971 resultados para Immunologic Tests -- methods
Resumo:
OBJECTIVE:: Lactic acid bacteria (LAB) are used in food industries as probiotic agents. The aim of this study is to assess the potential health effects of airborne exposure to a mix of preblend (LAB and carbohydrate) and milk powder in workers. METHODS:: A medical questionnaire, lung function tests, and immunologic tests were carried out on 50 workers. Occupational exposure to inhalable dust and airborne LAB was measured. RESULTS:: Workers not using respiratory masks reported more symptoms of irritation than workers using protection. Workers from areas with higher levels of airborne LAB reported the most health symptoms and the immune responses of workers to LAB was higher than the immune responses of a control population. CONCLUSIONS:: Measures to reduce exposure to airborne LAB and milk powder in food industries are recommended.
Resumo:
PURPOSE: To investigate the effect of intraocular straylight (IOS) induced by white opacity filters (WOF) on threshold measurements for stimuli employed in three perimeters: standard automated perimetry (SAP), pulsar perimetry (PP) and the Moorfields motion displacement test (MDT).¦METHODS: Four healthy young (24-28 years old) observers were tested six times with each perimeter, each time with one of five different WOFs and once without, inducing various levels of IOS (from 10% to 200%). An increase in IOS was measured with a straylight meter. The change in sensitivity from baseline was normalized, allowing comparison of standardized (z) scores (change divided by the SD of normative values) for each instrument.¦RESULTS: SAP and PP thresholds were significantly affected (P < 0.001) by moderate to large increases in IOS (50%-200%). The drop in motion displacement (MD) from baseline with WOF 5, was approximately 5 dB, in both SAP and PP which represents a clinically significant loss; in contrast the change in MD with MDT was on average 1 minute of arc, which is not likely to indicate a clinically significant loss.¦CONCLUSIONS: The Moorfields MDT is more robust to the effects of additional straylight in comparison with SAP or PP.
Resumo:
This is the report of the first workshop on Incorporating In Vitro Alternative Methods for Developmental Neurotoxicity (DNT) Testing into International Hazard and Risk Assessment Strategies, held in Ispra, Italy, on 19-21 April 2005. The workshop was hosted by the European Centre for the Validation of Alternative Methods (ECVAM) and jointly organized by ECVAM, the European Chemical Industry Council, and the Johns Hopkins University Center for Alternatives to Animal Testing. The primary aim of the workshop was to identify and catalog potential methods that could be used to assess how data from in vitro alternative methods could help to predict and identify DNT hazards. Working groups focused on two different aspects: a) details on the science available in the field of DNT, including discussions on the models available to capture the critical DNT mechanisms and processes, and b) policy and strategy aspects to assess the integration of alternative methods in a regulatory framework. This report summarizes these discussions and details the recommendations and priorities for future work.
Resumo:
Purpose. - The purposes of this study were: i) to compare the physiological responses measured during a specific table tennis incremental test with the physiological responses measured during cycling, arm cranking, and treadmill running tests; and ii) to verify the accuracy of table tennis performance prediction based on the physiological responses from these tests.Methods. - Eleven national level male table tennis players participated in the study and undertook incremental tests using ergometers. Table tennis performance was defined as the ranking obtained during a simulated tournament between the participants.Results. - In general, peak values for physiological variables (e.g., (V) over dotO(2PEAK) and [La]PEAK) were significantly lower (P < 0.05) in the specific test (e.g., (V) over dotO(2PEAK) = 39.9 +/- 1.5 ml.kg(-1) per minute and [La]PEAK = 6.4 +/- 0.5 mmol.L-1) than during cycling (e.g., (V) over dotO(2PEAK) = 41.3 +/- 1.4 ml.kg(-1) per minute and [La]PEAK = 10.2 +/- 0.7 mmol.L-1) or running (e.g., (V) over dotO(2PEAK) = 43.9 +/- 1.5 ml.kg(-1) per minute and [La]PEAK = 10.0 +/- 0.7 mmol.L-1), but higher than during arm cranking (e.g., (V) over dotO(2PEAK) = 26.6 +/- 1.6 ml.kg(-1) per minute and [La]PEAK = 8.9 +/- 0.6 mmol.L-1). At respiratory compensation point intensity (RCP), only the variables measured on arm cranking were lower (P < 0.05) than on the other ergometers. Stepwise multiple regression analysis showed significant correlation between table tennis performance and lactate concentration ([La]) and also rate of perceived effort (RPE) at RCP during cycling (r = 0.89; P < 0.05).Conclusion. - In conclusion, the significant differences obtained between the specific and laboratory ergometers demonstrate the need to use a specific test to measure physiological parameters in table tennis and the physiological parameters measured, independent of the ergometer used, are unable to predict table tennis performance. (C) 2013 Elsevier Masson SAS. All rights reserved.
Resumo:
INTRODUCTION: Rivaroxaban (RXA) is licensed for prophylaxis of venous thromboembolism after major orthopaedic surgery of the lower limbs. Currently, no test to quantify RXA in plasma has been validated in an inter-laboratory setting. Our study had three aims: to assess i) the feasibility of RXA quantification with a commercial anti-FXa assay, ii) its accuracy and precision in an inter-laboratory setting, and iii) the influence of 10mg of RXA on routine coagulation tests. METHODS: The same chromogenic anti-FXa assay (Hyphen BioMed) was used in all participating laboratories. RXA calibrators and sets of blinded probes (aim ii.) were prepared in vitro by spiking normal plasma. The precise RXA content was assessed by high-pressure liquid chromatography-tandem mass spectrometry. For ex-vivo studies (aim iii), plasma samples from 20 healthy volunteers taken before and 2 - 3hours after ingestion of 10mg of RXA were analyzed by participating laboratories. RESULTS: RXA can be assayed chromogenically. Among the participating laboratories, the mean accuracy and the mean coefficient of variation for precision of RXA quantification were 7.0% and 8.8%, respectively. Mean RXA concentration was 114±43?g/L .RXA significantly altered prothrombin time, activated partial thromboplastin time, factor analysis for intrinsic and extrinsic factors. Determinations of thrombin time, fibrinogen, FXIII and D-Dimer levels were not affected. CONCLUSIONS: RXA plasma levels can be quantified accurately and precisely by a chromogenic anti-FXa assay on different coagulometers in different laboratories. Ingestion of 10mg RXA results in significant alterations of both PT- and aPTT-based coagulation assays.
Resumo:
BACKGROUND: Congestive heart failure (CHF) is a major public health problem. The use of B-type natriuretic peptide (BNP) tests shows promising diagnostic accuracy. Herein, we summarize the evidence on the accuracy of BNP tests in the diagnosis of CHF and compare the performance of rapid enzyme-linked immunosorbent assay (ELISA) and standard radioimmunosorbent assay (RIA) tests. METHODS: We searched electronic databases and the reference lists of included studies, and we contacted experts. Data were extracted on the study population, the type of test used, and methods. Receiver operating characteristic (ROC) plots and summary ROC curves were produced and negative likelihood ratios pooled. Random-effect meta-analysis and metaregression were used to combine data and explore sources of between-study heterogeneity. RESULTS: Nineteen studies describing 22 patient populations (9 ELISA and 13 RIA) and 9093 patients were included. The diagnosis of CHF was verified by echocardiography, radionuclide scan, or echocardiography combined with clinical criteria. The pooled negative likelihood ratio overall from random-effect meta-analysis was 0.18 (95% confidence interval [CI], 0.13-0.23). It was lower for the ELISA test (0.12; 95% CI, 0.09-0.16) than for the RIA test (0.23; 95% CI, 0.16-0.32). For a pretest probability of 20%, which is typical for patients with suspected CHF in primary care, a negative result of the ELISA test would produce a posttest probability of 2.9%; a negative RIA test, a posttest probability of 5.4%. CONCLUSIONS: The use of BNP tests to rule out CHF in primary care settings could reduce demand for echocardiography. The advantages of rapid ELISA tests need to be balanced against their higher cost.
Resumo:
Background: Data on thyroid involvement in primary antiphospholipid syndrome are scarce and inconclusive. Objectives: The aim of this study was to evaluate the frequency of thyroid dysfunction and antibodies in patients with primary antiphospholipid syndrome ( PAPS) and the association of these alterations with clinical and immunologic features. Methods: The study group included 50 PAPS patients (44 females) with a mean age of 39.7 +/- 11.5 years and mean disease duration of 77.3 +/- 63.5 months. Clinical data related to thyroid dysfunction and PAPS were obtained by chart review, patient interview, and clinical examination. Serum levels of TSH, free T4, antithyroglobulin antibody (TgAb), antithyroperoxidase antibody (TPOAb), thyroid receptor antibody (TRAb), and antiphospholipid autoantibodies were analyzed by standard techniques. Results: We found no hyperthyroidism among patients and found 22% (11 patients) with hypothyroidism in this sample. There were no differences between the latter patients and the euthyroid group about demographic findings, disease duration, thrombotic or obstetric events, and frequency of antiphospholipid antibodies as well as prevalence of thyroid auto antibodies. The prevalence of thyroid autoantibodies found was 6 patients (12%) with TgAb, 5 with TPOAb (10%), and 2 patients (4%) with both TgAb and TPOAb, comprising 18% of positivity of at least one of the auto antibodies. Conclusion: Hypothyroidism is present among 22% of PAPS patients and thyroid autoantibodies in 18% of them. These findings suggest a common pathophysiologic mechanism between antiphospholipid syndrome and autoimmune thyroid diseases.
Resumo:
This prospective study was carried out from October 2003 to December 2005 and involved a cohort of 946 individuals of both genders, aged 1-89 years, from an endemic area for American visceral leishmaniasis (AVL), in Para State, Brazil. The aim of the study was to analyze the dynamics of the clinical and immunological evolution of human Leishmania ( L.) infantum chagasi infection represented by the following clinical-immunological profiles: asymptomatic infection (AI); symptomatic infection (SI = AVL); subclinical oligosymptomatic infection (SOI); subclinical resistant infection (SRI); and indeterminate initial infection (III). Infection diagnosis was determined by the indirect fluorescent antibody test and leishmanin skin test. In total, 231 cases of infection were diagnosed: the AI profile was the most frequent (73.2%), followed by SRI (12.1%), III (9.9%), SI (2.6%) and SOI (2.2%). The major conclusion regarding evolution dynamics was that the III profile plays a pivotal role from which the cases evolve to either the resistant, SRI and AI, or susceptible, SOI and SI, profiles; only one of the 23 III cases evolved to SI, while most evolved to either SRI (nine cases) or SOI (five cases) and eight cases remained as III. (C) 2010 Royal Society of Tropical Medicine and Hygiene. Published by Elsevier Ltd. All rights reserved.
Resumo:
Considering the impact of cysticercosis on public health, especially the neurologic form of the disease, neurocysticercosis (NC), we studied the frequency of positivity of anti-Taenia solium cysticercus antibodies in serum samples from 1,863 inhabitants of Cássia dos Coqueiros, SP, a municipal district located 80 km from Ribeirão Preto, an area considered endemic for cysticercosis. The 1,863 samples were tested by enzyme linked immunosorbent assay (ELISA) using an antigenic extract from Taenia crassiceps vesicular fluid (Tcra). The reactive and inconclusive ELISA samples were tested by immunoblotting. Of the 459 samples submitted to immunoblotting, 40 were strongly immunoreactive to the immunodominant 18 and 14 kD peptides. Considering the use of immunoblotting as confirmatory due to its high specificity, the anti-cysticercus serum prevalence in this population was 2.1%.
Resumo:
INTRODUCTION: Prolonged survival of patients under HAART has resulted in new demands for assisted reproductive technologies. HIV serodiscordant couples wish to make use of assisted reproduction techniques in order to avoid viral transmission to the partner or to the newborn. It is therefore essential to test the effectiveness of techniques aimed at reducing HIV and HCV loads in infected semen using molecular biology tests. METHODS: After seminal analysis, semen samples from 20 coinfected patients were submitted to cell fractioning and isolation of motile spermatozoa by density gradient centrifugation and swim-up. HIV and HCV RNA detection tests were performed with RNA obtained from sperm, seminal plasma and total semen. RESULTS: In pre-washing semen, HIV RNA was detected in 100% of total semen samples, whereas HCV RNA was concomitantly amplified in only one specimen. Neither HIV nor HCV were detected either in the swim-up or in the post-washing semen fractions. CONCLUSIONS: Reduction of HIV and/or HCV shedding in semen by density gradient centrifugation followed by swim-up is an efficient method. These findings lead us to believe that, although semen is rarely found to contain HCV, semen processing is highly beneficial for HIV/HCV coinfected individuals.
Resumo:
As juntas adesivas são uma alternativa viável para substituir ligações comuns como as mecânicas ou soldadas, devido a diversas vantagens como a possibilidade de união de materiais de natureza diferente, maior leveza, menores custos inerentes ao fabrico e ainda prevenção da corrosão galvânica que pode ocorrer nas ligações entre dois materiais metálicos diferentes. A resistência de uma junta depende, para um determinado tipo de solicitação imposta, da distribuição de tensões no interior da junta. Por outro lado, a geometria das juntas, as propriedades mecânicas dos adesivos e os componentes a ligar vão influenciar a distribuição de tensões. O carregamento nas camadas adesivas de uma junta poderá induzir tensões de tração, compressão, corte, arrancamento ou clivagem, ou ainda uma combinação de duas ou mais destas componentes. O objetivo da presente dissertação é a caraterização completa de um adesivo estrutural de alta ductilidade recentemente lançado no mercado (SikaPower® -4720), para facilitar o projeto e otimização de juntas adesivas ligadas com o mesmo. São quatro os ensaios a realizar: ensaios à tração de provetes maciços (também denominados de bulk), ensaios ao corte com a geometria Thick Adherend Shear Test, ensaios Double-Cantilever Beam e ainda ensaios End-Notched Flexure. Com a realização dos ensaios referidos, são determinadas as propriedades essenciais à caraterização mecânica e de fratura do adesivo. Os resultados obtidos para cada ensaio resultaram em propriedades medidas com elevada repetibilidade, da mesma maneira que se revelaram de acordo com os dados disponibilizados pelo fabricante, sempre que estes estavam disponíveis.
Resumo:
Metalworking fluid-associated hypersensitivity pneumonitis (MWF-HP) is a pulmonary disease caused by inhaling microorganisms present in the metalworking fluids used in the industrial sector. Mycobacterium immunogenum is the main etiological agent. Among the clinical, radiological and biological tools used for diagnosis, serological tests are important. The aim of this study was to identify immunogenic proteins in M. immunogenum and to use recombinant antigens for serological diagnosis of MWF-HP. Immunogenic proteins were detected by two-dimensional Western blot and candidate proteins were identified by mass spectrometry. Recombinant antigens were expressed in Escherichia coli and tested by enzyme-linked immunosorbent assay (ELISA) with the sera of 14 subjects with MWF-HP and 12 asymptomatic controls exposed to M. immunogenum. From the 350 spots visualized by two-dimensional gel electrophoresis with M. immunogenum extract, 6 immunogenic proteins were selected to be expressed as recombinant antigens. Acyl-CoA dehydrogenase antigen allowed for the best discrimination of MWF-HP cases against controls with an area under the receiver operating characteristics (ROC) curve of 0.930 (95% CI=0.820-1), a sensitivity of 100% and a specificity of 83% for the optimum threshold. Other recombinant antigens correspond to acyl-CoA dehydrogenase FadE, cytosol aminopeptidase, dihydrolipoyl dehydrogenase, serine hydroxymethyltransferase and superoxide dismutase. This is the first time that recombinant antigens have been used for the serodiagnosis of hypersensitivity pneumonitis. The availability of recombinant antigens makes it possible to develop standardized serological tests which in turn could simplify diagnosis, thus making it less invasive.
Resumo:
BACKGROUND: Humanized murine models comprise a new tool to analyze novel therapeutic strategies for allergic diseases of the intestine.¦OBJECTIVE: In this study we developed a human PBMC-engrafted murine model of allergen-driven gut inflammation and analyzed the underlying immunologic mechanisms.¦METHODS: Nonobese diabetic (NOD)-scid-γc(-/-) mice were injected intraperitoneally with human PBMCs from allergic donors together with the respective allergen or not. Three weeks later, mice were challenged with the allergen orally or rectally, and gut inflammation was monitored with a high-resolution video miniendoscopic system, as well as histologically.¦RESULTS: Using the aeroallergens birch or grass pollen as model allergens and, for some donors, also hazelnut allergen, we show that allergen-specific human IgE in murine sera and allergen-specific proliferation and cytokine production of human CD4(+) T cells recovered from spleens after 3 weeks could only be measured in mice treated with PBMCs plus allergen. Importantly, these mice had the highest endoscopic scores evaluating translucent structure, granularity, fibrin, vascularity, and stool after oral or rectal allergen challenge and a strong histologic inflammation of the colon. Analyzing the underlying mechanisms, we demonstrate that allergen-associated colitis was dependent on IgE, human IgE receptor-expressing effector cells, and the mediators histamine and platelet-activating factor.¦CONCLUSION: These results demonstrate that allergic gut inflammation can be induced in human PBMC-engrafted mice, allowing the investigation of pathophysiologic mechanisms of allergic diseases of the intestine and evaluation of therapeutic interventions.
Resumo:
The serological cross-reactivity between different recently described Chlamydia-related organisms was determined. Mouse sera exhibited a strong reactivity against autologous antigen and closely related heterologous antigen but no cross-reactivity with distantly related species. These results are important to better interpret serological studies and assess the pathogenic role of these obligate intracellular bacteria.