902 resultados para Liquid based cytology
Resumo:
Hormone therapy is an important tool in the treatment of breast cancer and tamoxifen represents one of the most important drugs used in this type of treatment. Recently other drugs based on the inhibition of aromatase had been developed, this enzyme is responsible for the synthesis of estrogenic esteroids from the androgenic ones. The objective of this study would be the development of a quantitative cytological model of murine estral analysis that allowed the characterization of different hormone drugs effect over vaginal epithelium. The technique of monochromatic staining with Evans blue (C.I. 23860) showed to be efficient in the qualitative and quantitative classification of the cycle. It had been observed differences in the cytological standard of animals submitted to the studied drugs; tamoxifen presented a widening of phases of lesser maturation (diestrais), while anastrozole and exemestane increased the duration of the phases of larger maturation (estrais). The data were analysed through a cubical non linear regression (spline) which allowed a better characterization of the drugs, suggesting a proper cytological profile to the antagonism of the estrogen receptor (tamoxifen), aromatase competition (anastrozole) and inhibition of the enzyme (exemestane)
Resumo:
The cancer of the uterine cervix remains a serious public health problem in developing countries with low social-economic conditions. Papanicolaou smear has been used to screen women for cervical cancer since 1940, and it is widely recognized as an effective method for preventing cervical cancer. In Brazil, conventional Papanicolaou is the most common method used in diagnosis cytopathological routine, involving the morphological cell analysis by microscopic examination of cervical samples smeared on glass slides. On the other hand, the liquid cytology is an advantageous method whose specimen collected is put into a fluid alcohol based to guarantee the potential use of residual cellular material in cytobrush. Moreover, this method permits additional diagnostic studies, preserving the morphological cell features as the conventional one does. The aim of the present study was report the historical evolution of different cervical cytologic tests, emphasizing the advantages and disadvantages between conventional Papanicolaou method and new technologies in liquid based cytology.
Resumo:
O HPV (Papilomavírus humano) foi apontado pela OMS (Organização Mundial de Saúde - WHO) como principal fator de risco para o desenvolvimento do câncer de colo uterino, tornando-se assim um importante e gravíssimo problema de saúde pública, especialmente nos países subdesenvolvidos ou em desenvolvimento. A precocidade das atividades sexuais, múltiplos parceiros e sexo casual, o tabagismo, a imunossupressão (por exemplo, na população de pacientes aidéticos), gravidez, doenças sexualmente transmissíveis prévias como herpes e clamídia, além do não cumprimento das medidas já adotadas como prevenção de Doenças Sexualmente Transmissíveis (DST), como por exemplo, o simples uso de preservativos, está reconhecidamente associado à incidência da infecção por HPV. Essa pesquisa teve como objetivo avaliar o desempenho diagnóstico das metodologias de citologia convencional (Exame de Papanicolau) em relação à citologia em base líquida, além de determinar a prevalência dos genótipos 16 e 18 do HPV em mulheres sem efeito citopático compatível com HPV e relacionar a presença de quadros inflamatórios, associados ou não ao HPV, com dados epidemiológicos como idade, escolaridade, condição sociocultural de mulheres provenientes do município de Barcarena – Pará – Brasil. Para tanto, participaram deste estudo, voluntariamente, 50 mulheres atendidas na Unidade de Saúde de Barcarena – Pará, através de campanha para coleta de Exame de Papanicolau como método de prevenção de câncer do colo do útero. Estas mulheres receberam informações referentes a todos os procedimentos realizados pelo corpo de saúde deste estudo e aos resultados desta pesquisa e somente após as voluntárias terem assinado o Termo de Consentimento Livre e Esclarecido, as mesmas foram incluídas para as coletas de amostras. As análises e os resultados dos testes de citologia de base líquida e convencional foram realizados segundo a Classificação de Bethesda e revisados cegamente por dois citopatologistas. Para a análise estatístca foi utilizado o teste exato de Fisher e o "Screening Test" visando determinar a especificidade/ sensibilidade dos métodos, considerando significativo o valor de p ≤ 0,05. Como resultado, observamos que o uso da citologia de base líquida tem demonstrado uma série de vantagens em relação à citologia convencional. No diagnóstico molecular (PCR) foram observadas ocorrências de HPV dos tipos 16 e 18 em 10% das mulheres atendidas. Dentre os casos que apresentaram PCR positivo para os tipos 16 ou 16/18 a maioria das mulheres tinham 27,4 anos de idade em média; com maior escolaridade; que exercem atividades domésticas e rurais; e com ocorrências de co-infecção por agentes infecciosos causadores de outras doenças sexualmente transmissíveis. Os resultados obtidos neste estudo reforçam a importância da manutenção de campanhas gratuitas de prevenção do câncer de colo do útero como uma medida preventiva no combate desta doença, principalmente no Estado do Pará onde, provavelmente, o perfil epidemiológico da doença está associado às grandes distâncias que as mulheres de comunidades ribeirinhas têm que percorrer para realizar este exame de forma gratuita; ao tipo de atividade econômica da região; ao preconceito local ainda existente com o exame; e ao grau de dificuldade de implementação de ações efetivas de retorno das pacientes às consultas médicas após a obtenção do resultado do exame e mesmo o encaminhamento para diagnóstico molecular dos casos positivos para lesões do tipo ASC-H e NIC I, II e III.
Resumo:
We sought to evaluate the performance of diagnostic tools to establish an affordable setting for early detection of cervical cancer in developing countries. We compared the performance of different screening tests and their feasibility in a cohort of over 12,000 women: conventional Pap smear, liquid-based cytology, visual inspection with acetic acid (VIA), visual inspection with Iodine solution (VILI), cervicography, screening colposcopy, and high-risk human papillomavirus (HPV) testing (HR-HPV) collected by physician and by self-sampling. HR-HPV assay collected by the physician has the highest sensitivity (80 %), but high unnecessary referrals to colposcopy (15.1 %). HR-HPV test in self-sampling had a markedly lower (57.1 %) sensitivity. VIA, VILI, and cervicography had a poor sensitivity (47.4, 55, and 28.6 %, respectively). Colposcopy presented with sensitivity of 100 % in detecting CIN2+, but the lowest specificity (66.9 %). Co-testing with VIA and VILI Pap test increased the sensitivity of stand-alone Pap test from 71.6 to 87.1 % and 71.6 to 95 %, respectively, but with high number of unnecessary colposcopies. Co-testing with HR-HPV importantly increased the sensitivity of Pap test (to 86 %), but with high number of unnecessary colposcopies (17.5 %). Molecular tests adjunct to Pap test seems a realistic option to improve the detection of high-grade lesions in population-based screening programs.
Resumo:
BACKGROUND Cytology is an excellent method with which to diagnose preinvasive lesions of the uterine cervix, but it suffers from limited specificity for clinically significant lesions. Supplementary methods might predict the natural course of the detected lesions. The objective of the current study was to test whether a multicolor fluorescence in situ hybridization (FISH) assay might help to stratify abnormal results of Papanicolaou tests. METHODS A total of 219 liquid-based cytology specimens of low-grade squamous intraepithelial lesions (LSIL), 49 atypical squamous cells of undetermined significance (ASCUS) specimens, 52 high-grade squamous intraepithelial lesion (HSIL) specimens, and 50 normal samples were assessed by FISH with probes for the human papillomavirus (HPV), MYC, and telomerase RNA component (TERC). Subtyping of HPV by polymerase chain reaction (PCR) was performed in a subset of cases (n=206). RESULTS There was a significant correlation found between HPV detection by FISH and PCR (P<.0001). In patients with LSILs, the presence of HPV detected by FISH was significantly associated with disease progression (P<.0001). An increased MYC and/or TERC gene copy number (>2 signals in>10% of cells) prevailed in 43% of ASCUS specimens and was more frequent in HSIL (85%) than in LSIL (33%) (HSIL vs LSIL: P<.0001). Increased TERC gene copy number was significantly correlated with progression of LSIL (P<.01; odds ratio, 7.44; area under the receiver operating characteristic curve, 0.73; positive predictive value, 0.30; negative predictive value, 0.94) CONCLUSIONS: The detection of HPV by FISH analysis is feasible in liquid-based cytology and is significantly correlated with HPV analysis by PCR. The analysis of TERC gene copy number may be useful for risk stratification in patients with LSIL.
Resumo:
O linfoma canino é uma das neoplasias mais prevalentes em cães, diagnosticado frequentemente através de exame citológico de aspirados. A imunofenotipagem para diferenciação entre linfomas de células B e T é importante para definição prognóstica e tratamento, entretanto, dificilmente é realizada em materiais provenientes de aspirados citológicos. A citologia em meio líquido (CML) é uma metodologia automatizada de produção de esfregaços citológicos, que permite a conservação de todo o material da aspiração, e utilização do material residual para, por exemplo, produção de emblocado celular (EC) e imunocitoquímica. Este trabalho teve como objetivo aplicar a CML e EC com imunocitoquímica em amostras de linfonodos caninos suspeitos para linfoma. Além disso, pretendeu caracterizar morfologicamente as células linfoides neste tipo de preparado, comparando ao esfregaço convencional. Para isto, foram selecionados 54 cães com linfadenomegalia, 10 deles sorologicamente positivos para leishmaniose canina. Comparou-se a CML com a citologia convencional, quanto às características técnicas e testou-se dois métodos diferentes de EC: Bouin e agarose com formalina. Aplicou-se painel imunocitoquímico de anticorpos anti-CD3, anti-CD79a, anti-Pax-5 e anti-Ki67, para imunofenotipagem e determinação da proliferação celular. Adicionalmente, realizaram-se análises estatísticas para avaliação do desempenho e concordância interobservador comparada entre citologia convencional, CML e o uso conjunto de CML e imunocitoquímica do emblocado celular. Como resultado, as células linfoides apresentaram-se preservadas, com melhor definição de cromatina e nucléolos, porém com tamanho reduzido e pior definição citoplasmática, na CML. O EC de Bouin revelou grupos densos e bem definidos, que permitiram a aplicação da imunocitoquímica. Por outro lado, os emblocados de agarose, apresentaram-se frouxos, com células marcadamente dispersas, revelando-se inadequados para preparados de células linfoides. O anticorpo anti-Pax-5 mostrou-se mais adequado do que o anti-CD79a para marcação de células B em emblocados, por produzir menos fundo e pela marcação nuclear ser mais distinguível do que a citoplasmática. A concordância interobservadores da CML foi moderada (k= 0,434), enquanto a da citologia convencional foi boa (k=0,762). Ambas as técnicas exibiram a mesma acurácia e, com aplicação da CML, houve redução do percentual de amostras insatisfatórias. A CML em conjunto com EC e imunocitoquímica apresentou maior sensibilidade (75%), especificidade (99%) e acurácia (89,47%). Como conclusão, a CML em conjunto com EC e imunocitoquímica pode ser aplicada para diagnóstico de linfoma canino, com maior sensibilidade, especificidade e acurácia
Resumo:
Highly stable and crystalline V(2)O(5) nanoparticles with an average diameter of 15 nm have been easily prepared by thermal treatment of a bariandite-like vanadium oxide, V(10)O(24)center dot 9H(2)O. Their characterization was carried out by powder X-ray diffractometry (XRD). Fourier transform infrared (FT-IR) and Raman spectroscopies, and transmission electron microscopy (TEM). The fibrous and nanostructured film obtained by electrophoretic deposition of the V(2)O(5) nanoparticles showed good electroactivity when submitted to cyclic voltammetry in an ionic liquid-based electrolyte. The use of this film for the preparation of a nanostructured electrode led to an improvement of about 50% in discharge capacity values when compared with similar electrodes obtained by casting of a V(2)O(5) xerogel. (C) 2009 Elsevier Inc. All rights reserved.
Resumo:
Food lipid major components are usually analyzed by individual methodologies using diverse extractive procedures for each class. A simple and fast extractive procedure was devised for the sequential analysis of vitamin E, cholesterol, fatty acids, and total fat estimation in seafood, reducing analyses time and organic solvent consumption. Several liquid/liquid-based extractive methodologies using chlorinated and non-chlorinated organic solvents were tested. The extract obtained is used for vitamin E quantification (normal-phase HPLC with fluorescence detection), total cholesterol (normal-phase HPLC with UV detection), fatty acid profile, and total fat estimation (GC-FID), all accomplished in <40 min. The final methodology presents an adequate linearity range and sensitivity for tocopherol and cholesterol, with intra- and inter-day precisions (RSD) from 3 to 11 % for all the components. The developed methodology was applied to diverse seafood samples with positive outcomes, making it a very attractive technique for routine analyses in standard equipped laboratories in the food quality control field.
Resumo:
Introduction: The samples obtained from fine needle aspiration in liquid base cytology (FNAC) are often limited by scarce cellularity compared to the amount of colloid and presence of blood. Accordingly, it was important to test alternative technical procedures so as to maximize the cellularity of each sample. Objective: To compare the morphological features and cellularity of the three procedures in the FNAC cytodiagnosis of the thyroid. Methods: A total of 31 cases were each subjected to a cell block and ThinPrep preparation as well as a routine smear. The observation and analysis was performed using an optical microscope. Cytological diagnosis of each cell block case was objectively analysed for cellularity, presence of background and cellular preservation. Each smear and ThinPrep case was analysed for the presence or absence of cells. The data was analysed with Microsoft Excel (Office 2010) and SPSS (Statistical Package of Social Science) version 15.0 for Windows. Results: Of 31 cases, only 20 had thyroid cells in the cell block and ThinPrep preparations, however, all smear cases contained thyroid cells. Some background was found in 30 Cell block cases with only 5 of these containing well preserved cells for cytodiagnosis. Conclusions: As indicated by the results, smear is the most appropriate procedure for FNAC of the thyroid.
Resumo:
OBJECTIVES: There is a continuing need to monitor and evaluate the impact of organized screening programmes on cancer incidence and mortality. We report results from a programme assessment conducted within the International Cancer Screening Network (ICSN) to understand the characteristics of cervical screening programmes within countries that have established population-based breast cancer screening programmes. METHODS: In 2007-2008, we asked 26 ICSN country representatives to complete a web-based survey that included questions on breast and cervical cancer screening programmes. We summarized information from 16 countries with both types of organized programmes. RESULTS: In 63% of these countries, the organization of the cervical cancer screening programme was similar to that of the breast cancer screening programme in the same country. There were differences in programme characteristics, including year established (1962-2003 cervical; 1986-2002 breast) and ages covered (15-70+ cervical; 40-75+ breast). Adoption of new screening technologies was evident (44% liquid-based Pap tests; 13% human papillomavirus (HPV)-triage tests cervical; 56% digital mammography breast). There was wide variation in participation rates for both programme types (<4-80% cervical; 12-88% breast), and participation rates tended to be higher for cervical (70-80%) than for breast (60-70%) cancer screening programmes. Eleven ICSN member countries had approved the HPV vaccine and five more were considering its use in their organized programmes. CONCLUSION: Overall, there were similarities and differences in the organization of breast and cervical cancer screening programmes among ICSN countries. This assessment can assist established and new screening programmes in understanding the organization and structure of cancer screening programmes.
Resumo:
A large number of applications using manufactured nanoparticles of less than 100 nm are currently being introduced into industrial processes. There is an urgent need to evaluate the risks of these novel particles to ensure their safe production, handling, use, and disposal. However, today we lack even rudimentary knowledge about type and quantity of industrially used manufactured nanoparticles and the level of exposure in Swiss industry. The goal of this study was to evaluate the use of nanoparticles, the currently implemented safety measures, and the number of potentially exposed workers in all types of industry. To evaluate this, a targeted telephone survey was conducted among health and safety representatives from 197 Swiss companies. The survey showed that nanoparticles are already used in many industrial sectors; not only in companies in the new field of nanotechnology, but also in more traditional sectors, such as paints. Forty-three companies declared to use or produce nanoparticles, and 11 imported and traded with prepackaged goods that contain nanoparticles. The following nanoparticles were found to be used in considerable quantities (> 1000 kg/year per company): Ag, Al-Ox, Fe-Ox, SiO2, TiO2, and ZnO. The median reported quantity of handled nanoparticles was 100 kg/year. The production of cosmetics, food, paints, powders, and the treatment of surfaces used the largest quantities of these nanoparticles. Generally, the safety measures were found to be higher in powder-based than in liquid-based applications. However, the respondents had many open questions about best practices, which points to the need for rapid development of guidelines and protection strategies
Resumo:
This work intends to analyze the behavior of the gas flow of plunger lift wells producing to well testing separators in offshore production platforms to aim a technical procedure to estimate the gas flow during the slug production period. The motivation for this work appeared from the expectation of some wells equipped with plunger lift method by PETROBRAS in Ubarana sea field located at Rio Grande do Norte State coast where the produced fluids measurement is made in well testing separators at the platform. The oil artificial lift method called plunger lift is used when the available energy of the reservoir is not high enough to overcome all the necessary load losses to lift the oil from the bottom of the well to the surface continuously. This method consists, basically, in one free piston acting as a mechanical interface between the formation gas and the produced liquids, greatly increasing the well s lifting efficiency. A pneumatic control valve is mounted at the flow line to control the cycles. When this valve opens, the plunger starts to move from the bottom to the surface of the well lifting all the oil and gas that are above it until to reach the well test separator where the fluids are measured. The well test separator is used to measure all the volumes produced by the well during a certain period of time called production test. In most cases, the separators are designed to measure stabilized flow, in other words, reasonably constant flow by the use of level and pressure electronic controllers (PLC) and by assumption of a steady pressure inside the separator. With plunger lift wells the liquid and gas flow at the surface are cyclical and unstable what causes the appearance of slugs inside the separator, mainly in the gas phase, because introduce significant errors in the measurement system (e.g.: overrange error). The flow gas analysis proposed in this work is based on two mathematical models used together: i) a plunger lift well model proposed by Baruzzi [1] with later modifications made by Bolonhini [2] to built a plunger lift simulator; ii) a two-phase separator model (gas + liquid) based from a three-phase separator model (gas + oil + water) proposed by Nunes [3]. Based on the models above and with field data collected from the well test separator of PUB-02 platform (Ubarana sea field) it was possible to demonstrate that the output gas flow of the separator can be estimate, with a reasonable precision, from the control signal of the Pressure Control Valve (PCV). Several models of the System Identification Toolbox from MATLAB® were analyzed to evaluate which one better fit to the data collected from the field. For validation of the models, it was used the AIC criterion, as well as a variant of the cross validation criterion. The ARX model performance was the best one to fit to the data and, this way, we decided to evaluate a recursive algorithm (RARX) also with real time data. The results were quite promising that indicating the viability to estimate the output gas flow rate from a plunger lift well producing to a well test separator, with the built-in information of the control signal to the PCV
Resumo:
CZE coupled to sheath liquid-based electrospray ionization (ESI) and multiple-stage ion trap mass spectrometry (MS(n) ) was used for the confirmation analysis of ethyl glucuronide (EtG) and ethyl sulfate (EtS) in human serum and urine collected after intake of alcoholic beverages. Electrophoretic separations were performed in uncoated fused-silica capillaries using a pH 9.5 ammonium acetate background electrolyte and normal polarity. MS detection of EtG and EtS occurred after negative ionization using a spray liquid containing 0.5% v/v ammonia in isopropanol/water (60:40%, v/v). CZE-MS and CZE-MS² results obtained after injection of solid-phase extracts for EtG and EtS and of diluted urine confirmed the presence of EtG and EtS in samples whose levels were previously determined by CZE with indirect UV detection. Detection limits of each compound were estimated to be around 2.0 (injection of diluted urine) and 0.2 μg/mL (extracts).
Resumo:
The electrochemical reduction of CO2 has been extensively studied over the past decades. Nevertheless, this topic has been tackled so far only by using a very fundamental approach and mostly by trying to improve kinetics and selectivities toward specific products in half-cell configurations and liquid-based electrolytes. The main drawback of this approach is that, due to the low solubility of CO2 in water, the maximum CO2 reduction current which could be drawn falls in the range of 0.01–0.02 A cm–2. This is at least an order of magnitude lower current density than the requirement to make CO2-electrolysis a technically and economically feasible option for transformation of CO2 into chemical feedstock or fuel thereby closing the CO2 cycle. This work attempts to give a short overview on the status of electrochemical CO2 reduction with respect to challenges at the electrolysis cell as well as at the catalyst level. We will critically discuss possible pathways to increase both operating current density and conversion efficiency in order to close the gap with established energy conversion technologies.
Resumo:
A new method is reported for the synthesis of alkyl aryl sulfones by alkylation of sodium arenesulfinates with unactivated alkyl chlorides using ionic liquid based on 1-butyl-3-methylimidazolium tetrafluoroborate (BmimBF 4) mixed with water (2:1) as reaction media. The ionic liquid can be reused and the procedure gives the sulfones in moderate yields.