958 resultados para Intra-examiner reproducibility
Resumo:
The aim of the study was to determine the reproducibility and validity of DIAGNOdent in detecting active and arrested caries lesions on free smooth surfaces. Volunteers were selected from state schools of Piracicaba, São Paulo, Brazil. Overall, 220 lesions were clinically examined. Two specially trained ('calibrated') examiners performed both clinical and laser evaluations independently, and after a 1-week interval, the examinations were repeated, the intra-examiner agreement for the laser evaluation was substantial (kappa(ex1) = 0.79, kappa(ex2) = 0.71). There was almost perfect agreement between the two examiners for the clinical examination (kappa(ex1) = 0.95, kappa(ex2) = 0.85). The inter-examiner agreement showed substantial reproducibility (kappa = 0.77) for the laser examination and almost perfect agreement (kappa = 0.85) for the clinical evaluation. The validation criterion was the clinical examination of white spots, recorded as active or arrested. The sensitivity was 0.72 and the specificity was 0.73, which indicates that the DIAGNOdent was a good auxiliary method for detecting incipient caries lesions on free smooth surfaces. The utilization of both methods can improve the efficacy of caries diagnosis. Copyright (C) 2002 S. Karger AG, Basel.
Resumo:
Objective: To present the Instrumento de Avaliação da Promoção da Saúde na Universidade – IAPSU (Assessment Tool for Health Promotion at the University) and its reproducibility assessment process. Methods: Cross-sectional study conducted between May and July 2014 with 50 students from a university of Fortaleza, Ceará, which developed the IAPSU through the analysis of government documents and a systematic review of the literature on a potentially healthy university. The tool has 41 questions divided into five domains: physical activity, diet, environmental factors, psychosocial factors and alcohol and drug use, integrative and complementary practices. To assess the inter-examiner reproducibility, the students answered the IAPSU twice, applied by two different examiners; to assess the intraexaminer reproducibility, another application of the instrument was performed after seven days. Results: The study comprised 40 Nursing students and 10 Physical Therapy students, with a mean age of 25 ± 5.4 years; 88% were women and white individuals were predominant. In the reproducibility assessment, strong intraclass, intra- and inter-examiner correlation coefficients - above 0.8 - were observed in all the domains. Conclusion: The IAPSU is a reproducible and reliable instrument for assessing health promotion at the university.
Resumo:
The aim of this study was to determine the effectiveness and reliability of laser fluorescence measurements in relation to occlusal caries diagnosis. DIAGNOdent 2095 (Kavo, Biberach, Germany), which has been developed especially for caries diagnosis, was utilized. Five (5) teeth were examined in the pilot test; after that, ten (10) teeth were examined in order to calibrate both examiners. Data were obtained from 66 teeth (36 molars and 30 premolars), totalizing 144 sites identified through photographs of the occlusal surfaces. Reproducibility was evaluated in 10 teeth. The interexaminer Spearman correlation (r) was 0.89 and the intra-examiner, 0.93 and 0.97 (examiner A and B, respectively). Validation was carried out by histological examination (stereomicroscope). For the two examiners the sensitivity of the device was relatively high, varying from 0.81 to 1.00, while specificity varied according to which validation criterion was used (0.77 - 0.86: enamel lesion / 0.52 - 0.59: dentin lesion). It was concluded that DIAGNodent presented good capacity of identifying any alteration of the dental surface, nevertheless it presents the disadvantage of accomplishing many false-positive diagnosis when the validation criterion is dentin lesion.
Resumo:
This study vas aimed to validate the American Speech-Language-Hearing Association Functional Assessment Of Communication Skills (ASHA FACS) for a Brazilian population. The scale was translated and adapted into Portuguese. Thirty-two patients with mild Alzheimer disease (AD). 25 patients with moderate AD. and 51 elderly without dementia were examined with Mini Mental State Examination, Geriatric Depression Scale. and Alzheimer Disease Assessment Scale-Cognitive subscale (ADAS-cog). The ASHA FACS was answered by their relative/caregiver. The scale`s internal consistency. its inter-examiner and intra-examiner`s reproducibility. and scale`s criterion validity were researched by correlation with ADAS-cog,. The sensitivity and specificity Were also researched. Statistical analyses indicated that the ASHA FACS has excellent internal consistency (Cronbach alpha = 0.955), test-retest reliability (interclass correlation coefficient = 0.995; P < 0.001). and inter-examiners (interclass correlation coefficient = 0.998: P < 0.001). It showed excellent criterion validity when correlated with ADAS-cog,. The ASHA FACS scale showed good sensitivity (75.0%) and specificity (82.4%) values once it is an ecologic and broad evaluation. The ASHA FACS Portuguese version is a valid and reliable instrument to verify communication alterations in AD patients and fills an important gap of efficiency indicators for speech language therapy in our country.
Resumo:
Purpose: To compare visual inspection (VI), radiographic examination (RX) and the laser fluorescence device DIAGNOdent (L), as well as their combinations in vitro regarding treatment decisions for occlusal surfaces. Methods: 72 extracted human permanent teeth (molars and premolars) were used. Treatment decisions were recorded by three calibrated examiners, and the options available were fissure sealant and conservative restoration. For validation of treatment decisions, the teeth were sectioned and examined in a stereomicroscope. Thereafter, dental slices were scanned and the images were edited to facilitate classification of existing carious lesions. Intra and inter-examiner reproducibility for the determination of treatment plans were calculated using Cohen`s kappa test (95%-CI). Sensitivity, specificity, positive and negative predictive values, and the area under the ROC curve were also calculated. Results: VI and L provided on average the greatest intra- and inter-examiner reproducibility, respectively. Although the combination of diagnostic methods may decrease both intra- and inter examiners reproducibility, combination of VI, L and RX resulted in the greatest sensitivity, being statistically superior to RX and L. There was more inter-examiner agreement for the option of restorative treatment, while the use of sealants as a treatment option yielded the lowest values. Negative predictive values were numerically inferior to positive predictive values, indicating that the examiners preferred not to restore a carious tooth than to proceed operatively in an intact tooth. The combination of the three methods studied showed the best results in determining treatment plans for occlusal surfaces, when compared to the other types of exams. On the other hand, radiographic examination and laser fluorescence were less efficient when used alone.
Resumo:
The objective of this study was to investigate whether it is possible to pool together diffusion spectrum imaging data from four different scanners, located at three different sites. Two of the scanners had identical configuration whereas two did not. To measure the variability, we extracted three scalar maps (ADC, FA and GFA) from the DSI and utilized a region and a tract-based analysis. Additionally, a phantom study was performed to rule out some potential factors arising from the scanner performance in case some systematic bias occurred in the subject study. This work was split into three experiments: intra-scanner reproducibility, reproducibility with twin-scanner settings and reproducibility with other configurations. Overall for the intra-scanner and twin-scanner experiments, the region-based analysis coefficient of variation (CV) was in a range of 1%-4.2% and below 3% for almost every bundle for the tract-based analysis. The uncinate fasciculus showed the worst reproducibility, especially for FA and GFA values (CV 3.7-6%). For the GFA and FA maps, an ICC value of 0.7 and above is observed in almost all the regions/tracts. Looking at the last experiment, it was found that there is a very high similarity of the outcomes from the two scanners with identical setting. However, this was not the case for the two other imagers. Given the fact that the overall variation in our study is low for the imagers with identical settings, our findings support the feasibility of cross-site pooling of DSI data from identical scanners.
Resumo:
Heart rate variability (HRV) provides important information about cardiac autonomic modulation. Since it is a noninvasive and inexpensive method, HRV has been used to evaluate several parameters of cardiovascular health. However, the internal reproducibility of this method has been challenged in some studies. Our aim was to determine the intra-individual reproducibility of HRV parameters in short-term recordings obtained in supine and orthostatic positions. Electrocardiographic (ECG) recordings were obtained from 30 healthy subjects (20-49 years, 14 men) using a digital apparatus (sampling ratio = 250 Hz). ECG was recorded for 10 min in the supine position and for 10 min in the orthostatic position. The procedure was repeated 2-3 h later. Time and frequency domain analyses were performed. Frequency domain included low (LF, 0.04-0.15 Hz) and high frequency (HF, 0.15-0.4 Hz) bands. Power spectral analysis was performed by the autoregressive method and model order was set at 16. Intra-subject agreement was assessed by linear regression analysis, test of difference in variances and limits of agreement. Most HRV measures (pNN50, RMSSD, LF, HF, and LF/HF ratio) were reproducible independent of body position. Better correlation indexes (r > 0.6) were obtained in the orthostatic position. Bland-Altman plots revealed that most values were inside the agreement limits, indicating concordance between measures. Only SDNN and NNv in the supine position were not reproducible. Our results showed reproducibility of HRV parameters when recorded in the same individual with a short time between two exams. The increased sympathetic activity occurring in the orthostatic position probably facilitates reproducibility of the HRV indexes.
Resumo:
Purpose: To compare visual inspection (VI), radiographic examination (RX) and the laser fluorescence device DIAGNOdent (L), as well as their combinations in vitro regarding treatment decisions for occlusal surfaces. Methods: 72 extracted human permanent teeth (molars and premolars) were used. Treatment decisions were recorded by three calibrated examiners, and the options available were fissure sealant and conservative restoration. For validation of treatment decisions, the teeth were sectioned and examined in a stereomicroscope. Thereafter, dental slices were scanned and the images were edited to facilitate classification of existing carious lesions. Intra and inter-examiner reproducibility for the determination of treatment plans were calculated using Cohen's kappa test (95%-CI). Sensitivity, specificity, positive and negative predictive values, and the area under the ROC curve were also calculated. Results: VI and L provided on average the greatest intra- and inter-examiner reproducibility, respectively. Although the combination of diagnostic methods may decrease both intra- and inter examiners reproducibility, combination of VI, L and RX resulted in the greatest sensitivity, being statistically superior to RX and L. There was more inter-examiner agreement for the option of restorative treatment, while the use of sealants as a treatment option yielded the lowest values. Negative predictive values were numerically inferior to positive predictive values, indicating that the examiners preferred not to restore a carious tooth than to proceed operatively in an intact tooth. The combination of the three methods studied showed the best results in determining treatment plans for occlusal surfaces, when compared to the other types of exams. on the other hand, radiographic examination and laser fluorescence were less efficient when used alone.
Resumo:
The aim of this study was to compare the in situ and in vitro performances of a laser fluorescence (LF) device (DIAGNOdent 2095) with visual inspection for the detection of occlusal caries in permanent teeth. Sixty-four sites were selected, and visual inspection and LF assessments were carried out, in vitro, three times by two independent examiners, with a 1-week interval between evaluations. Afterwards, the occlusal surfaces were mounted on the palatal portion of removable acrylic orthodontic appliances and placed in six volunteers. Assessments were repeated and validated by histological analysis of the tooth sections under a stereomicroscope. For both examiners, the highest intra-examiner values were observed for the visual inspection when in vitro and in situ evaluations were compared. The inter-examiner reproducibility varied from 0.61 to 0.64, except for the in vitro assessment using LF, which presented a lower value (0.43). The methods showed high specificity at the D(1) threshold (considering enamel and dentin caries as disease). In vitro evaluations showed the highest values of sensitivity for both methods when compared to the in situ evaluations at D(1) and D(2) (considering only dentinal caries as the disease) thresholds. For both methods, the results of sensitivity (at D(1) and D(2)) and accuracy (at D(1)) showed significant differences between in vitro and in situ conditions. However, the sensitivity (at D(1) and D(2)), specificity and accuracy (both at D(1)) of the methods were not significantly different when the same condition was considered. It can be concluded that visual inspection and LF showed better performance in vitro than in situ.
Resumo:
OBJETIVO: o presente estudo teve como objetivo propor um método para classificação, segundo a severidade, dos indivíduos Padrão Face Longa, avaliando sua confiabilidade e reprodutibilidade. METODOLOGIA: foram utilizadas fotografias faciais (frontal, perfil e frontal sorrindo) de 125 crianças Padrão Face Longa (54 do gênero feminino e 71 do gênero masculino), selecionadas apenas considerando-se a morfologia facial, com idades entre 10 anos e 6 meses e 15 anos e 2 meses. As fotografias foram avaliadas, separadamente, por três examinadores, sendo reavaliadas após três semanas, em uma nova disposição aleatória. Os indivíduos foram graduados em três subtipos, de acordo com a severidade: moderado, médio e severo. Para avaliar as concordâncias intra e interexaminadores, foi utilizada a estatística Kappa (k). RESULTADOS: na avaliação intra-examinador, todos os examinadores obtiveram concordâncias substanciais, com o valor de Kappa variando de 0,64 a 0,66, havendo em todos os examinadores 80% ou mais de concordância. Quando comparadas as avaliações interexaminadores, as freqüências de concordância diminuíram, variando de 67,2% a 70,4%. A partir dos valores de Kappa, que variaram de 0,41 a 0,46, a interpretação foi considerada moderada. CONCLUSÕES: com base nesses resultados, o método foi considerado aplicável, com necessidade de complemento de informações provenientes de outros exames rotineiramente aplicados em Ortodontia. A aplicação clínica será demonstrada com intuito de evidenciar os níveis diferentes de severidade das más oclusões do Padrão Face Longa e as características do protocolo de tratamento recomendado.
Resumo:
The reproducibility and validity of self-perceived periodontal, dental, and temporomandibular joint (TMJ) conditions were investigated. A questionnaire was applied in interview to 200 adults aged from 35 to 44, who were attending as casual patients at Araraquara School of Dentistry, Sauo Paulo State University, Sauo Paulo, Brazil. Clinical examination was based on the guidelines of the World Health Organization manual. The interview and the clinical examination were performed in two occasions, by a calibrated examiner. Reproducibility and validity were, respectively, verified by kappa statistics (kappa) and sensitivity (Sen) and specificity (Spec) values, having clinical examination as the validation criterion. The results showed an almost perfect agreement for self-perceived TMJ (kappa=0.85) and periodontal conditions (kappa=0.81), and it was substantial for dental condition (kappa=0.69). Reproducibility according to clinical examination showed good results (kappa=0.73 for CPI index, kappa=0.96 for dental caries, and kappa=0.74 for TMJ conditions). Sensitivity and specificity values were higher for self-perceived dental (Sen=0.84, Spec=1.0) and TMJ conditions (Sen=1.0, Spec=0.8). With regard to periodontal condition, specificity was low (0.43), although sensitivity was very high (1.0). Self-perceived oral health was reliable for the examined conditions. Validity was good to detect dental conditions and TMJ disorders, and it was more sensitive than specific to detect the presence of periodontal disease.
Resumo:
Objective: To evaluate the prevalence of dental fluorosis in scholars aging 12 to 15 years old, residents in the city of Bauru, State of São Paulo, Brazil. Methods: 1318 volunteers were enrolled in this study and examined in 18 public schools of the State of São Paulo. The examinations were performed in the schools' court by three dentists (with a Master's degree in Public Health), after toothbrushing supervised by another dentist. The teeth were dried with cotton pellets and examined under natural light by visual inspection, using an explorer as recommended by the WHO, a plane mirror and a tongue depressor. The Thylstrup-Fejerskov (TF) index was used for rating fluorosis. Intra and inter-examiner reproducibility was calculated and data were submitted to descriptive analysis. Results: Approximately 36% of the children presented dental fluorosis, of which 28% was diagnosed as TF1 while the remaining received scores between TF2 and TF4. Conclusion: The prevalence of dental fluorosis in Bauru is within the expected range, based on previous studies. Although fluoride is an important resource for caries control, its use must be adequate to the needs of each specific population.
Resumo:
Pós-graduação em Ciências Odontológicas - FOAR
Resumo:
The aim of this study was to investigate the reliability of visual and digital methods to assess marginal microleakage in vitro. Materials and Methods: Typical Class V preparations were made in bovine teeth and filled with composite resin. After dye penetration (0.5% basic fuchsin), teeth were sectioned and the 53 obtained fragments were assessed according to visual (stereomicroscope) and digital methods (Image Tool Software ® -ITS) (University of Texas Health Science Center-San Antonio Dental School, USA). Two calibrated examiners (A and B) evaluated dye penetration, by means of a stereomicroscope with ×20 magnification (scores), and by the ITS (millimeters). The intra- and inter-examiner agreement was estimated according to Kappa statistics (κ), and intraclass correlation coefficient (ρ). Results: In relation to the visual method, the intra-examiner agreement was almost perfect (κA = 0.87) and substantial (κB = 0.76), respectively to the examiner A and B. The inter-examiner agreement showed an almost perfect reliability (κ = 0.84). For the digital method, the intra-examiner agreement was almost perfect for both examiners and equal to ρ = 0.99, and so was the inter-examiner agreement value. Conclusion: Visual (stereomicroscope) and digital methods (ITS) showed high levels of intra- and inter-examiner reproducibility when marginal microleakage was assessed.
Resumo:
Digital models are an alternative for carrying out analyses and devising treatment plans in orthodontics. The objective of this study was to evaluate the accuracy and the reproducibility of measurements of tooth sizes, interdental distances and analyses of occlusion using plaster models and their digital images. Thirty pairs of plaster models were chosen at random, and the digital images of each plaster model were obtained using a laser scanner (3Shape R-700, 3Shape A/S). With the plaster models, the measurements were taken using a caliper (Mitutoyo Digimatic(®), Mitutoyo (UK) Ltd) and the MicroScribe (MS) 3DX (Immersion, San Jose, Calif). For the digital images, the measurement tools used were those from the O3d software (Widialabs, Brazil). The data obtained were compared statistically using the Dahlberg formula, analysis of variance and the Tukey test (p < 0.05). The majority of the measurements, obtained using the caliper and O3d were identical, and both were significantly different from those obtained using the MS. Intra-examiner agreement was lowest when using the MS. The results demonstrated that the accuracy and reproducibility of the tooth measurements and analyses from the plaster models using the caliper and from the digital models using O3d software were identical.