575 resultados para Isometric Dynamometry
Resumo:
Objective: The aim of the present study was to investigate the between-days reliability of electromyographic (EMG) measurement of 6 bilateral trunk muscles and also the torque output in 3 planes during isometric right and left axial rotation at different exertion levels. Methods: Ten healthy subjects performed isometric right and left axial rotation at 100, 70, 50 and 30% maximum voluntary contractions in two testing sessions at least 7 days apart. EMG amplitude and frequency analyses of the recorded surface EMG signals were performed for rectus abdominis, external oblique, internal oblique, latissimus dorsi, iliocostalis lumborum and multifidus bilaterally. The primary torque in the transverse plane and the coupling torques in sagittal and coronal planes were measured. Results: For both EMG amplitude and frequency values, good (intraclass correlation coefficient, ICC = 0.75-0.89) to excellent (ICC greater than or equal to 0.90) reliability was found in the 6 trunk muscles at different exertion levels during axial rotation. The reliability of both maximal isometric axial rotation torque and coupling torques in sagittal and coronal planes were found to be excellent (ICC greater than or equal to 0.93). Conclusions: Good to excellent reliability of EMG measures of trunk muscles and torque measurements during isometric axial rotation was demonstrated. This provides further confidence of using EMG and triaxial torque assessment as outcome measures in rehabilitation and in the evaluation of the human performance in the work place. (C) 2003 International Federation of Clinical Neurophysiology. Published by Elsevier Ireland Ltd. All rights reserved.
Resumo:
Participation in intensive sports activities leads to muscular specializations that may generate alterations in involved articular forces and cause static (posture) and dynamic changes (alterations of articular stability, coordination, etc.). Prevention of injury requires specific functional muscular evaluation in all athletes and for any kind of sport. OBJECTIVE: To dynamically evaluate, through isokinetic tests, the peak torque, total work, and average power of the knee flexor and extensor muscles of jumper and runner athletes and compare them to those of a non-athletic population, evaluating dominance and balance between agonistic and antagonistic muscle groups. RESULTS: In the non-athlete group, we noted a higher asymmetry between the dominant and nondominant members. The jumpers had the highest values of the evaluated parameters of all groups, whereas parameters for the runners were intermediate between non-athletes and jumpers.
Resumo:
"Vegeu el resum a l'inici del document del fitxer adjunt."
Resumo:
This study investigated the influence of two warm-up protocols on neural and contractile parameters of knee extensors. A series of neuromuscular tests including voluntary and electrically evoked contractions were performed before and after running- (R (WU); slow running, athletic drills, and sprints) and strength-based (S (WU); bilateral 90 degrees back squats, Olympic lifting movements and reactivity exercises) warm ups (duration ~40 min) in ten-trained subjects. The estimated overall mechanical work was comparable between protocols. Maximal voluntary contraction torque (+15.6%; P < 0.01 and +10.9%; P < 0.05) and muscle activation (+10.9 and +12.9%; P < 0.05) increased to the same extent after R (WU) and S (WU), respectively. Both protocols caused a significant shortening of time to contract (-12.8 and -11.8% after R (WU) and S (WU); P < 0.05), while the other twitch parameters did not change significantly. Running- and strength-based warm ups induce similar increase in knee extensors force-generating capacity by improving the muscle activation. Both protocols have similar effects on M-wave and isometric twitch characteristics.
Resumo:
Soil penetration resistance (PR) and the tensile strength of aggregates (TS) are commonly used to characterize the physical and structural conditions of agricultural soils. This study aimed to assess the functionality of a dynamometry apparatus by linear speed and position control automation of its mobile base to measure PR and TS. The proposed equipment was used for PR measurement in undisturbed samples of a clayey "Nitossolo Vermelho eutroférrico" (Kandiudalfic Eutrudox) under rubber trees sampled in two positions (within and between rows). These samples were also used to measure the volumetric soil water content and bulk density, and determine the soil resistance to penetration curve (SRPC). The TS was measured in a sandy loam "Latossolo Vermelho distrófico" (LVd) - Typic Haplustox - and in a very clayey "Nitossolo Vermelho distroférrico" (NVdf) - Typic Paleudalf - under different uses: LVd under "annual crops" and "native forest", NVdf under "annual crops" and "eucalyptus plantation" (> 30 years old). To measure TS, different strain rates were applied using two dynamometry testing devices: a reference machine (0.03 mm s-1), which has been widely used in other studies, and the proposed equipment (1.55 mm s-1). The determination coefficient values of the SRPC were high (R² > 0.9), regardless of the sampling position. Mean TS values in LVd and NVdf obtained with the proposed equipment did not differ (p > 0.05) from those of the reference testing apparatus, regardless of land use and soil type. Results indicate that PR and TS can be measured faster and accurately by the proposed procedure.
Resumo:
This study examined the electromyographic, cerebral and muscle hemodynamic responses during intermittent isometric contractions of biceps brachii at 20, 40, and 60% of maximal voluntary contraction (MVC). Eleven volunteers completed 2 min of intermittent isometric contractions (12/min) at an elbow angle of 90° interspersed with 3 min rest between intensities in systematic order. Surface electromyography (EMG) was recorded from the right biceps brachii and near infrared spectroscopy (NIRS) was used to simultaneously measure left prefrontal and right biceps brachii oxyhemoglobin (HbO2), deoxyhemoglobin (HHb), and total hemoglobin (Hbtot). Transcranial Doppler ultrasound was used to measure middle cerebral artery velocity (MCAv) bilaterally. Finger photoplethysmography was used to record beat-to-beat blood pressure and heart rate. EMG increased with force output from 20 to 60% MVC (P < 0.05). Cerebral HbO2 and Hbtot increased while HHb decreased during contractions with differences observed between 60% vs. 40% and 20% MVC (P < 0.05). Muscle HbO2 decreased while HHb increased during contractions with differences being observed among intensities (P < 0.05). Muscle Hbtot increased from rest at 20% MVC (P < 0.05), while no further change was observed at 40 and 60% MVC (P > 0.05). MCAv increased from rest to exercise but was not different among intensities (P > 0.05). Force output correlated with the root mean square EMG and changes in muscle HbO2 (P < 0.05), but not changes in cerebral HbO2 (P > 0.05) at all three intensities. Force output declined by 8% from the 1st to the 24th contraction only at 60% MVC and was accompanied by systematic increases in RMS, cerebral HbO2 and Hbtot with a leveling off in muscle HbO2 and Hbtot. These changes were independent of alterations in mean arterial pressure. Since cerebral blood flow and oxygenation were elevated at 60% MVC, we attribute the development of fatigue to reduced muscle oxygen availability rather than impaired central neuronal activation.
Resumo:
INTRODUCTION: We examined the power spectral changes of the compound muscle action potential (M wave) evoked during isometric contractions of increasing strength. METHODS: Surface electromyography (sEMG) of the vastus lateralis and medialis was recorded from 20 volunteers who performed 4-s step-wise isometric contractions of different intensities. A maximal M wave was elicited by a single stimulus to the femoral nerve and superimposed on the voluntary contractions. The spectral characteristics (Fmean and Fmedian) of sEMG and M-wave signals were calculated. RESULTS: M-wave spectral indicators increased systematically with contraction intensity up to 60% MVC and then leveled off at higher forces. Over the 10-60% MVC range, the increase in spectral indicators was 3 times higher for M waves (36%) than for sEMG (12%). CONCLUSIONS: The consistent increase in M-wave spectral characteristics with force is due to the fact that the number of motor units recruited by the superimposed supramaximal stimulus is approximately stable.
Resumo:
Endothelial cell release of nitric oxide (NO) is a defining characteristic of nondiseased arteries, and abnormal endothelial NO release is both a marker of early atherosclerosis and a predictor of its progression and future events. Healthy coronaries respond to endothelial-dependent stressors with vasodilatation and increased coronary blood flow (CBF), but those with endothelial dysfunction respond with paradoxical vasoconstriction and reduced CBF. Recently, coronary MRI and isometric handgrip exercise (IHE) were reported to noninvasively quantify coronary endothelial function (CEF). However, it is not known whether the coronary response to IHE is actually mediated by NO and/or whether it is reproducible over weeks. To determine the contribution of NO, we studied the coronary response to IHE before and during infusion of N(G)-monomethyl-l-arginine (l-NMMA, 0.3 mg·kg(-1)·min(-1)), a NO-synthase inhibitor, in healthy volunteers. For reproducibility, we performed two MRI-IHE studies ∼8 wk apart in healthy subjects and patients with coronary artery disease (CAD). Changes from rest to IHE in coronary cross-sectional area (%CSA) and diastolic CBF (%CBF) were quantified. l-NMMA completely blocked normal coronary vasodilation during IHE [%CSA, 12.9 ± 2.5 (mean ± SE, placebo) vs. -0.3 ± 1.6% (l-NMMA); P < 0.001] and significantly blunted the increase in flow [%CBF, 47.7 ± 6.4 (placebo) vs. 10.6 ± 4.6% (l-NMMA); P < 0.001]. MRI-IHE measures obtained weeks apart strongly correlated for CSA (P < 0.0001) and CBF (P < 0.01). In conclusion, the normal human coronary vasoactive response to IHE is primarily mediated by NO. This noninvasive, reproducible MRI-IHE exam of NO-mediated CEF promises to be useful for studying CAD pathogenesis in low-risk populations and for evaluating translational strategies designed to alter CAD in patients.
Resumo:
Concentration-response curves of isometric tension studies on isolated blood vessels are obtained traditionally. Although parameters such as Imax, EC50 and pA2 may be readily calculated, this method does not provide information on the temporal profile of the responses or the actual nature of the reaction curves. Computerized data acquisition systems can be used to obtain average data that represent a new source of otherwise inaccessible information, since early and late responses may be observed separately in detail
Resumo:
The purpose of the present study was to examine the relationship between the electromyographic (EMG) activity and heart rate (HR) responses induced by isometric exercise performed by knee extension (KE) and flexion (KF) in men. Fifteen healthy male subjects, 21 ± 1.3 years (mean ± SD), were submitted to KE and KF isometric exercise tests at 100% of maximal voluntary contraction (MVC). The exercises were performed with one leg (right or left) and with two legs simultaneously, for 10 s in the sitting position with the hip and knee flexed at 90o. EMG activity (root mean square values) and HR (beats/min) were recorded simultaneously both at rest and throughout the sustained contraction. The HR responses to isometric exercise in KE and KF were similar when performed with one and two legs. However, the HR increase was always significantly higher in KE than KF (P<0.05), whereas the EMG activity was higher in KE than in KF (P<0.05), regardless of the muscle mass (one or two legs) involved in the effort. The correlation coefficients between HR response and the EMG activity during KE (r = 0.33, P>0.05) and KF (r = 0.15, P>0.05) contractions were not significant. These results suggest that the predominant mechanism responsible for the larger increase in HR response to KE as compared to KF in our study could be dependent on qualitative and quantitative differences in the fiber type composition found in each muscle group. This mechanism seems to demand a higher activation of motor units with a corresponding increase in central command to the cardiovascular centers that modulate HR control.
Resumo:
An isometric view of the planned Decew Residence.
Resumo:
The main objective of this research was to examine the relationship between surface electromyographic (SEMG) spike activity and force. The secondary objective was to determine to what extent subcutaneous tissue impacts the high frequency component of the signal, as well as, examining the relationship between measures of SEMG spike shape and their traditional time and frequency analogues. A total of96 participants (46 males and 50 females) ranging in age (18-35 years), generated three 5-second isometric step contractions at each force level of 40, 60, 80, and 100 percent of maximal voluntary contraction (MVC). The presentation of the contractions was balanced across subjects. The right arm of the subject was positioned in the sagittal plane, with the shoulder and elbow flexed to 90 degrees. The elbow rested on a support in a neutral position (mid pronation/mid supination) and placed within a wrist cuff, fastened below the styloid process. The wrist cuff was attached to a load cell (JR3 Inc., Woodland, CA) recording the force produced. Biceps brachii activity was monitored with a pair of Ag/AgCI recording electrodes (Grass F-E9, Astro-Med Inc., West Warwick, RI) placed in a bipolar configuration, with an interelectrode distance (lED) of 2cm distal to the motor point. Data analysis was performed on a I second window of data in the middle of the 5-second contraction. The results indicated that all spike shape measures exhibited significant (p < 0.01) differences as force increase~ from 40 to 100% MVC. The spike shape measures suggest that increased motor unit (MU) recruitment was responsible for increasing force up to 80% MVC. The results suggested that further increases in force relied on MU III synchronization. The results also revealed that the subcutaneous tissue (skin fold thickness) had no relationship (r = 0.02; P > 0.05) with the mean number of peaks per spike (MNPPS), which was the high frequency component of the signal. Mean spike amplitude (MSA) and mean spike frequency (MSF) were highly correlated with their traditional measures root mean square (RMS) and mean power frequency (MPF), respectively (r = 0.99; r = 0.97; P < 0.01).
Resumo:
This study evaluated sex-related differences in the tibialis anterior (TA) surface electromyography (EMG) to force relationship. One-hundred participants (50 males and 50 females) performed three isometric contractions at 20, 40, 60, 80, and 100% of maximal voluntary contraction (MVC) in an apparatus designed to isolate the action of the dorsiflexors. The surface EMG signal was amplified (lOOOx), band-pass filtered (10-500Hz), and sampled at 2048 Hz. The load cell signal was low-passed filtered at 100 Hz and sampled at the same rate. Males were stronger than females {P <0.05). However, there was no significant difference in root-mean-square (RMS) values between sexes {P <0.05). Both sexes exhibited a quadratic increase in RMS across force levels (P <0.05). The mean power frequency (MNF) for males was greater than for females {P <0.05). Males and females exhibited a linear increase in both frequency measures up to 80% of MVC (P <0.05). Between 80 and 100% MVC, the frequency values for the females plateaued while males showed a decrease {P <0.05). The magnitude of the difference in MNF between males and females was consistent with sex-specific TA physiology. In general, the pattern of means for RMS and MNF between males and females revealed no sex-related differences in the surface EMG/force relationship. We therefore conclude that there are no sex-related differences in the gradation of muscle force.
Resumo:
Twenty-six sedentary, college-aged females were matched and randomly assigned to one of two groups. The massed group (n=13) completed 15 maximal isometric elbow flexion strength trials in one session, while the distributed group (n=13) performed five such contractions on three successive days. After a two-week and three month rest interval, both groups returned to perfonn another five maximal isometric elbow flexion strength trials to assess retention of any potential strength gains. Elbow flexion torque and surface electromyography (SEMG) of the biceps and triceps were monitored concurrently. There was a significant (P < 0.05) increase in strength in both groups from block one (first five contractions) to block four (first retest) and from block one to block five (second retest). Both groups exhibited a similar linear increasing (P < 0.05) trend in biceps root-mean-square (RMS) SEMG amplitude. A significant (P < 0.05) decrease in triceps RMS SEMG amplitude was found between block one and block four for the distributed group. However, a significant (P < 0.05) increase was then found between block one and five for the massed group, and between blocks four and five for distributed group. These results suggest that there is flexibility in resistive exercise schedules. An increase in neural drive to the agonist muscle continued throughout testing. This was accompanied by a reduction in antagonist co activation that was a short-tenn (two weeks) training effect, dissipated over the longer rest interval (three months).
Resumo:
To date there is no documented procedure to extrapolate findings of an isometric nature to a whole body performance setting. The purpose of this study was to quantify the reliability of perceived exertion to control neuromuscular output during an isometric contraction. 21 varsity athletes completed a maximal voluntary contraction and a 2 min constant force contraction at both the start and end of the study. Between pre and post testing all participants completed a 2 min constant perceived exertion contraction once a day for 4 days. Intra-class correlation coefficient (R=O.949) and standard error of measurement (SEM=5.12 Nm) concluded that the isometric contraction was reliable. Limits of agreement demonstrated only moderate initial reliability, yet with smaller limits towards the end of 4 training sessions. In conclusion, athlete's na"ive to a constant effort isometric contraction will produce reliable and acceptably stable results after 1 familiarization sessions has been completed.