972 resultados para Jaw Apparatus
Resumo:
Technical images such as photography, film and video, are dependent on apparatuses for their production and dissemination, yet the apparatus itself is often hidden or obscured in the experience of the work and the discourse that surrounds it. This practice-led research identifies key practice strategies to foreground the apparatus both in the production of work and in its presentation. It therefore develops critical and generative strategies to explore and interrogate the workings of the 'apparatus-audience complex,' and the particular modes of spectatorship that this entails.
Resumo:
In the present study, variation in the morphology of the lower pharyngeal element between two Sicilian populations of the rainbow wrasse Coris julis has been explored by the means of traditional morphometrics for size and geometric morphometrics for shape. Despite close geographical distance and probable high genetic flow between the populations, statistically significant differences have been found both for size and shape. In fact, one population shows a larger lower pharyngeal element that has a larger central tooth. Compared to the other population, this population also has medially enlarged lower pharyngeal jaws with a more pronounced convexity of the medial-posterior margin. The results are discussed in the light of a possible more pronounced durophagy of this population.
Resumo:
Gnathodiaphyseal dysplasia (GDD) is a rare autosomal dominant condition characterized by bone fragility, irregular bone mineral density (BMD) and fibro-osseous lesions in the skull and jaw. Mutations in Anoctamin-5 (ANO5) have been identified in some cases. We aimed to identify the causative mutation in a family with features of GDD but no mutation in ANO5, using whole exome capture and massive parallel sequencing (WES). WES of two affected individuals (a mother and son) and the mother's unaffected parents identified a mutation in the C-propeptide cleavage site of COL1A1. Similar mutations have been reported in individuals with osteogenesis imperfecta (OI) and paradoxically increased BMD. C-propeptide cleavage site mutations in COL1A1 may not only cause 'high bone mass OI', but also the clinical features of GDD, specifically irregular sclerotic BMD and fibro-osseous lesions in the skull and jaw. GDD patients negative for ANO5 mutations should be assessed for mutations in type I collagen C-propeptide cleavage sites.
Resumo:
An apparatus is described that facilitates the determination of incorporation levels of isotope labelled, gaseous precursors into volatile insect-derived metabolites. Atmospheres of varying gas compositions can be generated by evacuation of a working chamber followed by admission of the required levels of component gases, using a precision, digitised pressure read-out system. Insects such as fruit-flies are located initially in a small introduction chamber, from which migration can occur downwards into the working chamber. The level of incorporation of labelled precursors is continuously assayed by the Solid Phase Micro Extraction (SPME) technique and GC-MS analyses. Experiments with both Bactrocera species (fruit-flies) and a parasitoid wasp, Megarhyssa nortoni nortoni (Cresson) and oxygen-18 labelled dioxygen illustrate the utility of this system. The isotope effects of oxygen-18 on the carbon-13 NMR spectra of 1,7- dioxaspiro[5,5]undecane are also described.
Resumo:
The authors report the design and construction of a very simple vibrating reed apparatus with automatic frequency locking capability where the resonance frequency and the internal friction can be recorded continuously as a function of temperature. The apparatus is particularly suitable for studies down to liquid helium temperatures or below.
Resumo:
A circuit capable of producing bipolar square pulses of voltages up to +or-400 V, employing an integrated circuit timer and two mercury wetted relays is described. The frequency of the pulses can be varied from a cycle min-1 to 2 kHz. A variable temperature sample chamber and the temperature control and measurement circuits are also described. The performance of the circuit is evaluated using samples of TGS and NaNO2.
Resumo:
Purpose: This paper reviews the apparatus used for deformation of bone fracture fixation plates during orthopaedic surgeries including surgical irons, pliers and bending press tools. This paper extends the review to various machineries in non-medical industries and adopts their suitability to clinics-related applications and also covers the evolution of orthopaedic bone plates. This review confirms that none of the studied machineries can be implemented for the deformation of bone fracture fixation plates during orthopaedic surgeries. In addition, this paper also presents the novel apparatus that are designed from scratch for this specific purpose. Several conceptual designs have been proposed and evaluated recently. It has been found that Computer Numerical Control (CNC) systems are not the golden solution to this problem and one needs to attempt to design the robotic arm system. A new design of robotic arm that can be used for facilitating orthopaedic surgeries is being completed.
Resumo:
The endoplasmic reticulum (ER) and the Golgi apparatus are organelles that produce, modify and transport proteins and lipids and regulate Ca2+ environment within cells. Structurally they are composed of sheets and tubules. Sheets may take various forms: intact, fenestrated, single or stacked. The ER, including the nuclear envelope, is a single continuous network, while the Golgi shows only some level of connectivity. It is often unclear, how different morphologies correspond to particular functions. Previous studies indicate that the structures of the ER and Golgi are dynamic and regulated by fusion and fission events, cytoskeleton, rate of protein synthesis and secretion, and specific structural proteins. For example, many structural proteins shaping tubular ER have been identified, but sheet formation is much more unclear. In this study, we used light and electron microscopy to study morphological changes of the ER and Golgi in mammalian cells. The proportion, type, location and dynamics of ER sheets and tubules were found to vary in a cell type or cell cycle stage dependent manner. During interphase, ER and Golgi structures were demonstrated to be regulated by p37, a cofactor of the fusion factor p97, and microtubules, which also affected the localization of the organelles. Like previously shown for the Golgi, the ER displayed a tendency for fenestration and tubulation during mitosis. However, this shape change did not result in ER fragmentation as happens to Golgi, but a continuous network was retained. The activity of p97/p37 was found to be important for the reassembly of both organelles after mitosis. In EM images, ER sheet membranes appear rough, since they contain attached ribosomes, whereas tubular membranes appear smooth. Our studies revealed that structural changes of the ER towards fenestrated and tubular direction correlate with loss of ER-bound ribosomes and vice versa. High and low curvature ER membranes have a low and high density of ribosomes, respectively. To conclude, both ER and Golgi architecture depend on fusion activity of p97/p37. ER morphogenesis, particularly of the sheet shape, is intimately linked to the density of membrane bound ribosomes.
Resumo:
A simple apparatus to measure the absolute thermoelectric power of solids in the temperature range 4·2–300K is described. The cryostat and the associated instrumentation is simple to operate. Representative data of measurements on metallic wire and pressed pellets are given. An accuracy of better than 10% in absolute thermopower can be obtained in this apparatus.
Resumo:
For resonant column tests conducted in the flexure mode of excitation, a new methodology has been proposed to find the elastic modulus and associated axial strain of a cylindrical sample. The proposed method is an improvement over the existing one, and it does not require the assumption of either the mode shape or zero bending moment condition at the top of the sample. A stepwise procedure is given to perform the necessary calculations. From a number of resonant column experiments on aluminum bars and dry sand samples, it has been observed that the present method as compared with the one available in literature provides approximately (i) 5.9%-7.3% higher values of the elastic modulus and (ii) 6.5%-7.3% higher values of the associated axial strains.
Resumo:
An apparatus in the direct shear mode has been developed to conduct soil-soil and soil-solid material interface tests in the undrained condition. Evaluation of the apparatus showed that all the requirements for simulating the undrained condition of shear are satisfied. The interface test results show that the adhesion factor a increases with the surface roughness of the solid material. In the case of the normally consolidated state, alpha is practically independent of the undrained shear strength of the clay for a given surface. For the overconsolidated state, alpha depends on the undrained shear strength and the overconsolidation ratio for smooth surfaces but for rough surfaces; alpha is independent of both undrained shear strength and overconsolidation ratio.
Resumo:
Before installation, a voltage source converter is usually subjected to heat-run test to verify its thermal design and performance under load. For heat-run test, the converter needs to be operated at rated voltage and rated current for a substantial length of time. Hence, such tests consume huge amount of energy in case of high-power converters. Also, the capacities of the source and loads available in the research and development (R&D) centre or the production facility could be inadequate to conduct such tests. This paper proposes a method to conduct heat-run tests on high-power, pulse width modulated (PWM) converters with low energy consumption. The experimental set-up consists of the converter under test and another converter (of similar or higher rating), both connected in parallel on the ac side and open on the dc side. Vector-control or synchronous reference frame control is employed to control the converters such that one draws certain amount of reactive power and the other supplies the same; only the system losses are drawn from the mains. The performance of the controller is validated through simulation and experiments. Experimental results, pertaining to heat-run tests on a high-power PWM converter, are presented at power levels of 25 kVA to 150 kVA.