928 resultados para Leg Length
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
A 3-year-old, male crossbred dog with osteomyelitis of the radius and ulna was treated using Ilizarov's method. Two centimeters of infected bone was resected, then acute bone shortening and subsequent lengthening of a healthy bone site were performed. The infection was eradicated, but a residual leg-length discrepancy was present.
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
O objetivo deste trabalho foi avaliar o efeito do fotoperíodo e da raça nas características de carcaça de cordeiros machos Hampshire Down e Santa Inês. Sete cordeiros Hampshire Down e sete Santa Inês foram submetidos a fotoperíodo de 12 horas luz x 12 horas escuro (curto) e de 18 horas luz x 6 horas escuro (longo). Após o desmame, os cordeiros foram alojados em baias individuais de acordo com os tratamentos. Ao atingirem 31 kg de peso vivo, foram abatidos e a carcaça e os componentes não-constituintes da carcaça foram pesados. Cordeiros Santa Inês apresentaram peso de carcaça quente superior ao dos Hampshire e maior rendimento comercial. Cordeiros Santa Inês apresentaram maior peso de sangue, coração, pulmão, rins e baço. Já os cordeiros Hampshire Down apresentaram pesos de pele, patas e aparelho gastrintestinal cheio superiores aos do Santa Inês. Os cordeiros Santa Inês apresentaram maior largura de garupa e comprimento de perna do que os Hampshire Down. Os cordeiros Santa Inês apresentaram porcentagem de costela descoberta e baixos maior do que os Hampshire Down, com maior porcentagem de perna. A raça influencia mais as características de carcaça do que o fotoperíodo.
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
The present study aimed to evaluate the performance, survivability and carcass traits of crossbred lambs. Data from 299 lambs born to 209 ewes were used. The dams were from a local hair breed (Santa Inês) and five breeds of sires were used: Dorper (DR), Ile de France (IF), Hampshire Down (HD), Texel (TX) and Santa Inês (SI). The lambs were weighed at birth, weaning and slaughter. Fasting body weight, skin thickness, hot and cold carcass weight, carcass yield and carcass length were measured at slaughter. Carcasses were separated into commercial cuts: neck, shoulder, rib, belly, loin and leg. Leg length and circumference were measured. Analyses of variances using MIXED procedure in SAS® were carried out for weights and carcass traits. Factor, discriminant and canonical analysis were carried out. Mortality data of animals from birth until slaughter was analyzed using logistic regression. The HD animals had the highest mortality rate. TX lambs had similar growth rate and survivability compared to DR and IF and had better carcass traits than these genetic groups. Therefore, this breed can be used as paternal breed to crossbreeding with Santa Inês dams. Santa Inês animals did not differ in growth from birth until slaughter compared to crossbred animals, which highlights the potential of this naturalized breed for meat production. Moreover, there is a great variability inside this breed for carcass and growth traits which may undergo great improvement through selection programs. © 2013 Elsevier B.V.
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Male dimorphism of a neotropical arachnid: harem size, sneaker opportunities, and gonadal investment
Resumo:
Serracutisoma proximum is a harvestman with alternative male morphs. Large males use sexually dimorphic second legs in fights for the possession of territories on the vegetation, where females oviposit. Small males have short second legs and do not fight but rather sneak into the territories and copulate with egg-guarding females. We investigated the presence of male dimorphism across 10 populations of S. proximum, compared gonadal investment between male morphs, and assessed if the distribution of the sneakers is influenced by harem size. In all populations, there was male dimorphism, indicated by the bimodal distribution of the leg II length/body length. Gonadal investment did not differ between morphs and was not affected by male size, second leg length, and morph relative frequency in the populations. We found 361 territories, 90.0% containing 1 male, 9.7% containing 2 males (dyads), and 0.3% containing 3 males. The probability of encountering dyads increased with the number of females present in the territories. Moreover, the proportion of sneakers in territories containing dyads was higher than would be expected by chance. One possible reason for the ubiquity of alternative morphs in S. proximum could be the high mating opportunities experienced by sneakers in spatially structured populations with a resource defense polygyny system. Additionally, the high frequency of successful invasions by sneakers and hence the high sperm competition risk for both morphs may explain the similarity in gonadal investment between male morphs.
Resumo:
This paper presents a novel technique to create a computerized fluoroscopy with zero-dose image updates for computer-assisted fluoroscopy-based close reduction and osteosynthesis of diaphyseal fracture of femurs. With the novel technique, repositioning of bone fragments during close fracture reduction will lead to image updates in each acquired imaging plane, which is equivalent to using several fluoroscopes simultaneously from different directions but without any X-ray radiation. Its application facilitates the whole fracture reduction and osteosynthesis procedure when combining with the existing leg length and antetorsion restoration methods and may result in great reduction of the X-ray radiation to the patient and to the surgical team. In this paper, we present the approach for achieving such a technique and the experimental results with plastic bones.
Resumo:
Component malpositioning and postoperative leg length discrepancy are the most common technical problems associated with total hip arthroplasty (THA). Surgical navigation offers the potential to reduce the incidence of these problems. We reviewed 317 patients (344 hips) that underwent THA using computed tomography-based surgical navigation, including 112 THAs using a simplified method of measuring leg length. Guided by the navigation system, cups were placed in 40.8 degrees +/- 2 degrees of operative abduction (range, 35 degrees -50 degrees) and 30.8 degrees +/- 3.2 degrees (range, 19 degrees -43 degrees) of operative anteversion. We subsequently measured radiographic abduction on plain anteroposterior pelvic radiographs and calculated abduction and anteversion. Radiographically, 97.1 % of the cups were in the safe zone for abduction and 92.4% for anteversion. The mean incision length was less than 8 cm for 327 of the 344 hips. Leg length change measured intraoperatively was 6.6 +/- 4.1 mm (range, -2-22), similar to measurements from the pre- and postoperative magnification-corrected radiographs. Computer assistance during THA increased the consistency of component positioning and allowed reliable measurement of leg length change during surgery.
Resumo:
OBJECTIVE The aim of the therapy is mechanical and functional stabilization of high dislocated hips with dysplasia coxarthrosis using total hip arthroplasty (THA). INDICATIONS Developmental dysplasia of the hip (DDH) in adults, symptomatic dysplasia coxarthrosis, high hip dislocation according to Crowe type III/IV, and symptomatic leg length inequality. CONTRAINDICATIONS Cerebrospinal dysfunction, muscular dystrophy, apparent disturbance of bone metabolism, acute or chronic infections, and immunocompromised patients. SURGICAL TECHNIQUE With the patient in a lateral decubitus position an incision is made between the anterior border of the gluteus maximus muscle and the posterior border of the gluteus medius muscle (Gibson interval). Identification of the sciatic nerve to protect the nerve from traction disorders by visual control. After performing trochanter flip osteotomy, preparation of the true actetabulum if possible. Implantation of the reinforcement ring, preparation of the femur and if necessary for mobilization, resection until the trochanter minor. Test repositioning under control of the sciatic nerve. Finally, refixation of the trochanteric crest. POSTOPERATIVE MANAGEMENT During hospital stay, intensive mobilization of the hip joint using a continuous passive motion machine with maximum flexion of 70°. No active abduction and passive adduction over the body midline. Maximum weight bearing 10-15 kg for 8 weeks, subsequently, first clinical and radiographic follow-up and deep venous thrombosis prophylaxis until full weight bearing. RESULTS From 1995 to 2012, 28 THAs of a Crow type IV high hip-dislocation were performed in our institute. Until now 14 patients have been analyzed during a follow-up of 8 years in 2012. Mid-term results showed an improvement of the postoperative clinical score (Merle d'Aubigné score) in 86 % of patients. Good to excellent results were obtained in 79 % of cases. Long-term results are not yet available. In one case an iatrogenic neuropraxia of the sciatic nerve was observed and after trauma a redislocation of the arthroplasty appeared in another case. In 2 cases an infection of the THA appeared 8 and 15 months after index surgery. No pseudoarthrosis of the trochanter or aseptic loosening was noticed.
Resumo:
PURPOSE Despite the fact that new and modern short-stems allow bone sparing and saving of soft-tissue and muscles, we still face the challenge of anatomically reconstructing the femoro-acetabular offset and leg length. Therefore a radiological and clinical analysis of a short-stem reconstruction of the femoro-acetabular offset and leg length was performed. METHODS Using an antero-lateral approach, the optimys short-stem (Mathys Ltd, Bettlach, Switzerland) was implanted in 114 consecutive patients in combination with a cementless cup (Fitmore, Zimmer, Indiana, USA; vitamys RM Pressfit, Mathys Ltd, Bettlach, Switzerland). Pre- and postoperative X-rays were done in a standardized technique. In order to better analyse and compare X-ray data a special double coordinate system was developed for measuring femoral- and acetabular offset. Harris hip score was assessed before and six weeks after surgery. Visual analogue scale (VAS) satisfaction, leg length difference and the existence of gluteal muscle insufficiency were also examined. RESULTS Postoperative femoral offset was significantly increased by a mean of 5.8 mm. At the same time cup implantation significantly decreased the acetabular offset by a mean of 3.7 mm, which resulted in an increased combined femoro-acetabular offset of 2.1 mm. Postoperatively, 81.7 % of patients presented with equal leg length. The maximum discrepancy was 10 mm. Clinically, there were no signs of gluteal insufficiency. No luxation occurred during hospitalization. The Harris hip score improved from 47.3 before to 90.1 points already at six weeks after surgery while the mean VAS satisfaction was 9.1. CONCLUSION The analysis showed that loss of femoro-acetabular offset can be reduced with an appropriate stem design. Consequently, a good reconstruction of anatomy and leg length can be achieved. In the early postoperative stage the clinical results are excellent.
Resumo:
This chapter proposed a personalized X-ray reconstruction-based planning and post-operative treatment evaluation framework called iJoint for advancing modern Total Hip Arthroplasty (THA). Based on a mobile X-ray image calibration phantom and a unique 2D-3D reconstruction technique, iJoint can generate patient-specific models of hip joint by non-rigidly matching statistical shape models to the X-ray radiographs. Such a reconstruction enables a true 3D planning and treatment evaluation of hip arthroplasty from just 2D X-ray radiographs whose acquisition is part of the standard diagnostic and treatment loop. As part of the system, a 3D model-based planning environment provides surgeons with hip arthroplasty related parameters such as implant type, size, position, offset and leg length equalization. With this newly developed system, we are able to provide true 3D solutions for computer assisted planning of THA using only 2D X-ray radiographs, which is not only innovative but also cost-effective.
Resumo:
The development of functional legged robots has encountered its limits in human-made actuation technology. This paper describes research on the biomimetic design of legs for agile quadrupeds. A biomimetic leg concept that extracts key principles from horse legs which are responsible for the agile and powerful locomotion of these animals is presented. The proposed biomimetic leg model defines the effective leg length, leg kinematics, limb mass distribution, actuator power, and elastic energy recovery as determinants of agile locomotion, and values for these five key elements are given. The transfer of the extracted principles to technological instantiations is analyzed in detail, considering the availability of current materials, structures and actuators. A real leg prototype has been developed following the biomimetic leg concept proposed. The actuation system is based on the hybrid use of series elasticity and magneto-rheological dampers which provides variable compliance for natural motion. From the experimental evaluation of this prototype, conclusions on the current technological barriers to achieve real functional legged robots to walk dynamically in agile locomotion are presented.