994 resultados para Implante dentário - Infiltração bacteriana


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

One of the complications that concern prosthetists is bone loss peri-implant, because the success of dental implant treatment requires long-term maintenance of hard and soft tissues around the implant. Whereby the dental implants have not only the goal of restoring function, but also the aesthetics of the patient, the bone loss peri-implant can dramatically compromise the aesthetics of rehabilitation, particularly in anterior regions. The aim of this study was to analyze and reason, through literature review, the main factors that can cause bone loss in peri-implant and possible ways to prevent it.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The identification and treatment of peri-implant infections are an essential stage in the maintenance of dental implants, reflecting the longevity of rehabilitation. Therefore, the aim of the study was to conduct a literature review addressing peri-implantitis in dental implants in order to guide planning for the longevity of oral rehabilitation. It was conducted a detailed search strategy by the PubMed / Medline Dentistry and Oral Science, it was used as descriptors: “peri-implantitis” and “Dental Implant”, until July 2013. From 566 articles, after a review, according to the inclusion criteria, 34 articles were selected. The results were grouped together in topics (concept, etiology, diagnosis, surgical and nonsurgical, and aspects of oral rehabilitation) for further discussion and conclusions. Conclusions: The accumulation of plaque has been associated with a higher propensity to peri-implantitis. There is a higher incidence of the peri-implantitis disease among patients with previous history of periodontal disease. The local administration of antibiotics and association with mouthwashes / topical use are indicated as suitable for the treatment of moderate peri-implantitis.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The aim of this study was to evaluate the influence of implant angulation and abutment type (UCLA and Estheticone) on stress distribution in screw-retained implant-supported prostheses through photoelasticity. Three models were fabricated with photoelastic resin PL-2 (Vishay, Micro-Measurements Group, Inc Raleigh, N.C., USA) containing one external hexagon implant with 3.75x10mm (Master screw, Conexão Sistemas de Prótese Ltda., Arujá, São Paulo) with 0°, 17° and 30° degrees and a screw-retained prostheses with UCLA and Estheticone abutments. The assembly was positioned in a circular polariscope; axial and oblique (45° degrees) loads of 100N were applied in fixed points on the occlusal crown surfaces by a universal testing machine. The stress generated was photographed and analyzed qualitatively with appropriate software (Adobe Photoshop®). The results demonstrated the same number of fringes for both abutment types for each angulation, with fringes increasing in the same way. A higher number of fringes were closer in the oblique loading mode. It was concluded that there was no significant difference in stress distribution in prostheses with UCLA and Estheticone abutments. Higher stress concentrations were observed with increased implant angulation. Stress concentration and intensity were higher in the oblique load than in axial load application.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

TEMA: a produção da fala nas modalidades de reabilitação oral protética. OBJETIVO: verificar se o tipo de reabilitação oral interfere na produção da fala. MÉTODO: 36 idosos (média = 68 anos), divididos em 3 grupos, foram avaliados: 13 com dentes naturais (A), 13 com prótese total mucosossuportada superior e inferior (B) e 10 com prótese total mucosossuportada superior e implantossuportada inferior (C). A estabilidade das próteses foi avaliada por um dentista e amostras de fala foram analisadas por 5 fonoaudiólogos. Para determinar a freqüência de alteração dos sons da fala utilizou-se o cálculo da Porcentagem de Consoantes Corretas (PCC). RESULTADOS: observou-se poucos casos com alteração de fala, com maior freqüência no grupo C (23,08%), sendo a articulação travada presente em todos os grupos, a redução dos movimentos labiais em dois grupos (A e B) e a articulação exagerada e a falta de controle salivar em um dos grupos (C e B). Quanto à PCC, menor valor foi observado para os fones linguodentais nos grupos B e C (maior ocorrência de alteração), seguido dos fones alveolares, predominando casos sem alteração no grupo A, contrariamente aos demais grupos, sendo a projeção lingual e o ceceio as alterações mais encontradas. Não houve diferença entre os grupos e a maioria do grupo B estava com a prótese inferior insatisfatória, não havendo associação entre alteração de fala e prótese insatisfatória. CONCLUSÃO: apesar da amostra pequena, indivíduos reabilitados com prótese total apresentam alteração nos fones linguodentais e alveolares e o tipo de prótese, bem como a estabilidade desta parece não interferir na produção da fala.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This study evaluated the sealing ability of different lengths of remaining root canal filling and post space preparation against coronal leakage of Enterococcus faecalis. Forty-one roots of maxillary incisors were biomechanically prepared, maintaining standardized canal diameter at the middle and coronal thirds. The roots were autoclaved and all subsequent steps were undertaken in a laminar flow chamber. The canals of 33 roots were obturated with AH Plus sealer and gutta-percha. The root canal fillings were reduced to 3 predetermined lengths (n=11): G1=6 mm, G2=4 mm and G3=2 mm. The remaining roots served as positive and negative controls. Bacterial leakage test apparatuses were fabricated with the roots attached to Eppendorf tubes keeping 2 mm of apex submerged in BHI in glass flasks. The specimens received an E. faecalis inoculum of 1 x 107 cfu/mL every 3 days and were observed for bacterial leakage daily during 60 days. Data were submitted to ANOVA, Tukey's test and Fisher's test. At 60 days, G1 (6 mm) and G2 (4 mm) presented statistically similar results (p>0.05) (54.4% of specimens with bacterial leakage) and both groups differed significantly (p<0.01) from G3 (2 mm), which presented 100% of specimens with E. faecalis leakage. It may be concluded that the shortest endodontic obturation remnant leaked considerably more than the other lengths, although none of the tested conditions avoids coronal leakage of E. faecalis.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

OBJETIVOS: A ingestão de álcalis provoca graves lesões no tubo digestório alto. A comercialização de substâncias cáusticas em forma líquida facilita o seu uso com intenções suicidas e torna as afecções por elas provocadas relativamente comuns. Nesse sentido, o objetivo do presente trabalho foi avaliar as conseqüências morfológicas da infusão de substância cáustica no estômago murino. MÉTODO: Foram estudados 20 ratos Wistar adultos, de ambos os sexos. Após jejum alimentar de 12 horas, instilou-se 1ml de hidróxido de sódio (NaOH) a 5% através de cateter orogástrico. Os ratos foram divididos aleatoriamente em quatro grupos (n=5), de acordo com o tempo de acompanhamento: 24 horas, sete dias, 30 dias e 90 dias, respectivamente. Decorrido o tempo de acompanhamento, os ratos foram mortos e seus estômagos foram avaliados macro e microscopicamente. RESULTADOS: Após 24 horas, os estômagos estavam dilatados e com aderências ao fígado, omentos e pâncreas. Suas mucosa e submucosa apresentavam áreas de necrose de coagulação do corpo e do antro entremeada por intensa infiltração bacteriana. Após sete dias, os estômagos permaneciam dilatados e mantendo o mesmo padrão necrótico anterior, porém sem os focos sépticos. Nos grupos de um e três meses, a cavidade abdominal teve aspecto normal. Os estômagos apresentavam consistência endurecida e com proliferação fibrovascular. CONCLUSÃO: Os animais que sobreviveram à necrose e à intensa infiltração bacteriana da primeira semana desenvolveram reparação progressiva de seus estômagos, porém acompanhada de complicações decorrentes da fibrose cicatricial.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

OBJETIVOS: As dificuldades para a utilização de implantes dentários osteointegrados em pacientes portadores de atrofia do seio maxilar justificaram o emprego de enxerto autólogo não vascularizado de crista ilíaca isolado ou associado à hidroxiapatita (HA) em 14 pacientes submetidos a 25 procedimentos no Hospital das Nações, Curitiba, Paraná, portadores de atrofia do sinus maxilar. O objetivo foi avaliar comparativamente a precisão da tomografia computadorizada e da radiografia panorâmica, através da quantificação da neoformação óssea nesta estrutura. MÉTODOS: Foram selecionadas pacientes edentados, com altura óssea residual do rebordo gengival ao soalho do seio maxilar menor que 5mm. O enxerto medular de crista ilíaca fragmentada isolado ou misturado com HA foi colocado através da parede lateral no soalho atrófico da cuba maxilar por via submucosa. A avaliação quantitativa e qualitativa foi feita através da radiografia panorâmica e tomografia computadorizada, sendo utilizado na análise estatística a distribuição t de Student (prevalência de 0,05) para análise das variâncias, considerado que a leitura dos laudos radiológicos foi feita por dois especialistas, medindo a distância entre os pontos inferiores e superiores do enxerto no soalho do seio maxilar. RESULTADOS: Tivemos um ganho médio de 14,8mm em todos os procedimentos, com um erro maior que 3mm em 16 procedimentos (64%) e incorporação satisfatória do enxerto ósseo suficiente para futuro implante dentário. CONCLUSÕES: A tomografia computadorizada foi o método de escolha na avaliação qualitativa e quantitativa da incorporação de enxerto autólogo não vascularizado em seio maxilar atrófico.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In recent years there has been a significant growth in technologies that modify implant surfaces, reducing healing time and allowing their successful use in areas with low bone density. One of the most widely used techniques is plasma nitration, applied with excellent results in titanium and its alloys, with greater frequency in the manufacture of hip, ankle and shoulder implants. However, its use in dental implants is very limited due to high process temperatures (between 700 C o and 800 C o ), resulting in distortions in these geometrically complex and highly precise components. The aim of the present study is to assess osseointegration and mechanical strength of grade II nitrided titanium samples, through configuration of hollow cathode discharge. Moreover, new formulations are proposed to determine the optimum structural topology of the dental implant under study, in order to perfect its shape, make it efficient, competitive and with high definition. In the nitriding process, the samples were treated at a temperature of 450 C o and pressure of 150 Pa , during 1 hour of treatment. This condition was selected because it obtains the best wettability results in previous studies, where different pressure, temperature and time conditions were systematized. The samples were characterized by X-ray diffraction, scanning electron microscope, roughness, microhardness and wettability. Biomechanical fatigue tests were then conducted. Finally, a formulation using the three dimensional structural topology optimization method was proposed, in conjunction with an hadaptive refinement process. The results showed that plasma nitriding, using the hollow cathode discharge technique, caused changes in the surface texture of test specimens, increases surface roughness, wettability and microhardness when compared to the untreated sample. In the biomechanical fatigue test, the treated implant showed no flaws, after five million cycles, at a maximum fatigue load of 84.46 N. The results of the topological optimization process showed well-defined optimized layouts of the dental implant, with a clear distribution of material and a defined edge