834 resultados para Joint replacement
Resumo:
Objective. To determine out-of-pocket expenditures related to osteoarthritis (OA) and to explore whether demographic details, health status scores (Medical Outcomes Study 36-item Short Form [SF-36] and Western Ontario and McMaster Universities Osteoarthritis Index [WOMAC]), or perception of social effect were expenditure determinants. Methods. A prospective cohort study of community-dwelling subjects with OA completed 4 consecutive 3-month cost diaries. In addition, subjects completed the SF-36 and WOMAC at baseline and at 12 months. Social impact at baseline was collected. Four groups categorized by age and sex were compared. Patients undergoing joint replacement were excluded. Results. Differences in health status were defined more by age than by sex, especially for physical function. The costs to the patients were high, particularly for women, who spent more on medications and special equipment. Women also reported receiving more assistance from family and friends. Higher disease-related expenditures were associated with greater pain levels, poorer social function and mental health, and longer duration of disease. Significant independent predictors of total patient expenditures related to OA were being female and having joint stiffness. Conclusion. Despite having heavily subsidized health care and access to the Pharmaceutical Benefits Scheme, out-of-pocket costs for patients with OA in Australia are considerable. Higher expenditures for patients with OA are related to more advanced disease, especially for women.
Resumo:
skeletal disease. Bone remodeling is initiated by osteoclastic resorption followed by osteoblastic formation of new bone. Receptor activator of nuclear factor KB ligand (RANKL) is a newly described regulator of osteoclast formation and function, the activity of which appears to be a balance between interaction with its receptor RANK and with an antagonist binding protein osteoprotegerin (OPG). Therefore, we have examined the relationship between the expression of RANKL, RANK, and OPG and indices of bone structure and turnover in human cancellous bone from the proximal femur. Bone samples were obtained from individuals with osteoarthritis (OA) at joint replacement surgery and from autopsy controls. Histomorphometric analysis of these samples showed that eroded surface (ES/BS) and osteoid surface (OS/BS) were positively associated in both control (p < 0.001) and OA (p < 0.02), indicating that the processes of bone resorption and bone formation remain coupled in OA, as they are in controls. RANKL, OPG, and RANK messenger RNA, (mRNA) were abundant in human cancellous bone, with significant differences between control and OA individuals. In coplotting the molecular and histomorphometric data, strong associations were found between the ratio of RANKL/OPG mRNA and the indices of bone turnover (RANKL/OPG vs. ES/BS: r = 0.93, p < 0.001; RANKL/OPG vs. OS/BS: r = 0.80, p < 0.001). These relationships were not evident in trabecular bone from severe OA, suggesting that bone turnover may be regulated differently in this disease. We propose that the effective concentration of RANKL is related causally to bone turnover.
Resumo:
This is the first report of surface-active phospholipid as the boundary lubricant in total hip arthroplasty. Aspirate and rinsings from the bearing surfaces of 25 revision operations and one primary surgery were analyzed from 3 weeks to 26 years postoperatively. All samples contained substantial amounts of surface-active phospholipids ranging from 14 to 4186 μg. These findings indicate that synoviocytes continue producing the lubricant in significant quantities after arthroplasty surgery independent of the type of joint replacement and its fixation. Surface-active phospholipid was found on all bearing surfaces analyzed including polyethylene, stainless steel, chrome cobalt, alumina, zirconia, and titanium.
Resumo:
Background: Mobile-bearing knee replacements have some theoretical advantages over fixed-bearing devices. However, very few randomized controlled clinical trials have been published to date, and studies showed little clinical and subjective advantages for the mobile-bearing using traditional systems of scoring. The choice of the ideal outcome measure to assess total joint replacement remains a complex issue. However, gait analysis provides objective and quantifying evidences of treatment evaluation. Significant methodological advances are currently made in gait analysis laboratories and ambulatory gait devices are now available. The goal of this study was to provide gait parameters as a new objective method to assess total knee arthroplasty outcome between patients with fixed- and mobile-bearing, using an ambulatory device with minimal sensor configuration. Methods: This randomized controlled double-blind study included to date 31 patients: the gait signatures of 12 patients with mobile-bearing were compared to the gait signatures of 19 patients with fixed-bearing pre-operatively and post-operatively at 6 weeks, 3 months and 6 months. Each participant was asked to perform two walking trials of 30m long at his/her preferred speed and to complete a EQ-5D questionnaire, a WOMAC and Knee Society Score (KSS). Lower limbs rotations were measured by four miniature angular rate sensors mounted respectively, on each shank and thigh. Results: Better relative differences between pre-operative and post-operative 3 months and 6 months KSS (122% vs 34% at 3 months, 138% vs 36% at 6 months) and KSS function (154% vs 8% at 3 months, 183% vs 42% at 6 months) scores were observed for the fixed-bearing compared to the mobile-bearing. The same better improvements for fixed-bearing were also found with the range of knee angles (Affected side: 31% vs -5% at 3 months, 47% vs 5% at 6 months), (Unaffected side: 16% vs 5% at 3 months, 15% vs 6% at 6 months) and peak swing speeds of shank (Affected side: 18% vs -2% at 3 months, 30% vs 4% at 6 months), (Unaffected side: 8% vs -3% at 3 months, 7% vs 4% at 6 months). Conclusions: A new method for a portable system for gait analysis has been developed with very encouraging results regarding the objective outcome of total knee arthroplasty using mobile- and fixed-bearings.
Resumo:
Background: Mobile-bearing knee replacements have some theoretical advantages over fixed-bearing devices. However, very few randomized controlled clinical trials have been published to date, and studies showed little clinical and subjective advantages for the mobile-bearing using traditional systems of scoring. The choice of the ideal outcome measure to assess total joint replacement remains a complex issue. However, gait analysis provides objective and quantifying evidences of treatment evaluation. Significant methodological advances are currently made in gait analysis laboratories and ambulatory gait devices are now available. The goal of this study was to provide gait parameters as a new objective method to assess total knee arthroplasty outcome between patients with fixed- and mobile-bearing, using an ambulatory device with minimal sensor configuration. This randomized controlled double-blind study included to date 14 patients: the gait signatures of four patients with mobile-bearing were compared to the gait signatures of nine patients with fixed-bearing pre-operatively and post-operatively at 6 weeks, 3 months and 6 months. Each participant was asked to perform two walking trials of 30m long at his/her preferred speed and to complete a EQ-5D questionnaire, a WOMAC and Knee Society Score (KSS). Lower limbs rotations were measured by four miniature angular rate sensors mounted respectively, on each shank and thigh. A new method for a portable system for gait analysis has been developed with very encouraging results regarding the objective outcome of total knee arthroplasty using mobile- and fixed-bearings.
Resumo:
BACKGROUND: An objective measurement of surgical procedures outcomes is inherent to professional practices quality control; this especially applies in orthopaedics to joint replacement outcomes. A self-administered questionnaire offers an attractive alternative to surgeon's judgement but is infrequently used in France for these purposes. The British questionnaire, the 12-item Oxford Hip Score (OHS) was selected for this study because of its ease of use. HYPOTHESIS: The objective of this study was to validate the French translation of the self-assessment 12-item Oxford Hip Score and compare its results with those of the reference functional scores: the Harris Hip Score (HHS) and the Postel-Merle d'Aubigné (PMA) score. MATERIALS AND METHODS: Based on a clinical series of 242 patients who were candidates for total hip arthroplasty, the French translation of this questionnaire was validated. Its coherence was also validated by comparing the preoperative data with the data obtained from the two other reference clinical scores. RESULTS: The translation was validated using the forward-backward translation procedure from French to English, with correction of all differences or mistranslations after systematized comparison with the original questionnaire in English. The mean overall OHS score was 43.8 points (range, 22-60 points) with similarly good distribution of the overall value of the three scores compared. The correlation was excellent between the OHS and the HHS, but an identical correlation between the OHS and the PMA was only obtained for the association of the pain and function parameters, after excluding the mobility criterion, relatively over-represented in the PMA score. DISCUSSION AND CONCLUSION: Subjective questionnaires that contribute a personal appreciation of the results of arthroplasty by the patient can easily be applied on a large scale. This study made a translated and validated version of an internationally recognized, reliable self-assessment score available to French orthopaedic surgeons. The results obtained encourage us to use this questionnaire as a complement to the classical evaluation scores and methods.
Resumo:
Progressive pseudorheumatoid dysplasia (PPRD) is a genetic, non-inflammatory arthropathy caused by recessive loss of function mutations in WISP3 (Wnt1-inducible signaling pathway protein 3; MIM 603400), encoding for a signaling protein. The disease is clinically silent at birth and in infancy. It manifests between the age of 3 and 6 years with joint pain and progressive joint stiffness. Affected children are referred to pediatric rheumatologists and orthopedic surgeons; however, signs of inflammation are absent and anti-inflammatory treatment is of little help. Bony enlargement at the interphalangeal joints progresses leading to camptodactyly. Spine involvement develops in late childhood and adolescence leading to short trunk with thoracolumbar kyphosis. Adult height is usually below the 3rd percentile. Radiographic signs are relatively mild. Platyspondyly develops in late childhood and can be the first clue to the diagnosis. Enlargement of the phalangeal metaphyses develops subtly and is usually recognizable by 10 years. The femoral heads are large and the acetabulum forms a distinct "lip" overriding the femoral head. There is a progressive narrowing of all articular spaces as articular cartilage is lost. Medical management of PPRD remains symptomatic and relies on pain medication. Hip joint replacement surgery in early adulthood is effective in reducing pain and maintaining mobility and can be recommended. Subsequent knee joint replacement is a further option. Mutation analysis of WISP3 allowed the confirmation of the diagnosis in 63 out of 64 typical cases in our series. Intronic mutations in WISP3 leading to splicing aberrations can be detected only in cDNA from fibroblasts and therefore a skin biopsy is indicated when genomic analysis fails to reveal mutations in individuals with otherwise typical signs and symptoms. In spite of the first symptoms appearing in early childhood, the diagnosis of PPRD is most often made only in the second decade and affected children often receive unnecessary anti-inflammatory and immunosuppressive treatments. Increasing awareness of PPRD appears to be essential to allow for a timely diagnosis. © 2012 Wiley Periodicals, Inc.
Resumo:
Travail d'intégration réalisé dans le cadre du cours PHT-6113.
Resumo:
En estados unidos se realizaron 200.000 reemplazos de cadera en el 2001, de los cuales 36.000 fueron cirugías de revisión. La incidencia de infección en primarios es del 1% mientras que en revisión es 4% . Es determinante detectar la presencia o no de infección, sin embargo no existe una prueba 100% sensible ni 100% especifica. El cultivo intraoperatorio es el patrón de oro, pero inoportuno para tomar decisiones intraoperatorias. La biopsia por congelación es un estudio histopatológico que ayuda a determinar infección intraoperatoria.
Resumo:
Introducción Los Grupos Relacionados de Diagnóstico (GRD) se han usado para determinar la calidad de la atención en varios sistemas de salud. Esto ha llevado a que se obtengan resultados en el mejoramiento continuo de la atención y del cuidado. El objetivo de este estudio es determinar desenlaces clínicos de los pacientes a quienes se les había realizado reemplazo de articulares según la complejidad clínica definida mediante GRD. Métodos Se realizó un estudio longitudinal descriptivo en el cual se incluyeron todos los pacientes que tuvieron cirugía de reemplazo total de hombro, cadera y rodilla entre 2012 y 2014. Se realizó la estratificación de los pacientes de acuerdo a tres niveles de complejidad dados por el sistema de GRD y se determinaron las proporciones de pacientes para las variables de estancia hospitalaria, enfermedad trombo-embólica, cardiovascular e infección del sitio operatorio. Resultados Se realizaron en total 886 reemplazos articulares de los cuales 40 (4.5%) presentaron complicaciones. Los eventos más frecuentes fueron las complicaciones coronarias, con una presencia de 2.4%. El GRD1, sin complicaciones ni comorbilidades, fue el que presentó mayor número de eventos. La estancia hospitalaria fue de 3.8 a 9.3 días para todos los reemplazos. Conclusiones Contrario a lo planteado en la hipótesis de estudio, se encontró que el primer GRD presentó el mayor número de complicaciones, lo que puede estar relacionado con el tamaño del grupo. Es necesario realizar nuevas investigaciones que soporten el uso de los GRD como herramienta para evaluar desenlaces clínicos.
Resumo:
Introducción: La hipotermia perioperatoria se ha documentado como factor de riesgo para el aumento de la morbimortalidad de los pacientes aumentando morbilidad miocárdica, riesgo de infección, pérdidas sanguíneas y tiempo de hospitalización. La aplicación de anestésicos toma relevancia ya que causa la pérdida de control central de la temperatura. Nuestro objetivo con este estudio fue describir la proporción de casos de hipotermia en la población sometida a un reemplazo articular durante un periodo de cuatro meses. Materiales y métodos: Se realizó un estudio de cohorte prospectivo. La población a estudio fueron los pacientes que fueron sometidos a un reemplazo total de cadera, rodilla u hombro. Se registró la temperatura central en el momento previo a la inducción anestésica, 30, 60 y 90 minutos después, al finalizar el procedimiento y al ingresar a recuperación. Se reportó el porcentaje de pacientes con hipotermia en cada tiempo. Resultados: Se analizaron en total 88 pacientes, el 55,7% fue llevado a cirugía de cadera, 39,7% de rodilla y 4,5% de hombro. El tipo de anestesia más utilizado fue general y la duración promedio de anestesia fue 164 minutos. La medición de la temperatura central se realizó en nasofaringe, esófago o tímpano. La proporción de pacientes que presentaron hipotermia en la inducción fue 21,6%, a 30 minutos 83%, a 60 minutos 73,9%, a 90 minutos 68,2%, al finalizar 59,1% y en recuperación 58%. Se realizó una prueba Chi cuadrado comparando las proporciones entre la inducción y los cinco periodos posteriores, se encontró que la proporción de pacientes con hipotermia en los cinco tiempos posteriores tuvo una diferencia estadísticamente significativa (p=0,00) comparada con la proporción de pacientes con hipotermia durante la inducción. Conclusión: En los pacientes sometidos a un reemplazo articular la hipotermia fue una condición prevalente posterior a la aplicación de los anestésicos sistémicos. Los dispositivos de calentamiento intraoperatorio usados actualmente son insuficientes para evitar la hipotermia, lo que indica concordancia con la literatura en cuanto a las recomendaciones de calentamiento perioperatorio, con énfasis en el precalentamiento, para prevenir la caída significativa de la temperatura y la morbimortalidad asociada.
Resumo:
Automotive parts manufacture by machining process using silicon nitride-based ceramic tool development in Brazil already is a reality. Si 3N4-based ceramic cutting tools offer a high productivity due to their excellent hot hardness, which allows high cutting speeds. Under such conditions the cutting tool must be resistant to a combination of mechanical, thermal and chemical attacks. Silicon nitride based ceramic materials constitute a mature technology with a very broad base of current and potential applications. The best opportunities for Si3N 4-based ceramics include ballistic armor, composite automotive brakes, diesel particulate filters, joint replacement products and others. The goal of this work was to show latter advance in silicon nitride manufacture and its recent evolution on machining process of gray cast iron, compacted graphite iron and Ti-6Al-4V. Materials characterization and machining tests were analyzed by X-Ray Diffraction, Scanning Electron Microscopy, Vickers hardness and toughness fracture and technical norm. In recent works the authors has been proved to advance in microstructural, mechanical and physic properties control. These facts prove that silicon nitride-based ceramic has enough resistance to withstand the impacts inherent to the machining of gray cast iron (CI), compacted graphite iron (CGI) and Ti-6Al-4V (6-4). Copyright © 2008 SAE International.
Resumo:
In uncemented Ti6Al4V hip implants, the bone-stem interface is subjected to cyclic loading motion driven by the daily activities of the patients, which may lead to the complete failure of the implant in the long term. It may also compromise the proliferation and differentiation processes of osteoblastic cells (bone-forming cells). The main objective of this work is to approach for the first time the role of these organic materials on the bio-tribocorrosion mechanisms of cultured Ti6Al4V alloys. The colonized materials with MG63 osteoblastic-like cells were characterized through cell viability/proliferation and enzymatic activity. Tribocorrosion tests were performed under a reciprocating sliding configuration and low contact pressure. Electrochemical techniques were used to measure the corrosion kinetics of the system, under free potential conditions. All tests were performed at a controlled atmosphere. The morphology and topography of the wear scar were evaluated. The results showed that the presence of an osteoblastic cell layer on the implant surface significantly influences the tribocorrosion behavior of Ti6Al4V alloy. It was concluded that the cellular material was able to form an extra protective layer that inhibits further wear degradation of the alloy and decreases its corrosion tendency.
Resumo:
OBJETIVOS: Avaliar os resultados funcionais iniciais e o índice de complicações precoces das artroplastias totais do quadril cerâmica-cerâmica em pacientes que convivem com o HIV e apresentam osteonecrose da cabeça femoral. MÉTODO: Doze pacientes HIV+ com diagnóstico de osteonecrose da cabeça do fêmur incongruente foram avaliados através de critérios clínicos, laboratoriais, pela escala funcional WOMAC antes e após o tratamento com substituição articular. RESULTADOS: Observamos que 83,3% dos indivíduos faziam uso de inibidores de protease, 75% apresentavam dislipidemia e 66,6% síndrome lipodistrófica, a melhora na evolução no escore WOMAC foi estatisticamente significativa para seis e 12 meses de pós-operatório em comparação com o escore pré-operatório e não observamos complicações secundárias a esse procedimento. CONCLUSÃO: A artroplastia total do quadril com implante de cerâmica-cerâmica para o tratamento da necrose avascular do quadril nessa parcela da população é opção cirúrgica adequada, apresenta melhora funcional inicial significativa e baixo índice de complicação precoce.
Resumo:
The revision hip arthroplasty is a surgical procedure, consisting in the reconstruction of the hip joint through the replacement of the damaged hip prosthesis. Several factors may give raise to the failure of the artificial device: aseptic loosening, infection and dislocation represent the principal causes of failure worldwide. The main effect is the raise of bone defects in the region closest to the prosthesis that weaken the bone structure for the biological fixation of the new artificial hip. For this reason bone reconstruction is necessary before the surgical revision operation. This work is born by the necessity to test the effects of bone reconstruction due to particular bone defects in the acetabulum, after the hip prosthesis revision. In order to perform biomechanical in vitro tests on hip prosthesis implanted in human pelvis or hemipelvis a practical definition of a reference frame for these kind of bone specimens is required. The aim of the current study is to create a repeatable protocol to align hemipelvic samples in the testing machine, that relies on a reference system based on anatomical landmarks on the human pelvis. In chapter 1 a general overview of the human pelvic bone is presented: anatomy, bone structure, loads and the principal devices for hip joint replacement. The purpose of chapters 2 is to identify the most common causes of the revision hip arthroplasty, analysing data from the most reliable orthopaedic registries in the world. Chapter 3 presents an overview of the most used classifications for acetabular bone defects and fractures and the most common techniques for acetabular and bone reconstruction. After a critical review of the scientific literature about reference frames for human pelvis, in chapter 4, the definition of a new reference frame is proposed. Based on this reference frame, the alignment protocol for the human hemipelvis is presented as well as the statistical analysis that confirm the good repeatability of the method.