho de uma das galerias. A técnica de amostragem linear de descontinuidades aplicada ao grau de compartimentação do maciço rochoso esteve na base de todos os dados geológicos, geotécnicos e geomecânicos. Além disso, foram coligidos e integrados os dados de campanhas de campo anteriores, realizadas entre 2006 e 2011. Foram igualmente descritos os métodos de avaliação dos dados de campo, bem como a análise estatística dos parâmetros geológico‐geotécnicos. O zonamento geotécnico do maciço rochoso das Aveleiras foi desenvolvido tendo em conta o comportamento do maciço rochoso in situ, e foi apoiado por ensaios laboratoriais de resistência do material‐rocha através do Ensaio de Carga Pontual. Apresenta‐se uma proposta preliminar de zonamento geomecânico com o objectivo de apoiar o projeto de engenharia de maciços rochosos.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Dissertação de mestrado Integrado em Engenharia Civil

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Background and aim: H epatitis E v irus (HEV) infection has emerged as a c ause o f travel-related a nd autochthonous a cute hepatitis as well as chronic hepatitis in immunosuppressed patients. While t ravel-related cases a re c aused primarily b y infections w ith HEV of g enotype 1 ( HEV-1), autochthonous c ases a nd chronic cases a re d ue t o genotype 3 (HEV-3), which is s hared between humans and diverse animal species. The aim of this study was to establish HEV RNA detection assays f or q uantitative v iral load testing and genotyping. Methods: V iral RNA was p urified from plasma or s erum a nd converted to cDNA prior to (1) multiplex real-time PCR for HEV RNA quantification and (2) multiplex PCR coupled to DNA sequencing for HEV genotype determination. Real-time PCR was d esigned to match a ll known HEV genotypes available i n Genbank while PCR was designed using conserved primers flanking a variable region of the HEV RNA. Results: In a validation panel, the newly developed assays allowed for the reliable detection and genotyping of HEV-1 or HEV-3. Cases of t ravel-related and a utochthonous a cute h epatitis E a s well a s chronic hepatitis E i n immunosuppressed patients have b een identified using t hese a ssays a nd will be p resented in detail. Anti- HEV antibodies were n egative i n three well-characterized patients with chronic hepatitis E after organ transplantation. Conclusions: We developed and validated a quantitative HEV RNA detection assay that c an now be o ffered on a r outine basis (www.chuv.ch/imul/imu-collaborations-viral_hepatitis). Genotyping can also be offered on selected cases. HEV RNA detection is key in diagnosing chronic hepatitis E i n immunosuppressed patients with unexplained transaminase elevations, as serology can be negative in these patients.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

In an attempt to solve the bridge problem faced by many county engineers, this investigation focused on a low cost bridge alternative that consists of using railroad flatcars (RRFC) as the bridge superstructure. The intent of this study was to determine whether these types of bridges are structurally adequate and potentially feasible for use on low volume roads. A questionnaire was sent to the Bridge Committee members of the American Association of State Highway and Transportation Officials (AASHTO) to determine their use of RRFC bridges and to assess the pros and cons of these bridges based on others’ experiences. It was found that these types of bridges are widely used in many states with large rural populations and they are reported to be a viable bridge alternative due to their low cost, quick and easy installation, and low maintenance. A main focus of this investigation was to study an existing RRFC bridge that is located in Tama County, IA. This bridge was analyzed using computer modeling and field load testing. The dimensions of the major structural members of the flatcars in this bridge were measured and their properties calculated and used in an analytical grillage model. The analytical results were compared with those obtained in the field tests, which involved instrumenting the bridge and loading it with a fully loaded rear tandem-axle truck. Both sets of data (experimental and theoretical) show that the Tama County Bridge (TCB) experienced very low strains and deflections when loaded and the RRFCs appeared to be structurally adequate to serve as a bridge superstructure. A calculated load rating of the TCB agrees with this conclusion. Because many different types of flatcars exist, other flatcars were modeled and analyzed. It was very difficult to obtain the structural plans of RRFCs; thus, only two additional flatcars were analyzed. The results of these analyses also yielded very low strains and displacements. Taking into account the experiences of other states, the inspection of several RRFC bridges in Oklahoma, the field test and computer analysis of the TCB, and the computer analysis of two additional flatcars, RRFC bridges appear to provide a safe and feasible bridge alternative for low volume roads.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Abstract: As a part of an innovation project funded by the Federal Highway Administration (FHWA) Highways for LIFE program, a full-depth precast, ultra-high-performance concrete (UHPC) waffle deck panel and appropriate connections suitable for field implementation of waffle decks were developed. Following a successful full-scale validation test on a unit consisting of two panels with various types of connections under laboratory conditions, the waffle deck was installed successfully on a replacement bridge in Wapello County, Iowa. The subsequent load testing confirmed the desirable performance of the UHPC waffle deck bridge. Using the lessons from the completed project and outcomes from a series of simple and detailed finite element analyses of waffle decks, this report was developed to serve as a guide for broadening the design and installation of the UHPC waffle deck panel in new and existing bridges. Following an introduction to UHPC and waffle deck panels and a summary of completed work, this document presents information on waffle deck design, design of connections, redecking using waffle deck panels, and guidance on precast fabrication, construction, and installation of UHPC waffle deck panels.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

This project continues the research which addresses the numerous bridge problems on the Iowa secondary road system. It is a continuation (Phase 2) of Project HR-382, in which two replacement alternatives (Concept 1: Steel Beam Precast Units and Concept 2: Modification of the Benton County Beam-in-Slab Bridge) were investigated. In previous research for concept 1, a precast unit bridge was developed through laboratory testing. The steel-beam precast unit bridge requires the fabrication of precast double-tee (PCDT) units, each consisting of two steel beams connected by a reinforced concrete deck. The weight of each PCDT unit is minimized by limiting the deck thickness to 4 in., which permits the units to be constructed off-site and then transported to the bridge site. The number of units required is a function of the width of bridge desired. Once the PCDT units are connected, a cast-in-place reinforced concrete deck is cast over the PCDT units and the bridge railing attached. Since the steel beam PCDT unit bridge design is intended primarily for use on low-volume roads, used steel beams can be utilized for a significant cost savings. In previous research for concept 2, an alternate shear connector (ASC) was developed and subjected to static loading. In this investigation, the ASC was subjected to cyclic loading in both pushout specimens and composite beam tests. Based on these tests, the fatigue strength of the ASC was determined to be significantly greater than that required in typical low volume road single span bridges. Based upon the construction and service load testing, the steel-beam precast unit bridge was successfully shown to be a viable low volume road bridge alternative. The construction process utilized standard methods resulting in a simple system that can be completed with a limited staff. Results from the service load tests indicated adequate strength for all legal loads. An inspection of the bridge one year after its construction revealed no change in the bridge's performance. Each of the systems previously described are relatively easy to construct. Use of the ASC rather than the welded studs significantly simplified the work, equipment, and materials required to develop composite action between the steel beams and the concrete deck.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

This project continues the research which addresses the numerous bridge problems on the Iowa secondary road system. It is a continuation (Phase 2) of Project HR-382, in which two replacement alternatives (Concept 1: Steel Beam Precast Units and Concept 2: Modification of the Benton County Beam-in-Slab Bridge) were investigated. In previous research for concept 1, a precast unit bridge was developed through laboratory testing. The steel-beam precast unit bridge requires the fabrication of precast double-tee (PCDT) units, each consisting of two steel beams connected by a reinforced concrete deck. The weight of each PCDT unit is minimized by limiting the deck thickness to 4 in., which permits the units to be constructed off-site and then transported to the bridge site. The number of units required is a function of the width of bridge desired. Once the PCDT units are connected, a cast-in-place reinforced concrete deck is cast over the PCDT units and the bridge railing attached. Since the steel beam PCDT unit bridge design is intended primarily for use on low-volume roads, used steel beams can be utilized for a significant cost savings. In previous research for concept 2, an alternate shear connector (ASC) was developed and subjected to static loading. In this investigation, the ASC was subjected to cyclic loading in both pushout specimens and composite beam tests. Based on these tests, the fatigue strength of the ASC was determined to be significantly greater than that required in typical low volume road single span bridges. Based upon the construction and service load testing, the steel-beam precast unit bridge was successfully shown to be a viable low volume road bridge alternative. The construction process utilized standard methods resulting in a simple system that can be completed with a limited staff. Results from the service load tests indicated adequate strength for all legal loads. An inspection of the bridge one year after its construction revealed no change in the bridge's performance. Each of the systems previously described are relatively easy to construct. Use of the ASC rather than the welded studs significantly simplified the work, equipment, and materials required to develop composite action between the steel beams and the concrete deck.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

There are hundreds of structurally deficient or functionally obsolete bridges in the state of Iowa. With the majority of these bridges located on rural county roads where there is limited funding available to replace the bridges, diagnostic load testing can be utilized to determine the actual load carrying capacity of the bridge. One particular family or fleet of bridges that has been determined to be desirable for load testing consists of single-span bridges with non-composite, cast-in-place concrete decks, steel stringers, and timber substructures. Six bridges with poor performing superstructure and substructure from the aforementioned family of bridges were selected to be load tested. The six bridges were located on rural roads in five different counties in Iowa: Boone, Carroll, Humboldt, Mahaska, and Marshall. Volume I of this report focuses on evaluating the superstructure for this family of bridges. This volume discusses the behavior characteristics that influence the load carrying capacity of this fleet of bridges. In particular, the live load distribution, partial composite action, and bearing restraint were investigated as potential factors that could influence the bridge ratings. Implementing fleet management practices, the bridges were analyzed to determine if the load test results could be predicted to better analyze previously untested bridges. For this family of bridges it was found that the ratings increased as a result of the load testing demonstrating a greater capacity than determined analytically. Volume II of this report focuses on evaluating the timber substructure for this family of bridges. In this volume, procedures for detecting pile internal decay using nondestructive ultrasonic stress wave techniques, correlating nondestructive ultrasonic stress wave techniques to axial compression tests to estimate deteriorated pile residual strength, and evaluating load distribution through poor performing timber substructure elements by instrumenting and load testing the abutments of the six selected bridges are discussed. Also, in this volume pile repair methods for restoring axial and bending capacities of pile are developed and evaluated.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Based on previous National Bridge Inventory data, the state of Iowa has nearly 20,000 bridges on low-volume roads (LVRs). Thus, these bridges are the responsibility of the county engineers. Of the bridges on the county roads, 24 percent are structurally deficient and 5 percent are functionally obsolete. A large number of the older bridges on the LVRs are built on timber piling with timber back walls. In many cases, as timber abutments and piers age, the piling and back wall planks deteriorate at a rate faster than the bridge superstructure. As a result, a large percentage of the structurally deficient bridges on LVRs are classified as such because of the condition of the timber substructure elements. As funds for replacing bridges decline and construction costs increase, effective rehabilitation and strengthening techniques for extending the life of the timber substructures in bridges with structurally sound superstructures has become even more important. Several counties have implemented various techniques to strengthen/repair damaged piling, however, there is minimal data documenting the effectiveness of these techniques. There are numerous instances where cracked and failed pilings have been repaired. However, there are no experimental data on the effectiveness of the repairs or on the percentage of load transferred from the superstructure to the sound pile below. To address the research needs, a review and evaluation of current maintenance and rehabilitation methods was completed. Additionally, a nationwide survey was conducted to learn the methods used beyond Iowa. Field investigation and live-load testing of bridges with certain Iowa methods was completed. Lastly, laboratory testing of new strengthening and rehabilitation methods was performed.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

AIMS: There is no standard test to determine the fatigue resistance of denture teeth. With the increasing number of patients with implant-retained dentures the mechanical strength of the denture teeth requires more attention and valid laboratory test set-ups. The purpose of the present study was to determine the fatigue resistance of various denture teeth using a dynamic load testing machine. METHODS: Four denture teeth were used: Bonartic II (Candulor), Physiodens (Vita), SR Phonares II (Ivoclar Vivadent) and Trubyte (Dentsply). For dynamic load testing, first upper molars with a similar shape and cusp inclination were selected. The molar teeth were embedded in cylindrical steel molds with denture base material (ProBase, Ivoclar Vivadent). Dynamic fatigue loading was carried out on the mesio-buccal cusp at a 45° angle using dynamic testing machines and 2,000,000 cycles at 2Hz in water (37°C). Three specimens per group and load were submitted to decreasing load levels (at least 4) until all the three specimens no longer showed any failures. All the specimens were evaluated under a stereo microscope (20× magnification). The number of cycles reached before observing a failure, and its dependence on the load and on the material, has been modeled using a parametric survival regression model with a lognormal distribution. This allowed to estimate the fatigue resistance for a given material as the maximal load for which one would observe less than 1% failure after 2,000,000 cycles. RESULTS: The failure pattern was similar for all denture teeth, showing a large chipping of the loaded mesio-buccal cusp. In our regression model, there were statistically significant differences among the different materials, with SR Phonares II and Bonartic II showing a higher resistance than Physiodens and Trubyte, the fatigue resistance being estimated at around 110N for the former two, and at about 60N for the latter two materials. CONCLUSION: The fatigue resistance may be a useful parameter to assess and to compare the clinical risk of chipping and fracture of denture tooth materials.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Kuormitustestaus on osa web-sovellusten kehitystä ja käyttöönottoa. Sillä varmistetaan sovellusten toimivuus ennalta määrätyn kuorman alla. Microsoft Office SharePoint Server 2007 (MOSS) on palvelintuote nykyaikaisten web-sovellusten luontiin ja ylläpitoon. Työssä vertaillaan kahta eri uormitustestaustyökalua: SilkPerformer 2008 ja Visual Studio Team System 2008 Test Edition ja valitaan MOSS – web-sovelluksille paremmin sopiva työkalu. Työssä vertaillaan työkaluja niiden ominaisuuksien perusteella sekä suorittamalla kuormitustestausta testausta varten luodulle MOSS – web-sovellukselle. Vaikuttavien tekijöiden perusteella työkaluja arvioidaan ja tämän perusteella saadaan tulos vertailulle. Työn tuloksena Visual Studio Team System 2008 Test Edition sopii paremmin MOSS – web-sovelluksen kuormitustestausvälineeksi. Vertailussa kuitenkin havaittiin, että työkalut ovat melko tasavertaisia, ja käytännön tilanteesta riippuu, kumpi sopii paremmin. Tämä työ auttaa valinnan teossa.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

We evaluated dyspnea perception in cystic fibrosis patients compared with normal subjects, during an inspiratory resistive loading test and 6-min walk test. We also evaluated the correlation between dyspnea scores induced by resistive loads and by the 6-min walk test. In this prospective, cross-sectional study, 31 patients with cystic fibrosis (≥15 years of age) and 31 age-, gender-, and ethnicity-matched healthy volunteers (20 females and 11 males per group) underwent inspiratory resistive loading, spirometry, and the 6-min walk test. As the magnitude of the inspiratory loads increased, dyspnea scores increased (P<0.001), but there was no difference between groups in dyspnea score (P=0.654). Twenty-six (84%) normal subjects completed all the resistive loads, compared with only 12 (39%) cystic fibrosis patients (P<0.001). Dyspnea scores were higher after the 6-min walk test than at rest (P<0.001), but did not differ between groups (P=0.080). Post-6-min walk test dyspnea scores correlated significantly with dyspnea scores induced by resistive loads. We conclude that dyspnea perception induced in cystic fibrosis patients by inspiratory resistive loading and by 6-min walk test did not differ from that induced in normal subjects. However, cystic fibrosis patients discontinued inspiratory resistive loading more frequently. There were significant correlations between dyspnea perception scores induced by inspiratory resistance loading and by the 6-min walk test. This study should alert clinicians to the fact that some cystic fibrosis patients fail to discriminate dyspnea perception and could be at risk for delay in seeking medical care.