956 resultados para L-ASCORBIC-ACID


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Poor sperm viability post-thaw has resulted in constant research into methods of cryopreservation of canine semen. One factor that may be involved in poor viability is sperm oxidative stress caused by excessive formation of reactive oxygen species. The present study was performed in order to evaluate the effect of different concentrations of ascorbic acid (AA) and glutathione (Glu) added to an extender for the freeze-thawing of dog sperm. Semen from five mature dogs was collected and frozen in two studies. Prior to and after freezing, sperm motility, morphology and membrane status were examined. In addition, sperm motility was examined up to 120 min after thawing to evaluate thermo-resistance. In study I, semen was collected twice from each dog. On both occasions, semen was divided into three aliquots: control, Glu 1 mM and Glu 5 mM. In study II, semen was collected twice and divided into three aliquots; control, AA 50 mu M and AA 250 mu M. Initial sperm motility was significantly higher in sperm diluted with AA 50 mu M; sperm longevity, however, measured by a thermal-resistance test (TRT), was higher for Glu treatments. Higher concentration of Glu produced significant improvement in TRT and membrane status, whereas higher concentration of AA had a negative impact in sperm longevity. Antioxidant supplementation to semen freezing extenders improved semen quality post-thaw. Moreover, Glu had the most beneficial effect when supplemented at 5 mM.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Ascorbic acid is found in many food samples. Its clinical and technological importance demands an easyto- use, rapid, robust and inexpensive method of analysis. For this purpose, this work proposes a new flow procedure based on the oxidation of ascorbic acid by periodate. A new potentiometric periodate sensor was constructed to monitor this reaction. The selective membranes were of PVC with porphyrin-based sensing systems and a lipophilic cation as additive. The sensor displayed a near-Nernstian response for periodate over 1.0x10-2–6.0x10-6 M, with an anionic slope of 73.9 ± 0.9 mV decade-1. It was pH independent in acidic media and presented good selectivity features towards several inorganic anions. The flow set-up operated in double-channel, carrying a 5.0x10-4 M IO- 4 solution and a suitable buffer; these were mixed in a 50-cm reaction coil. The overall flow rate was 7 ml min-1 and the injection volume 70 µl. Under these conditions, a linear behaviour against concentration was observed for 17.7–194.0 µg ml-1, presenting slopes of 0.169 mV (mg/l)-1, a reproducibility of ±1.1 mV (n = 5), and a sampling rate of ~96 samples h-1. The proposed method was applied to the analysis of beverages and pharmaceuticals.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

BACKGROUND Fragile X syndrome (FXS) is an inherited neurodevelopmental condition characterised by behavioural, learning disabilities, physical and neurological symptoms. In addition, an important degree of comorbidity with autism is also present. Considered a rare disorder affecting both genders, it first becomes apparent during childhood with displays of language delay and behavioural symptoms.Main aim: To show whether the combination of 10 mg/kg/day of ascorbic acid (vitamin C) and 10 mg/kg/day of α-tocopherol (vitamin E) reduces FXS symptoms among male patients ages 6 to 18 years compared to placebo treatment, as measured on the standardized rating scales at baseline, and after 12 and 24 weeks of treatment.Secondary aims: To assess the safety of the treatment. To describe behavioural and cognitive changes revealed by the Developmental Behaviour Checklist Short Form (DBC-P24) and the Wechsler Intelligence Scale for Children-Revised. To describe metabolic changes revealed by blood analysis. To measure treatment impact at home and in an academic environment. METHODS/DESIGN A phase II randomized, double-blind pilot clinical trial. SCOPE male children and adolescents diagnosed with FXS, in accordance with a standardized molecular biology test, who met all the inclusion criteria and none of the exclusion criteria. INSTRUMENTATION clinical data, blood analysis, Wechsler Intelligence Scale for Children-Revised, Conners parent and teacher rating scale scores and the DBC-P24 results will be obtained at the baseline (t0). Follow up examinations will take place at 12 weeks (t1) and 24 weeks (t2) of treatment. DISCUSSION A limited number of clinical trials have been carried out on children with FXS, but more are necessary as current treatment possibilities are insufficient and often provoke side effects. In the present study, we sought to overcome possible methodological problems by conducting a phase II pilot study in order to calculate the relevant statistical parameters and determine the safety of the proposed treatment. The results will provide evidence to improve hyperactivity control and reduce behavioural and learning problems using ascorbic acid (vitamin C) and α-tocopherol (vitamin E). The study protocol was approved by the Regional Government Committee for Clinical Trials in Andalusia and the Spanish agency for drugs and health products. TRIAL REGISTRATION ClinicalTrials.gov Identifier: NCT01329770 (29 March 2011).

Relevância:

100.00% 100.00%

Publicador:

Resumo:

An amperometric sensor was constructed, by using humic acids to immobilize Fe3+ ions on a carbon paste electrode (CPE-HA-Fe), and used for ascorbic acid (H2A) determination. The cyclic voltammogram of the electrode showed electrochemical response due to the Fe3+/Fe2+ couple at E1/2=+0.78 V vs SCE, using 0.5 mol L-1 KCl and 0.2 mol L-1 acetate/0.020 mol L-1 phosphate buffer, at pH = 5.4, as supporting electrolyte. When H2A is added to the electrolyte solution it is observed an oxidation process. The oxidation current, obtained by chronoamperommetry at +0.87 V vs SCE, is proportional to the concentration, represented by the equation I(µA) = 7.6286 [H2A] (mmol L-1) + 1.9583, r = 0.9996, for concentrations between 0.0 and 1.4 mmol L-1. The electrode showed high stability and was used for H2A determination in a natural orange juice.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Sixty Piaractus mesopotamicus Holmberg, 1887 (pacu) fry fed a diet containing 0, 50, 100 and 200 mg ascorbic acid/kg dry feed were studied to evaluate the effect on parasitic infestation by the monogenean Anacanthorus penilabiatus Boeger, Husak and Martins, 1995 (Monogenea: Dactylogyridae) for a period of 24 weeks. The temperature of the aquaria was measured daily and remained between 28 and 31oC. At the beginning of the experiment, fish showed 6.15 ± 0.33 cm standard length and 8.64 ± 1.62 g average body weight. A sample of fish was examined and showed 43 ± 17 monogeneans per fish. At the end of the experiment, the gills of control and vitamin C-treated fish were collected for parasite counts. Control fish had 42.5 parasites per fish, a significantly higher number (P<0.05) when compared with fish fed vitamin C, that showed 16.5 parasites per fish. Ascorbic acid fortification in the food promoted an increase in fish resistance to parasites. It is suggested that an optimum level of 139 mg/kg vitamin C supplementation either elicited better nutritional conditions by stimulating the appetite of the fish or improved the immune response.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Mallow leaves (Malva sylvestris L.) with initial moisture of 5.02±0.003 on dry basis (82.5% on wet basis) were dried using three different drying methods, microwave, convective and vacuum. The leaves that weigh 75 g each were dried until their moisture fell down to 0.10±0.005 on dry basis (approximately 9% on wet basis). The following drying levels were used in each of the drying processes: 6.67, 8.67, 10, 11.33 W g-1 microwave power density; 50, 75, 100 and 125 °C for convective drying; and 3, 7 kPa at 50 and 75 °C for vacuum drying. Drying periods ranged from 6-10, 26-150 and 38-130 min. for microwave, convective and vacuum drying, respectively. Effective moisture diffisuvities ranged from 2.04403 10-10-3.63996 10-12 m2 s-1, 1.70182 10-11-1.10084 10-10 m2 s-1 and 1.85599 10-11-5.94559 10-10 m2 s-1 for microwave, convective and vacuum drying, respectively. According to ascorbic acid content and color parameters, the best microwave power density was found 10 W g-1 with a drying period of 6.5 min.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Two vanadium(V) complexes, [VO(L-1)]acac)] (1) and [VO(L-2)(acac)] (2), where H2L1 = N,N-bis(2-hydroxy-3-5-di-tert-butyl-benzyl)propylamine and H2L2 = 2,2'-selenobis(4,6-di-tert-butylphenol), have been synthesized and characterized by elemental analyses, IR, V-51 NMR, both in the solid and in solution, and cyclic voltammetric studies. Single crystal X-ray studies reveal that in complex 1 the vanadium atom is octahedrally coordinated with an O5N donor environment, where the oxygen atom of the V-V=O moiety and the N atom of the ONO ligand occupy the axial sites while two oxygen atoms (O1 and O2) from the bisphenolate ligand and two oxygen atoms (O3 and O4) from the acac ligand occupy the equatorial plane. A similar bonding pattern has also been encountered for 2 with the exception that a Se atom instead of N is involved in weak bonding to the metal center. Both complexes showed reversible cyclic voltammeric responses and E-1/2 appears at -0.18 and 0.10 V versus NHE for complexes 1 and 2, respectively. The kinetics of oxidation of ascorbic acid by complex 1 were carried out in 50% MeCN-50% HO (v/v) at 25 degrees C. The high formation constant value, Q = 63 +/- 7 M-1, reveals that the reaction proceeds through the rapid formation of a H-bonded intermediate. The low k(2)Q(2)/k(1)Q(1) ratio (13.4) for 1 points out that there is extensive H-bonding between the oxygen atom of the V-V=O group and the OH group of ascorbic acid. (c) 2007 Published by Elsevier Ltd.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Two cobalt complexes, [Co(L-Se)(phen)]center dot CH2Cl2 (1) and [Co(L-Se)(N,N-Me(2)en)(CH3COO-)] (2) have been synthesized and characterized by elemental analyses, magnetic measurements, i.r. studies etc. Single crystal X- ray studies reveal that in complex (1) cobalt atom is in +2 oxidation state with trigonal bipyramidal geometry, while in complex (2) it is in +3 oxidation state and surrounded octahedrally. The asymmetric unit of complex (2) contains two crystallographically independent discrete molecules. Complex (1) was found to be paramagnetic with mu(eff) = 2.19 BM indicating a low spin cobalt(II) d(7) system, whereas complex (2) is found to be diamagnetic with cobalt(III) in low spin d(6) state. The kinetic studies on the reduction of (2) by ascorbic acid in 80% MeCN-20% H2O (v/v) at 25 degrees C reveal that the reaction proceeds through the rapid formation of inner-sphere adduct, probably by replacing the loosely coordinated AcO- group, followed by electron transfer in a slow step and is supported by a large Q (formation constant) value.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Background & aims: Pregnancy is a period characterized by high metabolic requirements and physiological changes in the female organism. During this period, Low body stores of vitamins and minerals including antioxidants can have adverse effects on the mother and foetus. This cross-sectional. study assessed plasma concentrations of ascorbic acid (AA) in 117 parturients admitted into a university hospital in S (a) over tildeo Paulo city, Brazil. Methods: The concentrations of AA were determined by the high performance liquid chromatographic method. Data concerning socioeconomic, demographic, obstetric and nutritional characteristics of the parturients were collected by a standardized questionnaire. Results: The prevalence of AA deficiency (< 22.7 mu mol/L) among the parturients was 30.8%. Mean plasma AA concentrations were lower in single/divorced women (27.84 +/- 3.48 mu mol./L) compared with married/single with partner women (34.78 +/- 1.85 mu mol/L) (p = 0.047). Blood AA concentrations were significantly correlated with per capita income (r = 0.36, p < 0.001) and vitamin C-rich food intake score (r = 0.42, p < 0.001). Conclusion: The high prevalence of hypovitaminosis C detected in this study is probably due to an inadequate intake of foods rich in vitamin C and tow income. We alert to the need for increasing the intake of vitamin C-rich foods through educational. programs, especially for tow income populations. (c) 2007 Elsevier Ltd and European Society for Clinical Nutrition and Metabolism. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Pyrolytic graphite electrodes (PGE) were modified into dopamine solutions using phosphate buffer solutions, pH 10 and 6.5, as supporting electrolyte. The modification process involved a previous anodization of the working electrode at +1. 5 V into 0. 1 mol-L-1 NaOH followed by other anodization step, in the same experimental conditions, into dopamine (DA) solutions. pH of the supporting electrolyte performed an important role in the production of a superficial melanin polymeric film, which permitted the simultaneous detection of ascorbic acid (AA), (DA) and uric acid (UA), Delta EAA-DA = 222 mV-, Delta EAA-UA = 360 mV and Delta EDA-UA=138mV, avoiding the superficial poisoning effects. The calculated detection limits were: 1.4 x 10(-6) mol L-1 for uric acid, 1.3x10-(5) molL(-1) for ascorbic acid and 1.1 X 10(-7) mol L-1 for dopamine, with sensitivities of (7.7 +/- 0.5), (0.061 +/- 0.001) and (9.5 +/- 0.05)A mol(-1) cm(-2), respectively, with no mutual interference. Uric acid was determined in urine, blood and serum human samples after dilution in phosphate buffer and no additional sample pre-treatment was necessary. The concentration of uric acid in urine was higher than the values found in blood and serum and the recovery tests (92-102%) indicated that no matrix effects were observed. (C) 2008 Elsevier B.V. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The anodic oxidation of ascorbic acid on a ruthenium oxide hexacyanoferrate modified electrode was characterized by cyclic voltammetry. On this modified surface, the electrocatalytic process allows the determination of ascorbic acid to be performed at 0.0 V and pH 6.9 with a limit of detection of 2.2 mu M in a flow injection configuration. Under this experimental condition, no interference from glucose, nitrite and uric acid was noticed. Lower detection limit values were obtained by measuring flow injection analysis (FIA) responses at 0.4 V (0.14 mu M), but a concurrent loss of selectivity is expected at this more positive potential. Under optimal FIA operating conditions, the linear response of the method was extended up to 1 mM ascorbic acid. The repeatability of the method for injections of a 1.0 mM ascorbic acid solution was 2.0% (n=10). The usefulness of the method was demonstrated by an addition-recovery experiment with urine samples and the recovered values were in the 98-104% range. (c) 2007 Elsevier B.V. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This work describes the development, electrochemical characterization and utilization of a cobalt phthalocyanine modified carbon nanotube electrode for the quantitative determination of dopamine in 0.2 mol L-1 phosphate buffer contaminated with high concentration of ascorbic acid. The electrode surface was analyzed by cyclic voltammetry and electrochemical impedance spectroscopy which showed a modified surface presenting a charge transfer resistance of 500 Omega, against the 16.46 k Omega value found for the bare glassy carbon surface. A pseudo rate constant value of 5.4 x 10(-4) cm s(-1) for dopamine oxidation was calculated. Voltammetric experiments showed a shift of the peak potential of DA oxidation to less positive value at 390 mV as compared with that of a bare GC electrode at 570 mV. The electrochemical determination of dopamine, in presence of ascorbic acid in concentrations up to 0.1 mol L-1 by differential pulse voltarnmetry, yielded a detection limit as low as 2.56 x 10(-7) mol L-1.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A cathodically pretreated boron-doped diamond electrode was used for the simultaneous anodic determination of ascorbic acid (AA) and caffeine (CAF) by differential pulse voltammetry Linear calibration curves (r = 0 999) were obtained from 1 9 x 10(-5) to 2 I x 10(-4) mol L(-1) for AA and from 9 7 x 10(-6) to 1 1 x 10-4 mol L(-1) for CAF. with detection limits of 19 wool L(-1) and 7 0 mu nol L(-1). respectively This method was successfully applied for the determination of AA and CAF in pharmaceutical formulations. with results equal to those obtained using a HPLC reference method

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)