999 resultados para Large screens


Relevância:

30.00% 30.00%

Publicador:

Resumo:

Systematic natural ventilation effects on measured temperatures within a standard large wooden thermometer screen are investigated under summer conditions, using well-calibrated platinum resistance thermometers. Under low ventilation (2mwind speed u2 < 1.1 m s−1), the screen slightly underestimates daytime air temperature but overestimates air temperature nocturnally by 0.2◦C. The screen’s lag time L lengthens with decreasing wind speed, following an inverse power law relationship between L and u2. For u2 > 2 m s−1, L ∼ 2.5 min, increasing, when calm, to at least 15 min. Spectral response properties of the screen to air temperature fluctuations vary with wind speed because of the lag changes. Ventilation effects are particularly apparent at the higher (>25◦C) temperatures, both through the lag effect and from solar heating. For sites where wind speed decreases with increasing daytime temperature, thermometer screen temperatures may consequently show larger uncertainties at the higher temperatures. Under strong direct beam solar radiation (>850W m−2) the radiation effect is likely to be <0.4◦C. Copyright c 2011 RoyalMeteorological Society

Relevância:

30.00% 30.00%

Publicador:

Resumo:

BACKGROUND: Early detection of colorectal cancer through timely follow-up of positive Fecal Occult Blood Tests (FOBTs) remains a challenge. In our previous work, we found 40% of positive FOBT results eligible for colonoscopy had no documented response by a treating clinician at two weeks despite procedures for electronic result notification. We determined if technical and/or workflow-related aspects of automated communication in the electronic health record could lead to the lack of response. METHODS: Using both qualitative and quantitative methods, we evaluated positive FOBT communication in the electronic health record of a large, urban facility between May 2008 and March 2009. We identified the source of test result communication breakdown, and developed an intervention to fix the problem. Explicit medical record reviews measured timely follow-up (defined as response within 30 days of positive FOBT) pre- and post-intervention. RESULTS: Data from 11 interviews and tracking information from 490 FOBT alerts revealed that the software intended to alert primary care practitioners (PCPs) of positive FOBT results was not configured correctly and over a third of positive FOBTs were not transmitted to PCPs. Upon correction of the technical problem, lack of timely follow-up decreased immediately from 29.9% to 5.4% (p<0.01) and was sustained at month 4 following the intervention. CONCLUSION: Electronic communication of positive FOBT results should be monitored to avoid limiting colorectal cancer screening benefits. Robust quality assurance and oversight systems are needed to achieve this. Our methods may be useful for others seeking to improve follow-up of FOBTs in their systems.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

REV3, the catalytic subunit of translesion polymerase zeta (polζ), is commonly associated with DNA damage bypass and repair. Despite sharing accessory subunits with replicative polymerase δ, very little is known about the role of polζ in DNA replication. We previously demonstrated that inhibition of REV3 expression induces persistent DNA damage and growth arrest in cancer cells. To reveal determinants of this sensitivity and obtain insights into the cellular function of REV3, we performed whole human genome RNAi library screens aimed at identification of synthetic lethal interactions with REV3 in A549 lung cancer cells. The top confirmed hit was RRM1, the large subunit of ribonucleotide reductase (RNR), a critical enzyme of de novo nucleotide synthesis. Treatment with the RNR-inhibitor hydroxyurea (HU) synergistically increased the fraction of REV3-deficient cells containing single stranded DNA (ssDNA) as indicated by an increase in replication protein A (RPA). However, this increase was not accompanied by accumulation of the DNA damage marker γH2AX suggesting a role of REV3 in counteracting HU-induced replication stress (RS). Consistent with a role of REV3 in DNA replication, increased RPA staining was confined to HU-treated S-phase cells. Additionally, we found genes related to RS to be significantly enriched among the top hits of the synthetic sickness/lethality (SSL) screen further corroborating the importance of REV3 for DNA replication under conditions of RS.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

As a consequence of cinema screens being placed in front of screen-speakers, a reduction in sound quality has been noticed. Cinema screens not only let the sound go through them, but also absorb a small amount of it and reflect the sound which impacts on the screen to the back, coming forward again in case it impacts on the loudspeaker. This backwards reflection in addition to the signal coming from the loudspeaker can lead to constructive or destructive interference at certain frequencies which usually results in comb filtering. In this project, this effect has been studied through researching amongst various data sheet provided by different manufacturers, acoustical measurements completed in the large anechoic chamber of the ISVR and some theoretical models developed with MatLab software. If results obtained with MatLab are accurate enough in comparison to the real measurements taken in the anechoic chamber this would lead to a good way to predict which would be the attenuation added to the system at each frequency, given that not all manufacturers provide an attenuation curve, but only an average attenuation. This average attenuation might be useless as sound waves have different wavelengths and its propagation through partitions varies. In fact, sound is composed by high and low frequencies, where high frequencies are characterised by a small wavelength which is usually easier to attenuate than low frequencies that characterised by bigger wavelengths. Furthermore, this information would be of great value to both screen manufacturers, who could offer a much more precise data in their data sheets; and customers, who would have a great amount of information to their disposal before purchasing and installing anything in their cinemas, being able to know by themselves which screen or loudspeaker should be best to meet their expectative. RESUMEN. La aparición de la digitalización de las bandas sonoras para las películas hace posible la mejora en la calidad de sonido de los cines. Sin embargo, un aspecto a tener en cuenta en esta calidad del sonido es la transmisión de éste a través de la pantalla, ya que normalmente tras ella se encuentran situados los altavoces. Las propiedades acústicas varían dependiendo del tipo de pantalla que se utilice, además de haber poca información a la que acceder para poder valorar su comportamiento. A lo largo de este proyecto, se analizan tres muestras de pantallas distintas donadas por distintos fabricantes para poder llegar a la conclusión de dependiendo del tipo de pantalla cuál es la distancia óptima a la que localizar la pantalla respecto al altavoz y con qué inclinación. Dicho análisis se realizó en la cámara anecoica del ISVR (University of Southampton) mediante la construcción de un marco de madera de 2x2 m en el que tensar las pantallas de cine, y un altavoz cuyo comportamiento sea el más similar al de los altavoces de pantalla reales. Los datos se captaron mediante cuatro micrófonos colocados en posiciones distintas y conectados al software Pulse de Brüel & Kjær, a través del cual se obtuvieron las respuestas en frecuencia del altavoz sin pantalla y con ella a diferentes distancias del altavoz. Posteriormente, los datos se analizaron con MatLab donde se calculó la atenuación, el factor de transmisión de la presión (PTF) y el análisis cepstrum. Finalmente, se realizó un modelo teórico del comportamiento de las pantallas perforadas basado en las placas perforadas utilizadas para atenuar el sonido entre distintas habitaciones. Como conclusión se llegó a que las pantallas curvadas son acústicamente más transparentes que las pantallas perforadas que a partir de 6 kHz son más acústicamente opacas. En las pantallas perforadas la atenuación depende del número de perforaciones por unidad de área y el diámetro de éstas. Dicha atenuación se reducirá si se reduce el diámetro de las perforaciones de la pantalla, o si se incrementa la cantidad de perforaciones. Acerca del efecto filtro peine, para obtener la mínima amplitud de éste la pantalla se deberá situar a una distancia entre 15 y 30 cm del altavoz, encontrando a la distancia de 30 cm que la última reflexión analizada a través de Cepstrum llega 5 ms más tarde que la señal directa, por lo cual no debería dañar el sonido ni la claridad del habla.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

We have undertaken an extensive screen to identify Saccharomyces cerevisiae genes whose products are involved in cell cycle progression. We report the identification of 113 genes, including 19 hypothetical ORFs, which confer arrest or delay in specific compartments of the cell cycle when overexpressed. The collection of genes identified by this screen overlaps with those identified in loss-of-function cdc screens but also includes genes whose products have not previously been implicated in cell cycle control. Through analysis of strains lacking these hypothetical ORFs, we have identified a variety of new CDC and checkpoint genes.