995 resultados para Line parameters
Resumo:
We present new optical and infrared photometric observations and high resolution H α spectra of the periodic radio star LSI+61◦303. The optical photometric data set covers the time interval 1985-1993 and amounts to about a hundred nights. A period of ∼26 days is found in the V band. The infrared data also present evidence for a similar periodicity, but with higher amplitude of variation ((0.m 2). The spectroscopic observations include 16 intermediate and high dispersion spectra of LSI+61◦303 collected between January 1989 and February 1993. The H α emission line profile and its variations are analyzed. Several emission line parameters -- among them the H α EW and the width of the H α red hump -- change strongly at or close to radio maximum, and may exhibit periodic variability. We also observe a significant change in the peak separation. The H α profile of LSI+61◦303 does not seem peculiar for a Be star. However, several of the observed variations of the H α profile can probably be associated with the presence of the compact, secondary star.
Resumo:
The radiation characteristics of a microstrip-line-excited rectangular dielectric resonator antenna (DRA) are studied experimentally.The radiation charactristics and excitation of different modes are highly influenced by the orientation of the DR,feed line parameters ,and finite size of the ground plane
Resumo:
The water vapour continuum absorption is an important component of molecular absorption of radiation in atmosphere. However, uncertainty in knowledge of the value of the continuum absorption at present can achieve 100% in different spectral regions leading to an error in flux calculation up to 3-5 W/m2 global mean. This work uses line-by-line calculations to reveal the best spectral intervals for experimental verification of the CKD water vapour continuum models in the currently least studied near-infrared spectral region. Possible sources of errors in continuum retrieval taken into account in the simulation include the sensitivity of laboratory spectrometers and uncertainties in the spectral line parameters in HITRAN-2004 and Schwenke-Partridge database. It is shown that a number of micro-windows in near-IR can be used at present for laboratory detection of the water vapour continuum with estimated accuracy from 30 to 5%.
Resumo:
Intensities and self-broadening coefficients are presented for about 460 of the strongest water vapour lines in the spectral regions 1400–1840 cm−1 and 3440–3970 cm−1 at room temperature, obtained from rather unique measurements using a 5-mm-path-length cell. The retrieved spectral line parameters are compared with those in the HITRAN database ver. 2008 and 2012 and with recent ab-initio calculations. Both the retrieved intensities and half-widths are on average in reasonable agreement with those in HITRAN-2012. Maximum systematic differences do not exceed 4% for intensities (1600 cm−1 band) and 7% for self-broadening coefficients (3600 cm−1 band). For many lines however significant disagreements were detected with the HITRAN-2012 data, exceeding the average uncertainty of the retrieval. In addition, water vapour line parameters for 5300 cm−1 (1.9 μm) band reported by us in 2005 were also compared with HITRAN-2012, and show average differences of 4–5% for both intensities and half-widths.
Resumo:
This article analyzes the electrical parameters of a 3-phase transmission line using a 280-m-high steel tower that has been proposed for the Amazon transmission system in Brazil. The height of the line conductors and the distance between them are intrinsically related to the longitudinal and transverse parameters of the line. Hence, an accurate study is carried out in order to show the electrical variations between a transmission line using the new technology and a conventional 3-phase 440-kV line, considering a wide range of frequencies and variable soil resistivity. First, a brief review of the fundamental theory of line parameters is presented. In addition, by using a digital line model, simulations are carried out in the time domain to analyze possible and critical over-voltage transients on the proposed line representation.
Resumo:
This article shows an analysis of the electrical parameters of a three-phase transmission line section using a relatively new design for steel towers characterized by 280 meters high. These main features, the height of the line conductors and distance between them, are intrinsically related to the longitudinal and transversal parameters of the line. By this means, an analysis was carried out in order to show the electrical variations between a transmission line using the new technology and a conventional 440-kV line through a wide range of frequencies and a variable soil resistivity. © 2012 The Institution of Engineering and Technology.
Resumo:
This article shows an analysis of the longitudinal electric parameters of a three-phase transmission line/section using a 280-meter high steel tower. This characteristic, the height of the line conductors and distance between them, are intrinsic related to the longitudinal and transversal parameters of the line. By this means, an accurate study was carried out in order to show the electric variations between a transmission line using the new technology and a three-phase conventional 440 kV line for a wide range of frequencies and a variable soil resistivity. In addition, by using a digital line model, simulations are carried out in time domain to analyze critical overvoltage transients on the studied line. © 2011 IEEE.
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Pós-graduação em Engenharia Elétrica - FEIS
Resumo:
Pós-graduação em Engenharia Elétrica - FEIS
Resumo:
It is important to ensure smoothly operation of a transmission line, sending energy to the consumption centers with minimal interruptions and safer. With this necessity, the fault location techniques have grown, in order to mitigate the impact of the fault and its correction can be more quickly and accurately. This paper presents a comparison between two different techniques of fault location, the fault location by impedance method, which uses the line parameters, the impedance per distance, voltage and current signals, and the other is the traveling wave method, which uses only a very fast analysis of time, synchronization and length between the line ends, do not using voltage and current values, but the temporal perception of the fault. Using travelling waves fault detection makes the previous knowledge of line parameters obsolete, which helps a lot network technicians and engineers with a quick and easy analysis. The methods are simulated in ATP Draw software, so both algorithms can be evaluated for their effectively and accuracy
Resumo:
It is important to ensure smoothly operation of a transmission line, sending energy to the consumption centers with minimal interruptions and safer. With this necessity, the fault location techniques have grown, in order to mitigate the impact of the fault and its correction can be more quickly and accurately. This paper presents a comparison between two different techniques of fault location, the fault location by impedance method, which uses the line parameters, the impedance per distance, voltage and current signals, and the other is the traveling wave method, which uses only a very fast analysis of time, synchronization and length between the line ends, do not using voltage and current values, but the temporal perception of the fault. Using travelling waves fault detection makes the previous knowledge of line parameters obsolete, which helps a lot network technicians and engineers with a quick and easy analysis. The methods are simulated in ATP Draw software, so both algorithms can be evaluated for their effectively and accuracy
Resumo:
The performance of algorithms for fault location i n transmission lines is directly related to the accuracy of its input data. Thus, fa ctors such as errors in the line parameters, failures in synchronization of oscillographic recor ds and errors in measurements of voltage and current can significantly influence the accurac y of algorithms that use bad data to indicate the fault location. This work presents a new method ology for fault location in transmission lines based on the theory of state estimation in or der to determine the location of faults more accurately by considering realistic systematic erro rs that may be present in measurements of voltage and current. The methodology was implemente d in two stages: pre-fault and post- fault. In the first step, assuming non-synchronized data, the synchronization angle and positive sequence line parameters are estimated, an d in the second, the fault distance is estimated. Besides calculating the most likely faul t distance obtained from measurement errors, the variance associated with the distance f ound is also determined, using the errors theory. This is one of the main contributions of th is work, since, with the proposed algorithm, it is possible to determine a most likely zone of f ault incidence, with approximately 95,45% of confidence. Tests for evaluation and validation of the proposed algorithm were realized from actual records of faults and from simulations of fictitious transmission systems using ATP software. The obtained results are relevant to show that the proposed estimation approach works even adopting realistic variances, c ompatible with real equipments errors.
Resumo:
Kandidaatintyön tarkoituksena oli selvittää pienahitsin juuren kriittisyyttä. Työ oli saanut aiheen rakenneputki kokeiden yhteydessä tehdyistä havainnoista. Työssä tutustuttiin millaiset ovat pienahitsin mitoitus menetelmät ja tausta tutkimusta kuinka sitä sovelletaan käytäntöön suurlujuusteräksille. Työssä esitellään käytetyt tutkimusmenetelmät kuinka menetelmätriangulaatio saavutettiin. Tutkimuskysymyksenä oli hitsien kestävyyden mitoituksen riittävyys. Tutkimukset suoritettiin tarkastellen staattisesti kuormitettuja pienahitsejä. Pienahitsi kappaleista tehtiin laboratoriokoekappale ja FEM-laskentamalli joista vertailtiin tuloksia. Laboratoriokokeessa mittaus menetelmänä käytettiin DIC-mittausta, jolle voitiin tehdä jälkikäsittelyjä ja sieltä määrittää haluttuja datapisteitä. Laskennassa suurimmat jännityskeskittymät syntyivät hitsin kohdalle mutta vetokokeessa koekappaleeseen syntyi vauriot sularajalle ja vetokorvakkeen kiinnityshitsin rajaviivalle. Tällä kohtaa todettiin materiaalimalli riittämättömäksi, koska siihen ei ollut määritelty muutosvyöhykkeen parametreja.