955 resultados para Isometric Axial Rotation
Resumo:
The use of dual growing rods is a fusionless surgical approach to the treatment of early onset scoliosis (EOS) which aims to harness potential growth in order to correct spinal deformity. This study compared through in-vitro experiments the biomechanical response of two different rod designs under axial rotation loading. The study showed that a new design of telescoping growing rod preserved the rotational flexibility of the spine in comparison with rigid rods indicating them to be a more physiological way to improve the spinal deformity.
Resumo:
INTRODUCTION Managing spinal deformities in young children is challenging, particularly early onset scoliosis (EOS). Surgical intervention is often required if EOS has been unresponsive to conservative treatment particularly with rapidly progressive curves. An emerging treatment option for EOS is fusionless scoliosis surgery. Similar to bracing, this surgical option potentially harnesses growth, motion and function of the spine along with correcting spinal deformity. Dual growing rods are one such fusionless treatment, which aims to modulate growth of the vertebrae. The aim of this study was to ascertain the extent to which semiconstrained growing rods (Medtronic, Sofamor, Danek, Memphis, TN) with a telescopic sleeve component, reduce rotational constraint on the spine compared with standard "constrained / rigid" rods and hence potentially provide a more physiological mechanical environment for the growing spine. METHODS Six 40-60kg English Large White porcine spines served as a model for the paediatric human spine. Each spine was dissected into a 7 level thoracolumbar multi-segment unit (MSU), removing all non-ligamentous soft tissues and leaving 3cm of ribs either side. Pure nondestructive axial rotation moments of ±4Nm at a constant rotation rate of 8deg.s-1 were applied to the mounted MSU spines using a biaxial Instron testing machine. Displacement of each vertebral level was captured using a 3D motion tracking system (Optotrak 3020, Northern Digital Inc, Waterloo, ON). Each spine was tested in an un-instrumented state first and then with appropriately sized semi-constrained growing rods and rigid rods in alternating sequence. The rods were secured by multi-axial pedicle screws (Medtronic CD Horizon) at levels 2 and 6 of the construct. The range of motion (ROM), neutral zone (NZ) size and stiffness (Nm.deg-1) were calculated from the Instron load-displacement data and intervertebral ROM was calculated through a MATLAB algorithm from Optotrak data. RESULTS Irrespective of the order of testing, rigid rods significantly reduced the total ROM compared with semi-constrained rods (p<0.05) with in a significantly stiffer spine for both left and right axial rotation (p<0.05). Analysing the intervertebral motion within the instrumented levels 2-6, rigid rods showed reduced ROM compared with semi-constrained growing rods and compared with un-instrumented motion segments. CONCLUSION Semi-constrained growing rods maintain similar stiffness in axial rotation to un-instrumented spines, while dual rigid rods significantly reduce axial rotation. Clinically the effect of semi-constrained growing rods as observed in this study is that they would be expected to allow growth via the telescopic rod components while maintaining the axial flexibility of the spine, which may reduce occurrence of the crankshaft phenomenon.
Resumo:
Introduction The importance of in vitro biomechanical testing in today’s understanding of spinal pathology and treatment modalities cannot be stressed enough. Different studies have used differing levels of dissection of their spinal segments for their testing protocols[1, 2]. The aim of this study was to assess the impact of removing the costovertebral joints and partial resection of the spinous process sequentially, on the stiffness of the immature thoracic bovine spinal segment. Materials and Methods Thoracic spines from 6-8 week old calves were used. Each spine was dissected and divided into motion segments with 5cm of attached rib on each side and full spinous processes including levels T4-T11 (n=28). They were potted in polymethylemethacrylate. An Instron Biaxial materials testing machine with a custom made jig was used for testing. The segments were tested in flexion/extension, lateral bending and axial rotation at 37⁰C and 100% humidity, using moment control to a maximum 1.75 Nm with a loading rate of 0.3 Nm per second. They were first tested intact for ten load cycles with data collected from the tenth cycle. Progressive dissection was performed by removing first the attached ribs, followed by the spinous process at its base. Biomechanical testing was carried out after each level of dissection using the same protocol. Statistical analysis of the data was performed using repeated measures ANOVA. Results In combined flexion/extension there was a significant reduction in stiffness of 16% (p=0.002). This was mainly after resection of the ribs (14%, p=0.024) and mainly occurred in flexion where stiffness reduced by 22% (p=0.021). In extension, stiffness dropped by 13% (p=0.133). However there was no further significant change in stiffness on resection of the spinous process (<1%) (p=1.00). In lateral bending there was a significant decrease in stiffness of 13% (p<0.001). This comprised a drop of 11% on resection of the ribs (p=0.009) and a further 8% on resection of the spinous process (p=0.014). There was no difference between left and right bending. In axial rotation there was no significant change in stiffness after each stage of dissection (p=0.253). There was no difference between left and right rotation. Conclusion The costovertebral joints play a significant role in providing stability to the bovine thoracic spine in both flexion/extension and lateral bending, whereas the spinous processes play a minor role. Both elements have little effect on axial rotation stability.
Resumo:
Introduction Intervertebral stapling is a leading method of fusionless scoliosis treatment which attempts to control growth by applying pressure to the convex side of a scoliotic curve in accordance with the Hueter-Volkmann principle. In addition to that, staples have the potential to damage surrounding bone during insertion and subsequent loading. The aim of this study was to assess the extent of bony structural damage including epiphyseal injury as a result of intervertebral stapling using an in vitro bovine model. Materials and Methods Thoracic spines from 6-8 week old calves were dissected and divided into motion segments including levels T4-T11 (n=14). Each segment was potted in polymethylemethacrylate. An Instron Biaxial materials testing machine with a custom made jig was used for testing. The segments were tested in flexion/extension, lateral bending and axial rotation at 37⁰C and 100% humidity, using moment control to a maximum 1.75 Nm with a loading rate of 0.3 Nm per second for 10 cycles. The segments were initially tested uninstrumented with data collected from the tenth load cycle. Next an anterolateral 4-prong Shape Memory Alloy (SMA) staple (Medtronic Sofamor Danek, USA) was inserted into each segment. Biomechanical testing was repeated as before. The staples were cut in half with a diamond saw and carefully removed. Micro-CT scans were performed and sagittal, transverse and coronal reformatted images were produced using ImageJ (NIH, USA).The specimens were divided into 3 grades (0, 1 and 2) according to the number of epiphyses damaged by the staple prongs. Results: There were 9 (65%) segments with grade 1 staple insertions and 5 (35%) segments with grade 2 insertions. There were no grade 0 staples. Grade 2 spines had a higher stiffness level than grade 1 spines, in all axes of movement, by 28% (p=0.004). This was most noted in flexion/extension with an increase of 49% (p=0.042), followed by non-significant change in lateral bending 19% (p=0.129) and axial rotation 8% (p=0.456) stiffness. The cross sectional area of bone destruction from the prongs was only 0.4% larger in the grade 2 group compared to the grade 1 group (p=0.961). Conclusion Intervertebral staples cause epiphyseal damage. There is a difference in stiffness between grade 1 and grade 2 staple insertion segments in flexion/extension only. There is no difference in the cross section of bone destruction as a result of prong insertion and segment motion.
Resumo:
Introduction There is growing interest in the biomechanics of ‘fusionless’ implant constructs used for deformity correction in the thoracic spine. Intervertebral stapling is a leading method of fusionless corrective surgery. Although used for a number of years, there is limited evidence as to the effect these staples have on the stiffness of the functional spinal unit. Materials and Methods Thoracic spines from 6-8 week old calves were dissected and divided into motion segments including levels T4-T11 (n=14). Each segment was potted in polymethylemethacrylate. An Instron Biaxial materials testing machine with a custom made jig was used for testing. The segments were tested in flexion/extension, lateral bending and axial rotation at 37⁰C and 100% humidity, using moment control to a maximum 1.75 Nm with a loading rate of 0.3 Nm per second. This torque was found sufficient to achieve physiologically representative ranges of movement. The segments were initially tested uninstrumented with data collected from the tenth load cycle. Next a left anterolateral Shape Memory Alloy (SMA) staple was inserted (Medtronic Sofamor Danek, USA). Biomechanical testing was repeated as before with data collected from the tenth load cycle. Results In flexion/extension there was an insignificant drop in stiffness of 3% (p=0.478). In lateral bending there was a significant drop in stiffness of 21% (p<0.001). This was mainly in lateral bending away from the staple, where the stiffness reduced by 30% (p<0.001). This was in contrast to lateral bending towards the staple where it dropped by 12% which was still statistically significant (p=0.036). In axial rotation there was an overall near significant drop in stiffness of 11% (p=0.076). However, this was more towards the side of the staple measuring a decrease of 14% as opposed to 8% away from the staple. In both cases it was a statistically insignificant drop (p=0.134 and p=0.352 respectively). Conclusion Insertion of intervertebral SMA staples results in a significant reduction in motion segment stiffness in lateral bending especially in the direction away from the staple. The staple had less effect on axial rotation stiffness and minimal effect on flexion/extension stiffness.
Resumo:
INTRODUCTION Managing spinal deformities in young children is challenging, particularly early-onset scoliosis (EOS). Any progressive spinal deformity particularly in early life presents significant health risks for the child and a challenge for the treating surgeon. Surgical intervention is often required if EOS has been unresponsive to conservative treatment particularly with rapidly progressive curves. An emerging treatment option particularly for EOS is fusionless scoliosis surgery. Similar to bracing this surgical option potentially harnesses growth, motion and function of the spine along with correcting spinal deformity. Dual growing rods is one such fusionless treatment, which aims to modulate growth of the vertebrae. The aim of this study was to ascertain the extent to which semi-constrained growing rods (Medtronic, Memphis, TN) with a telescopic sleeve component, reduce rotational constraint on the spine compared with standard rigid rods and hence potentially provide a more physiological mechanical environment for the growing spine. METHODS Six 40-60kg English Large White porcine spines served as a model for the paediatric human spine. Each spine was dissected into 7 level thoracolumbar multi-segment unit (MSU) spines, removing all non-ligamentous soft tissues. Appropriately sized semi-constrained growing rods and rigid rods were secured by multi-axial screws (Medtronic) prior to testing in alternating sequences for each spine. Pure nondestructive moments of +/4Nm at a constant rotation rate of 8deg/s was applied to the mounted MSU spines. Displacement of each level was captured using an Optotrak (Northern Digital Inc, Waterloo, ON). The range of motion (ROM), neutral zone (NZ) size and stiffness (Nm/deg) were calculated from the Instron load-displacement data and intervertebral ROM was calculated through a MATLAB algorithm from Optotrak data. RESULTS Irrespective of sequence order rigid rods significantly reduced the total ROM (deg) than compared to semi-constrained rods (p<0.05) and resulted in a significantly stiffer (Nm/deg) spine for both left and right axial rotation testing (p<0.05). Analysing the intervertebral motion within the instrumented levels, rigid rods showed reduced ROM (Deg) than compared to semi-constrained growing rods and the un-instrumented (UN-IN) test sequences. CONCLUSION The semi-constrained growing rods maintained rotation similar to UN-IN spines while the rigid rods showed significantly reduced axial rotation across all instrumented levels. Clinically the effect of semi-constrained growing rods evaluated in this study is that they will allow growth via the telescopic rod components while maintaining the axial rotation ability of the spine, which may also reduce the occurrence of the crankshaft phenomenon.
Resumo:
Finite element (FE) model studies have made important contributions to our understanding of functional biomechanics of the lumbar spine. However, if a model is used to answer clinical and biomechanical questions over a certain population, their inherently large inter-subject variability has to be considered. Current FE model studies, however, generally account only for a single distinct spinal geometry with one set of material properties. This raises questions concerning their predictive power, their range of results and on their agreement with in vitro and in vivo values. Eight well-established FE models of the lumbar spine (L1-5) of different research centres around the globe were subjected to pure and combined loading modes and compared to in vitro and in vivo measurements for intervertebral rotations, disc pressures and facet joint forces. Under pure moment loading, the predicted L1-5 rotations of almost all models fell within the reported in vitro ranges, and their median values differed on average by only 2° for flexion-extension, 1° for lateral bending and 5° for axial rotation. Predicted median facet joint forces and disc pressures were also in good agreement with published median in vitro values. However, the ranges of predictions were larger and exceeded those reported in vitro, especially for the facet joint forces. For all combined loading modes, except for flexion, predicted median segmental intervertebral rotations and disc pressures were in good agreement with measured in vivo values. In light of high inter-subject variability, the generalization of results of a single model to a population remains a concern. This study demonstrated that the pooled median of individual model results, similar to a probabilistic approach, can be used as an improved predictive tool in order to estimate the response of the lumbar spine.
Resumo:
There is growing interest in the biomechanics of ‘fusionless’ implant constructs used for deformity correction in the thoracic spine, however, there are questions over the comparability of in vitro biomechanical studies from different research groups due to the various methods used for specimen preparation, testing and data collection. The aim of this study was to identify the effect of two key factors on the stiffness of immature bovine thoracic spine motion segments: (i) repeated cyclic loading and (ii) multiple freeze-thaw cycles, to aid in the planning and interpretation of in vitro studies. Two groups of thoracic spine motion segments from 6-8 week old calves were tested in flexion/extension, right/left lateral bending, and right/left axial rotation under moment control. Group (A) were tested with continuous repeated cyclic loading for 500 cycles with data recorded at cycles 3, 5, 10, 25, 50, 100, 200, 300, 400 and 500. Group (B) were tested after each of five freeze-thaw sequences, with data collected from the 10th load cycle in each sequence. Group A: Flexion/extension stiffness reduced significantly over the 500 load cycles (-22%; P=0.001), but there was no significant change between the 5th and 200th load cycles. Lateral bending stiffness decreased significantly (-18%; P=0.009) over the 500 load cycles, but there was no significant change in axial rotation stiffness (P=0.137). Group B: There was no significant difference between mean stiffness over the five freeze-thaw sequences in flexion/extension (P=0.813) and a near significant reduction in mean stiffness in axial rotation (-6%; P=0.07). However, there was a statistically significant increase in stiffness in lateral bending (+30%; P=0.007). Comparison of in vitro testing results for immature thoracic bovine spine segments between studies can be performed with up to 200 load cycles without significant changes in stiffness. However, when testing protocols require greater than 200 cycles, or when repeated freeze-thaw cycles are involved, it is important to account for the effect of cumulative load and freeze-thaw cycles on spine segment stiffness.
Resumo:
Background The use of dual growing rods is a fusionless surgical approach to the treatment of early onset scoliosis (EOS), which aims of harness potential growth in order to correct spinal deformity. The purpose of this study was to compare the in-vitro biomechanical response of two different dual rod designs under axial rotation loading. Methods Six porcine spines were dissected into seven level thoracolumbar multi-segmental units. Each specimen was mounted and tested in a biaxial Instron machine, undergoing nondestructive left/right axial rotation to peak moments of 4Nm at a constant rotation rate of 8deg.s-1. A motion tracking system (Optotrak) measured 3D displacements of individual vertebrae. Each spine was tested in an un-instrumented state first and then with appropriately sized semi-constrained growing rods and ‘rigid’ rods in alternating sequence. Range of motion, neutral zone size and stiffness were calculated from the moment-rotation curves and intervertebral ranges of motion were calculated from Optotrak data. Findings Irrespective of test sequence, rigid rods showed significantly reduction of total rotation across all instrumented levels (with increased stiffness) whilst semi-constrained rods exhibited similar rotation behavior to the un-instrumented (P<0.05). An 11% and 8% increase in stiffness for left and right axial rotation respectively and 15% reduction in total range of motion was recorded with dual rigid rods compared with semi-constrained rods. Interpretation Based on these findings, the semi-constrained growing rods do not increase axial rotation stiffness compared with un-instrumented spines. This is thought to provide a more physiological environment for the growing spine compared to dual rigid rod constructs.
Resumo:
Due to its ability to represent intricate systems with material nonlinearities as well as irregular loading, boundary, geometrical and material domains, the finite element (FE) method has been recognized as an important computational tool in spinal biomechanics. Current FE models generally account for a single distinct spinal geometry with one set of material properties despite inherently large inter-subject variability. The uncertainty and high variability in tissue material properties, geometry, loading and boundary conditions has cast doubt on the reliability of their predictions and comparability with reported in vitro and in vivo values. A multicenter study was undertaken to compare the results of eight well-established models of the lumbar spine that have been developed, validated and applied for many years. Models were subjected to pure and combined loading modes and their predictions were compared to in vitro and in vivo measurements for intervertebral rotations, disc pressures and facet joint forces. Under pure moment loading, the predicted L1-5 rotations of almost all models fell within the reported in vitro ranges; their median values differed on average by only 2° for flexion-extension, 1° for lateral bending and 5° for axial rotation. Predicted median facet joint forces and disc pressures were also in good agreement with previously published median in vitro values. However, the ranges of predictions were larger and exceeded the in vitro ranges, especially for facet joint forces. For all combined loading modes, except for flexion, predicted median segmental intervertebral rotations and disc pressures were in good agreement with in vivo values. The simulations yielded median facet joint forces of 0 N in flexion, 38 N in extension, 14 N in lateral bending and 60 N in axial rotation that could not be validated due to the paucity of in vivo facet joint forces. In light of high inter-subject variability, one must be cautious when generalizing predictions obtained from one deterministic model. This study demonstrates however that the predictive power increases when FE models are combined together. The median of individual numerical results can hence be used as an improved tool in order to estimate the response of the lumbar spine.
Resumo:
Des anomalies dans la morphologie pelvienne, la posture du tronc et le contrôle de l’équilibre de jeunes filles atteintes de scoliose idiopathique de l’adolescence (SIA) ont souvent été l’objet d’études. Rares sont celles ayant distingué ces troubles en fonction de la sévérité de la déformation vertébrale. De plus, aucune n’a évalué à l’intérieur d’une même étude l’orientation et la distorsion pelvienne, l’asymétrie posturale et l’instabilité en position debout de sujets SIA. Une telle étude permettrait de comprendre le développement de la maladie et de mettre en évidence des facteurs de risque aidant au pronostic. L’objectif général de cette thèse est d’identifier des facteurs biomécaniques associés à la croissance osseuse, la posture et l’équilibre distinguant une SIA modérée d’une sévère. Les positions 3D de 14 repères prises sur 46 filles ayant une SIA droite (modérée et sévère) et 28 sujets témoins ont été captées pour quantifier la morphologie pelvienne et la posture. Un maintien en position debout de 64 s sur une plate-forme de force a aussi été enregistré afin d’évaluer leur équilibre. Les paramètres retenus sont les angles d’orientation pelvienne et du tronc; les distances entre la crête iliaque et S1 mesurant la distorsion pelvienne; la moyenne, l’amplitude et la vitesse du centre de pression (COP) en médiolatéral (ML) et antéropostérieur ainsi que la moyenne et l’amplitude du moment libre. Les différences entre les trois groupes (témoin, SIA modérée et SIA sévère) sont testées par des ANOVA et les relations entre l’angle de Cobb et les paramètres pelviens, posturaux ou d’équilibre, par des coefficients de corrélations. De plus, des régressions multiples exprimant l’angle de Cobb sont effectuées avec les paramètres pelviens, posturaux et d’équilibre afin de déterminer la classe de paramètres prédisant le mieux l’angle de Cobb. Aucune ANOVA n’est significative pour l’orientation pelvienne, bien que des différences de géométrie pelvienne soient notées entre les deux groupes de sujets SIA. Les SIA modérées ont un pelvis gauche moins profond que les SIA sévères et les sujets témoins, tandis que les SIA sévères ont un pelvis droit plus large d’environ 1,5 cm que celui des SIA modérées. Un coefficient de corrélation de -0,54 associe une rotation pelvienne droite à l’augmentation de la largeur de la crête iliaque. Au niveau postural, les SIA sévères démontrent des inclinaisons latérales et antérieures du tronc ainsi qu’une rotation axiale du haut du corps plus marquées que les SIA modérées. Les corrélations entre les paramètres posturaux, l’angle de Cobb et la morphologie pelvienne indiquent que l’attitude posturale est associée à la distorsion pelvienne dans tous les plans anatomiques, tandis qu’elle ne l’est que dans les plans sagittal et horizontal à l’angle de Cobb. Les différences retrouvées entre les deux groupes SIA concernant les troubles d’équilibre résultent en une augmentation de l’amplitude et de la vitesse du COPML. Une régression multiple de 0,896 est observée par l’emploi des paramètres pelviens, posturaux et d’équilibre, bien que ceux se rapportant à la distorsion pelvienne soient les mieux corrélés à l’angle de Cobb. Cette thèse permet de distinguer la morphologie pelvienne de sujets SIA sévères des modérées, soulignant la détection d’une anomalie de croissance avant que l’angle de Cobb ne soit élevé. Bien que les indices de croissance pelvienne soient davantage corrélés à ce dernier, c’est en considérant globalement la morphologie pelvienne, la posture et l’équilibre qu’une détermination précise de la sévérité d’une scoliose est réalisée. La mise en évidence de tels facteurs de prédiction de la SIA peut faciliter le pronostic d’une courbure.
Resumo:
La scoliose idiopathique de l’adolescent est une déformation 3D du rachis. La littérature comporte une multitude d’études sur la prédiction de l’évolution et l’identification de facteurs de risque de progression. Pour l’instant les facteurs de risque établis sont l’amplitude de la déformation, la maturité squelettique et le type de courbure. Plusieurs autres champs ont été explorés comme les aspects génétiques, biochimiques, mécaniques, posturaux et topographiques, sans vraiment apporter beaucoup de précision à la prédiction de l’évolution. L’avancement de la technologie permet maintenant de générer des reconstructions 3D du rachis à l’aide des radiographies standard et d’obtenir des mesures de paramètres 3D. L’intégration de ces paramètres 3D dans un modèle prédictif représente une avenue encore inexplorée qui est tout à fait logique dans le contexte de cette déformation 3D du rachis. L’objectif général de cette thèse est de développer un modèle de prédiction de l’angle de Cobb à maturité squelettique à partir de l’information disponible au moment de la première visite, soit l’angle de Cobb initial, le type de courbure, l’âge osseux et des paramètres 3D du rachis. Dans une première étude, un indice d’âge osseux a été développé basé sur l’ossification de l’apophyse iliaque et sur le statut du cartilage triradié. Cet indice comporte 3 stades et le second stade, qui est défini par un cartilage triradié fermé avec maximum 1/3 d’ossification de l’apophyse iliaque, représente le moment pendant lequel la progression de la scoliose idiopathique de l’adolescent est la plus rapide. Une seconde étude rétrospective a permis de mettre en évidence le potentiel des paramètres 3D pour améliorer la prédiction de l’évolution. Il a été démontré qu’à la première visite il existe des différences pour 5 paramètres 3D du rachis entre un groupe de patients qui sera éventuellement opéré et un groupe qui ne progressera pas. Ces paramètres sont : la moyenne da la cunéiformisation 3D des disques apicaux, la rotation intervertébrale à la jonction inférieure de la courbure, la torsion, le ratio hauteur/largeur du corps vertébral de T6 et de la colonne complète. Les deux dernières études sont basées sur une cohorte prospective de 133 patients avec une scoliose idiopathique de l’adolescent suivi dès leur première visite à l’hôpital jusqu’à maturité squelettique. Une première étude a permis de mettre en évidence les différences morphologiques à la première visite entre les patients ayant progresser de plus ou moins de 6°. Des différences ont été mise en évidence pour la cyphose, l’angle de plan de déformation maximal, la rotation ntervertébrale l’apex, la torsion et plusieurs paramètres de «slenderness». Ensuite une seconde étude a permis de développer un modèle prédictif basé sur un modèle linéaire général en incluant l’indice d’âge osseux développé dans la première étude, le type de courbure, l’amplitude de l’angle de Cobb à la première visite, l’angle de déformation du plan maximale, la cunéiformisation 3D des disques T3-T4, T8-T9, T11-T12 et la somme des cunéiformisation 3D de tous les disques thoraciques et lombaires. Le coefficient de détermination multiple pour cette modélisation est de 0.715. Le modèle prédictif développé renforce l’importance de considérer la scoliose idiopathique dans les trois dimensions et il permettra d’optimiser la prédiction de l’évolution au moment de la première visite.
Resumo:
L'épaule est souvent affectée par des troubles musculo-squelettiques. Toutefois, leur évaluation est limitée à des mesures qualitatives qui nuisent à la spécificité et justesse du diagnostic. L'analyse de mouvement tridimensionnel pourrait complémenter le traitement conventionnel à l'aide de mesures quantitatives fonctionnelles. L'interaction entre les articulations de l'épaule est estimée par le rythme scapulo-huméral, mais la variabilité prononcée qu'il affiche nuit à son utilisation clinique. Ainsi, l'objectif général de cette thèse était de réduire la variabilité de la mesure du rythme scapulo-huméral. L'effet de la méthode de calcul du rythme scapulo-huméral et des conditions d'exécution du mouvement (rotation axiale du bras, charge, vitesse, activité musculaire) ont été testées. La cinématique des articulations de l'épaule a été calculé par chaîne cinématique et filtre de Kalman étendu sur des sujets sains avec un système optoélectronique. La méthode usuelle de calcul du rythme scapulo-huméral extrait les angles d'élévation gléno-humérale et de rotation latérale scapulo-thoracique. Puisque ces angles ne sont pas co-planaires au thorax, leur somme ne correspond pas à l'angle d'élévation du bras. Une nouvelle approche de contribution articulaire incluant toutes les rotations de chaque articulation est proposée et comparée à la méthode usuelle. La méthode usuelle surestimait systématiquement la contribution gléno-humérale par rapport à la méthode proposée. Ce nouveau calcul du rythme scapulo-huméral permet une évaluation fonctionnelle dynamique de l'épaule et réduit la variabilité inter-sujets. La comparaison d'exercices de réadaptation du supra-épineux contrastant la rotation axiale du bras a été réalisée, ainsi que l'effet d'ajouter une charge externe. L'exercice «full-can» augmentait le rythme scapulo-huméral et la contribution gléno-humérale ce qui concorde avec la fonction du supra-épineux. Au contraire, l'exercice «empty-can» augmentait la contribution scapulo-thoracique ce qui est associé à une compensation pour éviter la contribution gléno-humérale. L'utilisation de charge externe lors de la réadaptation du supra-épineux semble justifiée par un rythme scapulo-huméral similaire et une élévation gléno-humérale supérieure. Le mouvement de l'épaule est souvent mesuré ou évalué en condition statique ou dynamique et passive ou active. Cependant, l'effet de ces conditions sur la coordination articulaire demeure incertain. La comparaison des ces conditions révélait des différences significatives qui montrent l'importance de considérer les conditions de mouvement pour l'acquisition ou la comparaison des données.
Resumo:
Scoliosis is a 3D deformity of the spine and rib cage. Extensive validation of 3D reconstruction methods of the spine from biplanar radiography has already been published. In this article, we propose a novel method to reconstruct the rib cage, using the same biplanar views as for the 3D reconstruction of the spine, to allow clinical assessment of whole trunk deformities. This technique uses a semi-automatic segmentation of the ribs in the postero-anterior X-ray view and an interactive segmentation of partial rib edges in the lateral view. The rib midlines are automatically extracted in 2D and reconstructed in 3D using the epipolar geometry. For the ribs not visible in the lateral view, the method predicts their 3D shape. The accuracy of the proposed method has been assessed using data obtained from a synthetic bone model as a gold standard and has also been evaluated using data of real patients with scoliotic deformities. Results show that the reconstructed ribs enable a reliable evaluation of the rib axial rotation, which will allow a 3D clinical assessment of the spine and rib cage deformities.
Resumo:
Among the external manifestations of scoliosis, the rib hump, which is associated with the ribs' deformities and rotations, constitutes the most disturbing aspect of the scoliotic deformity for patients. A personalized 3-D model of the rib cage is important for a better evaluation of the deformity, and hence, a better treatment planning. A novel method for the 3-D reconstruction of the rib cage, based only on two standard radiographs, is proposed in this paper. For each rib, two points are extrapolated from the reconstructed spine, and three points are reconstructed by stereo radiography. The reconstruction is then refined using a surface approximation. The method was evaluated using clinical data of 13 patients with scoliosis. A comparison was conducted between the reconstructions obtained with the proposed method and those obtained by using a previous reconstruction method based on two frontal radiographs. A first comparison criterion was the distances between the reconstructed ribs and the surface topography of the trunk, considered as the reference modality. The correlation between ribs axial rotation and back surface rotation was also evaluated. The proposed method successfully reconstructed the ribs of the 6th-12th thoracic levels. The evaluation results showed that the 3-D configuration of the new rib reconstructions is more consistent with the surface topography and provides more accurate measurements of ribs axial rotation.