869 resultados para Interval sampling
Resumo:
Despite extensive efforts to confirm a direct association between Chlamydia pneumoniae and atherosclerosis, different laboratories continue to report a large variability in detection rates. In this study, we analyzed multiple sections from atherosclerotic carotid arteries from 10 endartectomy patients to determine the location of C. pneumoniae DNA and the number of sections of the plaque required for analysis to obtain a 95% confidence of detecting the bacterium. A sensitive nested PCR assay detected C. pneumoniae DNA in all patients at one or more locations within the plaque. On average, 42% (ranging from 5 to 91%) of the sections from any single patient had C. pneumoniae DNA present. A patchy distribution of C. pneumoniae in the atherosclerotic lesions was observed, with no area of the carotid having significantly more C. pneumoniae DNA present. If a single random 30-mum-thick section was tested, there was only a 35.6 to 41.6% (95% confidence interval) chance of detecting C. pneumoniae DNA in a patient with carotid artery disease. A minimum of 15 sections would therefore be required to obtain a 95% chance of detecting all true positives. The low concentration and patchy distribution of C. pneumoniae DNA in atherosclerotic plaque appear to be among the reasons for inconsistency between laboratories in the results reported.
Resumo:
There has been a resurgence of interest in the mean trace length estimator of Pahl for window sampling of traces. The estimator has been dealt with by Mauldon and Zhang and Einstein in recent publications. The estimator is a very useful one in that it is non-parametric. However, despite some discussion regarding the statistical distribution of the estimator, none of the recent works or the original work by Pahl provide a rigorous basis for the determination a confidence interval for the estimator or a confidence region for the estimator and the corresponding estimator of trace spatial intensity in the sampling window. This paper shows, by consideration of a simplified version of the problem but without loss of generality, that the estimator is in fact the maximum likelihood estimator (MLE) and that it can be considered essentially unbiased. As the MLE, it possesses the least variance of all estimators and confidence intervals or regions should therefore be available through application of classical ML theory. It is shown that valid confidence intervals can in fact be determined. The results of the work and the calculations of the confidence intervals are illustrated by example. (C) 2003 Elsevier Science Ltd. All rights reserved.
Resumo:
The precise sampling of soil, biological or micro climatic attributes in tropical forests, which are characterized by a high diversity of species and complex spatial variability, is a difficult task. We found few basic studies to guide sampling procedures. The objective of this study was to define a sampling strategy and data analysis for some parameters frequently used in nutrient cycling studies, i. e., litter amount, total nutrient amounts in litter and its composition (Ca, Mg, Κ, Ν and P), and soil attributes at three depths (organic matter, Ρ content, cation exchange capacity and base saturation). A natural remnant forest in the West of São Paulo State (Brazil) was selected as study area and samples were collected in July, 1989. The total amount of litter and its total nutrient amounts had a high spatial independent variance. Conversely, the variance of litter composition was lower and the spatial dependency was peculiar to each nutrient. The sampling strategy for the estimation of litter amounts and the amount of nutrient in litter should be different than the sampling strategy for nutrient composition. For the estimation of litter amounts and the amount of nutrients in litter (related to quantity) a large number of randomly distributed determinations are needed. Otherwise, for the estimation of litter nutrient composition (related to quality) a smaller amount of spatially located samples should be analyzed. The determination of sampling for soil attributes differed according to the depth. Overall, surface samples (0-5 cm) showed high short distance spatial dependent variance, whereas, subsurface samples exhibited spatial dependency in longer distances. Short transects with sampling interval of 5-10 m are recommended for surface sampling. Subsurface samples must also be spatially located, but with transects or grids with longer distances between sampling points over the entire area. Composite soil samples would not provide a complete understanding of the relation between soil properties and surface dynamic processes or landscape aspects. Precise distribution of Ρ was difficult to estimate.
Resumo:
The uncertainty of any analytical determination depends on analysis and sampling. Uncertainty arising from sampling is usually not controlled and methods for its evaluation are still little known. Pierre Gy’s sampling theory is currently the most complete theory about samplingwhich also takes the design of the sampling equipment into account. Guides dealing with the practical issues of sampling also exist, published by international organizations such as EURACHEM, IUPAC (International Union of Pure and Applied Chemistry) and ISO (International Organization for Standardization). In this work Gy’s sampling theory was applied to several cases, including the analysis of chromite concentration estimated on SEM (Scanning Electron Microscope) images and estimation of the total uncertainty of a drug dissolution procedure. The results clearly show that Gy’s sampling theory can be utilized in both of the above-mentioned cases and that the uncertainties achieved are reliable. Variographic experiments introduced in Gy’s sampling theory are beneficially applied in analyzing the uncertainty of auto-correlated data sets such as industrial process data and environmental discharges. The periodic behaviour of these kinds of processes can be observed by variographic analysis as well as with fast Fourier transformation and auto-correlation functions. With variographic analysis, the uncertainties are estimated as a function of the sampling interval. This is advantageous when environmental data or process data are analyzed as it can be easily estimated how the sampling interval is affecting the overall uncertainty. If the sampling frequency is too high, unnecessary resources will be used. On the other hand, if a frequency is too low, the uncertainty of the determination may be unacceptably high. Variographic methods can also be utilized to estimate the uncertainty of spectral data produced by modern instruments. Since spectral data are multivariate, methods such as Principal Component Analysis (PCA) are needed when the data are analyzed. Optimization of a sampling plan increases the reliability of the analytical process which might at the end have beneficial effects on the economics of chemical analysis,
Resumo:
Bioanalytical data from a bioequivalence study were used to develop limited-sampling strategy (LSS) models for estimating the area under the plasma concentration versus time curve (AUC) and the peak plasma concentration (Cmax) of 4-methylaminoantipyrine (MAA), an active metabolite of dipyrone. Twelve healthy adult male volunteers received single 600 mg oral doses of dipyrone in two formulations at a 7-day interval in a randomized, crossover protocol. Plasma concentrations of MAA (N = 336), measured by HPLC, were used to develop LSS models. Linear regression analysis and a "jack-knife" validation procedure revealed that the AUC0-¥ and the Cmax of MAA can be accurately predicted (R²>0.95, bias <1.5%, precision between 3.1 and 8.3%) by LSS models based on two sampling times. Validation tests indicate that the most informative 2-point LSS models developed for one formulation provide good estimates (R²>0.85) of the AUC0-¥ or Cmax for the other formulation. LSS models based on three sampling points (1.5, 4 and 24 h), but using different coefficients for AUC0-¥ and Cmax, predicted the individual values of both parameters for the enrolled volunteers (R²>0.88, bias = -0.65 and -0.37%, precision = 4.3 and 7.4%) as well as for plasma concentration data sets generated by simulation (R²>0.88, bias = -1.9 and 8.5%, precision = 5.2 and 8.7%). Bioequivalence assessment of the dipyrone formulations based on the 90% confidence interval of log-transformed AUC0-¥ and Cmax provided similar results when either the best-estimated or the LSS-derived metrics were used.
Resumo:
To provide reliable estimates for mapping soil properties for precision agriculture requires intensive sampling and costly laboratory analyses. If the spatial structure of ancillary data, such as yield, digital information from aerial photographs, and soil electrical conductivity (EC) measurements, relates to that of soil properties they could be used to guide the sampling intensity for soil surveys. Variograins of permanent soil properties at two study sites on different parent materials were compared with each other and with those for ancillary data. The ranges of spatial dependence identified by the variograms of both sets of properties are of similar orders of magnitude for each study site, Maps of the ancillary data appear to show similar patterns of variation and these seem to relate to those of the permanent properties of the soil. Correlation analysis has confirmed these relations. Maps of kriged estimates from sub-sampled data and the original variograrns showed that the main patterns of variation were preserved when a sampling interval of less than half the average variogram range of ancillary data was used. Digital data from aerial photographs for different years and EC appear to show a more consistent relation with the soil properties than does yield. Aerial photographs, in particular those of bare soil, seem to be the most useful ancillary data and they are often cheaper to obtain than yield and EC data.
Resumo:
It has been generally accepted that the method of moments (MoM) variogram, which has been widely applied in soil science, requires about 100 sites at an appropriate interval apart to describe the variation adequately. This sample size is often larger than can be afforded for soil surveys of agricultural fields or contaminated sites. Furthermore, it might be a much larger sample size than is needed where the scale of variation is large. A possible alternative in such situations is the residual maximum likelihood (REML) variogram because fewer data appear to be required. The REML method is parametric and is considered reliable where there is trend in the data because it is based on generalized increments that filter trend out and only the covariance parameters are estimated. Previous research has suggested that fewer data are needed to compute a reliable variogram using a maximum likelihood approach such as REML, however, the results can vary according to the nature of the spatial variation. There remain issues to examine: how many fewer data can be used, how should the sampling sites be distributed over the site of interest, and how do different degrees of spatial variation affect the data requirements? The soil of four field sites of different size, physiography, parent material and soil type was sampled intensively, and MoM and REML variograms were calculated for clay content. The data were then sub-sampled to give different sample sizes and distributions of sites and the variograms were computed again. The model parameters for the sets of variograms for each site were used for cross-validation. Predictions based on REML variograms were generally more accurate than those from MoM variograms with fewer than 100 sampling sites. A sample size of around 50 sites at an appropriate distance apart, possibly determined from variograms of ancillary data, appears adequate to compute REML variograms for kriging soil properties for precision agriculture and contaminated sites. (C) 2007 Elsevier B.V. All rights reserved.
Resumo:
An unbalanced nested sampling design was used to investigate the spatial scale of soil and herbicide interactions at the field scale. A hierarchical analysis of variance based on residual maximum likelihood (REML) was used to analyse the data and provide a first estimate of the variogram. Soil samples were taken at 108 locations at a range of separating distances in a 9 ha field to explore small and medium scale spatial variation. Soil organic matter content, pH, particle size distribution, microbial biomass and the degradation and sorption of the herbicide, isoproturon, were determined for each soil sample. A large proportion of the spatial variation in isoproturon degradation and sorption occurred at sampling intervals less than 60 m, however, the sampling design did not resolve the variation present at scales greater than this. A sampling interval of 20-25 m should ensure that the main spatial structures are identified for isoproturon degradation rate and sorption without too great a loss of information in this field.
Resumo:
Despite the fact that mites were used at the dawn of forensic entomology to elucidate the postmortem interval, their use in current cases remains quite low for procedural reasons such as inadequate taxonomic knowledge. A special interest is focused on the phoretic stages of some mite species, because the phoront-host specificity allows us to deduce in many occasions the presence of the carrier (usually Diptera or Coleoptera) although it has not been seen in the sampling performed in situ or in the autopsy room. In this article, we describe two cases where Poecilochirus austroasiaticus Vitzthum (Acari: Parasitidae) was sampled in the autopsy room. In the first case, we could sample the host, Thanatophilus ruficornis (Küster) (Coleoptera: Silphidae), which was still carrying phoretic stages of the mite on the body. That attachment allowed, by observing starvation/feeding periods as a function of the digestive tract filling, the establishment of chronological cycles of phoretic behavior, showing maximum peaks of phoronts during arrival and departure from the corpse and the lowest values in the phase of host feeding. From the sarcosaprophagous fauna, we were able to determine in this case a minimum postmortem interval of 10 days. In the second case, we found no Silphidae at the place where the corpse was found or at the autopsy, but a postmortem interval of 13 days could be established by the high specificity of this interspecific relationship and the departure from the corpse of this family of Coleoptera.
Resumo:
We discuss the development and performance of a low-power sensor node (hardware, software and algorithms) that autonomously controls the sampling interval of a suite of sensors based on local state estimates and future predictions of water flow. The problem is motivated by the need to accurately reconstruct abrupt state changes in urban watersheds and stormwater systems. Presently, the detection of these events is limited by the temporal resolution of sensor data. It is often infeasible, however, to increase measurement frequency due to energy and sampling constraints. This is particularly true for real-time water quality measurements, where sampling frequency is limited by reagent availability, sensor power consumption, and, in the case of automated samplers, the number of available sample containers. These constraints pose a significant barrier to the ubiquitous and cost effective instrumentation of large hydraulic and hydrologic systems. Each of our sensor nodes is equipped with a low-power microcontroller and a wireless module to take advantage of urban cellular coverage. The node persistently updates a local, embedded model of flow conditions while IP-connectivity permits each node to continually query public weather servers for hourly precipitation forecasts. The sampling frequency is then adjusted to increase the likelihood of capturing abrupt changes in a sensor signal, such as the rise in the hydrograph – an event that is often difficult to capture through traditional sampling techniques. Our architecture forms an embedded processing chain, leveraging local computational resources to assess uncertainty by analyzing data as it is collected. A network is presently being deployed in an urban watershed in Michigan and initial results indicate that the system accurately reconstructs signals of interest while significantly reducing energy consumption and the use of sampling resources. We also expand our analysis by discussing the role of this approach for the efficient real-time measurement of stormwater systems.
Resumo:
O presente estudo avaliou a digestibilidade aparente da proteína e da energia de ingredientes (farelo de soja, farinha de peixe, farelo de trigo e milho) por juvenis de apaiari (Astronotus ocellatus) usando dois diferentes intervalos de coleta (30 min. e 12h). Os 160 juvenis de apaiari utilizados (22,37 ± 3,06 g de peso corporal) foram divididos em quatro tanques rede plásticos e cilíndricos, cada um colocado em um tanque de alimentação de 1.000 L. O experimento foi inteiramente casualizado em esquema fatorial 2 x 4 (2 intervalos de coleta de fezes e 4 ingredientes foram) com quatro repetições. Os testes estatísticos não detectaram efeito da interação entre o intervalo de coleta e tipo de ingrediente nos coeficientes de digestibilidade. O intervalo de coleta não afetou a digestibilidade da proteína e da energia. As características físicas das fezes dos juvenis de apaiari aparentemente as tornam menos sensíveis à perda de nutrientes por lixiviação, permitindo intervalos de coleta maiores. A digestibilidade da proteína dos ingredientes avaliados foi semelhante, mostrando que a digestibilidade aparente de ingredientes animais e vegetais por juvenis de apaiari é eficiente. Os coeficientes de digestibilidade da energia foram maiores para a farinha de peixe e o farelo de soja comparado a farelo de trigo e milho. Ingredientes ricos em carboidratos (farelo de trigo e milho) apresentaram os piores coeficientes de digestibilidade da energia e, portanto, não são usados eficientemente pelos juvenis de apaiari.
Resumo:
In this article, we consider the T(2) chart with double sampling to control bivariate processes (BDS chart). During the first stage of the sampling, n(1) items of the sample are inspected and two quality characteristics (x; y) are measured. If the Hotelling statistic T(1)(2) for the mean vector of (x; y) is less than w, the sampling is interrupted. If the Hotelling statistic T(1)(2) is greater than CL(1), where CL(1) > w, the control chart signals an out-of-control condition. If w < T(1)(2) <= CL(1), the sampling goes on to the second stage, where the remaining n(2) items of the sample are inspected and T(2)(2) for the mean vector of the whole sample is computed. During the second stage of the sampling, the control chart signals an out-of-control condition when the statistic T(2)(2) is larger than CL(2). A comparative study shows that the BDS chart detects process disturbances faster than the standard bivariate T(2) chart and the adaptive bivariate T(2) charts with variable sample size and/or variable sampling interval.
Resumo:
A standard (X) over bar chart for controlling the process mean takes samples of size no at specified, equally-spaced, fixed-time points. This article proposes a modification of the standard (X) over bar chart that allows one to take additional samples, bigger than no, between these fixed times. The additional samples are taken from the process when there is evidence that the process mean moved from target. Following the notation proposed by Reynolds (1996a) and Costs (1997) we shortly call the proposed (X) over bar chart as VSSIFT (X) over bar chart: where VSSIFT means variable sample size and sampling intervals with fixed times. The (X) over bar chart with the VSSIFT feature is easier to be administered than a standard VSSI (X) over bar chart that is not constrained to sample at the specified fixed times. The performances of the charts in detecting process mean shifts are comparable.
Resumo:
Recent theoretical studies have shown that the X̄ chart with variable sampling intervals (VSI) and the X̄ chart with variable sample size (VSS) are quicker than the traditional X̄ chart in detecting shifts in the process. This article considers the X̄ chart with variable sample size and sampling intervals (VSSI). It is assumed that the amount of time the process remains in control has exponential distribution. The properties of the VSSI X̄ chart are obtained using Markov chains. The VSSI X̄ chart is even quicker than the VSI or VSS X̄ charts in detecting moderate shifts in the process.
Resumo:
A standard X̄ chart for controlling the process mean takes samples of size n0 at specified, equally-spaced, fixed-time points. This article proposes a modification of the standard X chart that allows one to take additional samples, bigger than n0, between these fixed times. The additional samples are taken from the process when there is evidence that the process mean moved from target. Following the notation proposed by Reynolds (1996a) and Costa (1997) we shortly call the proposed X chart as VSSIFT X chart where VSSIFT means variable sample size and sampling intervals with fixed times. The X chart with the VSSIFT feature is easier to be administered than a standard VSSI X chart that is not constrained to sample at the specified fixed times. The performances of the charts in detecting process mean shifts are comparable. Copyright © 1998 by Marcel Dekker, Inc.