904 resultados para Imaging systems in medicine


Relevância:

100.00% 100.00%

Publicador:

Resumo:

A new approach to mammographic mass detection is presented in this paper. Although different algorithms have been proposed for such a task, most of them are application dependent. In contrast, our approach makes use of a kindred topic in computer vision adapted to our particular problem. In this sense, we translate the eigenfaces approach for face detection/classification problems to a mass detection. Two different databases were used to show the robustness of the approach. The first one consisted on a set of 160 regions of interest (RoIs) extracted from the MIAS database, being 40 of them with confirmed masses and the rest normal tissue. The second set of RoIs was extracted from the DDSM database, and contained 196 RoIs containing masses and 392 with normal, but suspicious regions. Initial results demonstrate the feasibility of using such approach with performances comparable to other algorithms, with the advantage of being a more general, simple and cost-effective approach

Relevância:

100.00% 100.00%

Publicador:

Resumo:

L’objectiu d’aquest projecte és integrar a la plataforma Starviewer ( plataforma informàtica de processament i visualització d’imatges mèdiques creada fruit de la col•laboració del Laboratori de Gràfics i Imatge (GILab) de la Universitat de Girona i l’Institut de Diagnòstic per la Imatge (IDI) de l’hospital Dr. Josep Trueta de Girona) per donar suport al diagnòstic un entorn de suport a la inserció de pròtesis, que permeti automatitzar al màxim les operacions que actualment es realitzen de forma manual. Hem de tenir en compte que, tot i que, la imatge més usada pel radiòleg es la radiografia (Rx) també treballa amb tomografia computada (TAC). El TAC dona una visió 3D de l’organisme, mentre que la Rx és 2D

Relevância:

100.00% 100.00%

Publicador:

Resumo:

L’objectiu d’aquest projecte és ampliar la plataforma Starviewer integrant els mòduls necessaris per donar suport al diagnòstic de l’estenosi de caròtida permetent interpretar de forma més fàcil les imatges Angiografia per Ressonància Magnètica (ARM). La plataforma Starviewer és un entorn informàtic que integra funcionalitats bàsiques i avançades pel processament i la visualització d’imatges mèdiques. Està desenvolupat pel Grup d’Informàtica Gràfica de la Universitat de Girona i l’Institut de Diagnòstic per la Imatge (IDI) de l’hospital Dr. Josep Trueta. Una de les limitacions de la plataforma és el no suportar el tractament de lesions del sistema vascular. Per això ens proposem a corregir-ho i ampliar les seves extensions per a poder diagnosticar l’estenosi de caròtida

Relevância:

100.00% 100.00%

Publicador:

Resumo:

L’objectiu d’aquest projecte es dissenyar i implementar un entorn de suport al diagnòstic dels aneurismes. Aquest entorn s’haurà d’integrar en la plataforma Starviewer. La plataforma Starviewer és un entorn de processament i visualització de dades mèdiques desenvolupat conjuntament entre el Laboratori de Gràfics i Imatge de la UdG i l’ Institut de Diagnòstic per la Imatge de l’Hospital Josep Trueta de Girona. Aquesta plataforma ofereix les funcionalitats bàsiques per diagnosticar a partir d’imatges. Tot i les funcionalitats de la plataforma, en la versió actual no es suporta el processament avançat d’imatge d’angiografia. En aquest projecte ens proposem ampliar aquesta plataforma integrant els mòduls necessaris que permetin el processament d’angiografies usades en el diagnòstic dels aneurismes

Relevância:

100.00% 100.00%

Publicador:

Resumo:

One of the key aspects in 3D-image registration is the computation of the joint intensity histogram. We propose a new approach to compute this histogram using uniformly distributed random lines to sample stochastically the overlapping volume between two 3D-images. The intensity values are captured from the lines at evenly spaced positions, taking an initial random offset different for each line. This method provides us with an accurate, robust and fast mutual information-based registration. The interpolation effects are drastically reduced, due to the stochastic nature of the line generation, and the alignment process is also accelerated. The results obtained show a better performance of the introduced method than the classic computation of the joint histogram

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Techniques for the coherent generation and detection of electromagnetic radiation in the far infrared, or terahertz, region of the electromagnetic spectrum have recently developed rapidly and may soon be applied for in vivo medical imaging. Both continuous wave and pulsed imaging systems are under development, with terahertz pulsed imaging being the more common method. Typically a pump and probe technique is used, with picosecond pulses of terahertz radiation generated from femtosecond infrared laser pulses, using an antenna or nonlinear crystal. After interaction with the subject either by transmission or reflection, coherent detection is achieved when the terahertz beam is combined with the probe laser beam. Raster scanning of the subject leads to an image data set comprising a time series representing the pulse at each pixel. A set of parametric images may be calculated, mapping the values of various parameters calculated from the shape of the pulses. A safety analysis has been performed, based on current guidelines for skin exposure to radiation of wavelengths 2.6 µm–20 mm (15 GHz–115 THz), to determine the maximum permissible exposure (MPE) for such a terahertz imaging system. The international guidelines for this range of wavelengths are drawn from two U.S. standards documents. The method for this analysis was taken from the American National Standard for the Safe Use of Lasers (ANSI Z136.1), and to ensure a conservative analysis, parameters were drawn from both this standard and from the IEEE Standard for Safety Levels with Respect to Human Exposure to Radio Frequency Electromagnetic Fields (C95.1). The calculated maximum permissible average beam power was 3 mW, indicating that typical terahertz imaging systems are safe according to the current guidelines. Further developments may however result in systems that will exceed the calculated limit. Furthermore, the published MPEs for pulsed exposures are based on measurements at shorter wavelengths and with pulses of longer duration than those used in terahertz pulsed imaging systems, so the results should be treated with caution.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Liposomes were discovered about 40 years ago by A. Bangham and since then they became very versatile tools in biology, biochemistry and medicine. Liposomes are the smallest artificial vesicles of spherical shape that can be produced from natural untoxic phospholipids and cholesterol. Liposome vesicles can be used as drug carriers and become loaded with a great variety of molecules, such as small drug molecules, proteins, nucleotides and even plasmids. Due to the variability of liposomal compositions they can be used for a large number of applications. In this thesis the β-adrenoceptor antagonists propranolol, metoprolol, atenolol and pindolol, glucose, 18F-Fluorodeoxyglucose (FDG) and Er-DTPA were used for encapsulation in liposomes, characterization and in vitro release studies. Multilamellar vesicles (MLV), large unilamellar vesicles (LUV) and smaller unilamellar vesicles (SUV) were prepared using one of the following lipids: 1,2-Dimyristoyl-sn-Glycero-3-Phosphocholine (DMPC), 1,2-Distearoyl-sn-Glycero-3-Phosphocholine (DSPC), Phospholipone 90H (Ph90H) or a mixture of DSPC and DMPC (1:1). The freeze thawing method was used for preparation of liposomes because it has three advantages (1) avoiding the use of chloroform, which is used in other methods and causes toxicity (2) it is a simple method and (3) it gives high entrapping efficiency. The percentage of entrapping efficiencies (EE) was different depending on the type and phase transition temperature (Tc) of the lipid used. The average particle size and particle size distribution of the prepared liposomes were determined using both dynamic light scattering (DLS) and laser diffraction analyzer (LDA). The average particle size of the prepared liposomes differs according to both liposomal type and lipid type. Dispersion and dialysis techniques were used for the study of the in vitro release of β-adrenoceptor antagonists. The in vitro release rate of β-adrenoceptor antagonists was increased from MLV to LUV to SUV. Regarding the lipid type, β-adrenoceptor antagonists exhibited different in vitro release pattern from one lipid to another. Two different concentrations (50 and 100mg/ml) of Ph90H were used for studying the effect of lipid concentration on the in vitro release of β-adrenoceptor antagonists. It was found that liposomes made from 50 mg/ml Ph90H exhibited higher release rates than liposomes made at 100 mg/ml Ph90H. Also glucose was encapsulated in MLV, LUV and SUV using 1,2-Dimyristoyl-sn-Glycero-3-Phosphocholine (DMPC), 1,2-Distearoyl-sn-Glycero-3-Phosphocholine (DSPC), Phospholipone 90H (Ph90H), soybean lipid (Syb) or a mixture of DSPC and DMPC (1:1). The average particle size and size distribution were determined using laser diffraction analysis. It was found that both EE and average particle size differ depending on both lipid and liposomal types. The in vitro release of glucose from different types of liposomes was performed using a dispersion method. It was found that the in vitro release of glucose from different liposomes is dependent on the lipid type. 18F-FDG was encapsulated in MLV 1,2-Dimyristoyl-sn-Glycero-3-Phosphocholine (DMPC), 1,2-Distearoyl-sn-Glycero-3-Phosphocholine (DSPC), Phospholipone 90H (Ph90H), soybean lipid (Syb) or a mixture of DSPC and DMPC (1:1). FDG-containing LUV and SUV were prepared using Ph90H lipid. The in vitro release of FDG from the different types of lipids was accomplished using a dispersion method. Results similar to that of glucose release were obtained. In vivo imaging of FDG in both uncapsulated FDG and FDG-containing MLV was performed in the brain and the whole body of rats using PET scanner. It was found that the release of FDG from FDG-containing MLV was sustained. In vitro-In vivo correlation was studied using the in vitro release data of FDG from liposomes and in vivo absorption data of FDG from injected liposomes using microPET. Erbium, which is a lanthanide metal, was used as a chelate with DTPA for encapsulation in SUV liposomes for the indirect radiation therapy of cancer. The liposomes were prepared using three different concentrations of soybean lipid (30, 50 and 70 mg/ml). The stability of Er-DTPA SUV liposomes was carried out by storage of the prepared liposomes at three different temperatures (4, 25 and 37 °C). It was found that the release of Er-DTPA complex is temperature dependent, the higher the temperature, the higher the release. There was an inverse relationship between the release of the Er-DTPA complex and the concentration of lipid.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Incidental findings on low-dose CT images obtained during hybrid imaging are an increasing phenomenon as CT technology advances. Understanding the diagnostic value of incidental findings along with the technical limitations is important when reporting image results and recommending follow-up, which may result in an additional radiation dose from further diagnostic imaging and an increase in patient anxiety. This study assessed lesions incidentally detected on CT images acquired for attenuation correction on two SPECT/CT systems. Methods: An anthropomorphic chest phantom containing simulated lesions of varying size and density was imaged on an Infinia Hawkeye 4 and a Symbia T6 using the low-dose CT settings applied for attenuation correction acquisitions in myocardial perfusion imaging. Twenty-two interpreters assessed 46 images from each SPECT/CT system (15 normal images and 31 abnormal images; 41 lesions). Data were evaluated using a jackknife alternative free-response receiver-operating-characteristic analysis (JAFROC). Results: JAFROC analysis showed a significant difference (P < 0.0001) in lesion detection, with the figures of merit being 0.599 (95% confidence interval, 0.568, 0.631) and 0.810 (95% confidence interval, 0.781, 0.839) for the Infinia Hawkeye 4 and Symbia T6, respectively. Lesion detection on the Infinia Hawkeye 4 was generally limited to larger, higher-density lesions. The Symbia T6 allowed improved detection rates for midsized lesions and some lower-density lesions. However, interpreters struggled to detect small (5 mm) lesions on both image sets, irrespective of density. Conclusion: Lesion detection is more reliable on low-dose CT images from the Symbia T6 than from the Infinia Hawkeye 4. This phantom-based study gives an indication of potential lesion detection in the clinical context as shown by two commonly used SPECT/CT systems, which may assist the clinician in determining whether further diagnostic imaging is justified.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

We apply the transformation optical technique to modify or improve conventional refractive and gradient index optical imaging devices. In particular, when it is known that a detector will terminate the paths of rays over some surface, more freedom is available in the transformation approach, since the wave behavior over a large portion of the domain becomes unimportant. For the analyzed configurations, quasi-conformal and conformal coordinate transformations can be used, leading to simplified constitutive parameter distributions that, in some cases, can be realized with isotropic index; index-only media can be low-loss and have broad bandwidth. We apply a coordinate transformation to flatten a Maxwell fish-eye lens, forming a near-perfect relay lens; and also flatten the focal surface associated with a conventional refractive lens, such that the system exhibits an ultra-wide field-of-view with reduced aberration.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The absence of Dam in Salmonella enterica serovar Enteritidis causes a defect in lipopolysaccharide (LPS) pattern associated to a reduced expression of wzz gene. Wzz is the chain length regulator of the LPS O-antigen. Here we investigated whether Dam regulates wzz gene expression through its two known regulators, PmrA and RcsB. Thus, the expression of rcsB and pmrA was monitored by quantitative real-time RT-PCR and Western blotting using fusions with 3×FLAG tag in wild type (wt) and dam strains of S. Enteritidis. Dam regulated the expression of both rcsB and pmrA genes; nevertheless, the defect in LPS pattern was only related to a diminished expression of RcsB. Interestingly, regulation of wzz in serovar Enteritidis differed from that reported earlier for serovar Typhimurium; RcsB induces wzz expression in both serovars, whereas PmrA induces wzz in S. Typhimurium but represses it in serovar Enteritidis. Moreover, we found that in S. Enteritidis there is an interaction between both wzz regulators: RcsB stimulates the expression of pmrA and PmrA represses the expression of rcsB. Our results would be an example of differential regulation of orthologous genes expression, providing differences in phenotypic traits between closely related bacterial serovars.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

BACKGROUND: Recommendations for statin use for primary prevention of coronary heart disease (CHD) are based on estimation of the 10- year CHD risk. We compared the 10-year CHD risk assessments and eligibility percentages for statin therapy using three scoring algorithms currently used in Europe. METHODS: We studied 5683 women and men, aged 35-75, without overt cardiovascular disease (CVD), in a population-based study in Switzerland. We compared the 10-year CHD risk using three scoring schemes, i.e., the Framingham risk score (FRS) from the U.S. National Cholesterol Education Program's Adult Treatment Panel III (ATP III), the PROCAM scoring scheme from the International Atherosclerosis Society (IAS), and the European risk SCORE for low-risk countries, without and with extrapolation to 60 years as recommended by the European Society of Cardiology guidelines (ESC). With FRS and PROCAM, high-risk was defined as a 10- year risk of fatal or non-fatal CHD>20% and a 10-year risk of fatal CVD≥5% with SCORE. We compared the proportions of high-risk participants and eligibility for statin use according to these three schemes. For each guideline, we estimated the impact of increased statin use from current partial compliance to full compliance on potential CHD deaths averted over 10 years, using a success proportion of 27% for statins. RESULTS: Participants classified at high-risk (both genders) were 5.8% according to FRS and 3.0% to the PROCAM, whereas the European risk SCORE classified 12.5% at high-risk (15.4% with extrapolation to 60 years). For the primary prevention of CHD, 18.5% of participants were eligible for statin therapy using ATP III, 16.6% using IAS, and 10.3% using ESC (13.0% with extrapolation) because ESC guidelines recommend statin therapy only in high-risk subjects. In comparison with IAS, agreement to identify eligible adults for statins was good with ATP III, but moderate with ESC. Using a population perspective, a full compliance with ATP III guidelines would reduce up to 17.9% of the 24′ 310 CHD deaths expected over 10 years in Switzerland, 17.3% with IAS and 10.8% with ESC (11.5% with extrapolation). CONCLUSIONS: Full compliance with guidelines for statin therapy would result in substantial health benefits, but proportions of high-risk adults and eligible adults for statin use varied substantially depending on the scoring systems and corresponding guidelines used for estimating CHD risk in Europe.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Visual control of locomotion is essential for most mammals and requires coordination between perceptual processes and action systems. Previous research on the neural systems engaged by self-motion has focused on heading perception, which is only one perceptual subcomponent. For effective steering, it is necessary to perceive an appropriate future path and then bring about the required change to heading. Using function magnetic resonance imaging in humans, we reveal a role for the parietal eye fields (PEFs) in directing spatially selective processes relating to future path information. A parietal area close to PEFs appears to be specialized for processing the future path information itself. Furthermore, a separate parietal area responds to visual position error signals, which occur when steering adjustments are imprecise. A network of three areas, the cerebellum, the supplementary eye fields, and dorsal premotor cortex, was found to be involved in generating appropriate motor responses for steering adjustments. This may reflect the demands of integrating visual inputs with the output response for the control device.