990 resultados para INTRAOCULAR-PRESSURE FLUCTUATIONS
Resumo:
Background: Intraocular pressure (IOP) is the pressure inside the eye that helps to maintain the integrity and the suitable form of the ocular globe. Precise and accurate measures of IOP are needed for the diagnosis as well as follow-up of glaucoma. In daily clinical practice, Goldmann applanation tonometer (GAT) and Non-contact tonometer (NCT) are the most common devices for measuring IOP. A close agreement between these methods has been showed, particularly in normotensive patients and a poor agreement, especially when IOP levels are above the normal range. Ophthalmologists have noticed a poor agreement between NCT and GAT, observing that by using NCT and after comparing with GAT, there is an overestimation of IOP readings, and particularly it occurs when the eyes are tearful. Previous studies investigate the effect of tears in Non-contact tonometer readings by the instillation of artificial tears, concluding in one of the studies that the variation was less than 1mmHg and not clinically significant, in contrast with another study which the increases were sadistically significant. Tear menisci are a thin strip of tear fluid located between the bulbar conjunctiva and the eyelid margins. We think that the overestimation of IOP readings using NCT could be due to the presence of a higher volume of tear in the lower tear meniscus which might cause an optical interference in the optoelectronic applanation monitoring system of this deviceObjectives: To research the influence of a certain volume of fluid in the lower tear meniscus on IOP measurements using the NCT in healthy eyes. Moreover, to investigate the agreement between IOP readings obtained by NCT and GAT in the presence and absence of this volume of fluidMethods: The study design will be transversal for diagnostic tests of repeated measures. We will study patients with no ocular pathology and IOP<21mmHg. It will consist in the measurement of IOP using NCT before and after the instillation of COLIRCUSÍ FLUOTEST, used as a volume of fluid in the lower tear meniscus, to observe if there will be differences using the paired t-test. Moreover, we will take IOP measures by GAT in order to know the agreement between these methods after and before the application of these eyedrops, using the ICC (intraclass correlation coefficient) and the Bland-Altmann method
Resumo:
This study aimed to compare the normal intraocular pressure (IOP) and tear secretion, by means of applanation tonometry and the Schirmer tear test-1 (STT-1), in goats of the Saanen breed with different ages, and at different time points. Thirty six goats, free of ocular abnormalities, were grouped into three different age categories (n=12), animals with 45, 180 and 549 days of age. STT-1 and IOP measurements were carried out always at 9:00am and 7:00pm, during three consecutive days. Results were evaluated statistically (P<0.05). Regarding the time of the day, overall IOP values were significantly lower at 7:00 pm (P<0.001) in individuals with 45 days of age; whereas STT-1 values were significantly higher at 7:00pm (P=0.004) in goats with 549 days of age. Considering the sum of three days, both parameters were significantly lower in individuals with 45 days of age (P<0.001). Intraocular pressure and tear secretion values increase until 180 days of age in the Saanen breed of goats.
Resumo:
The purpose of this study was to establish reference values for selected ophthalmic diagnostic tests in New Zealand rabbits (Oryctolagus cuniculus). A total of 22 adult male rabbits were used. The ophthalmic tests included evaluation of tear production with Schirmer tear test 1(STT1) and Endodontic absorbent paper point tear test (EAPPTT) using two different commercial brand materials. Applanation tonometry, Culture of the conjunctival bacterial flora, , conjunctival cytology and conjunctival histology were also performed. Mean (±SD) for STT1, EAPPTTa, EAPPTTb and IOP was 7.27±2.51mm/min, 12.43±1.69mm/min, 15.24±2.07mm/min, 12.89±2.80mm Hg, respectively. Staphylococcus epidermidis, Staphylococcus sp. and Bacillus sp. were predominant. The cytological evaluation revealed the presence columnar epithelial cells, superficial squamous keratinized cells, lymphocytes, heterophils, red blood cells, mucus and bacteria. The histological analysis revealed a stratified epithelium, characterized by the presence of columnar epithelial cells with a large number of goblet cells. The reported data can be used for therapeutic or experimental purposes.
Resumo:
The effects of exercise and water replacement on intraocular pressure (IOP) have not been well established. Furthermore, it is not known whether the temperature of the fluid ingested influences the IOP response. In the present study we determined the effect of water ingestion at three temperatures (10, 24 and 38ºC; 600 ml 15 min before and 240 ml 15, 30 and 45 min after the beginning of each experimental session) on the IOP of six healthy male volunteers (age = 24.0 ± 3.5 years, weight = 67.0 ± 4.8 kg, peak oxygen uptake (VO2peak) = 47.8 ± 9.1 ml kg-1 min-1). The subjects exercised until exhaustion on a cycle ergometer at a 60% VO2peak in a thermoneutral environment. IOP was measured before and after exercise and during recovery (15, 30 and 45 min) using the applanation tonometry method. Skin and rectal temperatures, heart rate and oxygen uptake were measured continuously. IOP was similar for the right eye and the left eye and increased post-water ingestion under both exercising and resting conditions (P<0.05) but did not differ between resting and exercising situations, or between the three water temperatures. Time to exhaustion was not affected by the different water temperatures. Rectal temperature, hydration status, heart rate, oxygen uptake, carbon dioxide extraction and lactate concentration were increased by exercise but were not affected by water temperature. We conclude that IOP was not affected by exercise and that water ingestion increased IOP as expected, regardless of water temperature.
Resumo:
Several methods have been described to measure intraocular pressure (IOP) in clinical and research situations. However, the measurement of time varying IOP with high accuracy, mainly in situations that alter corneal properties, has not been reported until now. The present report describes a computerized system capable of recording the transitory variability of IOP, which is sufficiently sensitive to reliably measure ocular pulse peak-to-peak values. We also describe its characteristics and discuss its applicability to research and clinical studies. The device consists of a pressure transducer, a signal conditioning unit and an analog-to-digital converter coupled to a video acquisition board. A modified Cairns trabeculectomy was performed in 9 Oryctolagus cuniculus rabbits to obtain changes in IOP decay parameters and to evaluate the utility and sensitivity of the recording system. The device was effective for the study of kinetic parameters of IOP, such as decay pattern and ocular pulse waves due to cardiac and respiratory cycle rhythm. In addition, there was a significant increase of IOP versus time curve derivative when pre- and post-trabeculectomy recordings were compared. The present procedure excludes corneal thickness and error related to individual operator ability. Clinical complications due to saline infusion and pressure overload were not observed during biomicroscopic evaluation. Among the disadvantages of the procedure are the requirement of anesthesia and the use in acute recordings rather than chronic protocols. Finally, the method described may provide a reliable alternative for the study of ocular pressure dynamic alterations in man and may facilitate the investigation of the pathogenesis of glaucoma.
Resumo:
The present study aimed to study the effects of exercise training (ET) performed by rats on a 10-week high-fructose diet on metabolic, hemodynamic, and autonomic changes, as well as intraocular pressure (IOP). Male Wistar rats receiving fructose overload in drinking water (100 g/L) were concomitantly trained on a treadmill for 10 weeks (FT group) or kept sedentary (F group), and a control group (C) was kept in normal laboratory conditions. The metabolic evaluation comprised the Lee index, glycemia, and insulin tolerance test (KITT). Arterial pressure (AP) was measured directly, and systolic AP variability was performed to determine peripheral autonomic modulation. ET attenuated impaired metabolic parameters, AP, IOP, and ocular perfusion pressure (OPP) induced by fructose overload (FT vs F). The increase in peripheral sympathetic modulation in F rats, demonstrated by systolic AP variance and low frequency (LF) band (F: 37±2, 6.6±0.3 vs C: 26±3, 3.6±0.5 mmHg2), was prevented by ET (FT: 29±3, 3.4±0.7 mmHg2). Positive correlations were found between the LF band and right IOP (r=0.57, P=0.01) and left IOP (r=0.64, P=0.003). Negative correlations were noted between KITT values and right IOP (r=-0.55, P=0.01) and left IOP (r=-0.62, P=0.005). ET in rats effectively prevented metabolic abnormalities and AP and IOP increases promoted by a high-fructose diet. In addition, ocular benefits triggered by exercise training were associated with peripheral autonomic improvement.
Resumo:
Thèse numérisée par la Division de la gestion de documents et des archives de l'Université de Montréal.
Resumo:
O objetivo deste estudo foi o de avaliar uma associação anestésica com e sem a utilização de relaxante muscular não-despolarizante e seu efeito sobre a pressão intra-ocular de eqüinos. Também objetivou-se uma técnica anestésica sem efeitos adversos que possa ser utilizada em procedimentos e cirurgias oftálmicas nesta espécie animal. Para tanto, dezesseis eqüinos foram divididos aleatoriamente em dois grupos de oito animais cada. Os animais do grupo I foram pré-medicados com romifidina, induzidos com tiletamina/zolazepam e a anestesia foi mantida com halotano e vecurônio. Os animais do grupo II receberam a mesma associação anestésica, com exceção do vecurônio. No decorrer do experimento, a pressão intra-ocular, a pressão arterial e a freqüência cardíaca foram avaliadas em diferentes momentos. A associação anestésica composta pela romifidina, tiletamina/ zolazepam e halotano com e sem vecurônio não promoveu alterações estatisticamente significativas na pressão intra-ocular de eqüinos e o seu uso é exeqüível em procedimentos oftálmicos nesta espécie animal.
Resumo:
Objetivou-se comparar os valores normais de pressão intraocular (PIO) e de produção lacrimal, através de tonometria de aplanação e do teste da lágrima de Schirmer-1 (TLS-1) em cabras da raça Saanen, com diferentes idades e momentos. Trinta e seis cabras da raça Saanen, livres de afecções oculares, foram agrupadas em três categorias etárias (n=12), compreendendo animais com 45, 180 e 549 dias de idade. O TLS-1 e a PIO foram aferidos sempre às 9:00 e às 19:00, durante três dias consecutivos. Os resultados foram avaliados estatisticamente (p<0,05). Relativamente ao horário do dia, a PIO foi significativamente menor às 19:00 (p<0,001) nos animais com 45 dias de idade; os valores do TLS-1 foram significativamente maiores às 19:00 (p=0,004) nas cabras com 549 dias de idade. Considerando-se a somatória dos três dias, ambos os parâmetros foram significativamente menores nos indivíduos com 45 dias de idade (p<0,001). A pressão intraocular e a produção lacrimal em cabras da raça Saanen se elevam de forma significativa até os 180 dias de idade.
Resumo:
Avaliou-se a pressão intra-ocular (PIO) e estimaram-se as correlações entre PIO e pressão de dióxido de carbono (PaCO2) e pH arterial de cinco caracarás (Caracara plancus), anestesiados com isofluorano (ISO) ou sevofluorano (SEV). Valores basais da PIO foram aferidos em ambos os olhos (M0). Cateterizou-se previamente a artéria braquial para obtenção de parâmetros hemogasométricos e cardiorrespiratórios. Anestesia foi induzida com ISO a 5V% e mantida por 40 minutos com 2,5V%. PIO e amostras de sangue foram avaliadas em diferentes momentos até o final do procedimento. Após recuperação, uma segunda anestesia foi realizada com SEV a 6% e mantida com 3,5%. Os parâmetros foram aferidos nos mesmos momentos estabelecidos previamente. A PIO decresceu significativamente (P=0,012) de M0 em todos os momentos e não houve diferença estatística entre ISO e SEV. Correlações significativas entre PIO e PaCO2 e entre PIO e pH sangüíneo foram observadas apenas para a anestesia com SEV. O pH sangüíneo decresceu paralelamente a PIO, enquanto a PaCO2 aumentou, em carcarás anestesiados com isofluorano e sevofluorano.
Resumo:
Estudaram-se e compararam-se os efeitos do levobunolol, da combinação fixa de dorzolamida 2%-timolol 0,5% e da associação de dorzolamida 2% com levobunolol 0,5% sobre a pressão intra-ocular (PIO), o diâmetro pupilar (DP), a freqüência cardíaca (FC) e a hiperemia conjuntival em 18 gatos saudáveis. PIO, DP, FC e hiperemia conjuntival foram aferidos diariamente, em três horários distintos (9h, 14h e 18h). Três grupos foram formados (n=6) e um olho de cada animal recebeu, aleatoriamente, uma gota de levobunolol (L), ou a combinação comercial à base de dorzolamida-timolol (DT), ou a associação de dorzolamida com levobunolol (DL). Parâmetros basais foram aferidos no primeiro dia (dia 0). Nos quatro dias consecutivos, os fármacos foram instilados às 8h e 20h e os parâmetros aferidos nos mesmos horários. Todos os parâmetros decresceram significativamente em relação aos valores basais (P<0,001) e não se observou hiperemia conjuntival. O levobunolol reduziu significativamente a PIO, o DP e a FC e o foi o fármaco que mais reduziu a FC. Não se observou efeito sinérgico na redução da PIO quando a dorzolamida foi adicionada ao levobulol.
Resumo:
Purpose To compare the effects of travoprost 0.004% and latanoprost 0.005% on the intraocular pressure (IOP) of normal dogs.Methods Twenty mixed breed dogs were randomized to two groups: latanoprost was used in group A and travoprost in group B. The drugs were instilled in the right eye of the dogs, whereas the left eye received placebo. Both drugs were instilled once a day at 8 AM during 5 days. IOP measurements were made at 8 AM, 10 AM, 2 PM and 8 PM during the 5 days of treatment, the 3 days that preceded treatment, and 3 days following treatment. Presence of blepharospasm, miosis, anterior chamber flare, and conjunctival hyperemia were evaluated during the study.Results Mean IOP was significantly reduced in the eyes treated with both latanoprost and travoprost, when compared with the eyes treated with placebo (P < 0.05). There was no statistically significant difference between the mean IOPs of eyes treated with latanoprost and travoprost at all time intervals during baseline, treatment, and recovery (P > 0.05). on the fifth day of treatment and on the first day of the recovery period, a severe ocular hypotension was noted with both drugs, resulting in imprecise readings with the tonometer. Miosis and conjunctival hyperemia were observed in the treated eyes of both groups, whereas flare was noticed in one latanoprost-treated eye.Conclusion Travoprost 0.004% significantly reduces the IOP in normal dogs. The hypotensive effect obtained with travoprost 0.004% is comparable to that obtained with latanoprost 0.005%.
Resumo:
The objective of this study was to determine intraocular pressure (IOP) and cardiac changes in normocapnic dogs maintained under controlled ventilation and anesthetized using sevoflurane or desflurane. Sixteen healthy adult mixed-breed dogs, seven males and nine females, weighing 10-15 kg were used. The dogs were randomly assigned to one of two groups composed of eight animals anesthetized with sevoflurane (SEVO) or desflurane (DESF). In both groups, anesthesia was induced with propofol (10 mg/kg), and neuromuscular blockade was achieved with rocuronium (0.6 mg/kg/h IV). No premedication was given. Ventilation was adjusted to maintain end-tidal carbon dioxide partial pressure at 35 mmHg. Anesthesia was maintained with 1.5 minimum alveolar concentration (MAC) of sevoflurane or desflurane. In both groups IOP was measured by applanation tonometry (Tono-Pen) before induction of anesthesia. IOP, mean arterial pressure (MAP), heart rate (HR), cardiac index (CI) and central venous pressure (CVP) were also measured 45 min after the beginning of inhalant anesthesia and then every 20 min for 60 min. A one-way repeated measures ANOVA was used to compare data within the same group and Student's t-test was used to assess differences between groups. P < 0.05 was considered statistically significant. Measurements showed normal IOP values in both groups, even though IOP increased significantly from baseline during the use of desflurane. IOP did not differ between groups. CI in the desflurane group was significantly greater than in the sevoflurane group. Sevoflurane and desflurane have no clinically significant effects on IOP, MAP, HR, CI or VCP in the dog.
Resumo:
The effects of metaraminol bitartrate on intraocular pressure (IOP) were studied in dogs anesthetized with halothane. Forty-five healthy, adult, mixed-breed dogs, of both sexes, were divided into three groups of 15 dogs each (GI, GII and GIII) and maintained under general anesthesia with halothane after tranquilization with levomepromazine and induction with thiopental. Saline (0.9%) was administered intravenously (IV) to GI through continuous infusion, at a velocity of 0.125 mL kg -1 min -1. GII and GIII received metaraminol 0.004% IV, at a dose of 5 μg kg -1 min -1, at 0.125 mL kg -1 min -1 and at a dose of 2 μg kg -1 min -1, at 0.06 mL kg -1 min -1, respectively. IOP was measured by applanation tonometry (Tono-Pen) before and during anesthesia. Results showed that IOP decreased in GI, increased in GII, and remained at basal levels in GIII. Continuous infusion of metaraminol at 2 μg kg min -1 maintained IOP at pretest levels, while infusion at 5 μg kg -1 min -1 produced an elevation of IOP.