942 resultados para Induced Refractive Errors


Relevância:

100.00% 100.00%

Publicador:

Resumo:

This research pursued the conceptualization, implementation, and verification of a system that enhances digital information displayed on an LCD panel to users with visual refractive errors. The target user groups for this system are individuals who have moderate to severe visual aberrations for which conventional means of compensation, such as glasses or contact lenses, does not improve their vision. This research is based on a priori knowledge of the user's visual aberration, as measured by a wavefront analyzer. With this information it is possible to generate images that, when displayed to this user, will counteract his/her visual aberration. The method described in this dissertation advances the development of techniques for providing such compensation by integrating spatial information in the image as a means to eliminate some of the shortcomings inherent in using display devices such as monitors or LCD panels. Additionally, physiological considerations are discussed and integrated into the method for providing said compensation. In order to provide a realistic sense of the performance of the methods described, they were tested by mathematical simulation in software, as well as by using a single-lens high resolution CCD camera that models an aberrated eye, and finally with human subjects having various forms of visual aberrations. Experiments were conducted on these systems and the data collected from these experiments was evaluated using statistical analysis. The experimental results revealed that the pre-compensation method resulted in a statistically significant improvement in vision for all of the systems. Although significant, the improvement was not as large as expected for the human subject tests. Further analysis suggest that even under the controlled conditions employed for testing with human subjects, the characterization of the eye may be changing. This would require real-time monitoring of relevant variables (e.g. pupil diameter) and continuous adjustment in the pre-compensation process to yield maximum viewing enhancement.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

To determine the prevalence of refractive errors in the public and private school system in the city of Natal, Northeastern Brazil. Methods: Refractometry was performed on both eyes of 1,024 randomly selected students, enrolled in the 2001 school year and the data were evaluated by the SPSS Data Editor 10.0. Ametropia was divided into: 1- from 0.1 to 0.99 diopter (D); 2- 1.0 to 2.99D; 3- 3.00 to 5.99D and 4- 6D or greater. Astigmatism was regrouped in: I- with-the-rule (axis from 0 to 30 and 150 to 180 degrees), II- against-the-rule (axis between 60 and 120 degrees) and III- oblique (axis between > 30 and < 60 and >120 and <150 degrees). The age groups were categorized as follows, in: 1- 5 to 10 years, 2- 11 to 15 years, 3- 16 to 20 years, 4- over 21 years. Results: Among refractive errors, hyperopia was the most common with 71%, followed by astigmatism (34%) and myopia (13.3%). Of the students with myopia and hyperopia, 48.5% and 34.1% had astigmatism, respectively. With respect to diopters, 58.1% of myopic students were in group 1, and 39% distributed between groups 2 and 3. Hyperopia were mostly found in group 1 (61.7%) as well as astigmatism (70.6%). The association of the astigmatism axes of both eyes showed 92.5% with axis with-the-rule in both eyes, while the percentage for those with axis againstthe- rule was 82.1% and even lower for the oblique axis (50%). Conclusion: The results found differed from those of most international studies, mainly from the Orient, which pointed to myopia as the most common refractive error, and corroborates the national ones, with the majority being hyperopia

Relevância:

100.00% 100.00%

Publicador:

Resumo:

To determine the prevalence of refractive errors in the public and private school system in the city of Natal, Northeastern Brazil. Methods: Refractometry was performed on both eyes of 1,024 randomly selected students, enrolled in the 2001 school year and the data were evaluated by the SPSS Data Editor 10.0. Ametropia was divided into: 1- from 0.1 to 0.99 diopter (D); 2- 1.0 to 2.99D; 3- 3.00 to 5.99D and 4- 6D or greater. Astigmatism was regrouped in: I- with-the-rule (axis from 0 to 30 and 150 to 180 degrees), II- against-the-rule (axis between 60 and 120 degrees) and III- oblique (axis between > 30 and < 60 and >120 and <150 degrees). The age groups were categorized as follows, in: 1- 5 to 10 years, 2- 11 to 15 years, 3- 16 to 20 years, 4- over 21 years. Results: Among refractive errors, hyperopia was the most common with 71%, followed by astigmatism (34%) and myopia (13.3%). Of the students with myopia and hyperopia, 48.5% and 34.1% had astigmatism, respectively. With respect to diopters, 58.1% of myopic students were in group 1, and 39% distributed between groups 2 and 3. Hyperopia were mostly found in group 1 (61.7%) as well as astigmatism (70.6%). The association of the astigmatism axes of both eyes showed 92.5% with axis with-the-rule in both eyes, while the percentage for those with axis againstthe- rule was 82.1% and even lower for the oblique axis (50%). Conclusion: The results found differed from those of most international studies, mainly from the Orient, which pointed to myopia as the most common refractive error, and corroborates the national ones, with the majority being hyperopia

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Myopia (short-sightedness) is a visual problem associated with excessive eye growth and vitreous chamber expansion. Within the eye serotonin (5-hydroxytryptamine, 5-HT) appears to have a variety of effects, it alters retinal amacrine cell processing, increases intraocular pressure, constricts ocular blood vessels, and is also mitogenic. This study sought to determine the role of the retinal serotonin system in eye growth regulation. Myopia was produced in 7-day-old chicks using -15 D spectacle lenses (LIM) and form deprivation (FDM). The effect on LIM and FDM of daily intravitreal injections of a combination of 5-HT receptor antagonists (1, 10, 50 mu M), 5-HT2 selective antagonist (Mianserin 0.5, 20 mu M) were assessed. Counts were performed of serotonin and tyrosine hydroxylase positive neurons and the relative density used to account for areal changes due to eye growth. The effect of LIM and lens-induced hyperopia (LIH) on the numbers of 5-HT-containing amacrine cells in the retina were then determined. The combination of the 5-HT receptor antagonists inhibited LIM by approximately half (1 mu M RE: -7.12 +/- 1.0 D, AL: 0.38 +/- 0.06 mm vs. saline RE: -13.19 +/- 0.65 D, AL: 0.64 +/- 0.03 mm. RE: p < 0.01, AL: p < 0.01), whereas FDM was not affected (1 mu M RE: -8.88 +/- 1.10 D). These data suggest that serotonin has a stimulatory role in LIM, although high doses of serotonin were inhibitory (1 mu M RE: -9.30 +/- 1.34 D). 5-HT immunoreactivity was localised to a subset of amacrine cell bodies in the inner nuclear layer of the retina, and to two synaptic strata in the inner plexiform layer. LIM eyes had increased numbers of 5-HT-containing amacrine cells in the central retina (12.5%). Collectively, these results suggest that manipulations to the serotonin system can alter the eye growth process but the role of the transmitter system within this process remains unclear. (c) 2005 Elsevier Ltd. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Background: Few studies have specifically investigated the functional effects of uncorrected astigmatism on measures of reading fluency. This information is important to provide evidence for the development of clinical guidelines for the correction of astigmatism. Methods: Participants included 30 visually normal, young adults (mean age 21.7 ± 3.4 years). Distance and near visual acuity and reading fluency were assessed with optimal spectacle correction (baseline) and for two levels of astigmatism, 1.00DC and 2.00DC, at two axes (90° and 180°) to induce both against-the-rule (ATR) and with-the-rule (WTR) astigmatism. Reading and eye movement fluency were assessed using standardized clinical measures including the test of Discrete Reading Rate (DRR), the Developmental Eye Movement (DEM) test and by recording eye movement patterns with the Visagraph (III) during reading for comprehension. Results: Both distance and near acuity were significantly decreased compared to baseline for all of the astigmatic lens conditions (p < 0.001). Reading speed with the DRR for N16 print size was significantly reduced for the 2.00DC ATR condition (a reduction of 10%), while for smaller text sizes reading speed was reduced by up to 24% for the 1.00DC ATR and 2.00DC condition in both axis directions (p<0.05). For the DEM, sub-test completion speeds were significantly impaired, with the 2.00DC condition affecting both vertical and horizontal times and the 1.00DC ATR condition affecting only horizontal times (p<0.05). Visagraph reading eye movements were not significantly affected by the induced astigmatism. Conclusions: Induced astigmatism impaired performance on selected tests of reading fluency, with ATR astigmatism having significantly greater effects on performance than did WTR, even for relatively small amounts of astigmatic blur of 1.00DC. These findings have implications for the minimal prescribing criteria for astigmatic refractive errors.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

We report femtosecond laser induced valence state and refractive index change in transparent Sin(3+)-doped fluoroaluminate glass. The effect of annealing on the induced changes was studied and the thermal stability of these changes was discussed. The results show that the femtosecond laser induced valence state change is more stable than the induced refractive index change. The observed phenomenon could be applied to design the thermally erasable or stable storage medium. (c) 2007 Elsevier B.V. All rights reserved.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Contact lenses are a common method for the correction of refractive errors of the eye. While there have been significant advancements in contact lens designs and materials over the past few decades, the lenses still represent a foreign object in the ocular environment and may lead to physiological as well as mechanical effects on the eye. When contact lenses are placed in the eye, the ocular anatomical structures behind and in front of the lenses are directly affected. This thesis presents a series of experiments that investigate the mechanical and physiological effects of the short-term use of contact lenses on anterior and posterior corneal topography, corneal thickness, the eyelids, tarsal conjunctiva and tear film surface quality. The experimental paradigm used in these studies was a repeated measures, cross-over study design where subjects wore various types of contact lenses on different days and the lenses were varied in one or more key parameters (e.g. material or design). Both, old and newer lens materials were investigated, soft and rigid lenses were used, high and low oxygen permeability materials were tested, toric and spherical lens designs were examined, high and low powers and small and large diameter lenses were used in the studies. To establish the natural variability in the ocular measurements used in the studies, each experiment also contained at least one “baseline” day where an identical measurement protocol was followed, with no contact lenses worn. In this way, changes associated with contact lens wear were considered in relation to those changes that occurred naturally during the 8 hour period of the experiment. In the first study, the regional distribution and magnitude of change in corneal thickness and topography was investigated in the anterior and posterior cornea after short-term use of soft contact lenses in 12 young adults using the Pentacam. Four different types of contact lenses (Silicone hydrogel/ Spherical/–3D, Silicone Hydrogel/Spherical/–7D, Silicone Hydrogel/Toric/–3D and HEMA/Toric/–3D) of different materials, designs and powers were worn for 8 hours each, on 4 different days. The natural diurnal changes in corneal thickness and curvature were measured on two separate days before any contact lens wear. Significant diurnal changes in corneal thickness and curvature within the duration of the study were observed and these were taken into consideration for calculating the contact lens induced corneal changes. Corneal thickness changed significantly with lens wear and the greatest corneal swelling was seen with the hydrogel (HEMA) toric lens with a noticeable regional swelling of the cornea beneath the stabilization zones, the thickest regions of the lenses. The anterior corneal surface generally showed a slight flattening with lens wear. All contact lenses resulted in central posterior corneal steepening, which correlated with the relative degree of corneal swelling. The corneal swelling induced by the silicone hydrogel contact lenses was typically less than the natural diurnal thinning of the cornea over this same period (i.e. net thinning). This highlights why it is important to consider the natural diurnal variations in corneal thickness observed from morning to afternoon to accurately interpret contact lens induced corneal swelling. In the second experiment, the relative influence of lenses of different rigidity (polymethyl methacrylate – PMMA, rigid gas permeable – RGP and silicone hydrogel – SiHy) and diameters (9.5, 10.5 and 14.0) on corneal thickness, topography, refractive power and wavefront error were investigated. Four different types of contact lenses (PMMA/9.5, RGP/9.5, RGP/10.5, SiHy/14.0), were worn by 14 young healthy adults for a period of 8 hours on 4 different days. There was a clear association between fluorescein fitting pattern characteristics (i.e. regions of minimum clearance in the fluorescein pattern) and the resulting corneal shape changes. PMMA lenses resulted in significant corneal swelling (more in the centre than periphery) along with anterior corneal steepening and posterior flattening. RGP lenses, on the other hand, caused less corneal swelling (more in the periphery than centre) along with opposite effects on corneal curvature, anterior corneal flattening and posterior steepening. RGP lenses also resulted in a clinically and statistically significant decrease in corneal refractive power (ranging from 0.99 to 0.01 D), large enough to affect vision and require adjustment in the lens power. Wavefront analysis also showed a significant increase in higher order aberrations after PMMA lens wear, which may partly explain previous reports of "spectacle blur" following PMMA lens wear. We further explored corneal curvature, thickness and refractive changes with back surface toric and spherical RGP lenses in a group of 6 subjects with toric corneas. The lenses were worn for 8 hours and measurements were taken before and after lens wear, as in previous experiments. Both lens types caused anterior corneal flattening and a decrease in corneal refractive power but the changes were greater with the spherical lens. The spherical lens also caused a significant decrease in WTR astigmatism (WRT astigmatism defined as major axis within 30 degrees of horizontal). Both the lenses caused slight posterior corneal steepening and corneal swelling, with a greater effect in the periphery compared to the central cornea. Eyelid position, lid-wiper and tarsal conjunctival staining were also measured in Experiment 2 after short-term use of the rigid and SiHy contact lenses. Digital photos of the external eyes were captured for lid position analysis. The lid-wiper region of the marginal conjunctiva was stained using fluorescein and lissamine green dyes and digital photos were graded by an independent masked observer. A grading scale was developed in order to describe the tarsal conjunctival staining. A significant decrease in the palpebral aperture height (blepharoptosis) was found after wearing of PMMA/9.5 and RGP/10.5 lenses. All three rigid contact lenses caused a significant increase in lid-wiper and tarsal staining after 8 hours of lens wear. There was also a significant diurnal increase in tarsal staining, even without contact lens wear. These findings highlight the need for better contact lens edge design to minimise the interactions between the lid and contact lens edge during blinking and more lubricious contact lens surfaces to reduce ocular surface micro-trauma due to friction and for. Tear film surface quality (TFSQ) was measured using a high-speed videokeratoscopy technique in Experiment 2. TFSQ was worse with all the lenses compared to baseline (PMMA/9.5, RGP/9.5, RGP/10.5, and SiHy/14) in the afternoon (after 8 hours) during normal and suppressed blinking conditions. The reduction in TFSQ was similar with all the contact lenses used, irrespective of their material and diameter. An unusual pattern of change in TFSQ in suppressed blinking conditions was also found. The TFSQ with contact lens was found to decrease until a certain time after which it improved to a value even better than the bare eye. This is likely to be due to the tear film drying completely over the surface of the contact lenses. The findings of this study also show that there is still a scope for improvement in contact lens materials in terms of better wettability and hydrophilicity in order to improve TFSQ and patient comfort. These experiments showed that a variety of changes can occur in the anterior eye as a result of the short-term use of a range of commonly used contact lens types. The greatest corneal changes occurred with lenses manufactured from older HEMA and PMMA lens materials, whereas modern SiHy and rigid gas permeable materials caused more subtle changes in corneal shape and thickness. All lenses caused signs of micro-trauma to the eyelid wiper and palpebral conjunctiva, although rigid lenses appeared to cause more significant changes. Tear film surface quality was also significantly reduced with all types of contact lenses. These short-term changes in the anterior eye are potential markers for further long term changes and the relative differences between lens types that we have identified provide an indication of areas of contact lens design and manufacture that warrant further development.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Melanopsin containing intrinsically photosensitive Retinal Ganglion cells (ipRGCs) mediate the pupil light reflex (PLR) during light onset and at light offset (the post-illumination pupil response, PIPR). Recent evidence shows that the PLR and PIPR can provide non-invasive, objective markers of age-related retinal and optic nerve disease, however there is no consensus on the effects of healthy ageing or refractive error on the ipRGC mediated pupil function. Here we isolated melanopsin contributions to the pupil control pathway in 59 human participants with no ocular pathology across a range of ages and refractive errors. We show that there is no effect of age or refractive error on ipRGC inputs to the human pupil control pathway. The stability of the ipRGC mediated pupil response across the human lifespan provides a functional correlate of their robustness observed during ageing in rodent models.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Refractive errors, especially myopia, seem to increase worldwide. Concurrently, the number of surgical refractive corrections has increased rapidly, with several million procedures performed annually. However, excimer laser surgery was introduced after a limited number of studies done with animals and to date there still are only few long-term follow-up studies of the results. The present thesis aims to evaluate the safety and functional outcome of, as well as to quantify the cellular changes and remodelling in the human cornea after, photorefractive keratectomy (PRK) and laser assisted in situ keratomileusis (LASIK). These procedures are the two most common laser surgical refractive methods. In Study I, myopic ophthalmic residents at Helsinki University Eye Hospital underwent a refractive correction by PRK. Five patients were followed up for 6 months to assess their subjective experience in hospital work and their performance in car driving simulator and in other visuomotor functions. Corneal morphological changes were assessed by in vivo confocal microscopy (ivCM). Study II comprised 14 patients who had undergone a PRK operation in 1993-1994. Visual acuity was examined and ivCM examinations performed 5 years postoperatively. In Study III 15 patients received LASIK refractive correction for moderate to high myopia (-6 - -12 D). Their corneal recovery was followed by ivCM for 2 years. Diffuse lamellar keratitis (DLK) is a common but variable complication of LASIK. Yet, its aetiology remains unknown. In Study IV we examined six patients who had developed DLK as a consequence of formation of an intraoperative or post-LASIK epithelial defect, to assess the corneal and conjunctival inflammatory reaction. In the whole series, the mean refractive correction was -6.46 diopters. The best spectacle corrected visual acuity (BSCVA) improved in 30 % of patients, whereas in four patients BSCVA decreased slightly. The mean achieved refraction was 0.35 D undercorrected. After PRK, the stromal scar formation was highest at 2 to 3 months postoperatively and subsequently decreased. At 5 years increased reflectivity in the subepithelial stroma was observed in all patients. Interestingly, no Bowman s layer was detected in any patient. Subbasal nerve fiber bundle(snfb) regeneration could be observed already at 2 months in 2 patients after PRK. After 5 years, all corneas presented with snfb, the density of which, however, was still lower than in control corneas. LASIK induced a hypocellular area on both sides of the flap interface. A decrease of the most anterior keratocyte density was also observed. In the corneas that developed DLK, inflammatory cell-type objects were present in the flap interface in half of the patients. The other patients presented only with keratocyte activation and highly reflective extracellular matrix. These changes resolved completely with medication and time. Snfb regeneration was first detected at one month post-LASIK, but still after two years the density of snfb, however, was only 64 % of the preoperative values. The performance of ophthalmological examinations and microsurgery without spectacles was easier postoperatively, which was appreciated by the residents. Both PRK and LASIK showed moderate to good accuracy and high safety. In terms of visual perception and subjective evaluation, few patients stated any complaints in the whole series of studies. Instead, the majority of patients experienced a marked improvement in everyday life and work performance. PRK and LASIK have shown similar results, with good long term morphological healing. It seems evident that, even without the benefit of over-20-year follow-up results, these procedures are sufficiently safe and accurate for refractive corrections and corneal reshaping.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Atomic force microscopy and photoluminescence spectroscopy (PL) has been used to study asymmetric bilayer InAs quantum dot (QD) structures grow by molecular-beam epitaxy on GaAs (001) substrates. The two InAs layers were separated by a 7-nm-thick GaAs spacer layer and were grown at different substrate temperature. We took advantage of the intrinsic nonuniformity of the molecular beams to grow the seed layer with an average InAs coverage of 2.0 ML. Then the seed layer thickness could be divided into three areas: below, around and above the critical thickness of the 2D-3D transition along the 11101 direction of the substrate. Correspondingly, the nucleation mechanisms of the upper InAs layer (UIL) could be also divided into three areas: temperature-controlled, competition between temperature-controlled and strain-induced, and strain-induced (template-controlled) nucleation. Small quantum dots (QDs) with a large density around 5 x 10(10) cm(-2) are found in the temperature-controlled nucleation area. The QD size distributions undergo a bimodal to a unimodal transition with decreasing QD densities in the strain-induced nucleation area, where the QD densities vary following that of the seed layer (templating effect). The optimum QD density with the UIL thickness fixed at 2.4 ML is shown to be around 1.5 x 10(10) cm(-2), for which the QD size distribution is unimodal and PL emission peaks at the longest wavelength. The QDs in the in-between area exhibit a broad size distribution with small QDs and strain-induced large QDs coexisting.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

OBJECTIVE: To study spectacle wear among rural Chinese children. METHODS: Visual acuity, refraction, spectacle wear, and visual function were measured. RESULTS: Among 1892 subjects (84.7% of the sample), the mean (SD) age was 14.7 (0.8) years. Among 948 children (50.1%) potentially benefiting from spectacle wear, 368 (38.8%) did not own them. Among 580 children owning spectacles, 17.9% did not wear them at school. Among 476 children wearing spectacles, 25.0% had prescriptions that could not improve their visual acuity to better than 6/12. Therefore, 62.3% (591 of 948) of children needing spectacles did not benefit from appropriate correction. Children not owning and not wearing spectacles had better self-reported visual function but worse visual acuity at initial examination than children wearing spectacles and had a mean (SD) refractive error of -2.06 (1.15) diopter (D) and -2.78 (1.32) D, respectively. Girls (P < .001) and older children (P = .03) were more likely to be wearing their spectacles. A common reason for nonwear (17.0%) was the belief that spectacles weaken the eyes. Among children without spectacles, 79.3% said their families would pay for them (mean, US $15). CONCLUSIONS: Although half of the children could benefit from spectacle wear, 62.3% were not wearing appropriate correction. These children have significant uncorrected refractive errors. There is potential to support programs through spectacle sales.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

The propagation of an optical beam through dielectric media induces changes in the refractive index, An, which causes self-focusing or self-defocusing. In the particular case of ion-doped solids, there are thermal and non-thermal lens effects, where the latter is due to the polarizability difference, Delta alpha, between the excited and ground states, the so-called population lens (PL) effect. PL is a pure electronic contribution to the nonlinearity, while the thermal lens (TL) effect is caused by the conversion of part of the absorbed energy into heat. In time-resolved measurements such as Z-scan and TL transient experiments, it is not easy to separate these two contributions to nonlinear refractive index because they usually have similar response times. In this work, we performed time-resolved measurements using both Z-scan and mode mismatched TL in order to discriminate thermal and electronic contributions to the laser-induced refractive index change of the Nd3+-doped Strontium Barium Niobate (SrxBa1-xNb2O6) laser crystal. Combining numerical simulations with experimental results we could successfully distinguish between the two contributions to An. (C) 2007 Elsevier B.V. All rights reserved.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

90.00% 90.00%

Publicador:

Resumo:

The photosensitivity of GeSx binary glasses in response to irradiation to femtosecond pulses at 800 nm is investigated. Samples with three different molecular compositions were irradiated under different exposure conditions. The material response to laser exposure was characterized by both refractometry and micro-Raman spectroscopy. It is shown that the relative content of sulfur in the glass matrix influences the photo-induced refractive index modification. At low sulfur content, both positive and negative index changes can be obtained while at high sulfur content, only a positive index change can be reached. These changes were correlated with variations in the Raman response of exposed glass which were interpreted in terms of structural modifications of the glass network. Under optimized exposure conditions, waveguides with positive index changes of up to 7.8x10−3 and a controllable diameter from 14 to 25 μm can be obtained. Direct inscription of low insertion losses (IL = 3.1 – 3.9 dB) waveguides is demonstrated in a sample characterized by a S/Ge ratio of 4. The current results open a pathway towards the use of Ge-S binary glasses for the fabrication of integrated mid-infrared photonic components.