952 resultados para Instantaneous angular speed analysis
Resumo:
Data variability analysis has been the focus of a number of studies seeking to capture differences of patterns generated by biological systems. Although several studies related to gait employ the analysis of variability in their observations, we noticed a lack of such information for subjects with unilateral coxarthrosis undergoing total hip arthroplasty (THA). To tackle this deficiency of information, we conducted a study of the gait on a treadmill with10 healthy subjects (30.7 ± 6.75 years old) from G1 and 24 subjects (65 ± 8.5 years old) with unilateral THA from G2. Thus, by means of two inertial measurement units (IMUs) positioned in the pelvis, we have developed a detection method of the step and stride for calculating these intervals and extract the signal characteristics. The variability analysis (coefficient of variation) was performed, taking into consideration the extracted features and the step and stride times. The average and the 95% confidence interval estimate for the average of the step and stride times to each group were in agreement with literature. The mean coefficient of variation for the step and stride times was calculated and compared among groups by the Kruskal-Wallis test with 95% confidence interval. Each component X, Y and Z of the two IMUs (accelerometer, magnetometer and gyroscope) corresponded to a variable. The resultants of each sensor, the linear velocity (accelerometers) and the instantaneous angular displacement (gyroscopes) completed the set of variables. The characteristics were extracted from the signals of these variables to check the variability in the G1 and G2 groups . There were significant differences (p <0.05) between G1 and G2 for the average of the step and stride times. The variability of the step and stride, as well as the variability of all other evaluated characteristics were higher for the group G2 (p <0.05). The method proposed in this study proved to be suitable for the measuring of variability of biomechanical parameters related to the extracted features. All the extracted features categorized the groups. The G2 group showed greater variability, so it is possible that the age and the pathological condition of the hip both contributed to this result.
Resumo:
Dissertação (mestrado)—Universidade de Brasília, Faculdade de Educação Física, Programa de Pós-Graduação Strictu-Sensu em Educação Física, 2015.
Resumo:
This thesis investigates the rotational behavior of abstracted small-wind-turbine rotors exposed to a sudden increase in oncoming flow velocity, i.e. a gust. These rotors consisted of blades with aspect ratios characteristic of samara seeds, which are known for their ability to maintain autorotation in unsteady wind. The models were tested in a towing tank using a custom-built experimental rig. The setup was designed and constructed to allow for the measurement of instantaneous angular velocity of a rotor model towed at a prescribed kinematic profile along the tank. The conclusions presented in this thesis are based on the observed trends in effective angle-of-attack distribution, tip speed ratio, angular velocity, and time delay in the rotational response for each of rotors over prescribed gust cases. It was found that the blades with the higher aspect ratio had higher tip speed ratios and responded faster than the blades with a lower aspect ratio. The decrease in instantaneous tip speed ratio during the onset of a prescribed gust correlated with the time delay in each rotor model's rotational response. The time delays were found to increase nonlinearly with decreasing durations over which the simulated gusts occurred.
Resumo:
Generally, quadriplegic individuals have difficulties performing object manipulation. Toward satisfactory manipulation, reach and grasp movements must be performed with voluntary control, and for that, grasp force feedback is essential. A hybrid system aiming at partial upper limb sensory-motor restoration for quadriplegics was built. Such device is composed of an elbow dynamic orthosis that provides elbow flexion/extension (range was approximately from 20 degrees to 120 degrees, and average angular speed was approximately 15 degrees/s) with forearm support, a wrist static orthosis and neuromuscular electrical stimulation for grasping generation, and a glove with force sensors that allows grasping force feedback. The glove presents two user interface modes: visual by light emitting diodes or audio emitted by buzzer. Voice control of the entire system (elbow dynamic orthosis and electrical stimulator) is performed by the patient. The movements provided by the hybrid system, combined with the scapular and shoulder movements performed by the patient, can aid quadriplegic individuals in tasks that involve reach and grasp movements.
Resumo:
Sodium diclofenac (SD) release from dosage forms has been studied under different conditions. However, no dissolution method that is discriminatory enough to reflect slight changes in formulation or manufacturing process, and which could be effectively correlated with the biological properties of the dosage form, has been reported. This study sought to develop three different formulae of SD-containing matrix tablets and to determine the effect of agitation speed in its dissolution profiles. F1, F2 and F3 formulations were developed using hypromellose (10, 20 and 30%, respectively for F1, F2 and F3) and other conventional excipients. Dissolution tests were carried out in phosphate buffer pH 6.8 at 37 degrees C using apparatus 11 at 50, 75 or 100 rpm. Dissolution efficiency (DE), T(50) and T(90) were determined and plotted as functions of the variables agitation speed and hypromellose concentration. Regarding DE, F2 showed more sensitivity to variations in agitation speed than F1 and F3. Increasing hypromellose concentration reduced DE values, independent of agitation speed. Analysis of T(50) and T(90) suggests that F1 is less sensitive to variations in agitation speed than F2 and F3. Most discriminatory dissolution conditions were observed at 50 rpm. Results suggest that the comparison of dissolution performance of SD matrix tablets should take into account polymer concentration and agitation conditions. (C) 2009 Published by Elsevier B.V.
Resumo:
Työn tarkoituksena oli hakea mittausjärjestelmän raja-arvoja optiselle kamerapohjaiselle roskalaskentajärjestelmälle sekä testata roskalaskentajärjestelmän toimivuus käytännössä. Tavoitteena oli tuotteistaa kamerapohjainen roskalaskenta-analyysi palvelutuotteeksi, jota voitaisiin hyödyntää sihtien kuntokartoituksessa ja ongelmanratkaisuvälineenä. Teoriaosa koostui kahdesta kokonaisuudesta: sulpun epäpuhtauksista, roskalaskennan teoriasta ja epäpuhtauksien mittausmenetelmistä sekä markkinoinnista, tuotteistamis- ja lanseerausprosessista palvelutuotteen näkökulmasta. Kokeellisessa osassa selvitettiin kamerapohjaiseen roskalaskentaanalyysiin vaikuttavia tekijöitä: kameran tarkennus, kuvan terävyys, analysoitavan arkin väri, neliömassa ja roskapitoisuus, impregnointi, valonlähde, kuvan muokkaus, tiedostomuoto ja pikselimäärä. Kamerapohjaisen roskalaskenta-analyysin soveltuvuus käytäntöön testattiin tehdasesimerkin avulla. Havaittiin, että kamerapohjaista roskalaskenta-analyysiä voitaisiin käyttää lähes kaikille massatyypeille. Työssä määriteltiin kalibrointimenetelmä kameran tarkentamiseksi arkin tasoon sekä suljinnopeusanalyysi massatyypistä riippuvan suljinnopeuden selvitykseen. Kamerapohjaisessa roskalaskenta-analyysissä määritettiin käytettäväksi arkin neliömassana 60 g/m2, suljinaukkoa F5 ja terävyysasetusta 5. Tulokseksi saatiin, että analysoitavia arkkeja ei tarvitse impregnoida tai jälkikäsitellä. Korrelaatiota Somerville-erotustehokkuuteen ei löytynyt. Esimerkkitehtaasta selvitettiin primääriportaan roskapitoisuudet ja erotustehokkuudet. Tehdasesimerkin tulosten perusteella havaittiin happivaiheen ja D0-vaiheen olleen tehokkaimpia epäpuhtauksien poistajia.
Resumo:
The objective of this study was to model mathematically and to simulate the dynamic behavior of an auger-type fertilizer applicator (AFA) in order to use the variable-rate application (VRA) and reduce the coefficient of variation (CV) of the application, proposing an angular speed controller θ' for the motor drive shaft. The input model was θ' and the response was the fertilizer mass flow, due to the construction, density of fertilizer, fill factor and the end position of the auger. The model was used to simulate a control system in open loop, with an electric drive for AFA using an armature voltage (V A) controller. By introducing a sinusoidal excitation signal in V A with amplitude and delay phase optimized and varying θ' during an operation cycle, it is obtained a reduction of 29.8% in the CV (constant V A) to 11.4%. The development of the mathematical model was a first step towards the introduction of electric drive systems and closed loop control for the implementation of AFA with low CV in VRA.
Resumo:
Falls are a major concern in the elderly population with chronic joint disease. To compare muscular function and functional mobility among older women with knee osteoarthritis with and without a history of falls, 15 elderly women with a history of falls (74.20 ± 4.46 years) and 15 without a history of falls (71.73 ± 4.73 years) were studied. Muscular function, at the angular speed of 60, 120, and 180º/s, was evaluated using the Biodex Isokinetic Dynamometer. The sit-to-stand task was performed using the Balance Master System and the Timed Up and Go test was used to determine functional mobility. After collection of these data, the history of falls was investigated. A statistically significant difference was detected in the time taken to transfer the center of gravity during the sit-to-stand test (means ± SD; non-fallers: 0.35 ± 0.16 s; fallers: 0.55 ± 0.32 s; P = 0.049, Student t-test) and in the Timed Up and Go test (medians; non-fallers: 10.08 s; fallers: 11.59 s; P = 0.038, Mann-Whitney U-test). The results indicated that elderly osteoarthritic women with a history of falls presented altered functional mobility and needed more time to transfer the center of gravity in the sit-to-stand test. It is important to implement strategies to guarantee a better functional performance of elderly patients to reduce fall risks.
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
O objetivo deste estudo foi comparar a taxa de desenvolvimento de força (TDF) nas contrações isométrica e isocinética concêntrica a 60°.s-1 e 180°.s-1. Quatorze indivíduos do gênero masculino (idade = 23,1 ± 2,8 anos; estatura = 174 ± 31,3cm; massa corporal = 81 ± 12kg) realizaram inicialmente uma familiarização ao equipamento isocinético. Posteriormente, os indivíduos realizaram em ordem randômica cinco contrações isocinéticas máximas para os extensores do joelho a 60°.s-1 e 180°.s-1 para determinar o torque máximo concêntrico (TMC) e duas contrações isométricas máximas de 3s para determinar o torque máximo isométrico (TMI). O TMI (301,4 ± 56,0N.m) foi maior do que o TMC a 60°.s-1 (239,8 ± 42,2N.m) e 180°.s-1 (175,0 ± 32,5 N.m). O TMC a 60°.s-1 foi maior do que o TMC a 180°.s-1. Para os intervalos de 0-30ms e 0-50ms, a TDF na condição isométrica (1.196,6 ± 464,6 e 1.326,5 ± 514,2N.m.s-1, respectivamente) foi similar à TDF a 60°.s-1 (1.035,4 ± 446,2 e 1.134,3 ± 448,4N.m.s-1) e maior do que a 180°.s-1 (656,7 ± 246,6 e 475,2 ± 197,9N.m.s-1), sendo ainda que a TDF na contração concêntrica a 180°.s-1 foi menor do que a 60°.s-1. No intervalo de 0-100ms, a TDF da contração isométrica (1.248,8 ± 417,4N.m.s-1) foi maior que a obtida na contração isocinética rápida (909,2 ± 283,4N.m.s-1). A TDF obtida na contração isocinética lenta (1.005,4 ± 247,7N.m.s-1) foi similar à obtida na contração isométrica e na concêntrica isocinética rápida. No intervalo 0-150ms, a TDF isométrica (1.084,2 ± 332,1N.m.s-1) foi maior do que as concêntricas (60°.s-1 e 180°.s-1) (834,8 ± 184,2 e 767,6 ± 201,8N.m.s-1, respectivamente), não existindo diferenças entre estas duas últimas. Conclui-se que a TDF é dependente do tipo e da velocidade de contração, suportando a hipótese de que maiores velocidades de contração acarretam maior inibição do drive neural no início do movimento.
Resumo:
A current trend in the agricultural area is the development of mobile robots and autonomous vehicles for precision agriculture (PA). One of the major challenges in the design of these robots is the development of the electronic architecture for the control of the devices. In a joint project among research institutions and a private company in Brazil a multifunctional robotic platform for information acquisition in PA is being designed. This platform has as main characteristics four-wheel propulsion and independent steering, adjustable width, span of 1,80m in height, diesel engine, hydraulic system, and a CAN-based networked control system (NCS). This paper presents a NCS solution for the platform guidance by the four-wheel hydraulic steering distributed control. The control strategy, centered on the robot manipulators control theory, is based on the difference between the desired and actual position and considering the angular speed of the wheels. The results demonstrate that the NCS was simple and efficient, providing suitable steering performance for the platform guidance. Even though the simplicity of the NCS solution developed, it also overcame some verified control challenges in the robot guidance system design such as the hydraulic system delay, nonlinearities in the steering actuators, and inertia in the steering system due the friction of different terrains. Copyright © 2012 Eduardo Pacincia Godoy et al.
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Pós-graduação em Física - IGCE
Resumo:
This document is a summary of the Bachelor thesis titled “VHDL-Based System Design of a Cognitive Sensorimotor Loop (CSL) for Haptic Human-Machine Interaction (HMI)” written by Pablo de Miguel Morales, Electronics Engineering student at the Universidad Politécnica de Madrid (UPM Madrid, Spain) during an Erasmus+ Exchange Program at the Beuth Hochschule für Technik (BHT Berlin, Germany). The tutor of this project is Dr. Prof. Hild. This project has been developed inside the Neurobotics Research Laboratory (NRL) in close collaboration with Benjamin Panreck, a member of the NRL, and another exchange student from the UPM Pablo Gabriel Lezcano. For a deeper comprehension of the content of the thesis, a deeper look in the document is needed as well as the viewing of the videos and the VHDL design. In the growing field of automation, a large amount of workforce is dedicated to improve, adapt and design motor controllers for a wide variety of applications. In the specific field of robotics or other machinery designed to interact with humans or their environment, new needs and technological solutions are often being discovered due to the existing, relatively unexplored new scenario it is. The project consisted of three main parts: Two VHDL-based systems and one short experiment on the haptic perception. Both VHDL systems are based on a Cognitive Sensorimotor Loop (CSL) which is a control loop designed by the NRL and mainly developed by Dr. Prof. Hild. The CSL is a control loop whose main characteristic is the fact that it does not use any external sensor to measure the speed or position of the motor but the motor itself. The motor always generates a voltage that is proportional to its angular speed so it does not need calibration. This method is energy efficient and simplifies control loops in complex systems. The first system, named CSL Stay In Touch (SIT), consists in a one DC motor system controller by a FPGA Board (Zynq ZYBO 7000) whose aim is to keep contact with any external object that touches its Sensing Platform in both directions. Apart from the main behavior, three features (Search Mode, Inertia Mode and Return Mode) have been designed to enhance the haptic interaction experience. Additionally, a VGA-Screen is also controlled by the FPGA Board for the monitoring of the whole system. This system has been completely developed, tested and improved; analyzing its timing and consumption properties. The second system, named CSL Fingerlike Mechanism (FM), consists in a fingerlike mechanical system controlled by two DC motors (Each controlling one part of the finger). The behavior is similar to the first system but in a more complex structure. This system was optional and not part of the original objectives of the thesis and it could not be properly finished and tested due to the lack of time. The haptic perception experiment was an experiment conducted to have an insight into the complexity of human haptic perception in order to implement this knowledge into technological applications. The experiment consisted in testing the capability of the subjects to recognize different objects and shapes while being blindfolded and with their ears covered. Two groups were done, one had full haptic perception while the other had to explore the environment with a plastic piece attached to their finger to create a haptic handicap. The conclusion of the thesis was that a haptic system based only on a CSL-based system is not enough to retrieve valuable information from the environment and that other sensors are needed (temperature, pressure, etc.) but that a CSL-based system is very useful to control the force applied by the system to interact with haptic sensible surfaces such as skin or tactile screens. RESUMEN. Este documento es un resumen del proyecto fin de grado titulado “VHDL-Based System Design of a Cognitive Sensorimotor Loop (CSL) for Haptic Human-Machine Interaction (HMI)” escrito por Pablo de Miguel, estudiante de Ingeniería Electrónica de Comunicaciones en la Universidad Politécnica de Madrid (UPM Madrid, España) durante un programa de intercambio Erasmus+ en la Beuth Hochschule für Technik (BHT Berlin, Alemania). El tutor de este proyecto ha sido Dr. Prof. Hild. Este proyecto se ha desarrollado dentro del Neurorobotics Research Laboratory (NRL) en estrecha colaboración con Benjamin Panreck (un miembro del NRL) y con Pablo Lezcano (Otro estudiante de intercambio de la UPM). Para una comprensión completa del trabajo es necesaria una lectura detenida de todo el documento y el visionado de los videos y análisis del diseño VHDL incluidos en el CD adjunto. En el creciente sector de la automatización, una gran cantidad de esfuerzo está dedicada a mejorar, adaptar y diseñar controladores de motor para un gran rango de aplicaciones. En el campo específico de la robótica u otra maquinaria diseñada para interactuar con los humanos o con su entorno, nuevas necesidades y soluciones tecnológicas se siguen desarrollado debido al relativamente inexplorado y nuevo escenario que supone. El proyecto consta de tres partes principales: Dos sistemas basados en VHDL y un pequeño experimento sobre la percepción háptica. Ambos sistemas VHDL están basados en el Cognitive Sesnorimotor Loop (CSL) que es un lazo de control creado por el NRL y cuyo desarrollador principal ha sido Dr. Prof. Hild. El CSL es un lazo de control cuya principal característica es la ausencia de sensores externos para medir la velocidad o la posición del motor, usando el propio motor como sensor. El motor siempre genera un voltaje proporcional a su velocidad angular de modo que no es necesaria calibración. Este método es eficiente en términos energéticos y simplifica los lazos de control en sistemas complejos. El primer sistema, llamado CSL Stay In Touch (SIT), consiste en un sistema formado por un motor DC controlado por una FPGA Board (Zynq ZYBO 7000) cuyo objetivo es mantener contacto con cualquier objeto externo que toque su plataforma sensible en ambas direcciones. Aparte del funcionamiento básico, tres modos (Search Mode, Inertia Mode y Return Mode) han sido diseñados para mejorar la interacción. Adicionalmente, se ha diseñado el control a través de la FPGA Board de una pantalla VGA para la monitorización de todo el sistema. El sistema ha sido totalmente desarrollado, testeado y mejorado; analizando su propiedades de timing y consumo energético. El segundo sistema, llamado CSL Fingerlike Mechanism (FM), consiste en un mecanismo similar a un dedo controlado por dos motores DC (Cada uno controlando una falange). Su comportamiento es similar al del primer sistema pero con una estructura más compleja. Este sistema no formaba parte de los objetivos iniciales del proyecto y por lo tanto era opcional. No pudo ser plenamente desarrollado debido a la falta de tiempo. El experimento de percepción háptica fue diseñado para profundizar en la percepción háptica humana con el objetivo de aplicar este conocimiento en aplicaciones tecnológicas. El experimento consistía en testear la capacidad de los sujetos para reconocer diferentes objetos, formas y texturas en condiciones de privación del sentido del oído y la vista. Se crearon dos grupos, en uno los sujetos tenían plena percepción háptica mientras que en el otro debían interactuar con los objetos a través de una pieza de plástico para generar un hándicap háptico. La conclusión del proyecto fue que un sistema háptico basado solo en sistemas CSL no es suficiente para recopilar información valiosa del entorno y que debe hacer uso de otros sensores (temperatura, presión, etc.). En cambio, un sistema basado en CSL es idóneo para el control de la fuerza aplicada por el sistema durante la interacción con superficies hápticas sensibles tales como la piel o pantallas táctiles.
Resumo:
In Bohmian mechanics, a version of quantum mechanics that ascribes world lines to electrons, we can meaningfully ask about an electron's instantaneous speed relative to a given inertial frame. Interestingly, according to the relativistic version of Bohmian mechanics using the Dirac equation, a massive particle's speed is less than or equal to the speed of light, but not necessarily less. That is, there are situations in which the particle actually reaches the speed of light-a very nonclassical behavior. That leads us to the question of whether such situations can be arranged experimentally. We prove a theorem, Theorem 5, implying that for generic initial wave functions the probability that the particle ever reaches the speed of light, even if at only one point in time, is zero. We conclude that the answer to the question is no. Since a trajectory reaches the speed of light whenever the quantum probability current (psi) over bar gamma(mu)psi is a lightlike 4-vector, our analysis concerns the current vector field of a generic wave function and may thus be of interest also independently of Bohmian mechanics. The fact that the current is never spacelike has been used to argue against the possibility of faster-than-light tunneling through a barrier, a somewhat similar question. Theorem 5, as well as a more general version provided by Theorem 6, are also interesting in their own right. They concern a certain property of a function psi : R(4) -> C(4) that is crucial to the question of reaching the speed of light, namely being transverse to a certain submanifold of C(4) along a given compact subset of space-time. While it follows from the known transversality theorem of differential topology that this property is generic among smooth functions psi : R(4) -> C(4), Theorem 5 asserts that it is also generic among smooth solutions of the Dirac equation. (C) 2010 American Institute of Physics. [doi:10.1063/1.3520529]