975 resultados para Imaging diagnostic agents


Relevância:

80.00% 80.00%

Publicador:

Resumo:

The diagnosis of pancreatic masses represents a great challenger for imaging studies. However the occurrence of pancreatic masses have been reported more frequently in the last years due to advances in imaging diagnostic methods. During the last decade, the surgical approach of pancreatic masses was limited to an attempt of establishing histological diagnosis, staging and evaluation of resection of these masses. Recently, the approach and staging of pancreatic masses was facilitated by sophisticated methods of diagnosis, especially, ultrasound, dynamic computerized tomography, magnetic resonance imaging (/RM), angiography, endoscopic retrograde cholangiopancreatography (CPRE), endoscopic ultrasound, laparoscopy and biochemical tumors markers. The present paper reports a case of a pancreatic mass due to foreign body in which the imaging study helped to determine out this rare etiological agent that has not been previouly described in literature.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The application of nanotechnology to medicine can provide important benefits, especially in oncology, a fact that has resulted in the emergence of a new field called Nanooncology. Nanoparticles can be engineered to incorporate a wide variety of chemotherapeutic or diagnostic agents. A nanocapsule is a vesicular system that exhibits a typical core-shell structure in which active molecules are confined to a reservoir or within a cavity that is surrounded by a polymer membrane or coating. Delivery systems based on nanocapsules are usually transported to a targeted tumor site and then release their contents upon change in environmental conditions. An effective delivery of the therapeutic agent to the tumor site and to the infiltrating tumor cells is difficult to achieve in many cancer treatments. Therefore, new devices are being developed to facilitate intratumoral distribution, to protect the active agent from premature degradation and to allow its sustained and controlled release. This review focuses on recent studies on the use of nanocapsules for cancer therapy and diagnosis.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

A ruptura do ligamento cruzado cranial é uma das causas mais comuns de claudicação do membro pélvico de cães. A radiografia e a ultrassonografia são métodos de diagnóstico frequentemente utilizados na rotina clínica de pequenos animais, porém a tomografia computadorizada é uma modalidade de imagem ainda pouco estudada para avaliar a articulação do joelho de cães. O presente trabalho teve por objetivo avaliar a contribuição do contraste negativo na artrografia tomográfica do joelho normal de cães, para visibilizar as estruturas intra-articulares e padronizar o uso desse contraste na articulação. Foram utilizados 24 membros pélvicos de cães de raças variadas, selecionados pela ausência de histórico de doença articular prévia do joelho e por apresentarem exames radiográficos, ultrassonográficos e macroscópicos normais. O experimento foi delineado em dois grupos, sendo o grupo I constituído de animais com peso até 20 kg e grupo II acima de 20 kg. Foram feitos cortes tomográficos com o membro flexionado e estendido. A quantidade média de ar empregada para a distensão da cápsula articular foi de 49 ml para o Grupo I e de 81 ml para o Grupo II. Utilizou-se um tubo de látex na porção distal à articulação do joelho para reduzir o escape de ar pelo tendão extensor digital profundo, que possui comunicação intra-articular. Foi possível visibilizar pela imagem tomográfica, em todas as articulações, as seguintes estruturas: ligamento cruzado cranial e caudal, meniscos medial e lateral, ligamento patelar, ligamentos colaterais e cápsula articular. Desta forma, o contraste negativo se mostrou uma alternativa eficaz para auxiliar a identificação das estruturas anatômicas do joelho na artrografia tomográfica.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Pós-graduação em Cirurgia Veterinária - FCAV

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The computed tomography, devised by Godfrey Hounsfield and Allan Cormack, is in its fourth decade of the clinical use and has presented to be a very useful tool in the diagnosis of several pathologies. For this reason, its use is increasing each day, due to technological progress since its creation. Due to be more and more utilized, the equipment must be in good operating conditions, because it is subject to variance and wearing, damage the quality of diagnosis. To evaluate whether the performance of the scanner remains constant along the time and the dose received by the patient is within the desired limits, periodic tests of quality control must be performed. For this subject, the regulation 453 (June 01, 1998) was created, which determines the need of the implementation of a program for quality assurance (PGQ), where, in addition to the tests of quality control, are established the necessary measurements for the proper functioning of the equipment, generating a trustworthy diagnosis, reducing the dose for the patient and the costs. In this document, are presented tests of quality control carried out in hospitals of the city of Sao Paulo carried out together with the Technical Section of Applications by Imaging Diagnostic (STADI) of the Institute of Electrotechnics and Energy of the University of São Paulo (IEE/USP)

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The diagnosis of various diseases has become more accessible and accurate with the rapid development of imaging modalities aiming to assist in medical diagnosis, and thereby in veterinary medicine. Different diagnostic imaging modalities such as ultrasonography, computed tomography, magnetic resonance imaging and scintigraphy can be performed to obtain information about thyroid diseases, each one with advantages and disadvantages, depending on the thyroid disease in question. Diagnostic imaging is a tool that not only assists in the diagnosis, but also helps treatment and assessment of prognosis of thyroid diseases. The aim of this article is to discuss the limitations and benefits of each diagnostic imaging modality available in the veterinary medical field, and also to present the newest diagnostic imaging modalities in order to maximize and make more accurate diagnosis of thyroid diseases.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Untersuchungen zur stereokontrollierten Synthese von 3-Mercaptolysinderivaten: 3-Mercaptolysin und Peptide mit einer 3-Mercaptolysin-Einheit sind als Liganden für Nukleardiagnostika in der Kontrastmittelforschung von großem Interesse. Für das Screening Gewebe-selektiver Diagnostika sollten Mercaptolysinderivate, die sich für den Einbau in Peptide eignen, stereokontrolliert aufgebaut werden. Als Grundlage wurde im Rahmen dieser Arbeit eine sehr effiziente Synthese von Methoxymethyl-(4-oxo-butyl)-carbaminsäure-tert-butylester aus Pent-4-en-1-ol entwickelt. Nach Olefinierung des Aldehyds konnten Auxiliar-substituierte 6-Amino-hexensäure-derivate in guten Ausbeuten erhalten werden. Diese bildeten die Startmaterialien für auxiliargesteuerte Aziridinierungen mit anschließender Ringöffnung durch Schwefel-Nukleophile. Zudem wurden Azidierungen an Auxiliar-bewehrten Substraten, Michael-Additionen von Schwefel-Nukleophilen an Dehydroaminosäuren und viele weitere Reaktionen untersucht. Es galt dabei auf patentrechtlich geschützte Reaktionen zu verzichten, weil die Produkte ggf. in großem Maßstab kommerziell genutzt werden sollen. Dabei konnten alle vier stereoisomeren 2-Acetylamino-6-(tert-butoxycarbonyl-methoxymethyl-amino)-3-(4-methoxy-benzylsulfanyl)-hexansäurementhylester in guter Ausbeute synthetisiert werden. Nach Herstellung größerer Mengen der entsprechenden am Schwefelatom ungeschützten N-Fmoc-Aminosäurederivate sollen alle vier Stereoisomere in Peptide eingebaut und auf ihre Eignung als Liganden in Nukleardiagnostika untersucht werden. Untersuchungen zur Synthese neuartiger Ansa-Steroide: Über die Synthese von Ansa-Seco-Steroiden mittels eine Kaskade von intermolekularer Diels-Alder-Reaktion und anschließender Retro-Diels-Alder-Reaktion an 5,6,7,8-Tetradehydrosteroiden wurde erstmals 1986 von E. Winterfeldt et al. berichtet. Die damit eröffnete Möglichkeit eines völlig neuen Zugangs zu pharmakologisch interessanten Makrolid-Substraten konnte aber bislang nicht effektiv genutzt werden, weil insbesondere im Zusammenhang mit der Diels-Alder-Reaktion erhebliche präparative Probleme auftraten: Brauchbare Reaktivität nur bei sehr wenigen Dienophilen, Regioselektivitätsprobleme, etc. Hier galt es zu untersuchen, inwiefern sich diese Probleme durch die intramolekulare Reaktionsführung der Cycloaddition unterdrücken lassen können. Für die intramolekulare Diels-Alder-Reaktion zwischen der 5,7-Dien-Einheit des Steroids und einer an das Substrat gebundenen Dienophil-Einheit ist die Möglichkeit einer günstigen Anordnung der beiden Reaktanden-Gruppen entscheidend. Dafür wurden umfangreiche Untersuchungen zur alpha-konfigurierten Anbindung eines Dienophils in die 3-Position an 3-Hydroxy-5,6,7,8-Tetradehydrosteroiden durchgeführt: Mitsunobu-Reaktionen, Oxidations-Reduktions-Sequenzen, Oxidations-Ketalisierungs-Sequenzen, etc. Hierbei wurden zahlreiche neue Steroide synthetisiert. Es gelang jedoch nicht, 5,6,7,8-Tetradehydrosteroide mit axial in Position 3 eingebundenen Dienophilen in präparativ nutzbaren Mengen zu synthetisieren. Bei der Untersuchung intermolekularer Diels-Alder-Reaktionen zwischen Ergosterol und Brommaleinsäureanhydrid wurde vorzugsweise die Bildung der Addukte des 7,8,14,15-Tetradehydroisomers des Ergosterols beobachtet.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Descriptions of therapeutic, prophylactic and diagnostic agents evaluated by the Council on Drugs.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

A multiagent diagnostic system implemented in a Protege-JADE-JESS environment interfaced with a dynamic simulator and database services is described in this paper. The proposed system architecture enables the use of a combination of diagnostic methods from heterogeneous knowledge sources. The process ontology and the process agents are designed based on the structure of the process system, while the diagnostic agents implement the applied diagnostic methods. A specific completeness coordinator agent is implemented to coordinate the diagnostic agents based on different methods. The system is demonstrated on a case study for diagnosis of faults in a granulation process based on HAZOP and FMEA analysis.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Magnetic resonance cholangiography (MRC) relies on the strong T-2 signal from stationary liquids, in this case bile, to generate images. No contrast agents are required, and the failure rate and risk of serious complications is lower than with endoscopic retrograde cholangiopancreatography (ERCP). Data from MRC can be summated to produce an image much like the cholangiogram obtained by using ERCP. In addition, MRC and conventional MRI can provide information about the biliary and other anatomy above and below a biliary obstruction. This provides information for therapeutic intervention that is probably most useful for hilar and intrahepatic biliary obstruction. Magnetic resonance cholangiography appears to be similar to ERCP with respect to sensitivity and specificity in detecting lesions causing biliary obstruction, and in the diagnosis of choledocholithiasis. It is also suited to the assessment of biliary anatomy (including the assessment of surgical bile-duct injuries) and intrahepatic biliary pathology. However, ERCP can be therapeutic as well as diagnostic, and MRC should be limited to situations where intervention is unlikely, where intrahepatic or hilar pathology is suspected, to delineate the biliary anatomy prior to other interventions, or after failed or inadequate ERCP. Magnetic resonance angiography (MRA) relies on the properties of flowing liquids to generate images. It is particularly suited to assessment of the hepatic vasculature and appears as good as conventional angiography. It has been shown to be useful in delineating vascular anatomy prior to liver transplantation or insertion of a transjugular intrahepatic portasystemic shunt. Magnetic resonance angiography may also be useful in predicting subsequent variceal haemorrhage in patients with oesophageal varices. (C) 2000 Blackwell Science Asia Pty Ltd.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Esta tese pretende contribuir para o estudo e análise dos factores relacionados com as técnicas de aquisição de imagens radiológicas digitais, a qualidade diagnóstica e a gestão da dose de radiação em sistema de radiologia digital. A metodologia encontra-se organizada em duas componentes. A componente observacional, baseada num desenho do estudo de natureza retrospectiva e transversal. Os dados recolhidos a partir de sistemas CR e DR permitiram a avaliação dos parâmetros técnicos de exposição utilizados em radiologia digital, a avaliação da dose absorvida e o índice de exposição no detector. No contexto desta classificação metodológica (retrospectiva e transversal), também foi possível desenvolver estudos da qualidade diagnóstica em sistemas digitais: estudos de observadores a partir de imagens arquivadas no sistema PACS. A componente experimental da tese baseou-se na realização de experiências em fantomas para avaliar a relação entre dose e qualidade de imagem. As experiências efectuadas permitiram caracterizar as propriedades físicas dos sistemas de radiologia digital, através da manipulação das variáveis relacionadas com os parâmetros de exposição e a avaliação da influência destas na dose e na qualidade da imagem. Utilizando um fantoma contraste de detalhe, fantomas antropomórficos e um fantoma de osso animal, foi possível objectivar medidas de quantificação da qualidade diagnóstica e medidas de detectabilidade de objectos. Da investigação efectuada, foi possível salientar algumas conclusões. As medidas quantitativas referentes à performance dos detectores são a base do processo de optimização, permitindo a medição e a determinação dos parâmetros físicos dos sistemas de radiologia digital. Os parâmetros de exposição utilizados na prática clínica mostram que a prática não está em conformidade com o referencial Europeu. Verifica-se a necessidade de avaliar, melhorar e implementar um padrão de referência para o processo de optimização, através de novos referenciais de boa prática ajustados aos sistemas digitais. Os parâmetros de exposição influenciam a dose no paciente, mas a percepção da qualidade de imagem digital não parece afectada com a variação da exposição. Os estudos que se realizaram envolvendo tanto imagens de fantomas como imagens de pacientes mostram que a sobreexposição é um risco potencial em radiologia digital. A avaliação da qualidade diagnóstica das imagens mostrou que com a variação da exposição não se observou degradação substancial da qualidade das imagens quando a redução de dose é efectuada. Propõe-se o estudo e a implementação de novos níveis de referência de diagnóstico ajustados aos sistemas de radiologia digital. Como contributo da tese, é proposto um modelo (STDI) para a optimização de sistemas de radiologia digital.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

The formation of amyloid structures is a neuropathological feature that characterizes several neurodegenerative disorders, such as Alzheimer´s and Parkinson´s disease. Up to now, the definitive diagnosis of these diseases can only be accomplished by immunostaining of post mortem brain tissues with dyes such Thioflavin T and congo red. Aiming at early in vivo diagnosis of Alzheimer´s disease (AD), several amyloid-avid radioprobes have been developed for b-amyloid imaging by positron emission tomography (PET) and single-photon emission computed tomography (SPECT). The aim of this paper is to present a perspective of the available amyloid imaging agents, special those that have been selected for clinical trials and are at the different stages of the US Food and Drugs Administration (FDA) approval.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Coronary magnetic resonance angiography (MRA) is a technique aimed at establishing a noninvasive test for the assessment of significant coronary stenoses. There are certain boundary conditions that have hampered the clinical success of coronary MRA and coronary vessel wall imaging. Recent advances in hardware and software allow for consistent visualization of the proximal and mid portions of the native coronary arteries. Current research focuses on the use of intravascular MR contrast agents and black blood coronary angiography. One common goal is to create a noninvasive test which might allow for screening for major proximal and mid coronary artery disease. These novel approaches will represent a major step forward in diagnostic cardiology.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Originally invented for topographic imaging, atomic force microscopy (AFM) has evolved into a multifunctional biological toolkit, enabling to measure structural and functional details of cells and molecules. Its versatility and the large scope of information it can yield make it an invaluable tool in any biologically oriented laboratory, where researchers need to perform characterizations of living samples as well as single molecules in quasi-physiological conditions and with nanoscale resolution. In the last 20 years, AFM has revolutionized the characterization of microbial cells by allowing a better understanding of their cell wall and of the mechanism of action of drugs and by becoming itself a powerful diagnostic tool to study bacteria. Indeed, AFM is much more than a high-resolution microscopy technique. It can reconstruct force maps that can be used to explore the nanomechanical properties of microorganisms and probe at the same time the morphological and mechanical modifications induced by external stimuli. Furthermore it can be used to map chemical species or specific receptors with nanometric resolution directly on the membranes of living organisms. In summary, AFM offers new capabilities and a more in-depth insight in the structure and mechanics of biological specimens with an unrivaled spatial and force resolution. Its application to the study of bacteria is extremely significant since it has already delivered important information on the metabolism of these small microorganisms and, through new and exciting technical developments, will shed more light on the real-time interaction of antimicrobial agents and bacteria.