282 resultados para LARMOR PRECESSION
Resumo:
It is believed that eta Carinae is actually a massive binary system, with the wind-wind interaction responsible for the strong X-ray emission. Although the overall shape of the X-ray light curve can be explained by the high eccentricity of the binary orbit, other features like the asymmetry near periastron passage and the short quasi-periodic oscillations seen at those epochs have not yet been accounted for. In this paper we explain these features assuming that the rotation axis of eta Carinae is not perpendicular to the orbital plane of the binary system. As a consequence, the companion star will face eta Carinae on the orbital plane at different latitudes for different orbital phases and, since both the mass-loss rate and the wind velocity are latitude dependent, they would produce the observed asymmetries in the X-ray flux. We were able to reproduce the main features of the X-ray light curve assuming that the rotation axis of eta Carinae forms an angle of 29 degrees +/- 4 degrees with the axis of the binary orbit. We also explained the short quasi-periodic oscillations by assuming nutation of the rotation axis, with an amplitude of about 5 degrees and a period of about 22 days. The nutation parameters, as well as the precession of the apsis, with a period of about 274 years, are consistent with what is expected from the torques induced by the companion star.
Resumo:
Evidence of jet precession in many galactic and extragalactic sources has been reported in the literature. Much of this evidence is based on studies of the kinematics of the jet knots, which depends on the correct identification of the components to determine their respective proper motions and position angles on the plane of the sky. Identification problems related to fitting procedures, as well as observations poorly sampled in time, may influence the follow-up of the components in time, which consequently might contribute to a misinterpretation of the data. In order to deal with these limitations, we introduce a very powerful statistical tool to analyse jet precession: the cross-entropy method for continuous multi-extremal optimization. Only based on the raw data of the jet components (right ascension and declination offsets from the core), the cross-entropy method searches for the precession model parameters that better represent the data. In this work we present a large number of tests to validate this technique, using synthetic precessing jets built from a given set of precession parameters. With the aim of recovering these parameters, we applied the cross-entropy method to our precession model, varying exhaustively the quantities associated with the method. Our results have shown that even in the most challenging tests, the cross-entropy method was able to find the correct parameters within a 1 per cent level. Even for a non-precessing jet, our optimization method could point out successfully the lack of precession.
Resumo:
In this paper, we show that the steady-state free precession sequence can be used to acquire (13)C high-resolution nuclear magnetic resonance spectra and applied to qualitative analysis. The analysis of brucine sample using this sequence with 60 degrees flip angle and time interval between pulses equal to 300 ms (acquisition time, 299.7 ms; recycle delay, 300 ms) resulted in spectrum with twofold enhancement in signal-to-noise ratio, when compared to standard (13)C sequence. This gain was better when a much shorter time interval between pulses (100 ms) was applied. The result obtained was more than fivefold enhancement in signal-to-noise ratio, equivalent to more than 20-fold reduction in total data recording time. However, this short time interval between pulses produces a spectrum with severe phase and truncation anomalies. We demonstrated that these anomalies can be minimized by applying an appropriate apodization function and plotting the spectrum in the magnitude mode.
Resumo:
Using the Feynman procedure of ordered exponential operators we solve the evolution equations for a two-neutrino system considering arbitrarily varying matter density and magnetic field along the neutrino trajectory. We show that a large geometrical phase velocity suppresses νL→νR transitions unless some stationary trajectory is found along the neutrino path. Concerning the solar neutrino case, if we admit the standard solar model matter distribution, no such trajectory can be found.
Resumo:
We report on four years of observations of 3C 273 at 7mm obtained with the Itapetinga radio telescope, in Brazil, between 2009 and 2013. We detected a flare in 2010 March, when the flux density increased by 50 per cent and reached 35 Jy. After the flare, the flux density started to decrease and reached values lower than 10 Jy. We suggest that the 7-mm flare is the radio counterpart of the γ -ray flare observed by the Fermi Large Area Telescope in 2009 September, in which the flux density at high energies reached a factor of 50 of its average value. A delay of 170 d between the radio and γ -ray flares was revealed using the discrete correlation function (DCF) that can be interpreted in the context of a shock model, in which each flare corresponds to the formation of a compact superluminal component that expands and becomes optically thin at radio frequencies at latter epochs. The differences in flare intensity between frequencies and at different times are explained as a consequence of an increase in the Doppler factor δ, as predicted by the 16-yr precession model proposed by Abraham & Romero. This increase has a large effect on boosting at high frequencies while it does not affect the observed optically thick radio emission too much. We discuss other observable effects of the variation in δ, such as the increase in the formation rate of superluminal components, the variations in the time delay between flares and the periodic behaviour of the radio light curve that we have found to be compatible with changes in the Doppler factor.
Resumo:
Diese Arbeit beschreibt die Entwicklung, Konstruktion und Untersuchung eines Magnetometers zur exakten und präzisen Messung schwacher Magnetfelder. Diese Art von Magnetometer eignet sich zur Anwendung in physikalischen hochpräzisions Experimenten wie zum Beispiel der Suche nach dem elektrischen Dipolmomentrndes Neutrons. Die Messmethode beruht auf der gleichzeitigen Detektion der freien Spin Präzession Kern-Spin polarisierten 3He Gases durch mehrere optisch gepumpte Cäsium Magnetometer. Es wird gezeigt, dass Cäsium Magnetometer eine zuverlässige und vielseitige Methode zur Messung der 3He Larmor Frequenz und eine komfortable Alternative zur Benutzung von SQUIDs für diesen Zweck darstellen. Ein Prototyp dieses Magnetometers wurde gebaut und seine Funktion in der magnetisch abgeschirmten Messkabine der Physikalisch Technischen Bundesanstalt untersucht. Die Sensitivität des Magnetometers in Abhängigkeitrnvon der Messdauer wurde experimentell untersucht. Es wird gezeigt, dass für kurze Messperioden (< 500s) Cramér-Rao limitierte Messungen möglich sind während die Sensitivität bei längeren Messungen durch die Stabilität des angelegten Magnetfeldes limitiert ist. Messungen eines 1 muT Magnetfeldes mit einer relative Genauigkeit von besser als 5x10^(-8) in 100s werden präsentiert. Es wird gezeigt, dass die Messgenauigkeit des Magnetometers durch die Zahl der zur Detektion der 3He Spin Präzession eingesetzten Cäsium Magnetometer skaliert werden kann. Prinzipiell ist dadurch eine Anpassung der Messgenauigkeit an jegliche experimentellen Bedürfnisse möglich. Es wird eine gradiometrische Messmethode vorgestellt, die es erlaubt den Einfluss periodischerrnmagnetischer Störungen auf dieMessung zu unterdrücken. Der Zusammenhang zwischen der Sensitivität des kombinierten Magnetometers und den Betriebsparametern der Cäsium Magnetometer die zur Spin Detektion verwendet werden wird theoretisch untersucht und anwendungsspezifische Vor- und Nachteile verschiedener Betriebsartenwerden diskutiert. Diese Zusammenhänge werden in einer Formel zusammengefasst die es erlaubt, die erwartete Sensitivität des Magnetometers zu berechnen. Diese Vorhersagen befinden sich in perfekter Übereinstimmung mit den experimentellen Daten. Die intrinsische Sensitivität des Magnetometer Prototyps wird auf Basis dieser Formel theoretisch bestimmt. Ausserdem wird die erwartete Sensitivität für die Anwendung im Rahmen des Experiments der nächsten Generation zur Bestimmung des elektrischenrnDipolmoments des Neutrons am Paul Scherrer Institut abgeschätzt. Des weiteren wird eine bequeme experimentelle Methode zur Messung des Polarisationsgrades und des Rabi Flip-Winkels der 3He Kernspin Polarisation vorgestellt. Letztere Messung ist sehr wichtig für die Anwendung in hochpräzisions Experimenten.
Resumo:
To evaluate a new isotropic 3D proton-density, turbo-spin-echo sequence with variable flip-angle distribution (PD-SPACE) sequence compared to an isotropic 3D true-fast-imaging with steady-state-precession (True-FISP) sequence and 2D standard MR sequences with regard to the new 3D magnetic resonance observation of cartilage repair tissue (MOCART) score.
Resumo:
OBJECT: Fat suppressed 3D steady-state free precession (SSFP) sequences are of special interest in cartilage imaging due to their short repetition time in combination with high signal-to-noise ratio. At low-to-high fields (1.5-3.0 T), spectral spatial (spsp) radio frequency (RF) pulses perform superiorly over conventional saturation of the fat signal (FATSAT pulses). However, ultra-high fields (7.0 T and more) may offer alternative fat suppression techniques as a result of the increased chemical shift. MATERIALS AND METHODS: Application of a single, frequency selective, RF pulse is compared to spsp excitation for water (or fat) selective imaging at 7.0 T. RESULTS: For SSFP, application of a single frequency selective RF pulse for selective water or fat excitation performs beneficially over the commonly applied spsp RF pulses. In addition to the overall improved fat suppression, the application of single RF pulses leads to decreased power depositions, still representing one of the major restrictions in the design and application of many pulse sequences at ultra-high fields. CONCLUSION: The ease of applicability and implementation of single frequency selective RF pulses at ultra-high-fields might be of great benefit for a vast number of applications where fat suppression is desirable or fat-water separation is needed for quantification purposes.
Resumo:
The formerly proposed concept for magnetization transfer imaging (MTI) using balanced steady-state free precession (SSFP) image acquisitions is in this work extended to nonbalanced protocols. This allows SSFP-based MTI of targets with high susceptibility variation (such as the musculoskeletal system), or at ultra-high magnetic fields (where balanced SSFP suffers from considerable off-resonance related image degradations). In the first part, SSFP-based MTI in human brain is analyzed based on magnetization transfer ratio (MTR) histograms. High correlations are observed among all different SSFP MTI protocols and thereby ensure proper conceptual extension to nonbalanced SSFP. The second part demonstrates SSFP-based MTI allowing fast acquisition of high resolution volumetric MTR data from human brain and cartilage at low (1.5T) to ultra-high (7.0T) magnetic fields.
Resumo:
PURPOSE: To prospectively assess the diagnostic accuracy of nonenhanced three-dimensional (3D) steady-state free precession (SSFP) magnetic resonance (MR) angiography for detection of renal artery stenosis (RAS), with breath-hold contrast material-enhanced MR angiography performed as the reference standard. MATERIALS AND METHODS: The study was local ethics committee approved; all patients gave written informed consent. Fifty-three patients (30 male, 23 female; mean age, 58 years) with arterial hypertension and suspected of having RAS were examined with 1.5-T 3D SSFP renal MR angiography. Stenosis grade, maximal visible vessel length, and subjective image quality were compared. Sensitivity, specificity, accuracy, and negative predictive value (NPV) were calculated on artery-by-artery and patient-by-patient bases. The significance of the results was assessed with the paired two-sided t test for continuous variables and with the marginal homogeneity test for categorical variables. Cohen kappa statistics were used to estimate interobserver agreement. RESULTS: One hundred eight renal arteries with 20 significant (>or=50%) stenoses were detected with contrast-enhanced MR angiography. At artery-by-artery analysis, sensitivity, specificity, accuracy, and NPV of nonenhanced SSFP MR angiography for RAS detection were 100%, 93%, 94%, and 100%, respectively, for observer 1 and 95%, 95%, 95%, and 99%, respectively, for observer 2. Corresponding patient-by-patient values were 100%, 92%, 94%, and 100%, respectively, for observer 1 and 100%, 95%, 96%, and 100%, respectively, for observer 2. Overestimation of stenosis grade with SSFP MR angiography resulted in six and four false-positive findings for readers 1 and 2, respectively. Mean maximal visible lengths of the renal arteries were 69.9 mm at contrast-enhanced MR angiography and 61.1 mm at SSFP MR angiography (P<.001). Both techniques yielded good to excellent image quality. CONCLUSION: Slab-selective inversion-prepared 3D SSFP MR angiography had high sensitivity, specificity, accuracy, and NPV for RAS detection, without the need for contrast material. However, RAS severity was overestimated in some patients.
Resumo:
INTRODUCTION: Cartilage defects are common pathologies and surgical cartilage repair shows promising results. In its postoperative evaluation, the magnetic resonance observation of cartilage repair tissue (MOCART) score, using different variables to describe the constitution of the cartilage repair tissue and the surrounding structures, is widely used. High-field magnetic resonance imaging (MRI) and 3-dimensional (3D) isotropic sequences may combine ideal preconditions to enhance the diagnostic performance of cartilage imaging.Aim of this study was to introduce an improved 3D MOCART score using the possibilities of an isotropic 3D true fast imaging with steady-state precession (True-FISP) sequence in the postoperative evaluation of patients after matrix-associated autologous chondrocyte transplantation (MACT) as well as to compare the results to the conventional 2D MOCART score using standard MR sequences. MATERIAL AND METHODS: The study had approval by the local ethics commission. One hundred consecutive MR scans in 60 patients at standard follow-up intervals of 1, 3, 6, 12, 24, and 60 months after MACT of the knee joint were prospectively included. The mean follow-up interval of this cross-sectional evaluation was 21.4 +/- 20.6 months; the mean age of the patients was 35.8 +/- 9.4 years. MRI was performed at a 3.0 Tesla unit. All variables of the standard 2D MOCART score where part of the new 3D MOCART score. Furthermore, additional variables and options were included with the aims to use the capabilities of isotropic MRI, to include the results of recent studies, and to adapt to the needs of patients and physician in a clinical routine examination. A proton-density turbo spin-echo sequence, a T2-weighted dual fast spin-echo (dual-FSE) sequence, and a T1-weighted turbo inversion recovery magnitude (TIRM) sequence were used to assess the standard 2D MOCART score; an isotropic 3D-TrueFISP sequence was prepared to evaluate the new 3D MOCART score. All 9 variables of the 2D MOCART score were compared with the corresponding variables obtained by the 3D MOCART score using the Pearson correlation coefficient; additionally the subjective quality and possible artifacts of the MR sequences were analyzed. RESULTS: The correlation between the standard 2D MOCART score and the new 3D MOCART showed for the 8 variables "defect fill," "cartilage interface," "surface," "adhesions," "structure," "signal intensity," "subchondral lamina," and "effusion"-a highly significant (P < 0.001) correlation with a Pearson coefficient between 0.566 and 0.932. The variable "bone marrow edema" correlated significantly (P < 0.05; Pearson coefficient: 0.257). The subjective quality of the 3 standard MR sequences was comparable to the isotropic 3D-TrueFISP sequence. Artifacts were more frequently visible within the 3D-TrueFISP sequence. CONCLUSION: In the clinical routine follow-up after cartilage repair, the 3D MOCART score, assessed by only 1 high-resolution isotropic MR sequence, provides comparable information than the standard 2D MOCART score. Hence, the new 3D MOCART score has the potential to combine the information of the standard 2D MOCART score with the possible advantages of isotropic 3D MRI at high-field. A clear limitation of the 3D-TrueFISP sequence was the high number of artifacts. Future studies have to prove the clinical benefits of a 3D MOCART score.