995 resultados para Ligas de titânio zircônio
Resumo:
The copolymer poly (L-co-D,L lactic acid), PLDLA, has gained prominence in the field of temporary prostheses due to the fact that their time of degradation is quite compatible with the requirement in the case of osseous fracture. In this work the in vivo degradation of devices from copolymer, as a system of plates and screws, used in fixation of the tibia of rabbits was studied. The devices were implanted in 15 adult rabbits, albinos, New Zealand race, and they were used as control devices of alloys of titanium (Ti-6Al-4V/ V grade). The use of copolymers, synthesized in the laboratory, was tested in the repair of fracture in rabbits'tibias, being assessed in the following times: 2 weeks, 2 months and 3 months. Morphological analysis of tissue surrounding the plate and screw system, for 2 weeks of implantation, showed the presence of osteoblasts, indicating a pre bone formation. After 2 months there was new bone formation in the region in contact with the polymer. This bone growth occurred simultaneously with the process of PLDLA degradation, invading the region where there was polymer and after 3 months there was an intense degradation of the copolymer and hence greater tissue invasion compared to 2 months which characterized bone formation in a region where the polymer degraded. The in vivo degradation study of the devices for PLDLA by means of histological evaluations during the period of consolidation of the fracture showed the efficiency of plate and screw system, and it was possible to check formation of bone tissue at the implantation site, without the presence of inflammatory reaction
Resumo:
A hidroxiapatita [Ca10(PO4)6(OH)2, HA] foi sintetizada utilizando-se a rota sol-gel partindo-se de ácido fosfórico e nitrato de cálcio como precursores de cálcio e fósforo, respectivamente e como solvente utilizou-se o metanol na preparação do sol que posteriormente será utilizado na obtenção de recobrimentos de hidroxiapatita sobre substratos de ligas de titânio. O sol permaneceu estável e não ocorreu gelatinização em temperatura ambiente durante sete dias. O sol transformou-se em um gel branco somente após a remoção do solvente a 100ºC. O produto assim obtido foi calcinado em 300°C, 500°C e 700°C e caracterizou-se por DRX, FT-IR, MEV/EDS e TGA/DSC. As fases de HA sintetizada tornaram-se estáveis sem sub-produtos a 700°C. A difração de raios X mostrou que a estrutura apatita é aparente em 300°C. O tamanho do cristal e o teor de HA aumentaram com o aumento da temperatura de calcinação. A análise por MEV mostrou a presença de poros que são importantes para aplicações biomédicas, favorecendo a adesão entre o tecido ósseo neoformado e a apatita sintética, ou seja, osseointegração.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Pós-graduação em Engenharia Mecânica - FEG
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de NÃvel Superior (CAPES)
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de NÃvel Superior (CAPES)
Resumo:
O resÃduo do refino da bauxita, comumente conhecido como lama vermelha, tem mostrado ser capaz de ligar metais traços tais como o cobre, cádmio, zinco, cromo, nÃquel e chumbo sob condições apropriadas. A neutralização da lama vermelha é necessária porque essa lama é tipicamente cáustica, com pH em torno de 13. Muitas pesquisas têm sido desenvolvidas envolvendo a utilização da lama vermelha, porque contem uma série de elementos valiosos. Assim a utilização da lama vermelha como material de construção e como adsorvente é atrativa porque ela é utilizada em grande quantidade. Nada pode ser feito sem descartar componentes valiosos como titânio, zircônio e principalmente ferro. A sÃntese de hidrotalcita conectada com a reciclagem de soluções alcalinas representa uma maneira efetiva de uso dessa solução considerando a forte demanda por proteção ambiental no mundo. Os compostos tipo hidrotalcita, precipitados durante a neutralização da lama, também removem oxi-ânions de metais de transição através da combinação de intercalações e adsorção de espécies aniônicas na sua superfÃcie externa. Os hidróxidos duplos lamelares (HDL) vêm sendo investigados à muitos anos como materiais hospedeiros para uma variedade de reações de intercalação de anions. A estrutura lamelar dos HDLs pode ser usada para controlar a adição ou remoção de uma variedade de espécies quÃmicas, tanto orgânicas quanto inorgânicas. Isto é alcançado através de sua habilidade de adaptar a separação das lamelas de hidróxidos, e da reatividade da região interlamelar. O material resultante adsorve anions quando colocado em soluções e reverte a estrutura da hidrotalcita. Avanços significativos têm sido alcançados recentemente na caracterização desses materiais, incluindo estudos estruturais sobre o mecanismo de intercalação. O objetivo desse trabalho foi a sÃntese e caracterização de HDLs a partir da lama vermelha, e testar esses materiais como adsorventes de metais pesados.
Resumo:
Titanium and its alloys have been used for biomedical applications due their excellent properties such as high corrosion resistance, biocompatibility and mechanical properites. In this study, microstructural and mechanical properties of Ti-30Ta alloy was evaluated during its processing. Ti-30Ta alloy ingots were produced from sheets of commercially pure titanium (99.9%) and tantalum (99.9%). Its melting was realized in arc melting furnace in an argon atmosphere. After homogenizing at 1200ºC, ingots were cold worked by swaging. Samples with 13 mm in diameter were obtained. They were forging at the reduction ratios of 15%. After deformation, microstructure was evaluated by optical microscopy in each condition. Also, Vickers microhardness of samples was measured and phase constitution was evaluated using XRD analysis
Resumo:
As they have excellent mechanical properties, corrosion resistance and biocompatibility, much research has been conducted with respect to biomedical applications of titanium alloys. This work aims to study the experimental system binary alloy Ti-15Mo, in the raw state of fusion and heat treatment after homogenization, solubilization and calcination (simulating conditions employed for nanotube growth) targeting biomedical applications. Samples were obtained by casting the components in an electric arc furnace with inert atmosphere of argon. After obtaining the alloy, it was heat treated at three different heat treatments, namely homogenizing, calcining and simulation solubilization. The phases present were analyzed by X-ray diffraction, optical microscopy and microhardness testing
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de NÃvel Superior (CAPES)
Resumo:
Various surface treatments of dental implants have been developed in order to ensure anchorage to bone tissue, optimization of the determinants of electronic structure, crystallinity, composition and properties. Coating techniques have been proposed in order tocreate unionbiochemicalable to accelerate the early stages ofbone tissue, combining the positive properties of titanium and its alloys bioactivity of ceramic materials. This paper discusses protocol for handling the SBF coating of titanium alloys. The apatite phase nucleation occurs by immersing the substrate in synthetic solution simulating blood plasma (Simulated Body Fluid). The protocol allows manipulation of the SBF solution to establish guidelines regarding the usestreamlinedand organized to make practical application.
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de NÃvel Superior (CAPES)
Resumo:
Surface treatments have been used to modify the surface of titanium alloys. The purpose of this study is to evaluate the surface of Ti-30Ta alloy after biomimetic approach associated to antibiotic incorporation. The ingots were obtained in arc melting furnace, treated and cold-worked by swaging. The surface treatment was performed in two steps: biomimetic treatment and antibiotic incorporation. For biomimetic treatment, first an alkaline treatment (NaOH 1M at 60ºC) was performed, followed by heat treatment and immersion in SBFx5 (Simulated Body Fluid) for a period of 24 hours. In order to incorporate the antibiotic, samples were immersed in a solution formed by drugs plus SBFx5 for 48 hours. The sample surfaces were analyzed by scanning electron microscopy (SEM), X-Ray diffraction (XRD), atomic force microscopy (AFM) and contact angle measurements. The release of antibiotic from coated implants was measured in phosphate buffer saline at pH 7.4 by using UV/VIS spectrometry. Results have shown changes on the surface after incorporating the drug, which is gradually co-precipitated with the Ca-P crystals, forming a uniform and rough layer on the metal surface