947 resultados para Interobserver Agreement
Resumo:
Background: We aimed to validate three widely used scales in stroke research in a multiethnic Brazilian population. Methods: The National Institutes of Health Stroke Scale (NIHSS), modified Rankin Scale (mRS) and Barthel Index (BI) were translated, culturally adapted and applied by two independent investigators. The mRS was applied with or without a previously validated structured interview. Interobserver agreement (kappa statistics) and intraclass correlation coefficients were calculated. Results: 84 patients underwent mRS (56 with and 28 without a structured interview), 57 BI and 62 NIHSS scoring. Intraclass correlation coefficient was 0.902 for NIHSS and 0.967 for BI. For BI, interobserver agreement was good (kappa = 0.70). For mRS, the structured interview improved interobserver agreement (kappa = 0.34 without a structured interview; 0.75 with a structured interview). Conclusion: The NIHSS, BI and mRS show good validity when translated and culturally adapted. Using a structured interview for the mRS improves interobserver concordance rates. Copyright (C) 2008 S. Karger AG, Basel
Resumo:
Background: Noninvasive diagnosis of giant cell arteritis (GCA) remains challenging, particularly with regard to evaluation of extracranial arterial disease. Objectives: The objective of the study was to retrospectively review extracranial involvement in patients with GCA and/or polymyalgia rheumatica (PMR), evaluated with magnetic resonance imaging (MRI), especially 3-dimensional contrast-enhanced magnetic resonance angiography images of the aortic arch and its branches. Methods: Clinical information, biopsy status, and MRI examinations of 28 patients with GCA/PMR were reviewed. Patient images were mixed randomly with 20 normal control images and were independently reviewed by 2 radiologists. Interobserver agreement for detection of arterial stenosis was determined by the k coefficient. Results: Both readers described vascular alterations in keeping with extracranial GCA in 19 of 28 patients (67%) with good interobserver agreement (k = 0.73) and with even higher agreement on diagnosing nonocclusive versus occlusive disease (k = 1.00). The most common lesions were bilateral axillary stenosis or obstructions, observed by both readers in 8 patients (28%). Among the 19 patients with magnetic resonance angiography lesions in the subclavian/axillary arteries, 12 (75%) had biopsy-proven GCA, but only 5 (41%) of these patients had clinical features of large artery disease. Conclusions: In our series review, MRI could provide accurate information on involvement of the aortic arch and its branches in extracranial GCA, depicting different degrees of stenosis. Our analysis also illustrates that occult large artery vasculitis should be considered in patients without biopsy-proven GCA, patients with classic GCA but without clinical signs of large artery disease, and in patients initially diagnosed as having PMR.
Resumo:
Para uma melhor avaliação e definição do plano de intervenção do indivíduo, é cada vez mais importante a existência instrumentos de avaliação válidos e fiáveis para a população portuguesa. Objetivo: Traduzir e adaptar para a população Portuguesa a escala Trunk Impairment Scale (TIS) em pacientes pós-AVE, e avaliar as propriedades psicométricas da mesma. Metodologia: A TIS foi traduzida para o Português e adaptada culturalmente para a população portuguesa. As propriedades psicométricas da mesma, incluindo validade, fiabilidade, concordância inter-observadores, consistência interna, sensibilidade, especificidade, poder de resposta, foram avaliadas numa população diagnosticada com AVE e num grupo de controlo de participantes saudáveis. Participaram neste estudo 80 indivíduos, divididos em dois grupos, nomeadamente indivíduos pós-AVE (40) e um grupo sem patologia (40). Os participantes foram submetidos à aplicação das escalas de Berg, Medida de Independência Funcional e Escala de Desempenho Físico Fugl Meyer e a TIS de modo a avaliar as propriedades psicométricas desta. As avaliações foram realizadas por duas fisioterapeutas experientes e o re-teste foi realizado após 48 horas. Os dados foram registados e trabalhados com o programa informático SPSS 21.0. Resultados: Relativamente aos valores obtidos, verificou-se que, quanto à consistência interna da TIS estes apresentam-se de forma moderada a elevada (alfa Cronbach = 0,909). Quanto à fiabilidade inter-observadores, os itens com menor valor são os itens 1 e 4 (0,759 e 0,527, respetivamente) e os itens com valor de Kappa mais alto são os itens 5 e 6 (0,830 e 0,893, respetivamente). Relativamente à validade de critério, verificou-se que não houve correlação entre a escala de Desempenho Físico Fugl-Meyer, a escala de Equilibrio de Berg e a Medida de Independência Funcional, ou seja, os valores obtidos r=0,166; r=0,017; r= -0,002, respetivamente. Quanto à validade de construção, constatou-se que o valor da mediana é mais elevado nos itens 1 a 5, logo sugere que haja diferenças entre o grupo de indivíduos pós-AVE e o grupo de indivíduos saudáveis (p<0,001). Entre os outros dois itens (6 e 7) não foram encontradas diferenças nas respostas nos dois grupos, sendo o valor de p > 0,001. Conclusão: Os resultados obtidos neste estudo sugerem que a versão portuguesa da TIS apresenta bons níveis de fiabilidade, consistência interna e também apresenta bons resultados no que refere à concordância inter-observadores.
Resumo:
Tese de Doutoramento em Medicina
Resumo:
OBJECTIVE: Evaluation of inter and intraobserver reproducibility of by the visual method interpretation of cineangiogram in a clinically based context. METHODS: Five interventional cardiologists analyzed 11 segments of 8 coronary cineangiograms at a two month apart sessions. The percent luminal reduction by the lesions were analyzed by two different classifications: in one (A) the lesions were graded in 0% = absent, 1-50% = mild, 51 - 69 = moderate, and > or = 70% = severe; the other classification (B) was a dichotomic one : <70% = nonsignificant and > or = 70%=significant lesions. The agreement were measured by the kappa (k) index. RESULTS: Interobserver agreement was moderate for classification A (1st measurement, k = 0.36 -- 0.63, k m = 0.49; 2nd measurement, k = 0.39-0.68, k m = 0.52) and good for classification B (1st measurement, k = 0.55-0.73, k m = 0.63; 2nd measurement, k = 0.37-0.82, k m = 0.61). Intraobserver levels of agreement were k = 0.57-0.95 for classification A and 0.62-1.0 for classification B. CONCLUSION: The higher level of reproducibility obtained by adopting the dichotomous criteria usually considered for ischemic limits demonstrates that in the present clinical context, the reliability of the simple visual method is adequate for the identification of patients with clinically significant lesions and candidates for myocardial revascularization procedures.
Resumo:
BACKGROUND: The aim of this study was to assess, at the European level and using digital technology, the inter-pathologist reproducibility of the ISHLT 2004 system and to compare it with the 1990 system We also assessed the reproducibility of the morphologic criteria for diagnosis of antibody-mediated rejection detailed in the 2004 grading system. METHODS: The hematoxylin-eosin-stained sections of 20 sets of endomyocardial biopsies were pre-selected and graded by two pathologists (A.A. and M.B.) and digitized using a telepathology digital pathology system (Aperio ImageScope System; for details refer to http://aperio.com/). Their diagnoses were considered the index diagnoses, which covered all grades of acute cellular rejection (ACR), early ischemic lesions, Quilty lesions, late ischemic lesions and (in the 2005 system) antibody-mediated rejection (AMR). Eighteen pathologists from 16 heart transplant centers in 7 European countries participated in the study. Inter-observer reproducibility was assessed using Fleiss's kappa and Krippendorff's alpha statistics. RESULTS: The combined kappa value of all grades diagnosed by all 18 pathologists was 0.31 for the 1990 grading system and 0.39 for the 2005 grading system, with alpha statistics at 0.57 and 0.55, respectively. Kappa values by grade for 1990/2005, respectively, were: 0 = 0.52/0.51; 1A/1R = 0.24/0.36; 1B = 0.15; 2 = 0.13; 3A/2R = 0.29/0.29; 3B/3R = 0.13/0.23; and 4 = 0.18. For the 2 cases of AMR, 6 of 18 pathologists correctly suspected AMR on the hematoxylin-eosin slides, whereas, in each of 17 of the 18 AMR-negative cases a small percentage of pathologists (range 5% to 33%) overinterpreted the findings as suggestive for AMR. CONCLUSIONS: Reproducibility studies of cardiac biopsies by pathologists in different centers at the international level were feasible using digitized slides rather than conventional histology glass slides. There was a small improvement in interobserver agreement between pathologists of different European centers when moving from the 1990 ISHLT classification to the "new" 2005 ISHLT classification. Morphologic suspicion of AMR in the 2004 system on hematoxylin-eosin-stained slides only was poor, highlighting the need for better standardization of morphologic criteria for AMR. Ongoing educational programs are needed to ensure standardization of diagnosis of both acute cellular and antibody-mediated rejection.
Resumo:
We performed a pilot study to compare vertebral fracture assessments (VFA) and lateral X-rays in terms of inter- and intraobserver reliability and degree of correlation for the detection of syndesmophytes in ankylosing spondylitis (AS). We recruited 19 patients with AS and recent lumbar or cervical lateral X-rays with at least one syndesmophyte. Each patient underwent dual-energy X-ray absorptiometry with measurement of bone mineral density and dorso-lumbar VFA. Intra- and interreader reliability for VFA and X-rays were measured using 2 independent, blinded observers and Cohen's kappa values. An adapted modified Stoke Ankylosing Spondylitis Spinal Score (amSASSS) was generated with each method, and these 2 values correlated. For X-rays, intraobserver and interobserver agreement were 94.3% (κ = 0.83) and 98.6% (κ = 0.96), respectively; for VFA, corresponding values were 92.8% (κ = 0.79) and 93.8% (κ = 0.82). Overall agreement between the 2 techniques was 88.6% (κ = 0.72). The Pearson correlation coefficient for the 2 methods was 0.95 for the modified Stoke Ankylosing Spondylitis Spinal Score . Per dual-energy X-ray absorptiometry-generated bone mineral density, >50% of patients were osteopenic and 10% osteoporotic. In terms of reproducibility and correlation with X-rays, performing a VFA appears to be a candidate for assessing radiographic damage in AS, thought further research is necessary to justify this indication.
Compressed Sensing Single-Breath-Hold CMR for Fast Quantification of LV Function, Volumes, and Mass.
Resumo:
OBJECTIVES: The purpose of this study was to compare a novel compressed sensing (CS)-based single-breath-hold multislice magnetic resonance cine technique with the standard multi-breath-hold technique for the assessment of left ventricular (LV) volumes and function. BACKGROUND: Cardiac magnetic resonance is generally accepted as the gold standard for LV volume and function assessment. LV function is 1 of the most important cardiac parameters for diagnosis and the monitoring of treatment effects. Recently, CS techniques have emerged as a means to accelerate data acquisition. METHODS: The prototype CS cine sequence acquires 3 long-axis and 4 short-axis cine loops in 1 single breath-hold (temporal/spatial resolution: 30 ms/1.5 × 1.5 mm(2); acceleration factor 11.0) to measure left ventricular ejection fraction (LVEFCS) as well as LV volumes and LV mass using LV model-based 4D software. For comparison, a conventional stack of multi-breath-hold cine images was acquired (temporal/spatial resolution 40 ms/1.2 × 1.6 mm(2)). As a reference for the left ventricular stroke volume (LVSV), aortic flow was measured by phase-contrast acquisition. RESULTS: In 94% of the 33 participants (12 volunteers: mean age 33 ± 7 years; 21 patients: mean age 63 ± 13 years with different LV pathologies), the image quality of the CS acquisitions was excellent. LVEFCS and LVEFstandard were similar (48.5 ± 15.9% vs. 49.8 ± 15.8%; p = 0.11; r = 0.96; slope 0.97; p < 0.00001). Agreement of LVSVCS with aortic flow was superior to that of LVSVstandard (overestimation vs. aortic flow: 5.6 ± 6.5 ml vs. 16.2 ± 11.7 ml, respectively; p = 0.012) with less variability (r = 0.91; p < 0.00001 for the CS technique vs. r = 0.71; p < 0.01 for the standard technique). The intraobserver and interobserver agreement for all CS parameters was good (slopes 0.93 to 1.06; r = 0.90 to 0.99). CONCLUSIONS: The results demonstrated the feasibility of applying the CS strategy to evaluate LV function and volumes with high accuracy in patients. The single-breath-hold CS strategy has the potential to replace the multi-breath-hold standard cardiac magnetic resonance technique.
Resumo:
Purpose: To evaluate the diagnostic value and image quality of CT with filtered back projection (FBP) compared with adaptive statistical iterative reconstructed images (ASIR) in body stuffers with ingested cocaine-filled packets.Methods and Materials: Twenty-nine body stuffers (mean age 31.9 years, 3 women) suspected for ingestion of cocaine-filled packets underwent routine-dose 64-row multidetector CT with FBP (120kV, pitch 1.375, 100-300 mA and automatic tube current modulation (auto mA), rotation time 0.7sec, collimation 2.5mm), secondarily reconstructed with 30 % and 60 % ASIR. In 13 (44.83%) out of the body stuffers cocaine-filled packets were detected, confirmed by exact analysis of the faecal content including verification of the number (range 1-25). Three radiologists independently and blindly evaluated anonymous CT examinations (29 FBP-CT and 68 ASIR-CT) for the presence and number of cocaine-filled packets indicating observers' confidence, and graded them for diagnostic quality, image noise, and sharpness. Sensitivity, specificity, area under the receiver operating curve (ROC) Az and interobserver agreement between the 3 radiologists for FBP-CT and ASIR-CT were calculated.Results: The increase of the percentage of ASIR significantly diminished the objective image noise (p<0.001). Overall sensitivity and specificity for the detection of the cocaine-filled packets were 87.72% and 76.15%, respectively. The difference of ROC area Az between the different reconstruction techniques was significant (p= 0.0101), that is 0.938 for FBP-CT, 0.916 for 30 % ASIR-CT, and 0.894 for 60 % ASIR-CT.Conclusion: Despite the evident image noise reduction obtained by ASIR, the diagnostic value for detecting cocaine-filled packets decreases, depending on the applied ASIR percentage.
Resumo:
PURPOSE: To evaluate the diagnostic value of previously described MR features used for detecting suspected placental invasion according to observers' experience. MATERIALS AND METHODS: Our population included 25 pregnant women (mean age 35.16) investigated by prenatal MRI (1.5T, T1- and T2-weighted MR-sequences without i.v. contrast), among them 12 with histopathologically proven placental invasion and 13 women (52%) without placental invasion used as control group. Two senior and two junior radiologists blindly and independently reviewed MR-examinations in view of 6 previously defined MR-features indicating presence and degree of placental invasion (placenta increta, accreta or percreta). For each reader the sensibility, specificity, and receiver operating curve (ROC) were calculated. Interobserver agreements between senior and junior readers were determined. Stepwise logistic regression was performed including the 6 MR-features predictive of placental invasion. RESULTS: Demographics between both groups were statistically equivalent. Overall sensitivity and specificity for placental invasion was 90.9% and 75.0% for seniors and 81.8% and 61.8% for juniors, respectively. The best single MR-feature indicating placental invasion was T2-hypointense placental bands (r(2)=0.28), followed by focally interrupted myometrial border, infiltration of pelvic organs and tenting of the bladder (r(2)=0.36). Interobserver agreement for detecting placental invasion was 0.64 for seniors and 0.41 for juniors, thus substantial and moderate, respectively. Seniors detected placental invasion and depth of infiltration with significantly higher diagnostic certitude than juniors (p=0.0002 and p=0.0282, respectively). CONCLUSION: MRI can be a reliable and reproducible tool for the detection of suspected placental invasion, but the diagnostic value significantly depends on observers' experience.
Resumo:
INTRODUCTION: Lumbar spinal stenosis (LSS) treatment is based primarily on the clinical criteria providing that imaging confirms radiological stenosis. The radiological measurement more commonly used is the dural sac cross-sectional area (DSCA). It has been recently shown that grading stenosis based on the morphology of the dural sac as seen on axial T2 MRI images, better reflects severity of stenosis than DSCA and is of prognostic value. This radiological prospective study investigates the variability of surface measurements and morphological grading of stenosis for varying degrees of angulation of the T2 axial images relative to the disc space as observed in clinical practice. MATERIALS AND METHODS: Lumbar spine TSE T2 three-dimensional (3D) MRI sequences were obtained from 32 consecutive patients presenting with either suspected spinal stenosis or low back pain. Axial reconstructions using the OsiriX software at 0°, 10°, 20° and 30° relative to the disc space orientation were obtained for a total of 97 levels. For each level, DSCA was digitally measured and stenosis was graded according to the 4-point (A-D) morphological grading by two observers. RESULTS: A good interobserver agreement was found in grade evaluation of stenosis (k = 0.71). DSCA varied significantly as the slice orientation increased from 0° to +10°, +20° and +30° at each level examined (P < 0.0001) (-15 to +32% at 10°, -24 to +143% at 20° and -29 to +231% at 30° of slice orientation). Stenosis definition based on the surface measurements changed in 39 out of the 97 levels studied, whereas the morphology grade was modified only in two levels (P < 0.01). DISCUSSION: The need to obtain continuous slices using the classical 2D MRI acquisition technique entails often at least a 10° slice inclination relative to one of the studied discs. Even at this low angulation, we found a significantly statistical difference between surface changes and morphological grading change. In clinical practice, given the above findings, it might therefore not be necessary to align the axial cuts to each individual disc level which could be more time-consuming than obtaining a single series of axial cuts perpendicular to the middle of the lumbar spine or to the most stenotic level. In conclusion, morphological grading seems to offer an alternative means of assessing severity of spinal stenosis that is little affected by image acquisition technique.
Resumo:
Purpose: To compare entero-MDCT with entero-MRI performed for suspicion of acute exacerbation of known Crohn's disease. Methods and Materials: Fifty-seven patients (mean age 33.5) with histologically proven Crohn's disease were prospectively included. They presented with clinical symptoms suggesting acute exacerbation to the emergency department. After oral administration of 1-2 l of 5% methylcellulosis (+syrup), entero-MDCT and entero- MRI were performed on each patient (mean delay 1 day). Three experienced radiologists blindly and independently evaluated each examination for technical quality, eight pathological CT features (bowel wall thickening, pathological wall enhancement, stenosis, lymphadenopathy, mesenteric haziness, intraperitoneal fluid, abscess, fistula) and final main diagnosis. Interobserver agreement kappa was calculated. Sensitivity and specificity resulted from comparison with the reference standard, consisting of operation (n= 30) and long-time follow-up in case of conservative treatment (n=27). Results: Entero-MDCT demonstrated considerably less artefacts than entero-MRI (p 0.0001). In 9 entero-MDCT/-MRI, no activity of Crohn's disease was seen, whereas in 48 entero-MDCT/-MRI active disease could be demonstrated, such as intraperitoneal abscesses (n=11), fistulas (n=13), stenoses (n=23), acute (n=15) or chronic (n=23) inflammation. Interobserver agreement of the three readers was not significantly different between entero-MDCT and -MRI, neither was sensitivity (range 60-89%) and specificity (range 75-100%) for each of the eight pathological features or for the main diagnosis. Conclusion: Entero-MRI is statistically of similar diagnostic value as entero-MDCT for acute complications of Crohn's disease. Therefore, entero-IRM, devoid of harmful irradiation, should become the preferred imaging modality, since we deal with young patients, very likely exposed to frequent imaging controls in the future.
Resumo:
Purpose: To evaluate whether parametric imaging with contrast material-enhanced ultrasonography (US) is superior to visual assessment for the differential diagnosis of focal liver lesions (FLLs). Materials and Methods: This study had institutional review board approval, and verbal patient informed consent was obtained. Between August 2005 and October 2008, 146 FLLs in 145 patients (63 women, 82 men; mean age, 62.5 years; age range, 22-89 years) were imaged with real-time low-mechanical-index contrast-enhanced US after a bolus injection of 2.4 mL of a second-generation contrast agent. Clips showing contrast agent uptake kinetics (including arterial, portal, and late phases) were recorded and subsequently analyzed off-line with dedicated image processing software. Analysis of the dynamic vascular patterns (DVPs) of lesions with respect to adjacent parenchyma allowed mapping DVP signatures on a single parametric image. Cine loops of contrast-enhanced US and results from parametric imaging of DVP were assessed separately by three independent off-site readers who classified each lesion as benign, malignant, or indeterminate. Sensitivity, specificity, accuracy, and positive and negative predictive values were calculated for both techniques. Interobserver agreement (κ statistics) was determined. Results: Sensitivities for visual interpretation of cine loops for the three readers were 85.0%, 77.9%, and 87.6%, which improved significantly to 96.5%, 97.3%, and 96.5% for parametric imaging, respectively (P < .05, McNemar test), while retaining high specificity (90.9% for all three readers). Accuracy scores of parametric imaging were higher than those of conventional contrast-enhanced US for all three readers (P < .001, McNemar test). Interobserver agreement increased with DVP parametric imaging compared with conventional contrast-enhanced US (change of κ from 0.54 to 0.99). Conclusion: Parametric imaging of DVP improves diagnostic performance of contrast-enhanced US in the differentiation between malignant and benign FLLs; it also provides excellent interobserver agreement.
Resumo:
Purpose: To evaluate the diagnostic value of specific MR features for detection of suspected placental invasion according to observers' experience.Methods and Materials: Our study population included 25 pregnant women (mean age 35.16) investigated by prenatal MRI. In twelve out of them placental invasion was histopathologically proven, the 13 other women (52%) without placental invasion served as control group. Multiplanar T1- and T2-weighted sequences had been performed mostly without IV contrast injection (1.5 T). MR examinations of the two groups were rendered anonymous, mixed, then independently and retrospectively reviewed by two senior and two junior radiologists in view of 8 MR features indicating placentar invasion including the degree. Results were compared with surgical diagnosis (placenta normal/increta/accreta/percreta). Interobserver agrement between senior and junior readers were calculated. Stepwise logistic regression and receiver operating (ROC) curvers were performed.Results: Demographics between the two groups were not statistically different. Overall sensitivity and specificity for detecting placentar invasion was 90.9% and 75.0% for senior readers, and 81.8% and 61.8% for junior readers respectively. The most significant MR features indicating placentar invasion were T2 hypointense placental bands, followed by placenta praevia, focally interrupted myometrial border, posterior placental insertion, and heterogeneous placental signal. For each of the evaluated MR features the interobserver agreement kappa between the two senior readers was superior than that between the junior readers, ranging from bad (<0.4) to good (0.4-0.75).Conclusions: MRI can be a reliable and reproducible tool for detection of suspected placentar invasion, however very variable according to the observers' experience.
Resumo:
PURPOSE: To develop and assess the diagnostic performance of a three-dimensional (3D) whole-body T1-weighted magnetic resonance (MR) imaging pulse sequence at 3.0 T for bone and node staging in patients with prostate cancer. MATERIALS AND METHODS This prospective study was approved by the institutional ethics committee; informed consent was obtained from all patients. Thirty patients with prostate cancer at high risk for metastases underwent whole-body 3D T1-weighted imaging in addition to the routine MR imaging protocol for node and/or bone metastasis screening, which included coronal two-dimensional (2D) whole-body T1-weighted MR imaging, sagittal proton-density fat-saturated (PDFS) imaging of the spine, and whole-body diffusion-weighted MR imaging. Two observers read the 2D and 3D images separately in a blinded manner for bone and node screening. Images were read in random order. The consensus review of MR images and the findings at prospective clinical and MR imaging follow-up at 6 months were used as the standard of reference. The interobserver agreement and diagnostic performance of each sequence were assessed on per-patient and per-lesion bases. RESULTS: The signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) were significantly higher with whole-body 3D T1-weighted imaging than with whole-body 2D T1-weighted imaging regardless of the reference region (bone or fat) and lesion location (bone or node) (P < .003 for all). For node metastasis, diagnostic performance (area under the receiver operating characteristic curve) was higher for whole-body 3D T1-weighted imaging (per-patient analysis; observer 1: P < .001 for 2D T1-weighted imaging vs 3D T1-weighted imaging, P = .006 for 2D T1-weighted imaging + PDFS imaging vs 3D T1-weighted imaging; observer 2: P = .006 for 2D T1-weighted imaging vs 3D T1-weighted imaging, P = .006 for 2D T1-weighted imaging + PDFS imaging vs 3D T1-weighted imaging), as was sensitivity (per-lesion analysis; observer 1: P < .001 for 2D T1-weighted imaging vs 3D T1-weighted imaging, P < .001 for 2D T1-weighted imaging + PDFS imaging vs 3D T1-weighted imaging; observer 2: P < .001 for 2D T1-weighted imaging vs 3D T1-weighted imaging, P < .001 for 2D T1-weighted imaging + PDFS imaging vs 3D T1-weighted imaging). CONCLUSION: Whole-body MR imaging is feasible with a 3D T1-weighted sequence and provides better SNR and CNR compared with 2D sequences, with a diagnostic performance that is as good or better for the detection of bone metastases and better for the detection of lymph node metastases.