Resumo:

BACKGROUND: Observational studies on mechanical ventilation (MV) show practice variations across ICUs. We sought to determine, with a case-vignette study, the heterogeneity of processes of care in ICUs focusing on mechanical ventilation procedures, and whether organizational patterns or physician characteristics influence practice variations. METHODS: We conducted a cross-sectional multicenter study using the case-vignette methodology. Descriptive analyses were calculated for each organizational pattern and respondent characteristics. An Index of Qualitative Variation (IQV, from 0, no heterogeneity, to a maximum of 1) was calculated. RESULTS: Forty ICUs from France (N = 33) and Switzerland (N = 7) participated; 396 physicians answered our case-vignettes. There was major heterogeneity of management processes related to MV within and across centers (mean IQV per center 0.51, SD 0.09). We observed the lowest variability (mean IQV per question < 0.4) for questions related to intubation procedure, ventilation of acute respiratory distress syndrome and the use of the semirecumbent position. We observed a high variability (mean IQV per question > 0.6) for questions related to management of endotracheal tube or suctioning, management of sedation and analgesia, and respect of autonomy. Heterogeneity was independent of respondent characteristics and of the presence of written procedures. There was a correlation between the processes associated with the highest variability (mean IQV per question > 0.6) and the annual volume of ICU admission (r = 0.32 (0.01 to 0.58)) and MV (r = 0.38 (0.07 to 0.63)). Within ICUs there was a large heterogeneity regarding knowledge of a local written procedure. CONCLUSIONS: Large clinical practice variations were found among ICUs. High volume centers were more likely to have heterogeneous practices. The presence of a local written procedure or respondent characteristics did not influence practice variation.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

OBJECTIVE: To test a method that allows automatic set-up of the ventilator controls at the onset of ventilation. DESIGN: Prospective randomized crossover study. SETTING: ICUs in one adult and one children's hospital in Switzerland. PATIENTS: Thirty intubated stable, critically ill patients (20 adults and 10 children). INTERVENTIONS: The patients were ventilated during two 20-min periods using a modified Hamilton AMADEUS ventilator. During the control period the ventilator settings were chosen immediately prior to the study. During the other period individual settings were automatically determined by the ventilatior (AutoInit). MEASUREMENTS AND RESULTS: Pressure, flow, and instantaneous CO2 concentration were measured at the airway opening. From these measurements, series dead space (V(DS)), expiratory time constant (RC), tidal volume (VT, total respiratory frequency (f(tot), minute ventilation (MV), and maximal and mean airway pressure (Paw, max and Paw, mean) were calculated. Arterial blood gases were analyzed at the end of each period. Paw, max was significantly less with the AutoInit ventilator settings while f(tot) was significantly greater (P < 0.05). The other values were not statistically significant. CONCLUSIONS: The AutoInit ventilator settings, which were automatically derived, were acceptable for all patients for a period of 20 min and were not found to be inferior to the control ventilator settings. This makes the AutoInit method potentially useful as an automatic start-up procedure for mechanical ventilation.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

OBJECTIVE: To evaluate the influence of nursing on the duration of weaning from mechanical ventilation in patients with chronic obstructive pulmonary disease. DESIGN: Data were collected prospectively over a 1-yr period (study year) and compared with previously collected prospective data recorded in our chronic obstructive pulmonary disease database during a 5-yr period. SETTING: The medical intensive care unit (ICU) of a university hospital. PATIENTS: Eighty-seven patients with chronic obstructive pulmonary disease. Fifteen patients had chronic obstructive pulmonary disease that required mechanical ventilation for acute exacerbation of their disease (study year), and 72 were patients with chronic obstructive pulmonary disease from the previously collected data. INTERVENTIONS: The ICU course (duration of mechanical ventilation, mortality) was recorded, as well as several respiratory parameters (pulmonary function tests and arterial blood gases in stable conditions, and nutritional status), and they were compared with an "index of nursing." MEASUREMENTS AND MAIN RESULTS: We developed an "index of nursing", comparing the effective workforce of the nurses (number and qualifications) with the ideal workforce required by the number of patients and the severity of their diseases. A value of 1.0 represented a perfect match between the needed and the effectively present nurses, whereas a lesser value signified a diminished available workforce. This index was compared with the complications and duration of weaning from mechanical ventilation. During the first 5 yrs, the duration of mechanical ventilation increased progressively from 7.3 +/- 8.0 to 38.2 +/- 25.8 days (p = .006). A significant inverse correlation between the duration of mechanical ventilation and the nursing index (p = .025) was found. In the sixth comparative year, the number of nurses increased (nursing index = 1.05) and the duration of mechanical ventilation decreased to 9.9 +/- 13 days (p < .001, yr 5 vs. yr 6). CONCLUSIONS: The quality of nursing appears to be a measurable and critical factor in the weaning from mechanical ventilation of patients with chronic obstructive pulmonary disease. Below a threshold in the available workforce of ICU nurses, the weaning duration of patients with chronic obstructive pulmonary disease increases dramatically. Therefore, very close attention should be given to the education and number of ICU nurses.

Relevância:

100.00% 100.00%

Publicador:

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Mortality of the acute respiratory distress syndrome (ARDS) remains extremely high and only few evidence-based specific treatments are currently available. Protective mechanical ventilation has emerged as the comer stone of the management of ARDS to avoid the occurrence of ventilation-induced lung injuries (VILI). Mechanical ventilation in the prone position has often been considered as a rescue therapy reserved to refractory hypoxemia. Since the publication of the PROSEVA study in 2013, early prone positioning for mechanical ventilation should be recommended to improve survival of patients with severe ARDS. In this article, both the theoretical and practical aspects of mechanical ventilation in prone position are reviewed.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

STUDY OBJECTIVE: To evaluate the safety of a combined heat and moisture exchanger filter (HMEF) for the conditioning of inspired gas in long-term mechanical ventilation (MV). DESIGN: Randomized controlled trial. SETTING: Medical ICU in a large teaching hospital. PATIENTS: One hundred fifteen consecutive patients who required > or = 48 h of MV. INTERVENTIONS: Patients were randomized at intubation time (day 1) to receive inspired gas conditioned either by a water-bath humidifier heated at 32 degrees C (HWBH) or by an HMEF (Hygroster; DAR; Mirandola, Italy). MEASUREMENTS AND MAIN RESULTS: The two study groups were comparable in terms of primary pathologic condition at the time of hospital admission, disease severity as measured by the Simplified Acute Physiology Score, and ICU mortality. They did not differ with respect to ventilator days per patient (mean +/- SD: HMEF, 7.6 +/- 6.5; HWBH, 7.8 +/- 5.8), incidence of endotracheal tube obstruction (HMEF, 0/59; HWBH, 1/56), and incidence of hypothermic episodes (HMEF, five; HWBH, two). In 41 patients receiving MV for > or = 5 days, the morphologic integrity of respiratory epithelium was evaluated on day 1 and day 5, using a cytologic examination of tracheal aspirate smears. The state of ciliated epithelium was scored on a scale from 0 (poorest integrity) to 1,200 (maximum integrity), according to a well-described method. In both patient groups, the scores slightly but significantly decreased from day 1 to day 5 (mean +/- SD: HWBH, from 787 +/- 104 to 745 +/- 88; HMEF, from 813 +/- 79 to 739 +/- 62; p < 0.01 for both groups); there were no statistically significant differences between groups. CONCLUSIONS: These data indicate acceptable safety of HMEFs of the type used in the present study for long-term mechanical ventilation.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Positive pressure ventilation (PPV) is a frequent intervention in the neonatal intensive care unit. This article is directed towards paediatricians in training and attempts to cover the basics of PPV without being too technical. To do so we have employed an extensive use of graphics to illustrate the underlying principles.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

High frequency oscillatory ventilation (HFOV) is becoming an increasingly popular intervention in the neonatal intensive care unit. This article will attempt to explain the principles of HFOV. It is inherently more difficult to become skilled in this technique than in other forms of mechanical ventilation, so caution is warranted.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Neurally adjusted ventilatory assist or NAVA is a new assisted ventilatory mode which, in comparison with pressure support, leads to improved patient-ventilator synchrony and a more variable ventilatory pattern. It also improves arterial oxygenation. With NAVA, the electrical activity of the diaphragm is recorded through a nasogastric tube equipped with electrodes. This electrical activity is then used to pilot the ventilator. With NAVA, the patient's respiratory pattern controls the ventilator's timing of triggering and cycling as well as the magnitude of pressurization, which is proportional to inspiratory demand. The effect of NAVA on patient outcome remains to be determined through well-designed prospective studies.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The new-generation nebulizers are commonly used for the administration of salbutamol in mechanically ventilated patients. The different modes of administration and new devices have not been compared. We developed a liquid chromatography-tandem mass spectrometry method for the determination of concentrations as low as 0.05 ng/mL of salbutamol, corresponding to the desired plasma concentration after inhalation. Salbutamol quantification was performed by reverse-phase HPLC. Analyte quantification was performed by electrospray ionization-triple quadrupole mass spectrometry using selected reaction monitoring detection ESI in the positive mode. The method was validated over concentrations ranging from 0.05 to 100 ng/mL in plasma and from 0.18 to 135 ng/mL in urine. The method is precise, with mean inter-day coefficient of variation (CV%) within 3.1-8.3% in plasma and 1.3-3.9% in urine, as well as accurate. The proposed method was found to reach the required sensitivity for the evaluation of different nebulizers as well as nebulization modes. The present assay was applied to examine whether salbutamol urine levels, normalized with the creatinine levels, correlated with the plasma concentrations. A suitable, convenient and noninvasive method of monitoring patients receiving salbutamol by mechanical ventilation could be implemented. Copyright © 2011 John Wiley & Sons, Ltd.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Résumant mon travail de thèse, l'article qui suit décrit un nouveau modèle animal servant à étudier l'impact combiné d'une ventilation mécanique (VM), d'une oxygénothérapie et d'une inflammation sur des poumons immatures. Cette étude permet, pour la première fois, de mesurer l'expression de gènes à distance d'une VM pour en analyser la cinétique. La VM représente un traitement intégral dans la prise en charge de prématurés. Sauvant des vies, elle est cependant non-physiologique et décrite comme nocive à court et à long terme, empêchant le bon développement pulmonaire. Nombreuses études se sont intéressées à l'impact immédiat de la VM sur les poumons, mais il n'existe à ce jour aucun modèle de rongeur pour en analyser les effets tardifs. Par analogie avec la clinique, nous avons créé un modèle avec un animal dont le stade développemental pulmonaire est comparable aux prématurés humains et consistant en une oxygénothérapie, une VM modérée avec intubation non chirurgicale, similaire à la pratique quotidienne, et un contexte inflammatoire mimant celui de chorioamnionite dans lequel bien des prématurés naissent. Nous avons ensuite réalisé une extubation pour permettre une période de rétablissement, puis fait des analyses et sur le plan structurel par histologie conventionnelle et en 3D, et sur le plan biologique, par analyse de l'expression de gènes et de protéines. Ce travail a permis de valider ce nouveau modèle comme outil de recherche pour réaliser des mesures à distance d'une VM chez des rats nouveau-nés. Comparant ces mesures à celles prises à la fin de la VM, nous observons: une augmentation initiale et transitoire des médiateurs impliqués dans la cascade inflammatoire dont le corrélat histologique est une maladie inflammatoire pulmonaire et, tardivement, une altération plus développementale de la structure pulmonaire avec diminution de l'alvéolarisation. Ceci pourrait être en partie dû à une expression asynchrone de gènes décrits comme importants pour la formation des alvéoles (matrix metalloproteinase 9, elastine). Offrant une nouvelle approche pour la recherche pulmonaire chez les rongeurs, ce modèle servira comme futur outil pour approfondir nos connaissances de la physiopathologie conduisant aux altérations structurelles retrouvées dans les poumons d'anciens prématurés soumis à une VM (dysplasie broncho-pulmonaire), pour tester l'influence de certains traitements (p.ex. surfactant) et pour étudier les effets de la VM en l'appliquant à des modèles transgéniques.